Abstract 9778: Harmonizing Cutoff Values for Severe Aortic Valve Stenosis
Jump to

Abstract
Background: Decision making in patients with aortic valve stenosis (AS) and normal left ventricular function may be complicated by inconsistencies in cutoff values for severe AS. Particularly, the constellation of severe stenosis according to aortic valve area (AVA) <1cm2 and non-severe stenosis according to mean pressure gradient (MPG) ≤40mmHg is a frequent finding which may, at least in part, be due to systematic discrepancies between cutoff values.
Methods: We evaluated the effect of adjusting the cutoff value for severe AS from AVA 1.0cm2 to 0.8cm2 on discrepancies in classification of severity and event rates in 1525 asymptomatic patients with normal ejection fraction prospectively followed for a mean of 46 months from the SEAS (Simvastatin and Ezetimibe in Aortic Stenosis) study.
Results: The diagnosis of a severe AS was made in 56 (4%) patients according to the MPG >40mmHg criterion, in 470 (31%) based on an AVA of <1.0cm2 and in 185 (12%) with an AVA of <0.8cm2. After dividing the population into quintiles according to AVA and MPG an aortic valve related event rate of 0.40 was observed in patients with a mean AVA of 1.0±0.1cm2 which was similar to patients with a MPG of 27±2mmHg (0.40, p=ns). In turn, patients with a MPG of 37±5mm had an event rate of 0.65 and patients with an AVA of 0.74±0.1cm2 had an event rate of 0.53 (figure). Cardiovascular death rates followed a similar pattern.
Conclusion: Adjusting the cutoff value for severe stenosis in patients with normal left ventricular function from AVA 1.0cm2 to 0.8cm2 may harmonize parameters for the assessment of aortic stenosis both with respect to stenosis severity as well as clinical outcome.
- © 2012 by American Heart Association, Inc.
This Issue
Jump to
Article Tools
- Abstract 9778: Harmonizing Cutoff Values for Severe Aortic Valve StenosisJan Minners, Christa Gohlke-Baerwolf, Edda Bahlmann, Simon Ray, John B Chambers, Eva Gerdts, Kristian Wachtell, Anne Rossebo, Ronnie Willenheimer, Kurt Boman, Kenneth Egstrup, Terje Skjaerpe, Antero Kesaniemi, Terje R Pedersen, Philippe Brudi, Christoph A Nienaber, Franz-Josef Neumann and Nikolaus JanderCirculation. 2012;126:A9778, originally published January 6, 2016
Citation Manager Formats
Share this Article
- Abstract 9778: Harmonizing Cutoff Values for Severe Aortic Valve StenosisJan Minners, Christa Gohlke-Baerwolf, Edda Bahlmann, Simon Ray, John B Chambers, Eva Gerdts, Kristian Wachtell, Anne Rossebo, Ronnie Willenheimer, Kurt Boman, Kenneth Egstrup, Terje Skjaerpe, Antero Kesaniemi, Terje R Pedersen, Philippe Brudi, Christoph A Nienaber, Franz-Josef Neumann and Nikolaus JanderCirculation. 2012;126:A9778, originally published January 6, 2016Permalink:







