Submitted on December 17, 2005
From the Department of Cardiology, Thoraxcenter (C.A.G.V.M., F.C., N.R.M., M.V., W.B.M., E.P.M., J.L., N.B., E.R., W.J.v.d.G., G.S., R.v.D., P.d.J., P.W.S., P.J.d.F.) and Department of Radiology (C.A.G.V.M., F.C., N.R.M., P.M., W.B.M., F.P., G.R., G.P.K., P.J.d.F.), Erasmus MC, Rotterdam, the Netherlands; and Medical Center Rijnmond Zuid (P.C.S.), Rotterdam, the Netherlands. * To whom correspondence should be addressed. E-mail: p.j.defeyter{at}erasmusmc.nl.
Background--Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA. Methods and Results--Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n=27), but we switched to the 64-slice scanner after that period (n=43). Patients with initial heart rates >65 bpm received Conclusions--Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first-line alternative to CCA.
Revised on June 7, 2006
Accepted on June 8, 2006
Multislice Spiral Computed Tomography for the Evaluation of Stent Patency After Left Main Coronary Artery Stenting. A Comparison With Conventional Coronary Angiography and Intravascular Ultrasound
Carlos A.G. Van Mieghem MD,
-blockers, which resulted in a mean periscan heart rate of 57±7 bpm. Among patients with technically adequate scans (n=70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r=0.78 and 0.73, respectively). An intravascular ultrasound threshold value
1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT.
This article has been cited by other articles:
![]() |
F Pugliese, A C Weustink, C Van Mieghem, F Alberghina, M Otsuka, W B Meijboom, N van Pelt, N R Mollet, F Cademartiri, G P Krestin, et al. Dual source coronary computed tomography angiography for detecting in-stent restenosis Heart, July 1, 2008; 94(7): 848 - 854. [Abstract] [Full Text] [PDF] |
||||
![]() |
W T Roberts, J J Bax, and L C Davies Cardiac CT and CT coronary angiography: technology and application Heart, June 1, 2008; 94(6): 781 - 792. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Schroeder, S. Achenbach, F. Bengel, C. Burgstahler, F. Cademartiri, P. de Feyter, R. George, P. Kaufmann, A. F. Kopp, J. Knuuti, et al. Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology Eur. Heart J., February 2, 2008; 29(4): 531 - 556. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Bateman Business Aspects of Cardiovascular Computed Tomography: Tackling the Challenges J. Am. Coll. Cardiol. Img., January 1, 2008; 1(1): 111 - 118. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Abdulla, S. Z. Abildstrom, O. Gotzsche, E. Christensen, L. Kober, and C. Torp-Pedersen 64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis Eur. Heart J., December 2, 2007; 28(24): 3042 - 3050. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. L. Weisfeldt and S. J. Zieman Advances In The Prevention And Treatment Of Cardiovascular Disease Health Aff., January 1, 2007; 26(1): 25 - 37. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Kimmelstiel Multislice Computed Tomography After Left Main Drug-Eluting Stenting: Are We Putting the CarT Before the Horse? Circulation, August 15, 2006; 114(7): 616 - 619. [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2006 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |