Background--Pulmonary veins (PVs) can be completely isolated with continuous circular lesions (CCLs) around the ipsilateral PVs. However, electrophysiological findings have not been described in detail during ablation of persistent atrial fibrillation (AF). Methods and Results--Forty patients with symptomatic persistent AF underwent complete isolation of the right-sided and left-sided ipsilateral PVs guided by 3D mapping and double Lasso technique during AF. Irrigated ablation was initially performed in the right-sided CCLs and subsequently in the left-sided CCLs. After complete isolation of both lateral PVs, stable sinus rhythm was achieved after AF termination in 12 patients; AF persisted and required cardioversion in 18 patients. In the remaining 10 patients, AF changed to left macroreentrant atrial tachycardia in 6 and common-type atrial flutter in 4 patients. All atrial tachycardias were successfully terminated during the procedure. Atrial tachyarrhythmias recurred in 15 of 40 patients at a median of 4 days after the initial ablation. A repeat ablation was performed at a median of 35 days after the initial procedure in 14 patients. During the repeat study, recovered PV conduction was found in 13 patients and successfully abolished by focal ablation of the conduction gap of the previous CCLs. After a mean of 8±2 months of follow-up, 38 (95%) of the 40 patients were free of AF. Conclusions--In patients with persistent AF, CCLs can result in either AF termination or conversion to macroreentrant atrial tachycardia in 55% of the patients. In addition, recovered PV conduction after the initial procedure is a dominant finding in recurrent atrial tachyarrhythmias and can be successfully abolished.
Revised on July 4, 2005
Accepted on August 22, 2005
Electrophysiological Findings During Ablation of Persistent Atrial Fibrillation With Electroanatomic Mapping and Double Lasso Catheter Technique
Feifan Ouyang MD*,
This article has been cited by other articles:
![]() |
C. Schneider, R. Malisius, K. Krause, F. Lampe, E. Bahlmann, S. Boczor, M. Antz, S. Ernst, and K.-H. Kuck Strain rate imaging for functional quantification of the left atrium: atrial deformation predicts the maintenance of sinus rhythm after catheter ablation of atrial fibrillation Eur. Heart J., June 1, 2008; 29(11): 1397 - 1409. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Oral, A. Chugh, E. Good, T. Crawford, J. F. Sarrazin, M. Kuhne, N. Chalfoun, D. Wells, W. Boonyapisit, N. Gadeela, et al. Randomized Evaluation of Right Atrial Ablation After Left Atrial Ablation of Complex Fractionated Atrial Electrograms for Long-Lasting Persistent Atrial Fibrillation Circ Arrhythmia Electrophysiol, April 1, 2008; 1(1): 6 - 13. [Abstract] [Full Text] [PDF] |
||||
![]() |
X.-h. Wang, H.-f. Shi, Y.-m. Sun, J.-n. Gu, L. Zhou, and X. Liu Circumferential pulmonary vein isolation: the role of key target sites Europace, February 1, 2008; 10(2): 197 - 204. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.-C. Seow, T.-W. Lim, C.-H. Koay, D. L. Ross, and S. P. Thomas Efficacy and late recurrences with wide electrical pulmonary vein isolation for persistent and permanent atrial fibrillation Europace, December 1, 2007; 9(12): 1129 - 1133. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Arrantes, F. Gaita, K.-t. Lim, M. Scaglione, P. Jais, M. Hocini, S. Matsuo, S. Knecht, and M. Haissaguerre Atrial fibrillation ablation: evolution of the curative approach Eur. Heart J. Suppl., December 1, 2007; 9(suppl_I): I129 - I135. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. D. O'Neill, P. Jais, M. Hocini, F. Sacher, G. J. Klein, J. Clementy, and M. Haissaguerre Catheter Ablation for Atrial Fibrillation Circulation, September 25, 2007; 116(13): 1515 - 1523. [Full Text] [PDF] |
||||
![]() |
T. Arentz, R. Weber, G. Burkle, C. Herrera, T. Blum, J. Stockinger, J. Minners, F. J. Neumann, and D. Kalusche Small or Large Isolation Areas Around the Pulmonary Veins for the Treatment of Atrial Fibrillation?: Results From a Prospective Randomized Study Circulation, June 19, 2007; 115(24): 3057 - 3063. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Calkins, J. Brugada, D. L. Packer, R. Cappato, S.-A. Chen, H. J.G. Crijns, R. J. Damiano Jr, D. W. Davies, D. E. Haines, M. Haissaguerre, et al. HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Personnel, Policy, Procedures and Follow-Up: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation Developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Endorsed and Approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society. Europace, June 1, 2007; 9(6): 335 - 379. [Full Text] [PDF] |
||||
![]() |
H. Oral, A. Chugh, E. Good, A. Wimmer, S. Dey, N. Gadeela, S. Sankaran, T. Crawford, J. F. Sarrazin, M. Kuhne, et al. Radiofrequency Catheter Ablation of Chronic Atrial Fibrillation Guided by Complex Electrograms Circulation, May 22, 2007; 115(20): 2606 - 2612. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-Y. Kuo and S.-A. Chen Is Vagal Denervation a Good Alternative or Just Adjunctive to Pulmonary Vein Isolation in Catheter Ablation of Atrial Fibrillation? J. Am. Coll. Cardiol., March 27, 2007; 49(12): 1349 - 1351. [Full Text] [PDF] |
||||
|