Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1997;96:1217-1223

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strickberger, S. A.
Right arrow Articles by Morady, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strickberger, S. A.
Right arrow Articles by Morady, F.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Arrhythmia
*Pacemakers and Implantable Defibrillators

(Circulation. 1997;96:1217-1223.)
© 1997 American Heart Association, Inc.


Articles

Probability of Successful Defibrillation at Multiples of the Defibrillation Energy Requirement in Patients With an Implantable Defibrillator

S. Adam Strickberger, MD; Emile G. Daoud, MD; Theresa Davidson, RNr; Raul Weiss, MD; Frank Bogun, MD; Bradley P. Knight, MD; Marwan Bahu, MD; Rajiva Goyal, MD; K. Ching Man, DO; ; Fred Morady, MD

From the Department of Internal Medicine, University of Michigan Medical Ctr, Ann Arbor, Mich.

Correspondence to S. Adam Strickberger, MD, University of Michigan Medical Center, 1500 E Medical Center Dr, Ann Arbor, MI 48109-0022.

Background The probability of successful defibrillation has been determined in normal animals but not in patients undergoing defibrillator implantation. Therefore, the purpose of this prospective study was to determine the probability of successful defibrillation in humans on the basis of a step-down defibrillation energy requirement.

Methods and Results Fifty-three consecutive patients underwent five separate inductions of ventricular fibrillation after the defibrillation energy requirement was determined with the use of small decrements and a step-down protocol (20, 15, 12, 10, 8, 6, 5, 4, 3, 2, 1, and 0.8 J). The first shock energy for defibrillation was either 1.0, 1.3, 1.5, 1.7, or 2.0 times the defibrillation energy requirement, and the likelihoods of successful defibrillation were 70±27%, 84±12%, 86±25%, 80±29%, and 88±32%, respectively (P=.03). The frequencies of uniformly successful defibrillation (5 of 5 defibrillation attempts) were 30%, 27%, 60%, 64%, and 73%, respectively (P=.01). Seven patients in whom the defibrillation energy requirement was <4 J had an overall rate of successful defibrillation of 54±20% compared with 86±20% in the remaining 47 patients (P=.002). The likelihood of successful defibrillation at twice the defibrillation energy requirement was 98% in the 46 patients with a defibrillation energy requirement of >4 J and 67% in the 7 patients with a defibrillation energy requirement of <4 J (P=.17). An absolute safety margin of 7 J was associated with a 96% probability of successful defibrillation.

Conclusions The probability of successful defibrillation is 70% at the defibrillation energy requirement. The probability plateaus at 88%, at twice the defibrillation energy requirement. A 96% probability of successful defibrillation is achieved at an absolute safety margin of 7 J, and a 98% success rate is achieved at energies that are twice the defibrillation energy requirement if the defibrillation energy requirement is >4 J. If the defibrillation energy requirement is <4 J, larger multiples of the defibrillation energy requirement are needed to achieve a high probability of successful defibrillation.


Key Words: fibrillation • defibrillation • implantable defibrillator • arrhythmias




This article has been cited by other articles:


Home page
EuropaceHome page
B. Lemke, T. Lawo, M. Zarse, A. Lubinski, U. Kreutzer, J. Mueller, A. Schuchert, S. Mitzenheim, D. Danilovic, T. Deneke, et al.
Patient-tailored implantable cardioverter defibrillator testing using the upper limit of vulnerability: the TULIP protocol
Europace, May 30, 2008; (2008) eun136v1.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. D. Day, B. Olshansky, S. Moore, S. Brown, K. Q. Stolen, D. R. Lerew, and for the INTRINSIC RV Study Investigators
High defibrillation energy requirements are encountered rarely with modern dual-chamber implantable cardioverter-defibrillator systems
Europace, March 1, 2008; 10(3): 347 - 350.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. H. Hohnloser, P. Dorian, R. Roberts, M. Gent, C. W. Israel, E. Fain, J. Champagne, and S. J. Connolly
Effect of Amiodarone and Sotalol on Ventricular Defibrillation Threshold: The Optimal Pharmacological Therapy in Cardioverter Defibrillator Patients (OPTIC) Trial
Circulation, July 11, 2006; 114(2): 104 - 109.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
D. A.M.J. Theuns, T. Szili-Torok, and L. J. Jordaens
Defibrillation efficacy testing: Long-term follow-up and mortality
Europace, January 1, 2005; 7(6): 509 - 515.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. A. Strickberger and G. J. Klein
Is defibrillation testing required for defibrillator implantation?
J. Am. Coll. Cardiol., July 7, 2004; 44(1): 88 - 91.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
E. J. Rashba, M. R. Olsovsky, S. R. Shorofsky, M. M. Kirk, R. W. Peters, and M. R. Gold
Temporal decline in defibrillation thresholds with an active pectoral lead system
J. Am. Coll. Cardiol., October 1, 2001; 38(4): 1150 - 1155.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
B. Schulte, J. Sperzel, J. Carlsson, T. Schwarz, W. Ehrlich, H. F. Pitschner, and J. Neuzner
Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements
Europace, January 1, 2001; 3(3): 177 - 180.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
S. Windecker, R. E. Ideker, V. J. Plumb, G. N. Kay, G. P. Walcott, and A. E. Epstein
The influence of ventricular fibrillation duration on defibrillation efficacy using biphasic waveforms in humans
J. Am. Coll. Cardiol., January 1, 1999; 33(1): 33 - 38.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. R. Gold, S. Higgins, R. Klein, F. R. Gilliam, H. Kopelman, S. Hessen, J. Payne, S. A. Strickberger, D. Breiter, and S. Hahn
Efficacy and Temporal Stability of Reduced Safety Margins for Ventricular Defibrillation: Primary Results From the Low Energy Safety Study (LESS)
Circulation, April 30, 2002; 105(17): 2043 - 2048.
[Abstract] [Full Text] [PDF]