(Circulation. 1996;94:67-72.)
© 1996 American Heart Association, Inc.
Articles |
From the Department of Paediatrics, Division of Paediatric Cardiology, Sophia Children's Hospital (E.B., I.M.E.F.-M., J.H.); the Department of Epidemiology and Biostatistics, Erasmus University Medical School (E.B., D.E.G.); the Department of Obstetrics and Gynaecology, Division of Prenatal Diagnosis, University Hospital Rotterdam (E.B., P.A.S., J.W.W.); and Rotterdam "Thuiszorg" (Home Care) Foundation (R.E.J.), Rotterdam, Netherlands.
Correspondence to Dr E. Buskens, Division of Paediatric Cardiology, Sophia Children's Hospital, Dr Molewaterplein 60, 3015 GJ Rotterdam, Netherlands. Dr Buskens' current address is Department of Clinical Epidemiology, University Hospital Utrecht, PO Box 85500, 3508 GA Utrecht, Netherlands. E-mail ebuskens{at}rvb.azu.nl
Background Second trimester routine ultrasound evaluation of the fetal heart by means of the four-chamber view has been proposed for prenatal detection of cardiac anomalies. The aim of this study was to evaluate the efficacy of this procedure.
Methods and Results A prospective follow-up study on 6922 scanned fetuses was performed. Pregnant women without known risk factors who were scheduled for a routine fetal ultrasound examination between 16 and 24 weeks gestation were invited to participate. Follow-up until 6 months postpartum was available for 5660 subjects (81.8%), of whom 5319 fulfilled all eligibility criteria. By comparing the prenatal diagnosis to the postnatal diagnosis, we obtained sensitivity, specificity, and predictive value (positive and negative). A total of 80 cases of congenital malformations were diagnosed during the study: 44 cases of congenital heart disease, 40 cases of noncardiac malformations, and a combination of the two in 4 cases. The fetal four chamberview examination was considered abnormal in 7 women who were subsequently referred for extensive fetal ultrasound examination. Two proved to be carrying an affected fetus. Similarly, prenatal referral of 14 women because of suspected noncardiac malformations yielded 12 such cases. The fetal four chamberview examination had a sensitivity of 4.5% (95% CI, 0.6% to 15%). Sensitivity for noncardiac anomalies was 30% (95% CI, 16.6% to 46.5%). Overall sensitivity of ultrasound examination was 16.3% (95% CI, 2.09% to 48.8%). Specificity and negative predictive value were high (>98%). The positive predictive value was low with wide CIs.
Conclusions These results suggest that the current mode of routine prenatal ultrasound screening for congenital malformations is inefficient, particularly for cardiac anomalies.
Key Words: ultrasonics diagnosis heart defects, congenital echocardiography
This article has been cited by other articles:
![]() |
S Pathak and C Lees Ultrasound structural fetal anomaly screening: an update Arch. Dis. Child. Fetal Neonatal Ed., September 1, 2009; 94(5): F384 - F390. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Zimbelman and A. Sheikh Fetal Echocardiography and the Routine Obstetric Sonogram Journal of Diagnostic Medical Sonography, May 1, 2007; 23(3): 143 - 149. [PDF] |
||||
![]() |
J. Espinoza, J. P. Kusanovic, L. F. Goncalves, J. K. Nien, S. Hassan, W. Lee, and R. Romero A Novel Algorithm for Comprehensive Fetal Echocardiography Using 4-Dimensional Ultrasonography and Tomographic Imaging. J. Ultrasound Med., August 1, 2006; 25(8): 947 - 956. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Z. Abuhamad Standardization of 3-Dimensional Volumes in Obstetric Sonography: A Required Step for Training and Automation J. Ultrasound Med., April 1, 2005; 24(4): 397 - 401. [Full Text] [PDF] |
||||
![]() |
L. F. Goncalves, J. Espinoza, W. Lee, J. K. Nien, J.-S. Hong, J. Santolaya-Forgas, M. Mazor, and R. Romero A New Approach to Fetal Echocardiography: Digital Casts of the Fetal Cardiac Chambers and Great Vessels for Detection of Congenital Heart Disease J. Ultrasound Med., April 1, 2005; 24(4): 415 - 424. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Espinoza, L. F. Goncalves, W. Lee, T. Chaiworapongsa, M. C. Treadwell, S. Stites, M. L. Schoen, M. Mazor, and R. Romero The Use of the Minimum Projection Mode in 4-Dimensional Examination of the Fetal Heart With Spatiotemporal Image Correlation J. Ultrasound Med., October 1, 2004; 23(10): 1337 - 1348. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Abuhamad Automated Multiplanar Imaging: A Novel Approach to Ultrasonography J. Ultrasound Med., May 1, 2004; 23(5): 573 - 576. [Full Text] [PDF] |
||||
![]() |
Z. Weiner, A. Lorber, and E. Shalev Diagnosis of Congenital Cardiac Defects Between 11 and 14 Weeks' Gestation in High-Risk Patients J. Ultrasound Med., January 1, 2002; 21(1): 23 - 29. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Allan CONGENITAL HEART DISEASE: Antenatal diagnosis of heart disease Heart, March 1, 2000; 83(3): 367 - 367. [Full Text] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1996 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |