Background The use of stents improves the result after balloon coronary angioplasty. Thrombogenicity of stents is, however, a concern. In the present study, we compared stents with an antithrombotic coating with regular stents.
Methods and Results Regular stents were placed in coronary arteries of pigs receiving no aspirin (group 1; n=8) or aspirin over 4 weeks (group 2, n=10) or 12 weeks (group 3, n=9). Stents coated with heparin (antithrombin III uptake, 5 pmol/stent) were placed in 7 pigs that did not receive aspirin (group 4). The other animals received aspirin and coated stents with a heparin activity of 12 pmol antithrombin III/stent (group 5, n=10) or 20 pmol/stent (group 6, n=10; group 7, n=10). Quantitative arteriography was performed at implantation and after 4 (groups 1, 2, and 4 through 6) or 12 weeks (groups 3 and 7). In an additional 5 animals, five regular and five coated stents (20 pmol/stent) were placed and explanted after 5 days for examination of the early responses to the implants. Thrombotic occlusion of the regular stent occurred in 9 of 27 in groups 1 through 3. However, in 0 of 30 of the animals receiving high-activity heparin-coated stents (groups 5 through 7), thrombotic stent occlusion was observed (P<.001). Histological analysis at 4 weeks showed that the neointima in group 6 was thicker compared with its control group 2 (259±104 and 117±36 µm, P<.01), but at 12 weeks the thickness was similar (152±61 and 198±49 µm, respectively). Comparison at 5 days suggested delayed endothelialization of the coating.
Conclusions High-activity heparin coating of stents eliminates subacute thrombosis in porcine coronary arteries.
Key Words: stents thrombosis heparin
This article has been cited by other articles:
![]() |
A. Salahas, A. Vrahatis, I. Karabinos, I. Antonellis, G. Ifantis, I. Gavaliatsis, P. Anthopoulos, and A. Tavernarakis Success, Safety, and Efficacy of Implantation of Diamond-Like Carbon-Coated Stents Angiology, April 1, 2007; 58(2): 203 - 210. [Abstract] [PDF] |
||||
![]() |
R. Mehran, E. D. Aymong, D. T. Ashby, T. Fischell, H. Whitworth Jr, R. Siegel, W. Thomas, S. C. Wong, R. Narasimaiah, A. J. Lansky, et al. Safety of an Aspirin-Alone Regimen After Intracoronary Stenting With a Heparin-Coated Stent: Final Results of the HOPE (HEPACOAT and an Antithrombotic Regimen of Aspirin Alone) Study Circulation, September 2, 2003; 108(9): 1078 - 1083. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. N. Babapulle and M. J. Eisenberg Coated Stents for the Prevention of Restenosis: Part I Circulation, November 19, 2002; 106(21): 2734 - 2740. [Full Text] [PDF] |
||||
![]() |
T. A. Fischell and R. Virmani Intracoronary Brachytherapy in the Porcine Model: A Different Animal Circulation, November 13, 2001; 104(20): 2388 - 2390. [Full Text] [PDF] |
||||
![]() |
P.J. de Feyter The quest for the ideal stent Eur. Heart J., October 1, 2001; 22(19): 1766 - 1768. [PDF] |
||||
![]() |
J Wohrle, E Al-Khayer, U Grotzinger, C Schindler, M Kochs, V Hombach, and M Hoher Comparison of the heparin coated vs the uncoated Jostent(R)--no influence on restenosis or clinical outcome Eur. Heart J., October 1, 2001; 22(19): 1808 - 1816. [Abstract] [PDF] |
||||
![]() |
T. Suzuki, G. Kopia, S.-i. Hayashi, L. R. Bailey, G. Llanos, R. Wilensky, B. D. Klugherz, G. Papandreou, P. Narayan, M. B. Leon, et al. Stent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model Circulation, September 4, 2001; 104(10): 1188 - 1193. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Windecker, I. Mayer, G. De Pasquale, W. Maier, O. Dirsch, P. De Groot, Y.-P. Wu, G. Noll, B. Leskosek, B. Meier, et al. Stent Coating With Titanium-Nitride-Oxide for Reduction of Neointimal Hyperplasia Circulation, August 21, 2001; 104(8): 928 - 933. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. E. Drachman, E. R. Edelman, P. Seifert, A. R. Groothuis, D. A. Bornstein, K. R. Kamath, M. Palasis, D. Yang, S. H. Nott, and C. Rogers Neointimal thickening after stent delivery of paclitaxel: change in composition and arrest of growth over six months J. Am. Coll. Cardiol., December 1, 2000; 36(7): 2325 - 2332. [Abstract] [Full Text] [PDF] |
||||
![]() |
D M Whelan, W J van der Giessen, S C Krabbendam, E A van Vliet, P D Verdouw, P W Serruys, and H M M van Beusekom Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries Heart, March 1, 2000; 83(3): 338 - 345. [Abstract] [Full Text] |
||||
![]() |
C. L. Grines, D. A. Cox, G. W. Stone, E. Garcia, L. A. Mattos, A. Giambartolomei, B. R. Brodie, O. Madonna, M. Eijgelshoven, A. J. Lansky, et al. Coronary Angioplasty with or without Stent Implantation for Acute Myocardial Infarction N. Engl. J. Med., December 23, 1999; 341(26): 1949 - 1956. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. R. Edelman and C. Rogers Stent-Versus-Stent Equivalency Trials : Are Some Stents More Equal Than Others? Circulation, August 31, 1999; 100(9): 896 - 898. [Full Text] [PDF] |
||||
![]() |
C. Stefanadis, K. Toutouzas, E. Tsiamis, C. Vlachopoulos, S. Vaina, D. Tsekoura, L. Haldi, E. Stefanadi, M. Gravanis, and P. Toutouzas Stents covered by an autologous arterial graft in porcine coronary arteries: feasibility, vascular injury and effect on neointimal hyperplasia Cardiovasc Res, February 1, 1999; 41(2): 433 - 442. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. J. Topol and P. W. Serruys Frontiers in Interventional Cardiology Circulation, October 27, 1998; 98(17): 1802 - 1820. [Full Text] [PDF] |
||||
![]() |
H. M. M. van Beusekom, D. M. Whelan, S. H. Hofma, S. C. Krabbendam, V. W. M. van Hinsbergh, P. D. Verdouw, and W. J. van der Giessen Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries J. Am. Coll. Cardiol., October 1, 1998; 32(4): 1109 - 1117. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. F. Bertrand, R. Sipehia, R. Mongrain, J. Rodes, J.-C. Tardif, L. Bilodeau, G. Cote, and M. G. Bourassa Biocompatibility aspects of new stent technology J. Am. Coll. Cardiol., September 1, 1998; 32(3): 562 - 571. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Oberhoff, S. Novak, C. Herdeg, A. Baumbach, A. Kranzhofer, A. Bohnet, B. Horch, H. Hanke, K. K. Haase, and K. R. Karsch Local and systemic delivery of low molecular weight heparin stimulates the reendothelialization after balloon angioplasty Cardiovasc Res, June 1, 1998; 38(3): 751 - 762. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Van Belle, C. Bauters, T. Asahara, and J. M. Isner Endothelial regrowth after arterial injury: from vascular repair to therapeutics Cardiovasc Res, April 1, 1998; 38(1): 54 - 68. [Full Text] [PDF] |
||||
![]() |
H. J. Rupprecht, H. Darius, U. Borkowski, T. Voigtlander, B. Nowak, S. Genth, and J. Meyer Comparison of Antiplatelet Effects of Aspirin, Ticlopidine, or Their Combination After Stent Implantation Circulation, March 24, 1998; 97(11): 1046 - 1052. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. D. Phaneuf, W. C. Quist, F. W. Logerfo, M. Szycher, D. J. Dempsey, and M. J. Bide Chemical and Physical Characterization of a Novel Poly(Carbonate Urea) Urethane Surface with Protein Crosslinker Sites J Biomater Appl, October 1, 1997; 12(2): 100 - 120. [Abstract] |
||||
![]() |
D. Brieger and E. Topol Local drug delivery systems and prevention of restenosis Cardiovasc Res, September 1, 1997; 35(3): 405 - 413. [Full Text] [PDF] |
||||
![]() |
I. De Scheerder, K. Wang, K. Wilczek, D. Meuleman, R. Van Amsterdam, G. Vogel, J. Piessens, and F. Van de Werf Experimental Study of Thrombogenicity and Foreign Body Reaction Induced by Heparin-Coated Coronary Stents Circulation, March 18, 1997; 95(6): 1549 - 1553. [Abstract] [Full Text] |
||||
![]() |
R. R. Makkar, F. Litvack, N. L. Eigler, M. Nakamura, P. A. Ivey, J. S. Forrester, P. K. Shah, R. E. Jordan, and S. Kaul Effects of GP IIb/IIIa Receptor Monoclonal Antibody (7E3), Heparin, and Aspirin in an Ex Vivo Canine Arteriovenous Shunt Model of Stent Thrombosis Circulation, February 18, 1997; 95(4): 1015 - 1021. [Abstract] [Full Text] |
||||
![]() |
E. Van Belle, F. O. Tio, T. Couffinhal, L. Maillard, J. Passeri, and J. M. Isner Stent Endothelialization: Time Course, Impact of Local Catheter Delivery, Feasibility of Recombinant Protein Administration, and Response to Cytokine Expedition Circulation, January 21, 1997; 95(2): 438 - 448. [Abstract] [Full Text] |
||||
![]() |
T. A. Fischell Polymer Coatings for Stents: Can We Judge a Stent by Its Cover? Circulation, October 1, 1996; 94(7): 1494 - 1495. [Full Text] |
||||
![]() |
W. J. van der Giessen, A. M. Lincoff, R. S. Schwartz, H. M.M. van Beusekom, P. W. Serruys, D. R. Holmes, S. G. Ellis, and E. J. Topol Marked Inflammatory Sequelae to Implantation of Biodegradable and Nonbiodegradable Polymers in Porcine Coronary Arteries Circulation, October 1, 1996; 94(7): 1690 - 1697. [Abstract] [Full Text] |
||||
![]() |
P. N. Ruygrok and P. W. Serruys Intracoronary Stenting: From Concept to Custom Circulation, September 1, 1996; 94(5): 882 - 890. [Full Text] |
||||
![]() |
P. W. Serruys, H. Emanuelsson, W. van der Giessen, A. C. Lunn, F. Kiemeney, C. Macaya, W. Rutsch, G. Heyndrickx, H. Suryapranata, V. Legrand, et al. Heparin-Coated Palmaz-Schatz Stents in Human Coronary Arteries : Early Outcome of the Benestent-II Pilot Study Circulation, February 1, 1996; 93(3): 412 - 422. [Abstract] [Full Text] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1996 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |