Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1995;92:322-326

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Van Haesdonck, J.-M.
Right arrow Articles by Gewillig, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Van Haesdonck, J.-M.
Right arrow Articles by Gewillig, M.

(Circulation. 1995;92:322-326.)
© 1995 American Heart Association, Inc.


Articles

Comparison by Computerized Numeric Modeling of Energy Losses in Different Fontan Connections

Jean-Marie Van Haesdonck, MEng; Luc Mertens, MD; Renaud Sizaire, MEng; Gilberto Montas, MEng; Bruno Purnode, MEng; Wim Daenen, MD, PhD; Marcel Crochet, PhD; Marc Gewillig, MD, PhD

From the Departments of Pediatric Cardiology and Cardiac Surgery, KU Leuven, and the Department of Applied Mechanics, UCL Universities of Leuven and Louvain-la-Neuve, Belgium.

Correspondence to Marc Gewillig, MD, PhD, Professor of Pediatric Cardiology, Gasthuisberg University Hospital, B 3000 Leuven, Belgium.

Background Different surgical techniques for creating a Fontan circulation can be used. The option of including an atrium in the circuit, or the technique used for connecting the caval veins to the pulmonary artery in a total cavopulmonary connection, frequently is empirical and is based on personal experience and preference. The hemodynamic and energetic differences between the different circuits are small, and short-term results are comparable. However, small, energetic differences may have significant implications for the long-term follow-up. The finite element method allows a computer-based modeling of the flow dynamics and pressure losses. It permits comparison of different Fontan connections in a single patient with identical geometry and functional conditions.

Methods and Results We compared the atriopulmonary connection with different types of cavopulmonary connections, which differed in the degree of symmetry of implantation of both caval veins into the right pulmonary artery. Based on anatomic models and physiological flow dynamics, three-dimensional geometries and finite element meshes were created with PATRAN; flows were calculated with POLYFLOW (B), and results were visualized with DATA VISUALIZER.

Conclusions The atriopulmonary connection produces higher energy losses than the cavopulmonary connection (±1 mm Hg at rest). The cavopulmonary connection is more efficient when the connection of the caval veins to the pulmonary artery is asymmetrical.


Key Words: computers • models • Fontan procedure




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Gupta, C. Daggett, S. Behera, M. Ferraro, W. Wells, and V. Starnes
Risk factors for persistent pleural effusions after the extracardiac Fontan procedure
J. Thorac. Cardiovasc. Surg., June 1, 2004; 127(6): 1664 - 1669.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
E M Pedersen, E V Stenbog, T Frund, K Houlind, O Kromann, K E Sorensen, K Emmertsen, and V E Hjortdal
Flow during exercise in the total cavopulmonary connection measured by magnetic resonance velocity mapping
Heart, June 1, 2002; 87(6): 554 - 558.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
J. M. Chu, Q. Y. Wu, and W. M. Wang
Pulmonary Blood Distribution After Total Cavopulmonary Connection
Asian Cardiovasc Thorac Ann, December 1, 2001; 9(4): 282 - 285.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Sharma, A. E. Ensley, K. Hopkins, G. P. Chatzimavroudis, T. M. Healy, V. K.H. Tam, K. R. Kanter, and A. P. Yoganathan
In vivo flow dynamics of the total cavopulmonary connection from three-dimensional multislice magnetic resonance imaging
Ann. Thorac. Surg., March 1, 2001; 71(3): 889 - 898.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
G.S. Haas, H. Hess, M. Black, J. Onnasch, F.W. Mohr, and J.A.M. van Son
Extracardiac conduit Fontan procedure: early and intermediate results
Eur. J. Cardiothorac. Surg., June 1, 2000; 17(6): 648 - 654.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Gerdes, J. Kunze, G. Pfister, and H.-H. Sievers
Addition of a small curvature reduces power losses across total cavopulmonary connections
Ann. Thorac. Surg., June 1, 1999; 67(6): 1760 - 1764.
[Abstract] [Full Text] [PDF]