Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1995;92:2463-2472

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Camenzind, E.
Right arrow Articles by Serruys, P. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Camenzind, E.
Right arrow Articles by Serruys, P. W.

(Circulation. 1995;92:2463-2472.)
© 1995 American Heart Association, Inc.


Articles

Intracoronary Heparin Delivery in Humans

Acute Feasibility and Long-term Results

Edoardo Camenzind, MD; Peter-Paul Kint, RN; Carlo Di Mario, MD, PhD; Jürgen Ligthart, RN; Wim van der Giessen, MD, PhD; Eric Boersma, PhD; Patrick W. Serruys, MD, PhD

From the Cardiac Catheterization Laboratory and Intracoronary Imaging Laboratory, Thoraxcenter, University Hospital Dijkzigt, Rotterdam, Netherlands.

Correspondence to P.W. Serruys, MD, PhD, Catheterization Laboratory, Thoraxcenter Room Bd 416, University Hospital Dijkzigt, Erasmus University Rotterdam, Dr Molewaterplein 40, 3015 GD Rotterdam, Netherlands.

Background Inefficacy of systemic drug administration for restenosis prevention may partially relate to insufficient local drug concentration. This study aimed to evaluate the acute feasibility and long-term outcome of using an infusion-perfusion coil balloon, Dispatch.

Methods and Results In 22 patients after balloon angioplasty, the coil balloon was studied for (1) feasibility of local heparin delivery, (2) symptoms and signs of ischemia during prolonged deployment compared with angioplasty balloon occlusion, (3) coronary pressure and flow distal to the inflated device, and (4) long-term clinical and angiographic results. During prolonged intracoronary deployment of the coil balloon (29±8 minutes), 5 of 22 patients developed mild chest pain versus 20 of 22 during angioplasty (275±283 seconds). Neither hemodynamic nor vectorcardiographic signs of ischemia were detected, in contrast to angioplasty balloon occlusion. Baseline flow across the coil balloon was 44±31 mL/min, increasing by a factor of 1.8±0.7 during pharmacologically induced hyperemia. A mean volume of 14.2±6.1 mL containing 1416±608 IU of heparin was infused locally at a pressure of 122±54 mm Hg. At 7±1-month follow-up, 1 asymptomatic patient had died, and of the remaining 21, 17 (81%) were asymptomatic. Angiographic follow-up was obtained in 15 of 21 patients (71%), including all 4 symptomatic patients. Mean minimal luminal diameter after the procedure was 2.16±0.49 mm and at follow-up, 1.89±0.45 mm, which corresponds to a restenosis rate (diameter stenosis >=50%) of 7% (1/15).

Conclusions Intracoronary use of the coil balloon after balloon angioplasty proved to be feasible and subjectively as well as objectively well tolerated during prolonged deployment by virtue of its perfusion properties. High volumes of heparin solution can be infused locally at very low pressure. No unfavorable clinical or angiographic long-term effects were observed.


Key Words: angioplasty • heparin • restenosis • hemodynamics • perfusion




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
A. C. Ferreira, A. A. Peter, T. A. Salerno, H. Bolooki, and E. de Marchena
Clinical impact of drug-eluting stents in changing referral practices for coronary surgical revascularization in a tertiary care center
Ann. Thorac. Surg., February 1, 2003; 75(2): 485 - 489.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
C. Herdeg, M. Oberhoff, A. Baumbach, S. Schroeder, M. Leitritz, A. Blattner, D. I Siegel-Axel, C. Meisner, and K. R Karsch
Effects of local all-trans-retinoic acid delivery on experimental atherosclerosis in the rabbit carotid artery
Cardiovasc Res, February 1, 2003; 57(2): 544 - 553.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J Wohrle, E Al-Khayer, U Grotzinger, C Schindler, M Kochs, V Hombach, and M Hoher
Comparison of the heparin coated vs the uncoated Jostent(R)--no influence on restenosis or clinical outcome
Eur. Heart J., October 1, 2001; 22(19): 1808 - 1816.
[Abstract] [PDF]


Home page
Eur Heart JHome page
N Meneveau, F Schiele, G Grollier, B Farah, J.M Lablanche, K Khalife, J Machecourt, N Danchin, J.E Wolf, M Simpson, et al.
Local delivery of nadroparin for the prevention of neointimal hyperplasia following stent implantation: results of the IMPRESS Trial. A multicentre, randomized, clinical, angiographic and intravascular ultrasound study
Eur. Heart J., November 1, 2000; 21(21): 1767 - 1775.
[Abstract] [PDF]


Home page
Vasc MedHome page
D. S Ettenson and E. R Edelman
Local drug delivery: an emerging approach in the treatment of restenosis
Vascular Medicine, May 1, 2000; 5(2): 97 - 102.
[Abstract] [PDF]


Home page
Vasc MedHome page
M. O Hiltunen, M. P Turunen, M. Laitinen, and S. Yla-Herttuala
Insights into the molecular pathogenesis of atherosclerosis and therapeutic strategies using gene transfer
Vascular Medicine, February 1, 2000; 5(1): 41 - 48.
[Abstract] [PDF]


Home page
Vasc MedHome page
A. Gershlick
Endovascular manipulation to restrict restenosis
Vascular Medicine, August 1, 1998; 3(3): 177 - 188.
[Abstract] [PDF]


Home page
Cardiovasc ResHome page
M. Oberhoff, S. Novak, C. Herdeg, A. Baumbach, A. Kranzhofer, A. Bohnet, B. Horch, H. Hanke, K. K. Haase, and K. R. Karsch
Local and systemic delivery of low molecular weight heparin stimulates the reendothelialization after balloon angioplasty
Cardiovasc Res, June 1, 1998; 38(3): 751 - 762.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
L. J Feldman and G. Steg
Optimal techniques for arterial gene transfer
Cardiovasc Res, September 1, 1997; 35(3): 391 - 404.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Camenzind, W. H. Bakker, A. Reijs, I. M. van Geijlswijk, E. Boersma, M. J. B. Kutryk, E. P. Krenning, J. R. T. C. Roelandt, P. W. Serruys, and P. W. Serruys
Site-Specific Intracoronary Heparin Delivery in Humans After Balloon Angioplasty : A Radioisotopic Assessment of Regional Pharmacokinetics
Circulation, July 1, 1997; 96(1): 154 - 165.
[Abstract] [Full Text]


Home page
Circ. Res.Home page
J. Gunn, C. M. Holt, S. E. Francis, L. Shepherd, M. Grohmann, C. M. H. Newman, D. C. Crossman, and D. C. Cumberland
The Effect of Oligonucleotides to c-myb on Vascular Smooth Muscle Cell Proliferation and Neointima Formation After Porcine Coronary Angioplasty
Circ. Res., April 19, 1997; 80(4): 520 - 531.
[Abstract] [Full Text]


Home page
Cardiovasc ResHome page
O. Tahlil, M. Brami, L. J Feldman, D. Branellec, and Ph.G. Steg
The DispatchTM catheter as a delivery tool for arterial gene transfer
Cardiovasc Res, January 1, 1997; 33(1): 181 - 187.
[Abstract] [Full Text] [PDF]