(Circulation. 1995;92:1452-1457.)
© 1995 American Heart Association, Inc.
Articles |
From the University of Naples, Federico II Faculty of Medicine, Cattedra di Geriatria, Naples, Italy, and Northwestern University Medical School, Division of Cardiology, Chicago, Ill (R.O.B.).
Correspondence to Dino F. Vitale, MD, Cattedra di Geriatria, No 2 Faculty of Medicine, Via S Pansini 5, 80131 Napoli, Italia.
Background Experimentally induced myocardial ischemia in animals causes tissue modifications that alter characteristics of the ultrasonic beam backscattered from the myocardial muscle. Alterations of backscatter parameters have been evidenced in human subjects with acute or remote myocardial infarction and during ischemia induced by angioplasty balloon occlusion or pharmacological stimuli. The effects of transient effort ischemia in humans have not been reported. The purpose of this study is to assess ultrasonic backscatter parameter changes induced by transient effort myocardial ischemia in human subjects.
Methods and Results Nineteen patients with single left anterior descending coronary stenosis and 15 healthy subjects underwent ultrasonic backscatter analysis (parasternal long-axis view) at rest, immediately after a supine stress test, and 30 minutes later. Two windows were selected in each ultrasonic study: one encompassing the septum; the other, the posterior wall. Integrated backscatter was computed throughout the cardiac cycle, yielding a power curve relative to the midmyocardial region of the myocardial wall (excluding pericardial and endocardial borders). Five parameters were computed from the backscatter power curve: the maximum-minimum difference, amplitude and phase of the first harmonic Fourier fitting, phase-weighted amplitude, and time-averaged integrated backscatter difference from rest (an index of overall myocardial reflectivity). This protocol allowed comparison of the backscatter data from a region at risk of ischemia (the septum) with that from a region normally perfused (posterior wall) and a comparison with the same regions of the control group during the three ultrasonic studies. All backscatter indexes in the septum were altered significantly by exercise compared with rest values, whereas no changes were found in the normally perfused posterior wall or in the septum of the control group. All modified parameters returned to baseline values at the time of the recovery study.
Conclusions These data indicate that transient, exercise-induced ischemia is associated with reduction of the cardiac cycledependent variation of the integrated backscatter power curve, a temporal shift in the nadir of the power curve with respect to the R wave (phase increase), and a small but detectable increase of myocardial reflectivity. These changes may be detected noninvasively in humans with ultrasonic backscatter analysis.
Key Words: ischemia echocardiography
This article has been cited by other articles:
![]() |
K. Iwakura, H. Ito, S. Kawano, A. Okamura, K. Asano, T. Kuroda, K. Tanaka, T. Masuyama, M. Hori, and K. Fujii Detection of TIMI-3 Flow Before Mechanical Reperfusion With Ultrasonic Tissue Characterization in Patients With Anterior Wall Acute Myocardial Infarction Circulation, July 1, 2003; 107(25): 3159 - 3164. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Koyama, P. A. Ray-Sequin, and R. H. Falk Prognostic Significance of Ultrasound Myocardial Tissue Characterization in Patients With Cardiac Amyloidosis Circulation, July 30, 2002; 106(5): 556 - 561. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Hancock, J. C. Cooke, D. T. Chin, and M. J. Monaghan Determination of Successful Reperfusion After Thrombolysis for Acute Myocardial Infarction: A Noninvasive Method Using Ultrasonic Tissue Characterization That Can Be Applied Clinically Circulation, January 15, 2002; 105(2): 157 - 161. [Abstract] [Full Text] [PDF] |
||||
![]() |
T Muro, T Ota, H Watanabe, M Teragaki, K Takeuchi, and J Yoshikawa Prediction of contractile reserve by cyclic variation of integrated backscatter of the myocardium in patients with chronic left ventricular dysfunction Heart, February 1, 2001; 85(2): 165 - 170. [Abstract] [Full Text] |
||||
![]() |
K. Imasaka, S. Morita, I. Nagano, M. Masuda, R. Tominaga, and H. Yasui Coronary artery bypass grafting on the beating heart evaluated with integrated backscatter Ann. Thorac. Surg., September 1, 2000; 70(3): 1049 - 1053. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Colonna, R. Montisci, L. Galiuto, L. Meloni, and S. Iliceto Effects of Acute Myocardial Ischemia on Intramyocardial Contraction Heterogeneity : A Study Performed with Ultrasound Integrated Backscatter During Transesophageal Atrial Pacing Circulation, October 26, 1999; 100(17): 1770 - 1776. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Colonna, R. Montisci, L. Galiuto, L. Meloni, and S. Iliceto Effects of acute ischaemia on intramyocardial contraction heterogeneity; new ultrasound technologies to study an old phenomenon Eur. Heart J., March 1, 1999; 20(5): 327 - 337. [PDF] |
||||
![]() |
S. Takiuchi, H. Ito, K. Iwakura, Y. Taniyama, N. Nishikawa, T. Masuyama, M. Hori, Y. Higashino, K. Fujii, and T. Minamino Ultrasonic Tissue Characterization Predicts Myocardial Viability in Early Stage of Reperfused Acute Myocardial Infarction Circulation, February 3, 1998; 97(4): 356 - 362. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. F. Vitale, R. O. Bonow, R. Calabro, M. De Cristofaro, G. Pacileo, P. Caso, G. Gerundo, C. Bordini, M. A. Losi, C. Rengo, et al. Myocardial Ultrasonic Tissue Characterization in Pediatric and Adult Patients With Hypertrophic Cardiomyopathy Circulation, December 1, 1996; 94(11): 2826 - 2830. [Abstract] [Full Text] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1995 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |