Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1995;92:1452-1457

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vitale, D. F.
Right arrow Articles by Rengo, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vitale, D. F.
Right arrow Articles by Rengo, F.

(Circulation. 1995;92:1452-1457.)
© 1995 American Heart Association, Inc.


Articles

Alterations in Ultrasonic Backscatter During Exercise-Induced Myocardial Ischemia in Humans

Dino F. Vitale, MD; Robert O. Bonow, MD; Giusto Gerundo, MD; Nicola Pelaggi, MD; Gianfranco Lauria, PhD; Dario Leosco, MD; Fernando Coltorti, MD; Carlo Bordini, MD; Carlo Rengo, MD; Franco Rengo, MD

From the University of Naples, Federico II Faculty of Medicine, Cattedra di Geriatria, Naples, Italy, and Northwestern University Medical School, Division of Cardiology, Chicago, Ill (R.O.B.).

Correspondence to Dino F. Vitale, MD, Cattedra di Geriatria, No 2 Faculty of Medicine, Via S Pansini 5, 80131 Napoli, Italia.

Background Experimentally induced myocardial ischemia in animals causes tissue modifications that alter characteristics of the ultrasonic beam backscattered from the myocardial muscle. Alterations of backscatter parameters have been evidenced in human subjects with acute or remote myocardial infarction and during ischemia induced by angioplasty balloon occlusion or pharmacological stimuli. The effects of transient effort ischemia in humans have not been reported. The purpose of this study is to assess ultrasonic backscatter parameter changes induced by transient effort myocardial ischemia in human subjects.

Methods and Results Nineteen patients with single left anterior descending coronary stenosis and 15 healthy subjects underwent ultrasonic backscatter analysis (parasternal long-axis view) at rest, immediately after a supine stress test, and 30 minutes later. Two windows were selected in each ultrasonic study: one encompassing the septum; the other, the posterior wall. Integrated backscatter was computed throughout the cardiac cycle, yielding a power curve relative to the midmyocardial region of the myocardial wall (excluding pericardial and endocardial borders). Five parameters were computed from the backscatter power curve: the maximum-minimum difference, amplitude and phase of the first harmonic Fourier fitting, phase-weighted amplitude, and time-averaged integrated backscatter difference from rest (an index of overall myocardial reflectivity). This protocol allowed comparison of the backscatter data from a region at risk of ischemia (the septum) with that from a region normally perfused (posterior wall) and a comparison with the same regions of the control group during the three ultrasonic studies. All backscatter indexes in the septum were altered significantly by exercise compared with rest values, whereas no changes were found in the normally perfused posterior wall or in the septum of the control group. All modified parameters returned to baseline values at the time of the recovery study.

Conclusions These data indicate that transient, exercise-induced ischemia is associated with reduction of the cardiac cycle–dependent variation of the integrated backscatter power curve, a temporal shift in the nadir of the power curve with respect to the R wave (phase increase), and a small but detectable increase of myocardial reflectivity. These changes may be detected noninvasively in humans with ultrasonic backscatter analysis.


Key Words: ischemia • echocardiography




This article has been cited by other articles:


Home page
CirculationHome page
K. Iwakura, H. Ito, S. Kawano, A. Okamura, K. Asano, T. Kuroda, K. Tanaka, T. Masuyama, M. Hori, and K. Fujii
Detection of TIMI-3 Flow Before Mechanical Reperfusion With Ultrasonic Tissue Characterization in Patients With Anterior Wall Acute Myocardial Infarction
Circulation, July 1, 2003; 107(25): 3159 - 3164.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Koyama, P. A. Ray-Sequin, and R. H. Falk
Prognostic Significance of Ultrasound Myocardial Tissue Characterization in Patients With Cardiac Amyloidosis
Circulation, July 30, 2002; 106(5): 556 - 561.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. E. Hancock, J. C. Cooke, D. T. Chin, and M. J. Monaghan
Determination of Successful Reperfusion After Thrombolysis for Acute Myocardial Infarction: A Noninvasive Method Using Ultrasonic Tissue Characterization That Can Be Applied Clinically
Circulation, January 15, 2002; 105(2): 157 - 161.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
T Muro, T Ota, H Watanabe, M Teragaki, K Takeuchi, and J Yoshikawa
Prediction of contractile reserve by cyclic variation of integrated backscatter of the myocardium in patients with chronic left ventricular dysfunction
Heart, February 1, 2001; 85(2): 165 - 170.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
K. Imasaka, S. Morita, I. Nagano, M. Masuda, R. Tominaga, and H. Yasui
Coronary artery bypass grafting on the beating heart evaluated with integrated backscatter
Ann. Thorac. Surg., September 1, 2000; 70(3): 1049 - 1053.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. Colonna, R. Montisci, L. Galiuto, L. Meloni, and S. Iliceto
Effects of Acute Myocardial Ischemia on Intramyocardial Contraction Heterogeneity : A Study Performed with Ultrasound Integrated Backscatter During Transesophageal Atrial Pacing
Circulation, October 26, 1999; 100(17): 1770 - 1776.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. Colonna, R. Montisci, L. Galiuto, L. Meloni, and S. Iliceto
Effects of acute ischaemia on intramyocardial contraction heterogeneity; new ultrasound technologies to study an old phenomenon
Eur. Heart J., March 1, 1999; 20(5): 327 - 337.
[PDF]


Home page
CirculationHome page
S. Takiuchi, H. Ito, K. Iwakura, Y. Taniyama, N. Nishikawa, T. Masuyama, M. Hori, Y. Higashino, K. Fujii, and T. Minamino
Ultrasonic Tissue Characterization Predicts Myocardial Viability in Early Stage of Reperfused Acute Myocardial Infarction
Circulation, February 3, 1998; 97(4): 356 - 362.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. F. Vitale, R. O. Bonow, R. Calabro, M. De Cristofaro, G. Pacileo, P. Caso, G. Gerundo, C. Bordini, M. A. Losi, C. Rengo, et al.
Myocardial Ultrasonic Tissue Characterization in Pediatric and Adult Patients With Hypertrophic Cardiomyopathy
Circulation, December 1, 1996; 94(11): 2826 - 2830.
[Abstract] [Full Text]