Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1995;92:854-861

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ma, M. H.-M.
Right arrow Articles by Lien, W.-P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ma, M. H.-M.
Right arrow Articles by Lien, W.-P.

(Circulation. 1995;92:854-861.)
© 1995 American Heart Association, Inc.


Articles

Transesophageal Echocardiographic Assessment of Mitral Valve Position and Pulmonary Venous Flow During Cardiopulmonary Resuscitation in Humans

Matthew Huei-Ming Ma, MD; Juey-Jen Hwang, MD; Ling-Ping Lai, MD; Shih-Ming Wang, MD; Guan-Tarn Huang, MD; Kou-Gi Shyu, MD; Yu-Lin Ko, MD; Jiunn-Lee Lin, MD; Wen-Jone Chen, MD; Kwan-Lih Hsu, MD; Jin-Jer Chen, MD; Peiliang Kuan, MD; Yung-Zu Tseng, MD; Wen-Pin Lien, MD

From the Departments of Emergency Medicine (M.H.M., S.M.W., G.T.H.) and Internal Medicine (J.J.H., L.P.L., K.G.S., Y.L.K., J.L.L., W.J.C., K.L.H., J.J.C., P.K., Y.Z.T., W.P.L.), National Taiwan University Hospital, Taipei, Taiwan, ROC.

Background The mechanisms of blood flow during closed-chest cardiopulmonary resuscitation (CPR) in humans have been debated since the technique was first described in 1960. Two competing models, the cardiac pump theory and the thoracic pump theory, have been proposed, and some investigators have used mitral valve position during the downstroke of chest compression to distinguish between them. Previous studies using either transthoracic or transesophageal echocardiography have yielded conflicting results, and there have been few, if any, hemodynamic or echocardiographic studies on pulmonary venous flow (PVF) during CPR.

Methods and Results In this study, transesophageal two-dimensional and pulsed Doppler echocardiography were used to study mitral valve position and flow, together with PVF, in 20 adult patients undergoing manual CPR. In the 17 patients who could be analyzed, the mitral valve closed in 5 patients (group 1) during chest compression but stayed open or opened further in the remaining 12 patients (group 2). Peak forward mitral flow occurred during the release phase in group 1 but during the compression phase in group 2. During chest compression, PVF occurred in the forward direction (from the pulmonary vein to the left atrium) in 8 of the group 2 patients (group 2a) and in the backward direction (from the left atrium to the pulmonary vein) in all group 1 patients and the remaining 4 patients in group 2 (group 2b). The downtime (time from collapse to CPR) was significantly shorter (P<.05) for those in group 1 (7.0±4.4 minutes) than in groups 2a (19.8±7.7 minutes) and 2b (17.8±6.8 minutes).

Conclusions Transesophageal echocardiography performed during manual CPR in humans disclosed three different patterns of mitral valve position and PVF during chest compression. The presence of an opened mitral valve with forward mitral flow and backward pulmonary venous flow during chest compression in a small number of subjects underscores this heterogeneity in blood flow and suggests the possible existence of a "left atrium pump" in addition to the currently known "left ventricle pump" and "chest pump" mechanisms.


Key Words: cardiac arrest • cardiopulmonary resuscitation • echocardiography • blood flow




This article has been cited by other articles:


Home page
PediatricsHome page
P.-C. Kao, W.-C. Chiang, C.-W. Yang, S.-J. Chen, Y.-P. Liu, C.-C. Lee, M.-J. Hsidh, P. C.-I. Ko, S.-C. Chen, and M. H.-M. Ma
What Is the Correct Depth of Chest Compression for Infants and Children? A Radiological Study
Pediatrics, July 1, 2009; 124(1): 49 - 55.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. D. Kolarova, I. M. Ayoub, and R. J. Gazmuri
Cariporide enables hemodynamically more effective chest compression by leftward shift of its flow-depth relationship
Am J Physiol Heart Circ Physiol, June 1, 2005; 288(6): H2904 - H2911.
[Abstract] [Full Text] [PDF]