Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1993;88:2646-2654

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swartz, J. F.
Right arrow Articles by Karasik, P. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swartz, J. F.
Right arrow Articles by Karasik, P. E.

Circulation, Vol 88, 2646-2654, Copyright © 1993 by American Heart Association


ARTICLES

Optimization of biphasic waveforms for human nonthoracotomy defibrillation

JF Swartz, RD Fletcher and PE Karasik
Department of Medicine, Uniformed Services University, Bethesda, Md.

BACKGROUND. Biphasic waveforms reduce defibrillation threshold (DFT) in a wide variety of models. Although there are several human studies of long-duration, high-tilt biphasic waveform defibrillation, the specific biphasic waveform shape required to achieve optimal DFT reduction is unknown. METHODS AND RESULTS. This study tested the effect of single capacitor biphasic waveform tilt modification on DFT using a paired study design in 18 patients undergoing nonthoracotomy defibrillator implantation. Baseline DFT was obtained using a 65% tilt, simultaneous pulse, bidirectional monophasic shock from a right ventricular cathode to a coronary sinus or superior vena cava lead and a subscapular patch. The single-capacitor biphasic waveform shocks, delivered over the same pathways, consisted of either both phases at 65% tilt (65/65 biphasic waveform) to produce an overall tilt of 88% and a delivered energy 11% greater than monophasic shock or both phases at 42% tilt (42/42 biphasic waveform) to produce an overall tilt of 66% and delivered energy equal to monophasic shock. The 65/65 biphasic waveform reduced stored energy DFT 25%, from 16.2 +/- 4.4 J with monophasic shock to 12.1 +/- 5.3 J (P < .02); however, it did not significantly reduce the delivered energy DFT. In contrast, the 42/42 biphasic waveform required 49% less stored energy (16.2 +/- 4.4 J, monophasic shock, vs 8.3 +/- 3.3 J, biphasic waveform; P < .001) and 49% less delivered energy (14.2 +/- 3.8 J, monophasic shock, vs 7.3 +/- 2.9 J, biphasic waveform; P < .001) than monophasic shock for successful defibrillation. The 42/42 biphasic waveform delivered energy DFT was 4.6 +/- 5.2 J (39%) less than 65/65 biphasic waveform DFT (P < .002). CONCLUSIONS. DFT reduction is an inherent electrophysiological property of biphasic waveforms that is independent of delivered energy. Overall biphasic waveform tilt and the relative amplitudes of the waveform phases are important factors in defibrillation efficacy. Defibrillation with a 42/42 biphasic waveform is more efficacious than 65/65 biphasic waveform defibrillation; however, the optimal biphasic waveform remains unknown.


This article has been cited by other articles:


Home page
Emerg. Med. J.Home page
K Kajino, T Iwami, R A Berg, A Hiraide, Y Hayashi, H Yukioka, H Tanaka, T Shimazu, and H Sugimoto
Comparison of neurological outcomes following witnessed out-of-hospital ventricular fibrillation defibrillated with either biphasic or monophasic automated external defibrillators
Emerg. Med. J., July 1, 2009; 26(7): 492 - 496.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
J. P. Marenco, P. J. Wang, M. S. Link, M. K. Homoud, and N. A. M. Estes III
Improving Survival From Sudden Cardiac Arrest: The Role of the Automated External Defibrillator
JAMA, March 7, 2001; 285(9): 1193 - 1200.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. Brugada, B. Herse, B. Sandsted, U. Michel, B. D. Schubert, and S. J. Hahn
Clinical evaluation of defibrillation efficacy with a new single-capacitor biphasic waveform in patients undergoing implantation of an implantable cardioverter defibrillator
Europace, January 1, 2001; 3(4): 278 - 284.
[Abstract] [PDF]


Home page
CirculationHome page
S. R. Shorofsky and M. R. Gold
Effect of Second-Phase Duration on the Strength-Duration Relation for Human Transvenous Defibrillation
Circulation, October 31, 2000; 102(18): 2239 - 2242.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
X. Zhou, W. M. Smith, R. K. Justice, J. L. Wayland, and R. E. Ideker
Transmembrane potential changes caused by monophasic and biphasic shocks
Am J Physiol Heart Circ Physiol, November 1, 1998; 275(5): H1798 - H1807.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
G W N Dalzell
Determinants of successful defibrillation
Heart, October 1, 1998; 80(4): 405 - 407.
[Full Text]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. J. Sims, A. W. Miller, and M. R. Ujhelyi
Disparate effects of biphasic and monophasic shocks on postshock refractory period dispersion
Am J Physiol Heart Circ Physiol, June 1, 1998; 274(6): H1943 - H1949.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. Schauerte, F. A. Schondube, M. Grossmann, H. Dorge, F. Stein, B. Dohmen, A. Moumen, K. Erena, B. J. Messmer, P. Hanrath, et al.
Influence of Phase Duration of Biphasic Waveforms on Defibrillation Energy Requirements With a 70-µF Capacitance
Circulation, May 26, 1998; 97(20): 2073 - 2078.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. R. Gold and S. R. Shorofsky
Strength-Duration Relationship for Human Transvenous Defibrillation
Circulation, November 18, 1997; 96(10): 3517 - 3520.
[Abstract] [Full Text]


Home page
CirculationHome page
G. Tomassoni, K. Newby, S. Deshpande, K. Axtell, J. Sra, M. Akhtar, and A. Natale
Defibrillation Efficacy of Commercially Available Biphasic Impulses in Humans : Importance of Negative-Phase Peak Voltage
Circulation, April 1, 1997; 95(7): 1822 - 1826.
[Abstract] [Full Text]


Home page
CirculationHome page
A. Pacifico, K. R. Wheelan, N. Nasir, P. J. Wells, T. K. Doyle, S. A. Johnson, and P. D. Henry
Long-term Follow-up of Cardioverter-Defibrillator Implanted Under Conscious Sedation in Prepectoral Subfascial Position
Circulation, February 18, 1997; 95(4): 946 - 950.
[Abstract] [Full Text]


Home page
CirculationHome page
G. H. Bardy, F. E. Marchlinski, A. D. Sharma, S. J. Worley, R. M. Luceri, R. Yee, B. D. Halperin, C. L. Fellows, T. S. Ahern, D. A. Chilson, et al.
Multicenter Comparison of Truncated Biphasic Shocks and Standard Damped Sine Wave Monophasic Shocks for Transthoracic Ventricular Defibrillation
Circulation, November 15, 1996; 94(10): 2507 - 2514.
[Abstract] [Full Text]


Home page
CirculationHome page
S. Behrens, C. Li, P. Kirchhof, F. L. Fabritz, and M. R. Franz
Reduced Arrhythmogenicity of Biphasic Versus Monophasic T-Wave Shocks: Implications for Defibrillation Efficacy
Circulation, October 15, 1996; 94(8): 1974 - 1980.
[Abstract] [Full Text]


Home page
CirculationHome page
B. E. Gliner, T. E. Lyster, S. M. Dillion, and G. H. Bardy
Transthoracic Defibrillation of Swine With Monophasic and Biphasic Waveforms
Circulation, September 15, 1995; 92(6): 1634 - 1643.
[Abstract] [Full Text]


Home page
Circ. Res.Home page
O. H. Tovar and J. L. Jones
Biphasic Defibrillation Waveforms Reduce Shock-Induced Response Duration Dispersion Between Low and High Shock Intensities
Circ. Res., August 1, 1995; 77(2): 430 - 438.
[Abstract] [Full Text]


Home page
CirculationHome page
G. H. Bardy, B. E. Gliner, P. J. Kudenchuk, J. E. Poole, G. L. Dolack, G. K. Jones, J. Anderson, C. Troutman, and G. Johnson
Truncated Biphasic Pulses for Transthoracic Defibrillation
Circulation, March 15, 1995; 91(6): 1768 - 1774.
[Abstract] [Full Text]


Home page
CirculationHome page
G. H. Bardy, J. E. Poole, P. J. Kudenchuk, G. L. Dolack, R. Mehra, P. DeGroot, M. H. Raitt, G. K. Jones, and G. Johnson
A Prospective Randomized Comparison in Humans of Biphasic Waveform 60-µF and 120-µF Capacitance Pulses Using A Unipolar Defibrillation System
Circulation, January 1, 1995; 91(1): 91 - 95.
[Abstract] [Full Text]