Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1986;73:1321-1333

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Coltorti, F.
Right arrow Articles by Ivey, T. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Coltorti, F.
Right arrow Articles by Ivey, T. D.

Circulation, Vol 73, 1321-1333, Copyright © 1986 by American Heart Association


ARTICLES

Effects of varying electrode configuration with catheter-mediated defibrillator pulses at the coronary sinus orifice in dogs

F Coltorti, GH Bardy, D Reichenbach, HL Greene, R Thomas, DG Breazeale and TD Ivey

We compared two methods of delivering single damped sine-wave defibrillator pulses to the coronary sinus orifice in 20 dogs. Ten dogs had "unipolar" (coronary sinus to precordial disc) and 10 had "bipolar" (coronary sinus proximal to coronary sinus distal electrode) discharges. Delivered voltage, current, and energy were recorded during each pulse. Electrophysiologic testing was done before and 4 weeks after the procedure. Histologic examination of the atrioventricular groove was done at 1 mm serial sections. For the unipolar configuration a 200 J defibrillator pulse resulted in a peak voltage of 3370 +/- 125 V, a peak current of 21 +/- 4 A, and a delivered energy of 253 +/- 29 J as compared with 3010 +/- 99 V, 70 +/- 4 A, and 144 +/- 18 J, respectively, for the bipolar configuration (p less than .001). Three dogs (two with bipolar, one with unipolar pulses) had gross coronary sinus rupture and died from acute pericardial tamponade. In addition, irrespective of electrode configuration, all dogs showed microscopic rupture of the coronary sinus internal elastic membrane. Transmural atrial scarring occurred in all 10 dogs that received a unipolar pulse but in only two dogs that received a bipolar pulse (p = .0004). Unlike the atrium, injury to the left ventricle was limited in both groups. Similarly, injury to the periannular myocardium was inconsistent and not transmural in either group. No significant electrophysiologic changes were observed. With the present technique, unipolar rather than bipolar catheter-mediated defibrillator pulses result in transmural atrial injury that might prevent accessory pathway conduction. Regardless of electrode configuration, high-energy defibrillator pulses consistently cause some degree of coronary sinus rupture, most likely related to a barotraumatic mechanism.