Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1967;35:1092-1099

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by FEIGENBAUM, H.
Right arrow Articles by Haine, C. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by FEIGENBAUM, H.
Right arrow Articles by Haine, C. L.

(Circulation. 1967;35:1092.)
© 1967 American Heart Association, Inc.


Use of Ultrasound to Measure Left Ventricular Stroke Volume

HARVEY FEIGENBAUM M.D.1; ADIB ZAKY M.B.1; WILLIAM K. NASSER M.D.1; Charles L. Haine 1

1 From the Department of Medicine, Indiana University School of Medicine, and the Krannert Heart Research Institute, Marion County General Hospital, Indianapolis, Indiana.

Several empirical observations made during ultrasound examinations for pericardial effusion have led to the possibility that this diagnostic technique might be used to measure left ventricular stroke volume in man. The hypothesis that left ventricular stroke volume was proportional to the amplitude of an echo originating from a portion of the left ventricle near the mitral ring (MREa) times the distance between the echoes from the anterior and posterior ventricular walls (LVD) has been validated.

Ultrasound examinations were performed simultaneously with cardiac output determinations using the direct Fick method on 16 patients proven to have competent mitral and aortic valves. Correlation between the two methods of measuring left ventricular stroke volume was excellent (r = 0.973; P < 0.001). When ultrasound measurements were used in the regression equation to predict stroke volume, the calculated values were within 11 ml or 15% of those determined by the Fick method.

The fact that an ultrasound examination is simple, can be done as a bedside determination in a matter of minutes, and is totally harmless to the patient make it a promising diagnostic procedure. The measurement of left ventricular stroke volume represents another addition to the growing list of medical uses for this intriguing technique.


Key Words: Cardiac outptut • Ultrasound myocardial function • Echography




This article has been cited by other articles:


Home page
HeartHome page
J. E Sanderson
Left and right ventricular long-axis function and prognosis
Heart, March 1, 2008; 94(3): 262 - 263.
[Full Text] [PDF]


Home page
ANGIOLOGYHome page
N. G. Kounis, G. M. Zavras, G. D. Soufras, and M. Kitrou
Systolic and Diastolic Septal and Posterior Wall Echocardiographic Measurements in Normal Subjects
Angiology, June 1, 1989; 40(6): 521 - 526.
[Abstract] [PDF]


Home page
ANN INTERN MEDHome page
A. S. ABBASI
Heart in Rheumatoid Arthritis
Ann Intern Med, June 1, 1974; 80(6): 779 - 780.
[Abstract] [PDF]


Home page
Arch Intern MedHome page
H. Feigenbaum, R. L. Popp, S. B. Wolfe, B. L. Troy, J. F. Pombo, C. L. Haine, and H. T. Dodge
Ultrasound Measurements of the Left Ventricle: A Correlative Study With Angiocardiography
Arch Intern Med, March 1, 1972; 129(3): 461 - 467.
[Abstract] [PDF]