(Circulation. 2003;107:1250.)
© 2003 American Heart Association, Inc.
Brief Rapid Communications |
From the Department of Cardiology (C.T., H.J.G.M.C., L.-M.R.), Academic Hospital Maastricht, the Netherlands; and CryoCor, Inc, San Diego, Calif (G.M.A.).
Correspondence to Carl Timmermans, Department of Cardiology, Academic Hospital Maastricht, CARIM, P. Debyelaan 25, 6202 AZ Maastricht, The Netherlands. E-mail ccmm.timmermans{at}cardio.unimaas.nl
Background Radiofrequency ablation (RF) of atrial flutter (AFL) has a high procedural efficacy, a low recurrence rate, and reports of procedure-related pain. The aim of the present study was to compare RF with cryoablation (cryo) for the treatment of AFL, with emphasis on pain perception during application of energy.
Methods and Results Fourteen patients (55±11 years, 11 males) with AFL were randomized to receive ablation of the cavotricuspid isthmus (CTI) by either RF or cryo. Cryothermia was delivered with the CryoCor Cryoablation System (10F, 6-mm tip), and radiofrequency energy was delivered with the use of an 8-mmtip catheter. Pain was evaluated according to a visual analogue scale (VAS; 0 to 100). All patients in the cryo group were successfully ablated with a mean of 18 applications (9 sites), and RF was successful in 6 of 7 patients (not significant) with 13 applications (not significant). The mean temperature was -82°C and 55°C for cryo and RF, respectively. One patient in the cryo group perceived pain, versus all 7 patients in the RF group (P<0.05). The proportion of painful applications averaged 75.3% in the RF group and 2.0% in the cryo group (P<0.05), whereas the corresponding VAS for pain was 38.3±25.3 and 0.32±0.86, respectively (P<0.05). At 6-month follow-up, there were no recurrences of atrial flutter.
Conclusion Cryo, as compared with RF, produces significantly less pain during application. Although in the present study there was no significant difference in efficacy, larger studies will be needed to definitively compare efficacy.
Key Words: atrial flutter catheter ablation arrhythmia
This article has been cited by other articles:
![]() |
W. Moreira, R. Manusama, C. Timmermans, B. Ghaye, S. Philippens, H. J.J. Wellens, and L.-M. Rodriguez Long-Term Follow-Up After Cryothermic Ostial Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation J. Am. Coll. Cardiol., February 26, 2008; 51(8): 850 - 855. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. D. Beland, D. E. Dupuy, and W. W. Mayo-Smith Percutaneous Cryoablation of Symptomatic Extraabdominal Metastatic Disease: Preliminary Results Am. J. Roentgenol., March 1, 2005; 184(3): 926 - 930. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. S. Montenero, N. Bruno, A. Antonelli, D. Mangiameli, L. Barbieri, P. Andrew, O. Murphy, S. O'Connor, and F. Zumbo Long-term efficacy of cryo catheter ablation for the treatment of atrial flutter: Results from a repeat electrophysiologic study J. Am. Coll. Cardiol., February 15, 2005; 45(4): 573 - 580. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Hillock, I. C. Melton, and I. G. Crozier Radiofrequency ablation for common atrial flutter using an 8-mm tip catheter and up to 150 W Europace, January 1, 2005; 7(5): 409 - 412. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. S. Thornton and L. J. Jordaens Atrial flutter: Watch and control? Europace, January 1, 2005; 7(5): 413 - 414. [Full Text] [PDF] |
||||
![]() |
H. T Sie, W. P Beukema, A. Elvan, and A. R Ramdat Misier New strategies in the surgical treatment of atrial fibrillation Cardiovasc Res, June 1, 2003; 58(3): 501 - 509. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2003 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |