(Circulation. 2002;106:441.)
© 2002 American Heart Association, Inc.
Clinical Investigation and Reports |
From the Departments of Cardiology (M.M., M.S., S.A.J.C., K.T.K., R.J.d.W., J.G.P.T., J.J.P.), Nuclear Medicine (B.L.F.v.E.-S.), and Medical Physics (M.S., J.A.E.S.), Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands.
Correspondence to Jan J. Piek, MD, Department of Cardiology B2-108, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands. E-mail m.meuwissen{at}amc.uva.nl
Background Both coronary blood flow velocity reserve (CFVR) and myocardial fractional flow reserve (FFR) are used to evaluate the hemodynamic severity of coronary lesions. However, discordant results between CFVR and FFR have been observed in 25% to 30% of intermediate coronary lesions. An index of stenosis resistance based on a combination of intracoronary pressure and flow velocity may improve the assessment of functional coronary lesion severity.
Methods and Results Single photon emission computed tomography (SPECT) was performed in 151 patients with angina to determine reversible perfusion defects within one-week before cardiac catheterization. Coronary pressure and flow velocity was measured distal to 181 single coronary lesions with a mean diameter stenosis of 56% (range: 32% to 85%). Maximum hyperemia was induced by 15 to 20 µg IC adenosine to determine CFVR, FFR, and the hyperemic stenosis resistance index (h-SRv), defined as the ratio of hyperemic stenosis pressure gradient (mean aorta pressure-mean distal pressure) and hyperemic average peak-flow velocity. Receiver-operating-characteristic curves of CFVR, FFR, and h-SRv were calculated to evaluate the predictive value for presence of reversible perfusion defects on SPECT with the use of the area under curve (AUC). The AUC was significantly higher for h-SRv (0.90±0.03) compared with those for CFVR (0.80±0.04; P=0.024) and FFR (0.82±0.03; P=0.018), respectively. Agreement with SPECT was particularly higher (73%) than for CFVR (49%, P=0.022) or FFR (51%, P=0.037) in the group of lesions showing discordant results between CFVR and FFR
Conclusion These results indicate that hyperemic stenosis resistance index is a more powerful predictor of reversible perfusion defects than CFVR or FFR.
Key Words: coronary disease coronary blood flow myocardial perfusion scintigraphy stenosis ischemia
This article has been cited by other articles:
![]() |
N. Beohar, A. K. Erdogan, D. C. Lee, H. N. Sabbah, M. J. Kern, J. Teerlink, R. O. Bonow, and M. Gheorghiade Acute heart failure syndromes and coronary perfusion. J. Am. Coll. Cardiol., July 1, 2008; 52(1): 13 - 16. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Meimoun, T. Benali, F. Elmkies, S. Sayah, A. Luycx-Bore, L. Doutrelan, Z. Hamdane, J. Boulanger, and C. Tribouilloy Prognostic value of transthoracic coronary flow reserve in medically treated patients with proximal left anterior descending artery stenosis of intermediate severity Eur J Echocardiogr, June 25, 2008; (2008) jen190v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. J. Verberne, M. Meuwissen, S. A. J. Chamuleau, B.-J. Verhoeff, B. L. F. van Eck-Smit, J. A. E. Spaan, J. J. Piek, and M. Siebes Effect of simultaneous intracoronary guidewires on the predictive accuracy of functional parameters of coronary lesion severity Am J Physiol Heart Circ Physiol, May 1, 2007; 292(5): H2349 - H2355. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Kern, A. Lerman, J.-W. Bech, B. De Bruyne, E. Eeckhout, W. F. Fearon, S. T. Higano, M. J. Lim, M. Meuwissen, J. J. Piek, et al. Physiological Assessment of Coronary Artery Disease in the Cardiac Catheterization Laboratory: A Scientific Statement From the American Heart Association Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology Circulation, September 19, 2006; 114(12): 1321 - 1341. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A.E. Spaan, J. J. Piek, J. I.E. Hoffman, and M. Siebes Physiological Basis of Clinically Used Coronary Hemodynamic Indices Circulation, January 24, 2006; 113(3): 446 - 455. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Fokkema, J. W. G. E. VanTeeffelen, S. Dekker, I. Vergroesen, J. B. Reitsma, and J. A. E. Spaan Diastolic time fraction as a determinant of subendocardial perfusion Am J Physiol Heart Circ Physiol, May 1, 2005; 288(5): H2450 - H2456. [Abstract] [Full Text] [PDF] |
||||
![]() |
B.-J. Verhoeff, M. Siebes, M. Meuwissen, B. Atasever, M. Voskuil, R. J. de Winter, K. T. Koch, J. G.P. Tijssen, J. A.E. Spaan, and J. J. Piek Influence of Percutaneous Coronary Intervention on Coronary Microvascular Resistance Index Circulation, January 4, 2005; 111(1): 76 - 82. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Ogawa, T. Ohkubo, R. Fukazawa, M. Kamisago, Y. Kuramochi, Y. Uchikoba, E. Ikegami, M. Watanabe, and Y. Katsube Estimation of myocardial hemodynamics before and after intervention in children with kawasaki disease J. Am. Coll. Cardiol., February 18, 2004; 43(4): 653 - 661. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Krams, F. J. Ten Cate, S. G. Carlier, A. F. W. van der Steen, and P. W. Serruys Diastolic coronary vascular reserve: a new index to detect changes in the coronary microcirculation in hypertrophic cardiomyopathy J. Am. Coll. Cardiol., February 18, 2004; 43(4): 670 - 677. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Siebes, B.-J. Verhoeff, M. Meuwissen, R. J. de Winter, J. A.E. Spaan, and J. J. Piek Single-Wire Pressure and Flow Velocity Measurement to Quantify Coronary Stenosis Hemodynamics and Effects of Percutaneous Interventions Circulation, February 17, 2004; 109(6): 756 - 762. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Siebes, S. A. J. Chamuleau, M. Meuwissen, J. J. Piek, and J. A. E. Spaan Influence of hemodynamic conditions on fractional flow reserve: parametric analysis of underlying model Am J Physiol Heart Circ Physiol, October 1, 2002; 283(4): H1462 - H1470. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2002 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |