Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2002;105:2043-2048
Published online before print April 15, 2002, doi: 10.1161/01.CIR.0000015508.59749.F5
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
105/17/2043    most recent
01.CIR.0000015508.59749.F5v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gold, M. R.
Right arrow Articles by Hahn, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gold, M. R.
Right arrow Articles by Hahn, S.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Pacemakers and Implantable Defibrillators
Related Collections
Right arrow Ablation/ICD/surgery

(Circulation. 2002;105:2043.)
© 2002 American Heart Association, Inc.


Clinical Investigation and Reports

Efficacy and Temporal Stability of Reduced Safety Margins for Ventricular Defibrillation

Primary Results From the Low Energy Safety Study (LESS)

Michael R. Gold, MD, PhD; Steven Higgins, MD; Richard Klein, MD; F. Roosevelt Gilliam, MD; Harry Kopelman, MD; Scott Hessen, MD; John Payne, MD; S. Adam Strickberger, MD; David Breiter, MS; Stephen Hahn, PhD

From the Medical University of South Carolina, Charleston (M.R.G.); Scripps Memorial Hospital, La Jolla, Calif (S. Higgins); University of Utah, Salt Lake City (R.K.); Chippenham Medical Center, Richmond, Va (F.R.G.); Saint Joseph’s Hospital of Atlanta, Atlanta, Ga (H.K.); Hahnemann University, Philadelphia, Pa (S. Hennen); Baylor College of Medicine, Houston, Tex (J.P.); University of Michigan, Ann Arbor (S.A.S.); and Guidant Corporation, St Paul, Minn (D.B., S. Hahn).

Correspondence to Michael R. Gold, MD, PhD, Medical University of South Carolina, Division of Cardiology, 96 Jonathan Lucas Street, PO Box 250623, Charleston, SC 29425. E-mail Goldmr{at}musc.edu

Background Traditionally, a safety margin of at least 10 J between the maximum output of the pulse generator and the energy needed for ventricular defibrillation has been used because lower safety margins were associated with unacceptably high rates of failed defibrillation and sudden cardiac death. The Low Energy Safety Study (LESS) was a prospective, randomized assessment of the safety margin requirements for modern implantable cardioverter-defibrillator (ICD) systems.

Methods and Results A total of 636 patients undergoing initial ICD implantation with a dual-coil lead and active pulse generator were evaluated. The defibrillation threshold (DFT) and enhanced DFT (DFT+ and DFT++) were measured using a modified step-down protocol. Conversion testing of induced ventricular fibrillation before discharge, at 3 months, and at 12 months was performed, as was randomization to chronic programming at either 2 steps above DFT++ or maximal output. The induced ventricular fibrillation data had conversion success rates of 91.4%, 97.9%, 99.1%, 99.6%, and 99.8% for safety margins of 0, 1, 2, 3, and 4 steps above the DFT++, respectively. A margin of 4 to 6 J was adequate to maintain high conversion success over time (98.9% before discharge versus 99.2% at 12 months; P=NS). Over a mean follow-up of 24±13 months, conversion of spontaneously occurring ventricular tachyarrhythmias >200 bpm was identical (97.3%), despite a safety margin difference of 5.2±1.1 J for the 2-step group versus 20.8±4.2 J for maximal output.

Conclusions With a rigorous implantation algorithm, a safety margin of about 5 J is adequate for safe implantation of modern ICD systems.


Key Words: defibrillation • tachyarrhythmias • defibrillators, implantable • safety




This article has been cited by other articles:


Home page
EuropaceHome page
B. Lemke, T. Lawo, M. Zarse, A. Lubinski, U. Kreutzer, J. Mueller, A. Schuchert, S. Mitzenheim, D. Danilovic, T. Deneke, et al.
Patient-tailored implantable cardioverter defibrillator testing using the upper limit of vulnerability: the TULIP protocol
Europace, August 1, 2008; 10(8): 907 - 913.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. D. Day, B. Olshansky, S. Moore, S. Brown, K. Q. Stolen, D. R. Lerew, and for the INTRINSIC RV Study Investigators
High defibrillation energy requirements are encountered rarely with modern dual-chamber implantable cardioverter-defibrillator systems
Europace, March 1, 2008; 10(3): 347 - 350.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Passman and A. Kadish
Sudden Death Prevention With Implantable Devices
Circulation, July 31, 2007; 116(5): 561 - 571.
[Full Text] [PDF]


Home page
CirculationHome page
M. A. Wood and K. A. Ellenbogen
Follow-Up Defibrillator Testing for Antiarrhythmic Drugs: Probability and Uncertainty
Circulation, July 11, 2006; 114(2): 98 - 100.
[Full Text] [PDF]


Home page
CirculationHome page
S. H. Hohnloser, P. Dorian, R. Roberts, M. Gent, C. W. Israel, E. Fain, J. Champagne, and S. J. Connolly
Effect of Amiodarone and Sotalol on Ventricular Defibrillation Threshold: The Optimal Pharmacological Therapy in Cardioverter Defibrillator Patients (OPTIC) Trial
Circulation, July 11, 2006; 114(2): 104 - 109.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
D. A.M.J. Theuns, T. Szili-Torok, and L. J. Jordaens
Defibrillation efficacy testing: Long-term follow-up and mortality
Europace, January 1, 2005; 7(6): 509 - 515.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. A. Strickberger and G. J. Klein
Is defibrillation testing required for defibrillator implantation?
J. Am. Coll. Cardiol., July 7, 2004; 44(1): 88 - 91.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A. Buob, S. Siaplaouras, D. Tscholl, H.-J. Schäfers, M. Böhm, and J. Jung
Clinical value of routine predischarge testing after ICD-implantation
Europace, January 1, 2004; 6(2): 159 - 164.
[Abstract] [Full Text] [PDF]