Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2001;104:2436-2441
doi: 10.1161/hc4501.099317
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grube, E.
Right arrow Articles by Stertzer, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grube, E.
Right arrow Articles by Stertzer, S.
Related Collections
Right arrow Coronary circulation
Right arrow Catheter-based coronary and valvular interventions: other

(Circulation. 2001;104:2436.)
© 2001 American Heart Association, Inc.


Clinical Investigation and Reports

Prevention of Distal Embolization During Coronary Angioplasty in Saphenous Vein Grafts and Native Vessels Using Porous Filter Protection

Eberhard Grube, MD; Ulrich Gerckens, MD; Alan C. Yeung, MD; Sascha Rowold; Nicole Kirchhof, DVM; Jerry Sedgewick, BA; Jay S. Yadav, MD; Simon Stertzer, MD

From the Department of Cardiology/Angiology, Heart Center Siegburg, Siegburg, Germany (E.G., U.G., S.R.); the Division of Cardiovascular Medicine, Stanford University, Stanford, Calif (A.C.Y., S.S.); the University of Minnesota, Minneapolis (N.K., J.S.); and the Departments of Cardiology and Molecular Cardiology and the Joseph J. Jacobs Center for Thrombosis and Vascular Biology, The Cleveland Clinic Foundation, Cleveland, Ohio (J.S.Y.).

Correspondence to Eberhard Grube, MD, Department of Cardiology/Angiology, Heart Center Siegburg, 53721 Siegburg, Germany. E-mail GrubeE{at}aol.com

Background— Although distal embolization and the "no-reflow" phenomenon are well described in saphenous vein graft (SVG) interventions, the frequency, magnitude, and characterization of embolized debris have not been evaluated in routine coronary interventions. A unique embolus protection device described herein provides a means of containing and retrieving plaque material dislodged during percutaneous coronary interventions. This report details the first clinical experience of the effectiveness and safety of an emboli protection system in 11 SVG lesions and 15 native coronary artery lesions.

Methods and Results— The AngioGuard Emboli Capture Guidewire (Cordis) consists of a PTCA wire with an expandable filter at the distal tip. The porous membrane permits normal distal blood flow, while trapping potential emboli by filtration. After crossing the lesion, the filter is expanded, and routine angioplasty is performed over the same wire. Emboli retrieval is achieved by collapsing the filter and retracting the emboli capture wire (ECW). In 26 patients, standard angioplasty was performed over the ECW; 20 of these 26 patients received a stent. Collected debris was sent for histopathological analysis. Plaque debris was retrieved after native coronary and SVG interventions in all cases. The ECW was positioned and retrieved without complications. No major adverse events occurred. Myocardial infarctions and no-reflow were not observed.

Conclusions— The embolization of plaque fragments frequently occurs during coronary and SVG intervention. Distal embolization leading to microvascular obstruction and no-reflow could be successfully minimized by using the ECW.


Key Words: angioplasty • embolism • grafting




This article has been cited by other articles:


Home page
J Am Coll Cardiol IntvHome page
D. J. Kereiakes, M. A. Turco, J. Breall, N. Z. Farhat, R. L. Feldman, B. McLaurin, J. J. Popma, L. Mauri, P. Zimetbaum, J. Massaro, et al.
A Novel Filter-Based Distal Embolic Protection Device for Percutaneous Intervention of Saphenous Vein Graft Lesions: Results of the AMEthyst Randomized Controlled Trial
J. Am. Coll. Cardiol. Intv., June 1, 2008; 1(3): 248 - 257.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
C. Di Mario and G. Ferrante
Embolization: The "Dark Side" of Percutaneous Coronary Interventions
J. Am. Coll. Cardiol. Intv., June 1, 2008; 1(3): 277 - 278.
[Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
J. Kojuri, M. A Ostovan, N. Zamiri, A. Zolghadr Asli, M. A Bani Hashemi, and A. Borhani Haghighi
Procedural Outcome and Midterm Result of Carotid Stenting in High-Risk Patients
Asian Cardiovasc Thorac Ann, April 1, 2008; 16(2): 93 - 96.
[Abstract] [Full Text] [PDF]


Home page
J. Histochem. Cytochem.Home page
Q.-Y. Zhang, J.-B. Ge, J.-Z. Chen, J.-H. Zhu, L.-H. Zhang, C.-P. Lau, and H.-F. Tse
Mast Cell Contributes to Cardiomyocyte Apoptosis after Coronary Microembolization
J. Histochem. Cytochem., May 1, 2006; 54(5): 515 - 523.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Herrmann
Peri-procedural myocardial injury: 2005 update
Eur. Heart J., December 1, 2005; 26(23): 2493 - 2519.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. A. Gorog, R. A. Foale, and I. Malik
Distal Myocardial Protection During Percutaneous Coronary Intervention: When and Where?
J. Am. Coll. Cardiol., October 18, 2005; 46(8): 1434 - 1445.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
D. Dudek, W. Mielecki, A. Dziewierz, J. Legutko, and J. S. Dubiel
The role of thrombectomy and embolic protection devices
Eur. Heart J. Suppl., October 1, 2005; 7(suppl_I): I15 - I20.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Lefevre, E. Garcia, B. Reimers, I. Lang, C. di Mario, A. Colombo, F.-J. Neumann, M. V. Chavarri, P. Brunel, E. Grube, et al.
X-Sizer for Thrombectomy in Acute Myocardial Infarction Improves ST-Segment Resolution: Results of the X-Sizer in AMI for Negligible Embolization and Optimal ST Resolution (X AMINE ST) Trial
J. Am. Coll. Cardiol., July 19, 2005; 46(2): 246 - 252.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
Authors/Task Force Members, S. Silber, P. Albertsson, F. F. Aviles, P. G. Camici, A. Colombo, C. Hamm, E. Jorgensen, J. Marco, J.-E. Nordrehaug, et al.
Guidelines for Percutaneous Coronary Interventions: The Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology
Eur. Heart J., April 2, 2005; 26(8): 804 - 847.
[Full Text] [PDF]


Home page
StrokeHome page
A. Kastrup, K. Groschel, J. B. Schulz, T. Nagele, and U. Ernemann
Clinical Predictors of Transient Ischemic Attack, Stroke, or Death Within 30 Days of Carotid Angioplasty and Stenting
Stroke, April 1, 2005; 36(4): 787 - 791.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
J. S. Yadav, M. H. Wholey, R. E. Kuntz, P. Fayad, B. T. Katzen, G. J. Mishkel, T. K. Bajwa, P. Whitlow, N. E. Strickman, M. R. Jaff, et al.
Protected Carotid-Artery Stenting versus Endarterectomy in High-Risk Patients
N. Engl. J. Med., October 7, 2004; 351(15): 1493 - 1501.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Angelini, P. Rubartelli, F. Mistrorigo, M. Della Barbera, F. Abbadessa, M. Vischi, G. Thiene, and S. Chierchia
Distal Protection With a Filter Device During Coronary Stenting in Patients With Stable and Unstable Angina
Circulation, August 3, 2004; 110(5): 515 - 521.
[Abstract] [Full Text] [PDF]


Home page
J CARDIOVASC PHARMACOL THERHome page
T. Reffemann and R. A. Kloner
Microvascular Alterations After Temporary Coronary Artery Occlusion: The No-Reflow Phenomenon
Journal of Cardiovascular Pharmacology and Therapeutics, July 1, 2004; 9(3): 163 - 172.
[Abstract] [PDF]


Home page
HeartHome page
J. K French and H. D White
Clinical implications of the new definition of myocardial infarction
Heart, January 1, 2004; 90(1): 99 - 106.
[Full Text] [PDF]


Home page
CirculationHome page
S. Lee, Y. Otsuji, S. Minagoe, S. Hamasaki, K. Toyonaga, M. Negishi, M. Tsurugida, H. Toda, and C. Tei
Noninvasive Evaluation of Coronary Reperfusion by Transthoracic Doppler Echocardiography in Patients With Anterior Acute Myocardial Infarction Before Coronary Intervention
Circulation, December 2, 2003; 108(22): 2763 - 2768.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Napodano, G. Pasquetto, S. Sacca, C. Cernetti, V. Scarabeo, P. Pascotto, and B. Reimers
Intracoronary thrombectomy improves myocardial reperfusion in patients undergoing direct angioplasty for acute myocardial infarction
J. Am. Coll. Cardiol., October 15, 2003; 42(8): 1395 - 1402.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
H.-K. Yip, C.-J. Wu, H.-W. Chang, Y.-K. Hsieh, C.-Y. Fang, S.-M. Chen, and M.-C. Chen
Impact of Tirofiban on Angiographic Morphologic Features of High-Burden Thrombus Formation During Direct Percutaneous Coronary Intervention and Short-term Outcomes
Chest, September 1, 2003; 124(3): 962 - 968.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
G. W. Stone, C. Rogers, J. Hermiller, R. Feldman, P. Hall, R. Haber, A. Masud, P. Cambier, R. P. Caputo, M. Turco, et al.
Randomized Comparison of Distal Protection With a Filter-Based Catheter and a Balloon Occlusion and Aspiration System During Percutaneous Intervention of Diseased Saphenous Vein Aorto-Coronary Bypass Grafts
Circulation, August 5, 2003; 108(5): 548 - 553.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
U. Limbruno, A. Micheli, M. De Carlo, G. Amoroso, R. Rossini, C. Palagi, V. Di Bello, A. S. Petronio, G. Fontanini, and M. Mariani
Mechanical Prevention of Distal Embolization During Primary Angioplasty: Safety, Feasibility, and Impact on Myocardial Reperfusion
Circulation, July 15, 2003; 108(2): 171 - 176.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. W. O'Neill
"Watchful waiting"after thrombolysis: It's time for a re-evaluation
J. Am. Coll. Cardiol., July 2, 2003; 42(1): 17 - 19.
[Full Text] [PDF]


Home page
CirculationHome page
M. Roffi, D. Mukherjee, D. P. Chew, D. L. Bhatt, L. Cho, M. A. Robbins, K. M. Ziada, D. M. Brennan, S. G. Ellis, and E. J. Topol
Lack of Benefit From Intravenous Platelet Glycoprotein IIb/IIIa Receptor Inhibition as Adjunctive Treatment for Percutaneous Interventions of Aortocoronary Bypass Grafts: A Pooled Analysis of Five Randomized Clinical Trials
Circulation, December 10, 2002; 106(24): 3063 - 3067.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. W. Stone, C. Rogers, S. Ramee, C. White, R. E. Kuntz, J. J. Popma, J. George, S. Almany, and S. Bailey
Distal filter protection during saphenous vein graft stenting: Technical and clinical correlates of efficacy
J. Am. Coll. Cardiol., November 20, 2002; 40(10): 1882 - 1888.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J.-i. Kotani, S. Nanto, G. S. Mintz, M. Kitakaze, T. Ohara, T. Morozumi, S. Nagata, and M. Hori
Plaque Gruel of Atheromatous Coronary Lesion May Contribute to the No-Reflow Phenomenon in Patients With Acute Coronary Syndrome
Circulation, September 24, 2002; 106(13): 1672 - 1677.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
T. Reffelmann and R. A. Kloner
Microvascular reperfusion injury: rapid expansion of anatomic no reflow during reperfusion in the rabbit
Am J Physiol Heart Circ Physiol, September 1, 2002; 283(3): H1099 - H1107.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
M. Thielmann, H. Dorge, C. Martin, S. Belosjorow, U. Schwanke, A. van de Sand, I. Konietzka, A. Buchert, A. Kruger, R. Schulz, et al.
Myocardial Dysfunction With Coronary Microembolization: Signal Transduction Through a Sequence of Nitric Oxide, Tumor Necrosis Factor-{alpha}, and Sphingosine
Circ. Res., April 19, 2002; 90(7): 807 - 813.
[Abstract] [Full Text] [PDF]


Home page
Journal Watch CardiologyHome page
Reducing Distal Embolization with Filter Protection
Journal Watch Cardiology, January 18, 2002; 2002(118): 4 - 4.
[Full Text]


Home page
Circ. Res.Home page
M. Thielmann, H. Dorge, C. Martin, S. Belosjorow, U. Schwanke, A. van de Sand, I. Konietzka, A. Buchert, A. Kruger, R. Schulz, et al.
Myocardial Dysfunction With Coronary Microembolization: Signal Transduction Through a Sequence of Nitric Oxide, Tumor Necrosis Factor-{alpha}, and Sphingosine
Circ. Res., April 19, 2002; 90(7): 807 - 813.
[Abstract] [Full Text] [PDF]