Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2001;104:1779-1784
doi: 10.1161/hc4001.097057
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by den Boer, A.
Right arrow Articles by Roelandt, J. R.T.C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by den Boer, A.
Right arrow Articles by Roelandt, J. R.T.C.
Related Collections
Right arrow Catheter-based coronary interventions: stents
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC

(Circulation. 2001;104:1779.)
© 2001 American Heart Association, Inc.


Clinical Investigation and Reports

Real-Time Quantification and Display of Skin Radiation During Coronary Angiography and Intervention

Ad den Boer, BS; Pim J. de Feijter, MD; Patrick W. Serruys, MD; Jos R.T.C. Roelandt, MD

From the Thoraxcenter, Department of Cardiology, Erasmus Medical Center, Rotterdam, Netherlands.

Correspondence to Ad den Boer, Department of Cardiology, Thoraxcenter BD 428, PO Box 2040, 3000 GR Rotterdam, Netherlands. E-mail denboer{at}card.azr.nl

Background— Radiographically guided investigations may be associated with excessive radiation exposure, which may cause skin injuries. The purpose of this study was to develop and test a system that measures in real time the dose applied to each 1-cm2 area of skin, taking into account the movement of the x-ray source and changes in the beam characteristics. The goal of such a system is to help prevent high doses that might cause skin injury.

Methods and Results— The entrance point, beam size, and dose at the skin of the patient were calculated by use of the geometrical settings of gantry, investigation table, and x-ray beam and an ionization chamber. The data are displayed graphically. Three hundred twenty-two sequential cardiac investigations in adult patients were analyzed. The mean peak entrance dose per investigation was 0.475 Gy to a mean skin area of 8.2 cm2. The cumulative KERMA-area product per investigation was 52.2 Gy/cm2 (25.4 to 99.2 Gy/cm2), and the mean entrance beam size at the skin was 49.2 cm2. Twenty-eight percent of the patients (90/322) received a maximum dose of <1 Gy to a small skin area ({approx}6 cm2), and 13.5% of the patients (42/322) received a maximum dose of >2 Gy.

Conclusions— Monitoring of the dose distribution at the skin will alert the operator to the development of high-dose areas; by use of other gantry settings with nonoverlapping entrance fields, different generator settings, and extra collimation, skin lesion can be avoided.


Key Words: radiography • catheterization • dosage




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. Chida, Y. Kagaya, H. Saito, Y. Takai, S. Takahashi, S. Yamada, M. Kohzuki, and M. Zuguchi
Total Entrance Skin Dose: An Effective Indicator of Maximum Radiation Dose to the Skin During Percutaneous Coronary Intervention
Am. J. Roentgenol., October 1, 2007; 189(4): W224 - W227.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
R E Morrell and A T Rogers
A mathematical model for patient skin dose assessment in cardiac catheterization procedures.
Br. J. Radiol., September 1, 2006; 79(945): 756 - 761.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Suzuki, S. Furui, H. Kohtake, T. Takeshita, M. Suzuki, K. Kozuma, Y. Yamamoto, and T. Isshiki
Radiosensitive Functional Dye: Clinical Application for Estimation of Patient Skin Dose
Radiology, May 1, 2006; 239(2): 541 - 546.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Chida, H. Saito, H. Otani, M. Kohzuki, S. Takahashi, S. Yamada, K. Shirato, and M. Zuguchi
Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures.
Am. J. Roentgenol., March 1, 2006; 186(3): 774 - 778.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. S. Storm, D. L. Miller, L. J. Hoover, J. D. Georgia, and T. Bivens
Radiation Doses from Venous Access Procedures
Radiology, March 1, 2006; 238(3): 1044 - 1050.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Vano, L. Gonzalez, E. Guibelalde, P. Aviles, J. M. Fernandez, C. Prieto, and C. Galvan
Evaluation of risk of deterministic effects in fluoroscopically guided procedures
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 190 - 194.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
R. Padovani, G. Bernardi, E. Quai, M. Signor, H. S. Toh, G. Morocutti, and L. Spedicato
Retrospective evaluation of occurrence of skin injuries in interventional cardiac procedures
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 247 - 250.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. Geleijns and J. Wondergem
X-ray imaging and the skin: radiation biology, patient dosimetry and observed effects
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 121 - 125.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. Bacher, E. Bogaert, R. Lapere, D. De Wolf, and H. Thierens
Patient-Specific Dose and Radiation Risk Estimation in Pediatric Cardiac Catheterization
Circulation, January 4, 2005; 111(1): 83 - 89.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Guibelalde, L Gonzalez, and E Vano
Suitability of resin-coated photographic paper for skin dose measurement during fluoroscopically-guided X-ray procedures
Br. J. Radiol., October 1, 2004; 77(922): 871 - 875.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
E Kuon, J Birkel, M Schmitt, and J B Dahm
Radiation exposure benefit of a lead cap in invasive cardiology
Heart, October 1, 2003; 89(10): 1205 - 1210.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Kuon, C Glaser, and J B Dahm
Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures
Br. J. Radiol., June 1, 2003; 76(906): 406 - 413.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Vano, C Prieto, J M Fernandez, L Gonzalez, M Sabate, and C Galvan
Skin dose and dose-area product values in patients undergoing intracoronary brachytherapy
Br. J. Radiol., January 1, 2003; 76(901): 32 - 38.
[Abstract] [Full Text] [PDF]