Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2001;103:3081-3085

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tang, A. S.L.
Right arrow Articles by Connolly, S. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tang, A. S.L.
Right arrow Articles by Connolly, S. J.
Related Collections
Right arrow Pacemaker

(Circulation. 2001;103:3081.)
© 2001 American Heart Association, Inc.


Clinical Investigation and Reports

Relationship Between Pacemaker Dependency and the Effect of Pacing Mode on Cardiovascular Outcomes

Anthony S.L. Tang, MD; Robin S. Roberts, MTech; Charles Kerr, MD; Anne M. Gillis, MD; Martin S. Green, MD; Mario Talajic, MD; Salim Yusuf, MD; Hoshiar Abdollah, MB ChB; Michael Gent, DSc; Stuart J. Connolly, MD; and the Canadian Trial of Physiologic Pacing (CTOPP) Investigators

From the University of Ottawa Heart Institute, Ottawa, Ontario (A.S.L.T., M.S.G.); McMaster University, Hamilton, Ontario (R.S.R., S.YL, M.G., S.J.C.); the University of British Columbia, Vancouver, British Colombia (C.K.); the University of Calgary, Calgary, Alberta (A.M.G.); Montreal Heart Institute, Montreal, Province of Quebec (M.T.); and Queen’s University, Kingston, Ontario (H.A.), Canada.

Correspondence to Dr Anthony S.L. Tang, University of Ottawa Heart Institute, 40 Ruskin St., Ottawa, Ontario, Canada, K1Y4W7. E-mail atang{at}ottawaheart.ca

Background—A recently completed trial, the Canadian Trial of Physiological Pacing (CTOPP), showed that physiological pacing did not significantly reduce mortality, stroke, or heart failure hospitalization, but it did show that atrial fibrillation occurred less frequently in patients with physiological pacing. Many pacemaker patients experience only transient bradyarrhythmias with an adequate unpaced heart rate (UHR) and are not pacemaker-dependent. The purpose of the present analysis was to determine if pacemaker-dependent patients have an increased benefit from physiological pacing compared with non–pacemaker-dependent patients.

Methods and Results—Of 2568 patients included in the CTOPP trial, 2244 patients had a pacemaker dependency test performed at the first follow-up visit. The yearly event rate of cardiovascular death or stroke steadily increased with decreasing UHR in the ventricular pacing group, but it remained constant in the physiological pacing group. When the patients were subdivided to UHR <=60 bpm or >60 bpm, there was an interaction between pacing mode treatment and UHR subgroup. The Kaplan-Meier plot confirmed a physiological pacing advantage only in the UHR <=60 bpm subgroup. This differential effect was also present for the outcomes of cardiovascular death and total mortality.

Conclusions—This study demonstrated that UHR at first follow-up has an important influence on how pacing mode selection affects cardiovascular death and total mortality. Pacemaker-dependent patients with low UHR will probably be paced frequently and will likely benefit from physiological pacing. In contrast, non–pacemaker-dependent patients will likely be paced infrequently and may not benefit from physiological pacing.


Key Words: pacemakers • trials • mortality




This article has been cited by other articles:


Home page
EuropaceHome page
P. Korantzopoulos, K. P. Letsas, G. Grekas, and J. A. Goudevenos
Pacemaker dependency after implantation of electrophysiological devices
Europace, September 1, 2009; 11(9): 1151 - 1155.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. J. Jokinen, A. K. Turpeinen, O. Pitkanen, M. J. Hippelainen, and J. E.K. Hartikainen
Pacemaker Therapy After Tricuspid Valve Operations: Implications on Mortality, Morbidity, and Quality of Life.
Ann. Thorac. Surg., June 1, 2009; 87(6): 1806 - 1814.
[Abstract] [Full Text] [PDF]


Home page
ESC Textbook of Cardiovascular MedicineHome page
P. E. Vardas, H. E. Mavrakis, and W. D. Toff
CHAPTER 27 Bradycardia
ESC Textbook of Cardiovascular Medicine, January 1, 2009; 2(1): med-9780199566990-chapter - med-9780199566990-chapter.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
C. M. Fored, F. Granath, F. Gadler, P. Blomqvist, J. Rynder, C. Linde, A. Ekbom, and M. Rosenqvist
Atrial vs. dual-chamber cardiac pacing in sinus node disease: a register-based cohort study
Europace, July 1, 2008; 10(7): 825 - 831.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
Authors/Task Force Members, P. E. Vardas, A. Auricchio, J.-J. Blanc, J.-C. Daubert, H. Drexler, H. Ector, M. Gasparini, C. Linde, F. B. Morgado, et al.
Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm Association
Europace, October 1, 2007; 9(10): 959 - 998.
[Full Text] [PDF]


Home page
Eur Heart JHome page
Authors/Task Force Members, P. E. Vardas, A. Auricchio, J.-J. Blanc, J.-C. Daubert, H. Drexler, H. Ector, M. Gasparini, C. Linde, F. B. Morgado, et al.
Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm Association
Eur. Heart J., September 2, 2007; 28(18): 2256 - 2295.
[Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
S. D.R. Thackray, G. A. Wright, K. K.A. Witte, N. P. Nikitin, A. C. Tweddel, A. L. Clark, and J. G.F. Cleland
The effect of ventricular pacing on measurements of left ventricular function: A comparison between echocardiographic methods and with radionuclide ventriculography
Eur J Echocardiogr, August 1, 2006; 7(4): 284 - 292.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. S. Healey, W. D. Toff, G. A. Lamas, H. R. Andersen, K. E. Thorpe, K. A. Ellenbogen, K. L. Lee, A. M. Skene, E. B. Schron, J. D. Skehan, et al.
Cardiovascular Outcomes With Atrial-Based Pacing Compared With Ventricular Pacing: Meta-Analysis of Randomized Trials, Using Individual Patient Data
Circulation, July 4, 2006; 114(1): 11 - 17.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. Caro, A. Ward, and J. Moller
Modelling the health benefits and economic implications of implanting dual-chamber vs. single-chamber ventricular pacemakers in the UK
Europace, June 1, 2006; 8(6): 449 - 455.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Silberbauer, N. Sulke, C. W. Israel, N. Edvardsson, L. Mont, J. Kautzner, P. Ritter, and A. J. Camm
Pacemaker selection: time for a rethinking of complex pacing systems
Eur. Heart J., May 1, 2006; 27(9): 1126 - 1127.
[Full Text] [PDF]


Home page
JAMAHome page
P. A. Gould, A. D. Krahn, and for the Canadian Heart Rhythm Society Working Grou
Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories.
JAMA, April 26, 2006; 295(16): 1907 - 1911.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. D.R. Thackray, K. Witte, J. Ghosh, N. Nikitin, A. Anderson, A. Rigby, K. Goode, A. L. Clark, and J. G.F. Cleland
N-terminal brain natriuretic peptide as a screening tool for heart failure in the pacemaker population
Eur. Heart J., February 2, 2006; 27(4): 447 - 453.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. S. Link, A. S. Hellkamp, N. A. M. Estes III, E. J. Orav, K. A. Ellenbogen, B. Ibrahim, A. Greenspon, C. Rizo-Patron, L. Goldman, K. L. Lee, et al.
High incidence of pacemaker syndrome in patients with sinus node dysfunction treated with ventricular-based pacing in the Mode Selection Trial (MOST)
J. Am. Coll. Cardiol., June 2, 2004; 43(11): 2066 - 2071.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
L Kristensen, J C Nielsen, P T Mortensen, O L Pedersen, A K Pedersen, and H R Andersen
Incidence of atrial fibrillation and thromboembolism in a randomised trial of atrial versus dual chamber pacing in 177 patients with sick sinus syndrome
Heart, June 1, 2004; 90(6): 661 - 666.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. R. Kerr, S. J. Connolly, H. Abdollah, R. S. Roberts, M. Gent, S. Yusuf, A. M. Gillis, A. S.L. Tang, M. Talajic, G. J. Klein, et al.
Canadian Trial of Physiological Pacing: Effects of Physiological Pacing During Long-Term Follow-Up
Circulation, January 27, 2004; 109(3): 357 - 362.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. Brunner, M. Olschewski, A. Geibel, C. Bode, and M. Zehender
Long-term survival after pacemaker implantation: Prognostic importance of gender and baseline patient characteristics
Eur. Heart J., January 1, 2004; 25(1): 88 - 95.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. D.R. Thackray, K. K.A. Witte, N. P. Nikitin, A. L. Clark, G. C. Kaye, and J. G.F. Cleland
The prevalence of heart failure and asymptomatic left ventricular systolic dysfunction in a typical regional pacemaker population
Eur. Heart J., June 2, 2003; 24(12): 1143 - 1152.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. M. Gillis, C. Unterberg-Buchwald, H. Schmidinger, S. Massimo, K. Wolfe, D. J. Kavaney, M. F. Otterness, S. H. Hohnloser, and GEM III AT Worldwide Investigators
Safety and efficacy of advanced atrial pacing therapies for atrial tachyarrhythmias in patients with a new implantable dual chamber cardioverter-defibrillator
J. Am. Coll. Cardiol., November 6, 2002; 40(9): 1653 - 1659.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J.C. Daubert and C. Leclercq
Upgrading from ventricular to physiological pacing: is it worth it?
Eur. Heart J., March 2, 2002; 23(6): 437 - 441.
[Full Text] [PDF]