Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1999;100:2146-2152

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Babbs, C. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Babbs, C. F.
Related Collections
Right arrow Information technology
Right arrow CPR and emergency cardiac care
Right arrow Coronary circulation

(Circulation. 1999;100:2146.)
© 1999 American Heart Association, Inc.


Clinical Investigation and Reports

CPR Techniques That Combine Chest and Abdominal Compression and Decompression

Hemodynamic Insights From a Spreadsheet Model

Charles F. Babbs, MD, PhD

From Indiana University School of Medicine and the Department of Basic Medical Sciences, Purdue University, West Lafayette, Ind.

Correspondence to Charles F. Babbs, MD, PhD, Basic Medical Sciences, 1246 Lynn Hall, Purdue University, West Lafayette, IN 47907-1246. E-mail babbs{at}vet.purdue.edu

Background—This study was done to elucidate mechanisms by which newer cardiopulmonary resuscitation (CPR) techniques, including interposed abdominal compression (IAC), active compression-decompression (ACD), and Lifestick CPR, augment systemic perfusion pressure and forward flow and to compare the 3 techniques in the same test system.

Methods and Results—Mathematical models describing hemodynamics of the adult human circulation during cardiac arrest and CPR were created and exercised by use of spreadsheet software. Assumptions of the models are limited to normal human anatomy and physiology, the definition of compliance (volume change/pressure change), and Ohm’s law (flow=pressure/resistance). Standard CPR generates 1.3 L/min forward and 25 mm Hg systemic perfusion pressure. In otherwise identical models, IAC-CPR generates 2.4 L/min and 45 mm Hg; ACD-CPR, 1.6 L/min and 30 mm Hg; and Lifestick CPR, which combines IAC and ACD, 3.1 L/min and 58 mm Hg. Augmented CPR techniques work by enhanced priming of either chest or abdominal pump mechanisms.

Conclusions—Adjunctive maneuvers, combined with conventional chest compression, can produce substantial hemodynamic benefit in CPR by credible physiological mechanisms.


Key Words: blood flow • cardiopulmonary resuscitation • computers • heart arrest • Lifestick • mechanics




This article has been cited by other articles:


Home page
CirculationHome page
Part 4: Advanced Life Support
Circulation, November 29, 2005; 112(22_suppl): III-25 - III-54.
[Full Text] [PDF]


Home page
CirculationHome page
J. Fisher and C. F. Babbs
The Naming of Jugular Venous Valves Response
Circulation, December 12, 2000; 102 (24): e181 - e181.
[Full Text] [PDF]