Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Published Online
on October 25, 2004

Circulation. 2004
Published online before print October 25, 2004, doi: 10.1161/01.CIR.0000147275.50550.68
A more recent version of this article appeared on November 16, 2004
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
110/20/3199    most recent
01.CIR.0000147275.50550.68v2
01.CIR.0000147275.50550.68v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lemos, P. A.
Right arrow Articles by Serruys, P. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lemos, P. A.
Right arrow Articles by Serruys, P. W.
Right arrowPubmed/NCBI databases
*Compound via MeSH
*Substance via MeSH
Related Collections
Right arrow Catheter-based coronary interventions: stents
Right arrow Restenosis

Submitted on December 1, 2003
Revised on June 30, 2004
Accepted on July 14, 2004

Comparison of Late Luminal Loss Response Pattern After Sirolimus-Eluting Stent Implantation or Conventional Stenting

Pedro A. Lemos MD, PhD, Nestor Mercado , Ron T. van Domburg PhD, Richard E. Kuntz MD, William W. O’Neill MD, and Patrick W. Serruys MD, PhD*

From the Heart Institute (InCor), University of Sao Paulo Medical School, Sao Paulo, Brazil (P.A.L.); Erasmus Medical Center, Rotterdam, the Netherlands (P.T.v.D., P.W.S.); William Beaumont Hospital, Royal Oak, Mich (N.M., W.W.O.); and Brigham and Women’s Hospital, Boston, Mass (R.E.K.).

* To whom correspondence should be addressed. E-mail: p.w.j.c.serruys{at}erasmusmc.nl.

Background--We investigated the pattern of late luminal loss after sirolimus-eluting or bare stent implantation.

Methods and Results--The study population comprised 238 patients treated with sirolimus-eluting stents and 526 patients treated with conventional stents. The distribution of late loss of sirolimus stents was largely skewed to the right and differed from the distribution for bare stents. When divided according to the presence of binary restenosis (diameter stenosis >50%), restenotic lesions in the bare stent group (26.0%) had a late loss of 1.40±0.64 mm and in the sirolimus group (7.9%) of 1.16±0.76 mm. Nonrestenotic lesions in the bare stent group had a late loss of 0.58±0.44 mm, whereas the late loss of nonrestenotic lesions in the sirolimus group remained close to zero (-0.05±0.33 mm). Differences between poststenting and follow-up measurements in the sirolimus group (late loss) resembled variations observed in repeated angiographic measurements, as assessed from a random sample of 30 segments measured repeatedly. After multivariate adjustment, stent type did not influence the degree of late loss in restenotic lesions. However, nonrestenotic bare stents had a significantly larger estimated luminal loss (0.58 mm; 95% CI, 0.52 to 0.65) than sirolimus-eluting stents, for which the predicted late loss was almost 0 (-0.04 mm; 95% CI, -0.10 to 0.02).

Conclusions--The pattern of late loss after sirolimus-eluting stent implantation follows a peculiar behavior, different from lesions treated with conventional stents. Whether this is explained by an unusual statistical distribution or a biological all-or-none response of restenosis after sirolimus-eluting stenting remains to be investigated.


Key words: restenosis • statistics • stents




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
S. J. Pocock, A. J. Lansky, R. Mehran, J. J. Popma, M. P. Fahy, Y. Na, G. Dangas, J. W. Moses, T. Pucelikova, D. E. Kandzari, et al.
Angiographic surrogate end points in drug-eluting stent trials: a systematic evaluation based on individual patient data from 11 randomized, controlled trials.
J. Am. Coll. Cardiol., January 1, 2008; 51(1): 23 - 32.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. Cosgrave, G. Melzi, S. Corbett, G. G.L. Biondi-Zoccai, P. Agostoni, R. Babic, F. Airoldi, A. Chieffo, G. M. Sangiorgi, M. Montorfano, et al.
Comparable Clinical Outcomes With Paclitaxel- and Sirolimus-Eluting Stents in Unrestricted Contemporary Practice
J. Am. Coll. Cardiol., June 19, 2007; 49(24): 2320 - 2328.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Camenzind, P. G. Steg, and W. Wijns
A Cause for Concern
Circulation, March 20, 2007; 115(11): 1440 - 1455.
[Full Text] [PDF]


Home page
NEJMHome page
J. C.J. Sun, J. W. Eikelboom, P. Agostoni, G. M. Sangiorgi, G. G. Biondi-Zoccai, B. Scheller, M. Bohm, and E. Camenzind
Treatment of Restenosis with a Paclitaxel-Coated Balloon Catheter
N. Engl. J. Med., March 8, 2007; 356(10): 1071 - 1073.
[Full Text] [PDF]


Home page
CirculationHome page
J. Fajadet, W. Wijns, G.-J. Laarman, K.-H. Kuck, J. Ormiston, T. Munzel, J. J. Popma, P. J. Fitzgerald, R. Bonan, R. E. Kuntz, et al.
Randomized, Double-Blind, Multicenter Study of the Endeavor Zotarolimus-Eluting Phosphorylcholine-Encapsulated Stent for Treatment of Native Coronary Artery Lesions: Clinical and Angiographic Results of the ENDEAVOR II Trial
Circulation, August 22, 2006; 114(8): 798 - 806.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R. Seabra-Gomes
Percutaneous coronary interventions with drug eluting stents for diabetic patients.
Heart, March 1, 2006; 92(3): 410 - 419.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. G. Ellis, J. J. Popma, G. W. Stone, and M. E. Russell
Restenosis, Statistics, and Reasonable Inferences
J. Am. Coll. Cardiol., January 17, 2006; 47(2): 470 - 471.
[Full Text] [PDF]


Home page
CirculationHome page
M. Sabate, P. Jimenez-Quevedo, D. J. Angiolillo, J. A. Gomez-Hospital, F. Alfonso, R. Hernandez-Antolin, J. Goicolea, C. Banuelos, J. Escaned, R. Moreno, et al.
Randomized Comparison of Sirolimus-Eluting Stent Versus Standard Stent for Percutaneous Coronary Revascularization in Diabetic Patients: The Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial
Circulation, October 4, 2005; 112(14): 2175 - 2183.
[Abstract] [Full Text] [PDF]