Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Published Online
on January 13, 2003

Circulation. 2003
Published online before print January 13, 2003, doi: 10.1161/01.CIR.0000047210.07839.7B
A more recent version of this article appeared on February 11, 2003
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
107/5/785    most recent
01.CIR.0000047210.07839.7Bv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suematsu, Y.
Right arrow Articles by Murakami, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suematsu, Y.
Right arrow Articles by Murakami, A.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Heart Surgery
Related Collections
Right arrow Pediatric and congenital heart disease, including cardiovascular surgery

Submitted on August 21, 2002
Revised on October 24, 2002
Accepted on October 28, 2002

Beating Atrial Septal Defect Closure Monitored by Epicardial Real-Time Three-Dimensional Echocardiography Without Cardiopulmonary Bypass

Yoshihiro Suematsu MD*, Shinichi Takamoto MD, Yukihiro Kaneko MD, Toshiya Ohtsuka MD, Hiroo Takayama MD, Yutaka Kotsuka MD, and Arata Murakami MD

From the Department of Cardiothoracic Surgery, University of Tokyo, Tokyo, Japan.

* To whom correspondence should be addressed. E-mail: suematsu-THO{at}h.u-tokyo.ac.jp.

Background--We assessed the feasibility of beating atrial septal defect (ASD) closure monitored by real-time 3D echocardiography (RT3DE).

Methods and Results--RT3DE was developed with prototype ultrasound equipment consisting of a high-speed 3D rendering unit with a frame rate of 5 to 10 frames/s. We also developed a prototype semiautomatic suture device and suture cutting system. In the experiment, 12 mongrel dogs were anesthetized, and after median sternotomy, the echo probe was applied directly to the surface of the right atrium. Three surgical maneuvers (balloon atrial septectomy, enlargement of the ASD, and ASD closure) were performed through the atrial port inserted into the right atrial appendage. The heart was then excised, and the area of the ASD measured by RT3DE was compared with its area measured directly. The ASD was successfully closed in all experimental animals except the first 2. Examination of the excised heart showed that none of the sutures were loose. The mean area of the ASD was 82.5±38.6 mm2 when measured by RT3DE and 81.6±38.2 mm2 when measured directly, and there was a significant correlation between the areas measured by RT3DE and those measured directly (echo measurements=1.007xdirect measurements+0.337; P<0.0001). A Bland-Altman analysis revealed close agreement between the results obtained by the 2 methods (7.807 mm2 upper and -6.024 mm2 lower limit of agreement).

Conclusions--Introduction of RT3DE, a semiautomatic suture device, and a suture cutting system made beating ASD closure without cardiopulmonary bypass possible.


Key words: cardiopulmonary bypass • echocardiography • heart septal defects




This article has been cited by other articles:


Home page
ICVTSHome page
M. Hisagi, Y. Suematsu, A. Masuzawa, M. Ono, N. Motomura, and S. Takamoto
Image-guided surgical repair of ventricular septal rupture using self-expanding device
Interactive CardioVascular and Thoracic Surgery, June 1, 2009; 8(6): 602 - 605.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. V. Vasilyev, I. Melnychenko, K. Kitahori, F. P. Freudenthal, A. Phillips, R. Kozlik-Feldmann, I. S. Salgo, P. J. del Nido, and E. A. Bacha
Beating-heart patch closure of muscular ventricular septal defects under real-time three-dimensional echocardiographic guidance: A preclinical study
J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 603 - 609.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Handke, G. Heinrichs, U. Moser, F. Hirt, F. Margadant, F. Gattiker, C. Bode, and A. Geibel
Transesophageal Real-Time Three-Dimensional Echocardiography: Methods and Initial In Vitro and Human In Vivo Studies
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2070 - 2076.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. M. Lang, V. Mor-Avi, L. Sugeng, P. S. Nieman, and D. J. Sahn
Three-Dimensional Echocardiography: The Benefits of the Additional Dimension
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2053 - 2069.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Suematsu, B. N. Mora, T. Mihaljevic, and P. J. del Nido
Totally Endoscopic Robotic-Assisted Repair of Patent Ductus Arteriosus and Vascular Ring in Children
Ann. Thorac. Surg., December 1, 2005; 80(6): 2309 - 2313.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Y. Suematsu, J. F. Martinez, B. K. Wolf, G. R. Marx, J. A. Stoll, P. E. DuPont, R. D. Howe, J. K. Triedman, and P. J. del Nido
Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: Atrial septal defect closure in a swine model
J. Thorac. Cardiovasc. Surg., November 1, 2005; 130(5): 1348 - 1357.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
K. Orihashi, T. Sueda, K. Okada, K. Imai, K. Ban, and M. Hamamoto
Real-time three dimensional echo-guided closure of atrial septal defect: an experimental model
Interactive CardioVascular and Thoracic Surgery, October 1, 2005; 4(5): 391 - 395.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Y. Suematsu, G. R. Marx, J. A. Stoll, P. E. DuPont, R. O. Cleveland, R. D. Howe, J. K. Triedman, T. Mihaljevic, B. N. Mora, B. J. Savord, et al.
Three-dimensional echocardiography-guided beating-heart surgery without cardiopulmonary bypass: A feasibility study
J. Thorac. Cardiovasc. Surg., October 1, 2004; 128(4): 579 - 587.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. E. Weyman
The year in echocardiography
J. Am. Coll. Cardiol., January 7, 2004; 43(1): 140 - 148.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Z. Amin, D. A. Danford, J. Lof, K. F. Duncan, and S. Froemming
Intraoperative device closure of perimembranous ventricular septal defects without cardiopulmonary bypass: Preliminary results with the perventricular technique
J. Thorac. Cardiovasc. Surg., January 1, 2004; 127(1): 234 - 241.
[Abstract] [Full Text] [PDF]