Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Published Online
on April 1, 2002

Circulation. 2002
Published online before print April 1, 2002, doi: 10.1161/01.CIR.0000015852.60212.DB
A more recent version of this article appeared on April 16, 2002
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
105/15/1772    most recent
01.CIR.0000015852.60212.DBv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Buecker, A.
Right arrow Articles by Günther, R. W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Buecker, A.
Right arrow Articles by Günther, R. W.
Related Collections
Right arrow CT and MRI

Submitted on January 8, 2002
Revised on February 21, 2002
Accepted on February 25, 2002

Artifact-Free In-Stent Lumen Visualization by Standard Magnetic Resonance Angiography Using a New Metallic Magnetic Resonance Imaging Stent

Arno Buecker MD*, Elmar Spuentrup MD, Alexander Ruebben MD, and Rolf W. Günther MD

From the Clinic of Diagnostic Radiology, University of Technology Aachen, Germany.

* To whom correspondence should be addressed. E-mail: buecker{at}rad.rwth-aachen.de.

Background—Metallic stents cause susceptibility and radiofrequency artifacts on MR images, which, up to now, have not allowed for complete visualization of the stent lumen by MR angiography. The aim of this study was to investigate the potential of a new dedicated renal MRI stent for artifact-free in-stent lumen visualization in vitro and in a swine model.

Methods and Results—In vitro investigations were performed with prototypes of balloon-expandable Aachen Resonance Renal MRI Stents dilated to diameters of 3 to 6 mm and placed in an aqueous gadolinium solution (1:25). Phase-contrast and contrast-enhanced T1-weighted gradient echo images were acquired. Renal MRI stents (n=12) were deployed in the renal arteries of 6 pigs. Renal arteries were examined with phase-contrast angiography and with flow measurements before and after stent placement in the stented area, respectively. Additionally, a contrast-enhanced, T1-weighted, spoiled-gradient echo sequence after administration of 0.2 mmol gadolinium-DTPA/kg body weight was performed after stent placement. The visibility of artifacts was analyzed on in vitro and in vivo images by two investigators who knew the stent positions. Stent positions were determined visually (in vitro) or by x-ray angiography (animal experiments). No artifacts were detected independent of the applied imaging sequence and the stent orientation to the main magnetic field.

Conclusion—The examined prototypes of fully MR-compatible MRI stents allow artifact-free visualization of the stent lumen with phase-contrast and contrast-enhanced T1-weighted angiography, as well as phase-contrast flow measurements in the stented area.


Key words: magnetic resonance imaging • angiography • stents




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
M. Lettau, A. Sauer, S. Heiland, S. Rohde, M. Bendszus, and S. Hahnel
Carotid Artery Stents: In Vitro Comparison of Different Stent Designs and Sizes Using CT Angiography and Contrast-Enhanced MR Angiography at 1.5T and 3T
AJNR Am. J. Neuroradiol., November 1, 2009; 30(10): 1993 - 1997.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. W. Huegli, M. Aschwanden, G. Bongartz, K. Jaeger, H.-G. Heidecker, C. Thalhammer, A.-C. Schulte, C. Hashagen, A. L. Jacob, and D. Bilecen
Intraarterial MR Angiography and DSA in Patients with Peripheral Arterial Occlusive Disease: Prospective Comparison
Radiology, June 1, 2006; 239(3): 901 - 908.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. J. Martin, D. A. Saloner, T. P. L. Roberts, H. Roberts, O. M. Weber, W. Dillon, S. Cullen, V. Halbach, C. F. Dowd, and R. T. Higashida
Carotid Stent Delivery in an XMR Suite: Immediate Assessment of the Physiologic Impact of Extracranial Revascularization
AJNR Am. J. Neuroradiol., March 1, 2005; 26(3): 531 - 537.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Spuentrup, A. Ruebben, A. Mahnken, M. Stuber, C. Kolker, T. H. Nguyen, R. W. Gunther, and A. Buecker
Artifact-Free Coronary Magnetic Resonance Angiography and Coronary Vessel Wall Imaging in the Presence of a New, Metallic, Coronary Magnetic Resonance Imaging Stent
Circulation, March 1, 2005; 111(8): 1019 - 1026.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. D. Hagspiel, D. A. Leung, K. R. Nandalur, J. F. Angle, H. S. Dulai, D. J. Spinosa, A. H. Matsumoto, J. M. Christopher, H. Ahmed, and S. S. Berr
Contrast-Enhanced MR Angiography at 1.5 T After Implantation of Platinum Stents: In Vitro and In Vivo Comparison with Conventional Stent Designs
Am. J. Roentgenol., January 1, 2005; 184(1): 288 - 294.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S K Prasad and D J Pennell
Safety of cardiovascular magnetic resonance in patients with cardiovascular implants and devices
Heart, November 1, 2004; 90(11): 1241 - 1244.
[Full Text] [PDF]


Home page
CirculationHome page
R. M. Botnar, A. Buecker, A. J. Wiethoff, E. C. Parsons Jr, M. Katoh, G. Katsimaglis, R. M. Weisskoff, R. B. Lauffer, P. B. Graham, R. W. Gunther, et al.
In Vivo Magnetic Resonance Imaging of Coronary Thrombosis Using a Fibrin-Binding Molecular Magnetic Resonance Contrast Agent
Circulation, September 14, 2004; 110(11): 1463 - 1466.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. K. Wacker, R. M. Maes, J. A. Jesberger, S. G. Nour, J. L. Duerk, and J. S. Lewin
MR Imaging-Guided Vascular Procedures Using CO2 as a Contrast Agent
Am. J. Roentgenol., August 1, 2003; 181(2): 485 - 489.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Spuentrup, A. Ruebben, M. Stuber, R. W. Gunther, and A. Buecker
Metallic Renal Artery MR Imaging Stent: Artifact-free Lumen Visualization with Projection and Standard Renal MR Angiography
Radiology, June 1, 2003; 227(3): 897 - 902.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Buecker, E. Spuentrup, R. Grabitz, F. Freudenthal, E. G. Muehler, T. Schaeffter, J. J. van Vaals, and R. W. Gunther
Magnetic Resonance-Guided Placement of Atrial Septal Closure Device in Animal Model of Patent Foramen Ovale
Circulation, July 23, 2002; 106(4): 511 - 515.
[Abstract] [Full Text] [PDF]