Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Published Online
on March 11, 2002

Circulation. 2002
Published online before print March 11, 2002, doi: 10.1161/01.CIR.0000012349.14270.54
A more recent version of this article appeared on March 26, 2002
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
105/12/1472    most recent
01.CIR.0000012349.14270.54v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Xu, W.
Right arrow Articles by Lau, C.-P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Xu, W.
Right arrow Articles by Lau, C.-P.
Related Collections
Right arrow Electrophysiology
Right arrow Ablation/ICD/surgery

Submitted on October 17, 2001
Revised on January 9, 2002
Accepted on January 10, 2002

New Bayesian Discriminator for Detection of Atrial Tachyarrhythmias

Weichao Xu BE, MSEE, Hung-Fat Tse MD, Francis H.Y. Chan PhD, Peter Chin Wan Fung PhD*, Kathy Lai-Fun Lee MB, and Chu-Pak Lau MD

From the Department of Electrical and Electronic Engineering (W.X., F.H.Y.C.) and the Department of Medicine (H.-F.T., P.C.W.F., K.L.-F.L., C.-P.L.), Queen Mary Hospital, The University of Hong Kong.

Background—Accurate, rapid detection of atrial tachyarrhythmias has important implications in the use of implantable devices for treatment of cardiac arrhythmia. Currently available detection algorithms for atrial tachyarrhythmias, which use the single-index method, have limited sensitivity and specificity.

Methods and Results—In this study, we evaluated the performance of a new Bayesian discriminator algorithm in the detection of atrial fibrillation (AF), atrial flutter (AFL), and sinus rhythm (SR). Bipolar recording of 364 rhythms (AF=156, AFL=88, SR=120) at the high right atrium were collected from 20 patients who underwent electrophysiological procedures. After initial signal processing, a column vector of 5 features for each rhythm were established, based on the regularity, rate, energy distribution, percent time of quiet interval, and baseline reaching of the rectified autocorrelation coefficient functions. Rhythm identification was obtained by use of Bayes decision rule and assumption of Gaussian distribution. For the new Bayesian discriminator, the overall sensitivity for detection of SR, AF, and AFL was 97%, 97%, and 94%, respectively; and the overall specificity for detection of SR, AF, and AFL was 98%, 98%, and 99%, respectively. The overall accuracy of detection of SR, AF, and AFL was 98%, 97% and 98%, respectively. Furthermore, sensitivity, specificity, and accuracy of this algorithm were not affected by a range of white Gaussian noises with different intensities.

Conclusions—This new Bayesian discriminator algorithm, based on Bayes decision of multiple features of atrial electrograms, allows rapid on-line and accurate (98%) detection of AF with robust anti-noise performance.


Key words: tachyarrhythmias • intervals • fibrillation • pacemakers • atrium