Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1999;99:406-410

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Krahn, A. D.
Right arrow Articles by Norris, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Krahn, A. D.
Right arrow Articles by Norris, C.
Related Collections
Right arrow Arrhythmias, clinical electrophysiology, drugs
Right arrow Other diagnostic testing

(Circulation. 1999;99:406-410.)
© 1999 American Heart Association, Inc.


Clinical Investigation and Reports

Use of an Extended Monitoring Strategy in Patients With Problematic Syncope

Andrew D. Krahn, MD; George J. Klein, MD; Raymond Yee, MD; Teri Takle-Newhouse, MSc; Caro Norris; for the Reveal Investigators1

From the Division of Cardiology, University of Western Ontario, London, Ontario, Canada, and Medtronic, Minneapolis, Minn (T.T.-N.).


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Background—The conventional investigation of patients who present with syncope involves short-term ECG monitoring or provocative testing with head-up tilt and electrophysiological testing. A symptom-rhythm correlation is often difficult to obtain during spontaneous syncope because of its sporadic, infrequent, and unpredictable nature.

Methods and Results—We used a prolonged monitoring strategy to determine the cause of syncope in 85 patients (age, 59±18 years; 44 men) with recurrent undiagnosed syncope with an implantable loop recorder capable of cardiac monitoring for up to 18 months. During a mean of 10.5±4.0 months of follow-up, symptoms recurred in 58 patients (68%) 71±79 days (2.3±2.6 months) after implantable loop recorder insertion. An arrhythmia was detected in 42% of patients who recorded a rhythm during recurrent symptoms, with bradycardia present in 18 and tachycardia in 3. Five of the 18 bradycardic patients and 2 additional sinus rhythm patients received a clinical diagnosis of neurally mediated syncope. Patients who experienced presyncope were much less likely to record an arrhythmia during symptoms compared with recurrence of syncope (24% versus 70%, P=0.0005). There were no adverse events associated with recurrent symptoms, and there were no sudden deaths. Inability to freeze after an event occurred in 8 patients, and pocket infection occurred in 3.

Conclusions—The strategy of prolonged monitoring is effective and safe in patients with problematic syncope.


Key Words: syncope • arrhythmia • diagnosis


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Current investigation of patients who present with syncope involves short-term ECG monitoring or provocative testing with head-up tilt and electrophysiological testing.1 2 3 4 The diagnostic yield of Holter monitoring in syncope is disappointing,5 6 7 and provocative test results may be negative or difficult to interpret.8 9 A prolonged monitoring strategy has previously been difficult to use because of waning patient compliance and motivation with external loop recorder technology and the relatively short memory capabilities of these devices.7 10 11 12 Prolonged monitoring is also reliant on the spontaneous recurrence of symptoms, with attendant risk of injury, concern regarding life-threatening arrhythmias, and ongoing diagnostic uncertainty.

A symptom-rhythm correlation is often difficult to obtain during spontaneous episodes because of the sporadic, infrequent, and unpredictable nature of syncope. Despite a wide array of diagnostic tools, the cause of syncope is not determined after initial investigations in 38% to 47% of patients.6 13 14 Even after referral for tilt-table and electrophysiological testing, 10% to 26% of patients will remain undiagnosed.2 15 16

Recent advances in loop recorder technology have permitted a longer duration of external ECG monitoring than conventional Holter monitoring, improving the overall diagnostic yield.7 10 11 12 We used a new insertable loop recorder (ILR) that can provide monitoring for 14 months to assess the utility and safety of a prolonged monitoring strategy in a multicenter study of 85 syncopal patients without a diagnosis after initial assessment.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Patient Population
Patients with undiagnosed syncope after initial assessment that included a history, physical examination, ECG, and at least 24 hours of ambulatory or in-hospital monitoring were approached to participate in a study using an ILR (Reveal ILR, Medtronic USA Inc) to determine the cardiac rhythm during spontaneous syncope. Patients were eligible for the study if they had had 2 syncopal episodes within the previous 12 months or a single episode with a history of presyncope as well. Patients were excluded if they were unlikely to survive 1 year, were unable to give informed consent, had a previously implanted programmable medical device, were pregnant, or were women of childbearing potential not on a reliable form of contraception. Eighty-five patients with unexplained syncope underwent insertion of the ILR (Table 1Down). The mean number of syncopal episodes in the previous 12 months was 5.1±5.5 (median, 3). The majority of patients had suffered from recurrent syncope for >2 years. The study was approved by the institutional review board or medical ethics committee at each study center.


View this table:
[in this window]
[in a new window]
 
Table 1. Clinical Characteristics of the 85 Patients

Previous Investigations
Testing before patient enrollment in the study was performed at the discretion of the investigator (Table 1Up). All patients underwent clinical assessment, including ambulatory or in-hospital monitoring. Of the 85 patients, 21 had been referred to an internist and 73 had been referred to another cardiologist before assessment by the study investigator. Most patients had several investigations for syncope before ILR insertion, the most common of which were echocardiography, head-up tilt testing, and electrophysiological testing. One patient had experienced a previous cardiac arrest and underwent extensive investigation, including electrophysiological testing, before enrollment in the study.

Device
The ILR is a 61x19x8-mm recording device with 2 sensing bipoles 37 mm apart within its shell. It weighs 17 g and has a volume of 8 cm3, slightly smaller than a standard VVI pacemaker. The recorded ECG signal is stored in a circular buffer capable of retaining 21 minutes of uncompressed signal or 42 minutes of compressed signal in 1 or 3 divided parts. The memory buffer is frozen with a hand-held activator provided to the patient at the time of device implantation. The resultant programming can store a single episode of 21 minutes (20 minutes before and 1 minute after "freeze"), a 42-minute compressed episode (40 minutes before, 2 minutes after), three 7-minute episodes (6 minutes before, 1 minute after), or three 14-minute compressed episodes (12 minutes before, 2 minutes after). The episodes are then downloaded after interrogation with a standard pacemaker programmer (Medtronic 9790C).

Investigators performed device implantation in an operating room, cardiac catheterization laboratory, electrophysiology laboratory, or specialized procedure room at their discretion. The site of the implant was generally in the left infraclavicular region but was determined in each circumstance by patient and physician preference. Use of prophylactic antibiotics was left to the discretion of the implanting physician. After the skin was infiltrated with local anesthesia, a 2-cm incision was made. A pocket was fashioned, and the device was inserted and anchored with a nonabsorbable suture. The skin was closed with absorbable sutures, and a satisfactory R-wave signal was verified with the programming head applied over the implanted device. The patient, along with a spouse, family member, or friend, was instructed in the use of the activator at the time of implantation. Patients were instructed to activate the device in the event of syncope or presyncope. Follow-up was performed after each event. The device remained implanted until syncope or presyncope recurred unless the patient or investigator chose to remove it sooner. Devices were removed after 18 months of follow-up or at end of battery life.

Analysis
Continuous variables were compared by Student's t tests, and categorical variables were compared by a {chi}2 test. A value of P<0.05 was considered significant.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Recurrent Symptoms
During a mean of 10.5±4.0 months of follow-up, symptoms recurred in 58 patients (68%) 71±79 days (2.3±2.6 months) after ILR insertion (median, 51 days, or 1.7 months). One patient had recurrence within a week of the implantation, and 3 patients had recurrence within the first month. Forty-nine of 85 patients (58%) had recurrence of symptoms within 6 months of implantation. Follow-up was >9 months in 68 of 85 patients. Failure to appropriately "freeze" after symptoms occurred 24 times in 14 patients. No instance was attributed to device failure. Six of these patients had an appropriate freeze after spontaneous symptoms on a different occasion. A total of 128 events were frozen by the remaining 50 patients during the course of follow-up. The remaining 27 patients have not had recurrence and continue to be followed up.

Symptom-Rhythm Correlation
An arrhythmia was detected in 21 of the 50 patients (42%) who recorded a rhythm during recurrent symptoms, with bradycardia being the most frequent (Figure 1Down). Of the 18 patients with bradycardia (heart rate <50 bpm), 12 underwent device removal and pacemaker implantation. Five of the 18 patients had heart rate slowing, which the investigator interpreted as the cardioinhibitory component of neurally mediated syncope. Two additional patients had relative slowing, with a heart rate >50 bpm, and also received a clinical diagnosis of neurally mediated syncope (Figure 2Down). Three patients had tachyarrhythmias associated with recurrent symptoms: sustained supraventricular tachycardia in 2 patients, who subsequently underwent catheter ablation, and atrial flutter with a rapid ventricular response in 1 patient, who received pharmacological therapy. The remaining 29 patients had sinus rhythm during symptomatic recurrence and continue to be followed up. Devices remained implanted in these patients to monitor subsequent episodes.



View larger version (18K):
[in this window]
[in a new window]
 
Figure 1. Recorded rhythm during recurrent symptoms. Symptom-rhythm correlation in the 58 patients who experienced recurrent syncope or presyncope.



View larger version (19K):
[in this window]
[in a new window]
 
Figure 2. Clinical diagnosis in 50 patients with symptom-rhythm correlation after recurrent events with the ILR.

Syncope Versus Presyncope
Of the 50 patients with a symptom-rhythm correlation, 13 had syncope, 10 had recurrence of syncope and presyncope, and 27 had presyncope alone. When patients experienced presyncope, they were much less likely to record an arrhythmia during symptoms compared with recurrence of syncope (24% versus 70%, P=0.0005, Figure 3Down). When those patients with a clinical diagnosis of neurally mediated syncope (n=4) or presyncope (n=4) were excluded, the difference remained significant (24% versus 63%, P=0.006). Arrhythmias were seen in 9 of the 13 patients (69%) who had recurrence of syncope alone (without other presyncopal events), with bradycardia recorded in all 9 patients during syncope. In the 10 patients with both syncope and presyncope, syncope was associated with an arrhythmia in 7 (bradycardia in 5, tachycardia in 2), whereas presyncope documented an arrhythmia in only 4 patients (bradycardia in 2, tachycardia in 2). The 3 patients with an arrhythmia during presyncope had the same arrhythmia during syncope.



View larger version (30K):
[in this window]
[in a new window]
 
Figure 3. Diagnosis by recurrent symptom. Cause of symptoms in patients with syncope versus presyncope. Syncope was much more likely to correlate with an arrhythmia (P=0.0005). See text for discussion.

Device
The majority of devices were implanted outside of an operating room setting (Table 2Down). The device was inserted in the left pectoral region near a traditional pacemaker implant site in 64% of patients. Of the remaining 31 devices, 27 were implanted in the left inframammary region. The mean implant voltage was 481±279 µV for all 85 patients. An adequate electrogram was obtained in all 85 patients (range, 58 to 1300 µV). The signal-to-noise ratio was 19:1. P waves were seen in 37% of vertical implants, compared with 14% of horizontal ones. The sensed amplitude was 831±343 µV at the single center at which systematic surface mapping was performed before implantation to optimize the sensed signal amplitude.


View this table:
[in this window]
[in a new window]
 
Table 2. Implant Data on 85 Patients Who Received an ILR

Two patients who did not receive prophylactic antibiotics developed local infection requiring treatment with oral antibiotics after device removal. A second device was reimplanted in another site in 1 of these patients. A third patient had persistent pain at a left inframammary implant site, which resolved when the device was moved to the left pectoral region. A fourth patient developed local erosion with infection 13 weeks after implantation. The device was explanted without incident. No patient requested removal of the device before recurrence of symptoms. The devices were removed at the end of follow-up without complications.

Outcome
During the study, 1 patient died of myocardial infarction that was not complicated by arrhythmias. A second patient died of cancer of the lung, and a third patient suffered a cerebrovascular accident and withdrew from the study.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowAppendix 1
down arrowReferences
 
The cause of syncope can be difficult to determine if it is not obvious after initial assessment.6 13 14 Despite the good prognosis of patients whose investigations are negative, syncope may recur, with attendant morbidity and even mortality.2 8 17 18 19 20 21 The current approach to the syncopal patient involves a mixture of passive monitoring, which samples a relatively small time frame, and provocative testing aimed at actively reproducing the clinical situation. Both tilt-table and electrophysiological testing are negative in as many as 70% of cases8 9 and represent an artificial environment, making interpretation of results particularly difficult. The reference standard for establishing a diagnosis is the recording of physiological parameters during a clinical episode. This obviates the interpretation difficulties of extrapolating the results of provocative testing to the clinical situation.

In a previous pilot study of 24 patients with syncope, a prototype implantable loop recorder established the cardiac rhythm in all 21 patients who had recurrent syncope after the device was implanted.15 This population represented a difficult subgroup with refractory but infrequent syncope that was not diagnosed after extensive testing. The present study examined the utility of the ILR in a multicenter study. The patient population was selected to be more representative of those referred to cardiologists or electrophysiologists for investigation of syncope after a workup that varied according to physician preference.

The strategy of prolonged monitoring was successful in establishing a symptom-rhythm correlation in 86% of the 58 patients who had recurrence during the follow-up period. The rhythm profile of patients during recurrent syncope reflected an arrhythmic cause in 42% of patients, in keeping with the findings of the pilot study (48%). In the remaining patients, an arrhythmia was eliminated as a potential cause of symptoms, alleviating concerns of a life-threatening arrhythmia.

The absence of sudden death or significant morbidity suggests that this observational approach was safe in the population studied and did not place patients at risk during spontaneous recurrence. This is of particular interest given the prevalence of significant structural heart disease, the major determinant of prognosis in syncopal patients.3 Sixty-two percent of patients had some structural heart disease, with 19% having documented coronary artery disease, previous cardiac arrest, or left ventricular dysfunction. Investigator selection and preceding negative investigations, including electrophysiological testing in some patients, may have screened out those patients at higher risk of life-threatening arrhythmias. This does not necessarily imply that a monitoring strategy is safe in all patients. For example, patients with poor left ventricular function and inducible ventricular tachycardia at electrophysiological testing have been shown to receive appropriate shocks when managed with an implantable defibrillator.22 A proactive approach using electrophysiological testing in this population seems reasonable.

Symptoms did not recur in 32% of patients over 10 months of follow-up. This spontaneous resolution is in keeping with other series, which have noted a 57% to 85% resolution during 10 to 40 months of follow-up after negative initial investigations.1 2 21 23 24 This finding may relate to the spontaneous periodicity of syncope, a self-limited cause, or a screening effect of the completed investigations, which have identified the causes of syncope that are most likely to recur.

The occurrence of presyncope is often clinically interpreted as "imminent" syncope. It is tempting to use presyncope as a surrogate for syncope. The predictive value of presyncope in establishing an arrhythmic cause for symptoms was low. Excluding patients with a diagnosis of neurally mediated syncope, only 24% of patients with presyncope were found to have an arrhythmia (versus 63% for syncope). The majority of patients (76%) reporting presyncope were in sinus rhythm. In those patients with both presyncope and syncope, presyncope was misleading in 3 of the 6 patients with sinus rhythm during presyncope who subsequently had an arrhythmia documented in conjunction with frank syncope. Others have similarly reported a low yield for external monitoring in patients with presyncope,25 although data on the relationship between presyncope and syncope in the same patients remain scant.

Individual investigators each implanted 1 to 4 devices, with the exception of a single site, at which 11 devices were implanted. Despite the absence of a learning period with respect to implantation technique, the relatively low complication rate suggests that the procedure is readily adopted by operators experienced with implantable devices. The unexpected infection rate may reflect the need for routine antibiotic prophylaxis, which was not required in the study. Programming and interrogation were performed with a pacemaker programmer, which is accessible to most pacing centers. Patient-related difficulties with freezing after events occurred in 16% of patients. Of these patients, {approx}50% subsequently froze appropriately. This problem may be minimized in the future by development of autodetection functions, improved patient education, and expanded memory capacity. Similar difficulties with freezing have been reported in 32% of patients using an external loop recorder,7 10 in whom device malfunction, patient noncompliance, or inability to activate the recorder was responsible for the lack of success. External devices suffer from insufficient memory for many patients who are unable to activate the device within 4 to 6 minutes of syncope, as well as waning patient compliance with external electrodes in the absence of a diagnosis.

Limitations
The population under study represents a spectrum of individuals referred to a cardiologist or electrophysiologist for evaluation. Although they may not represent a primary syncope population, they served to test the utility of a prolonged monitoring strategy in patients with recurrent syncope. Second, obtaining a symptom-rhythm correlation does not necessarily lead to a diagnosis. Nonetheless, exclusion of arrhythmia often alleviates the concerns of both the patient and physician regarding the potential for life-threatening arrhythmias and allows the focus of further investigations (if necessary) to shift to other areas. Finally, a small proportion of patients were unable to activate the device after a spontaneous event. Future iterations should include programmable automatic detection algorithms and longer memory loops. In addition, monitoring of other physiological parameters, such as blood pressure and oxygen saturation, is a feasible goal. Current development suggests that device size may decrease by 30% to 60%, facilitating implantation in an office setting by operators with less surgical experience.

Conclusions
The strategy of prolonged monitoring is effective in establishing a symptom-rhythm correlation in the majority of patients with problematic syncope. It obviates the need for difficult interpretation of provocative testing. Presyncope is much less likely to be associated with an arrhythmia than syncope and did not prove to be an accurate surrogate for syncope in establishing a diagnosis.


*    Acknowledgments
 
This study was supported in part by the Heart and Stroke Foundation of Ontario.


*    Footnotes
 
Reprint requests to Andrew Krahn, London Health Sciences Center, University Campus, 339 Windermere Rd, London, Ontario, Canada N6A 5A5.

1 See Appendix for list of investigators. Back


*    Appendix 1
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*Appendix 1
down arrowReferences
 
Investigators
Dr D. Cameron, Toronto Hospital; Dr C. LeFeuvre, Hamilton General Hospital; Dr H. Abdollah, Hotel Dieu Hospital; Dr R. Leather, Royal Jubilee Hospital; Dr G. Klein and Dr A. Krahn, London Health Sciences Center; Dr C. Kerr, St Paul's Hospital; Dr A. Gillis, University of Calgary; Dr L. Sterns, Queen Elizabeth II Hospital; Dr M. Sami, Royal Victoria Hospital; Dr M. Talajic, Montreal Heart Institute; Dr F. Philippon, Hôpital Laval; Dr M. O'Reilly, Valley Regional Hospital; Dr A. Tang, University of Ottawa Heart Institute; Dr R. Wald, Mt Sinai Hospital; Dr H. Schmidinger, Allgemeines Krankenhuis Wien; Prof R. Stroobandt, Sint Jozef Ziekenhuis Oostenende; Prof P. Brugada, Onze Lieve Vrouwe Ziekenhuis Aalst; Dr E. Simonsen, Odense Universitets Hospital; Prof S. Kacet, Hôpital Cardiologique Universitaire de Lille; Dr T. Lavergne, Hôpital Broussais; Prof P. Coumel, Hôpital Lariboisière; Prof P. Touboul, Hôpital Louis Pradel; Prof P. Vardas, Heraklion University Hospital; Dr J. Balkin, Shaare Zedek Hospital; Dr E. Ovsyshcher, Soroka Medical Center; Dr A. Marchini, Specedali Civili di Brescia; Dr C. D'Agostino, Ospedale Policlinico; Dr C. Menozzi, Arcispedale Sante Maria Nuova; Dr F. Bracke, Catharina Ziekenhuis; Dr R. van Mechelen, Sint Franciscus Gasthuis; Dr R. van der Heijden, Holy Ziekenhuis; Dr W. Beukema, Ziekenhuis de Weezenlanden; Dr A. Ramdat Misier, St Sophia Ziekenhuis; Dr I. Obel, Milpark Hospital; Dr F. Dateling, Johannesburg Hospital; Dr J. Fuhrer, Inselspital; Prof A.J. Camm, St Georges Hospital.

Received April 21, 1998; revision received September 17, 1998; accepted October 9, 1998.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
up arrowAppendix 1
*References
 

  1. Kapoor WN, Hammill SC, Gersh BJ. Diagnosis and natural history of syncope and the role of electrophysiologic testing. Am J Cardiol. 1989;63:730–734.[Medline] [Order article via Infotrieve]
  2. Sra JS, Anderson AJ, Sheikh SH, Avitall B, Tchou PT, Troup PJ, Gilbert CJ, Akhtar M, Jazayeri MR. Unexplained syncope evaluated by electrophysiologic studies and head-up tilt testing. Ann Intern Med. 1991;114:1013–1019.
  3. Kapoor WN, Karpf M, Weiand S, Peterson JR, Levey GS. A prospective evaluation and follow-up of patients with syncope. N Engl J Med. 1983;309:197–204.[Abstract]
  4. Manolis AS, Linzer M, Salem D, Estes NAM. Syncope: current diagnostic evaluation and management. Ann Intern Med. 1990;112:850–863.
  5. Kapoor WN. Evaluation and management of the patient with syncope. JAMA. 1992;268:2553–2560.[Abstract]
  6. Kapoor WN. Evaluation and outcome of patients with syncope. Medicine. 1990;69:160–175.[Medline] [Order article via Infotrieve]
  7. Linzer M, Pritchett ELC, Pontinen M, McCarthy E, Divine GW. Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope. Am J Cardiol. 1990;66:214–219.[Medline] [Order article via Infotrieve]
  8. Klein GJ, Gersh BJ, Yee R. Electrophysiologic testing: the final court of appeal for diagnosis of syncope? Circulation. 1995;92:1332–1335.[Free Full Text]
  9. Kapoor WN, Smith NA, Miller NL. Upright tilt testing in evaluating syncope: a comprehensive literature review. Am J Med. 1994;97:78–88.[Medline] [Order article via Infotrieve]
  10. Cumbee SR, Pryor RE, Linzer M. Cardiac loop recording: a new non-invasive diagnostic test in recurrent syncope. Southern Med J. 1990;83:39–43.[Medline] [Order article via Infotrieve]
  11. Brown AP, Dawkins KD, Davies JG. Detection of arrhythmias: use of a patient-activated ambulatory electrocardiogram device with a solid state memory loop. Br Heart J. 1987;58:251–253.[Abstract/Free Full Text]
  12. Fogel RI, Evans JJ, Prystowsky EN. Utility and cost of event recorders in the diagnosis of palpitations, presyncope and syncope. Am J Cardiol. 1997;79:207–208.[Medline] [Order article via Infotrieve]
  13. Martin GJ, Adams SL, Martin HG, Matthews J, Zull D, Scanlon PJ. Prospective evaluation of syncope. Ann Emerg Med. 1984;13:499–504.[Medline] [Order article via Infotrieve]
  14. Day SC, Cook EF, Funkenstein H, Goldman L. Evaluation and outcome of emergency room patients with transient loss of consciousness. Am J Med. 1982;73:15–23.[Medline] [Order article via Infotrieve]
  15. Krahn AD, Klein GJ, Norris C, Yee R. The etiology of syncope in patients with negative tilt table and electrophysiological testing. Circulation. 1995;92:1819–1824.[Abstract/Free Full Text]
  16. Krahn AD, Klein GJ, Yee R, Norris C. The etiology of syncope in patients with negative non-invasive and invasive testing: final results from a pilot study with an implantable loop recorder. Am J Cardiol. 1998;82:117–119.[Medline] [Order article via Infotrieve]
  17. Morady F, Shen E, Schwartz A, Hess D, Bhandari A, Sung RJ, Scheinman MM. Long term follow-up of patients with recurrent unexplained syncope evaluated by electrophysiologic testing. J Am Coll Cardiol. 1983;2:1053–1059.[Abstract]
  18. Gulamhusein S, Naccarelli GV, Ko PT, Prystowsky EN, Zipes DP, Barnett HJM, Heiger JJ, Klein GJ. Value and limitations of clinical electrophysiologic study in assessment of patients with unexplained syncope. Am J Med. 1982;73:700–705.[Medline] [Order article via Infotrieve]
  19. Doherty JU, Pembrook-Rogers D, Grogan EW, Falcone RA, Buxton AE, Marchlinski FE, Cassidy DM, Kienzle MG, Almendral JM, Josephson ME. Electrophysiologic evaluation and follow-up characteristics of patients with recurrent unexplained syncope and presyncope. Am J Cardiol. 1985;55:703–708.[Medline] [Order article via Infotrieve]
  20. Olshansky B, Mazuz M, Martins JB. Significance of inducible tachycardia in patients with syncope of unknown origin: a long term follow-up. J Am Coll Cardiol. 1985;5:216–223.[Abstract]
  21. Muller T, Roy D, Talajic M, Lemery R, Nattel S, Cassidy D. Electrophysiologic evaluation and outcome of patients with syncope of unknown origin. Eur Heart J. 1991;12:139–143.[Abstract/Free Full Text]
  22. Link MS, Costeas XF, Griffith JL, Colburn CD, Estes NAM, Wang PJ. High incidence of appropriate implantable-defibrillator therapy in patients with syncope of unknown etiology and inducible ventricular arrhythmias. J Am Coll Cardiol. 1997;29:370–375.[Abstract]
  23. Freed LA, Eagle KA, Mahjoub ZA, Gold MR, Smith AJC, Terrell LB, O'Gara PT, Paul SD. Gender difference in presentation, management, and cardiac event-free survival in patients with syncope. Am J Cardiol. 1997;80:1183–1187.[Medline] [Order article via Infotrieve]
  24. Bass EB, Elson JJ, Fogoros RN, Peterson J, Arena VC, Kapoor WN. Long-term prognosis of patients undergoing electrophysiologic studies for syncope of unknown origin. Am J Cardiol. 1988;62:1186–1191.[Medline] [Order article via Infotrieve]
  25. Zimetbaum P, Kim KY, Ho KKH, Zebede J, Josephson ME, Goldberger AL. Utility of patient-activated cardiac event recorders in general clinical practice. Am J Cardiol. 1997;79:371–372.[Medline] [Order article via Infotrieve]



This article has been cited by other articles:


Home page
HeartHome page
R. H Pass and L. Liberman
The implantable loop recorder in children: searching for indications
Heart, July 1, 2008; 94(7): 832 - 833.
[Full Text] [PDF]


Home page
HeartHome page
B Yeung and K McLeod
The implantable loop recorder in children
Heart, July 1, 2008; 94(7): 888 - 891.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
B. Pierre, L. Fauchier, G. Breard, O. Marie, P. Poret, and D. Babuty
Implantable loop recorder for recurrent syncope: influence of cardiac conduction abnormalities showing up on resting electrocardiogram and of underlying cardiac disease on follow-up developments
Europace, April 1, 2008; 10(4): 477 - 481.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J.-E. Claesson, B.-E. Kristensson, N. Edvardsson, and P. Wahrborg
Less syncope and milder symptoms in patients treated with pacing for induced cardioinhibitory carotid sinus syndrome: a randomized study
Europace, October 1, 2007; 9(10): 932 - 936.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
R. Maggi, C. Menozzi, M. Brignole, C. Podoleanu, M. Iori, R. Sutton, A. Moya, F. Giada, S. Orazi, and N. Grovale
Cardioinhibitory carotid sinus hypersensitivity predicts an asystolic mechanism of spontaneous neurally mediated syncope
Europace, August 1, 2007; 9(8): 563 - 567.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
Developed in Collaboration With the European Heart, D. P. Zipes, A. J. Camm, M. Borggrefe, A. E. Buxton, B. Chaitman, M. Fromer, G. Gregoratos, G. Klein, A. J. Moss, et al.
ACC/AHA/ESC 2006 Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: A Report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death)
J. Am. Coll. Cardiol., September 5, 2006; 48(5): e247 - e346.
[Full Text] [PDF]


Home page
EuropaceHome page
Writing Committee Members, D. P. Zipes, A. J. Camm, M. Borggrefe, A. E. Buxton, B. Chaitman, M. Fromer, G. Gregoratos, G. Klein, A. J. Moss, et al.
ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society
Europace, September 1, 2006; 8(9): 746 - 837.
[Full Text] [PDF]


Home page
EuropaceHome page
F. Enseleit and F. Duru
Long-term continuous external electrocardiographic recording: a review.
Europace, April 1, 2006; 8(4): 255 - 266.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J.-C. Deharo, C. Jego, A. Lanteaume, and P. Djiane
An Implantable Loop Recorder Study of Highly Symptomatic Vasovagal Patients: The Heart Rhythm Observed During a Spontaneous Syncope Is Identical to the Recurrent Syncope But Not Correlated With the Head-Up Tilt Test or Adenosine Triphosphate Test
J. Am. Coll. Cardiol., February 7, 2006; 47(3): 587 - 593.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. J. Farwell, N. Freemantle, and N. Sulke
The clinical impact of implantable loop recorders in patients with syncope
Eur. Heart J., February 1, 2006; 27(3): 351 - 356.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. Sreeram, F. Hitchcock, and G. Bennink
Abdominal Implantation of Loop Recorders in Infants and Children
Ann. Thorac. Surg., February 1, 2005; 79(2): 726 - 727.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D.J. Farwell, N. Freemantle, and A.N. Sulke
Use of implantable loop recorders in the diagnosis and management of syncope
Eur. Heart J., July 2, 2004; 25(14): 1257 - 1263.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
E. N Simantirakis, S. I Schiza, M. E Marketou, S. I Chrysostomakis, G. I Chlouverakis, N. C Klapsinos, N. S Siafakas, and P. E Vardas
Severe bradyarrhythmias in patients with sleep apnoea: the effect of continuous positive airway pressure treatment: A long-term evaluation using an insertable loop recorder
Eur. Heart J., June 2, 2004; 25(12): 1070 - 1076.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
L. Boersma, L.ís Mont, A. Sionis, E. García, and J. Brugada
Value of the implantable loop recorder for the management of patients with unexplained syncope
Europace, January 1, 2004; 6(1): 70 - 76.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. D. Krahn, G. J. Klein, R. Yee, J. S. Hoch, and A. C. Skanes
Cost implications of testing strategy in patients with syncope: Randomized assessment of syncope trial
J. Am. Coll. Cardiol., August 6, 2003; 42(3): 495 - 501.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. C. Kurer
Implantable looprecorders: dollars and sense
J. Am. Coll. Cardiol., August 6, 2003; 42(3): 502 - 504.
[Full Text] [PDF]


Home page
HeartHome page
J R Gimbel
Novel use of an "insertable" loop recorder
Heart, June 1, 2003; 89(6): e18 - 18.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
W. N. Kapoor
Is There an Effective Treatment for Neurally Mediated Syncope?
JAMA, May 7, 2003; 289(17): 2272 - 2275.
[Full Text] [PDF]


Home page
EuropaceHome page
S. I. Chrysostomakis, N. C. Klapsinos, E. N. Simantirakis, M. E. Marketou, D. C. Kambouraki, and P. E. Vardas
Sensing issues related to the clinical use of implantable loop recorders
Europace, January 1, 2003; 5(2): 143 - 148.
[Abstract] [PDF]


Home page
NEJMHome page
W. H. Maisel and W. G. Stevenson
Syncope -- Getting to the Heart of the Matter
N. Engl. J. Med., September 19, 2002; 347(12): 931 - 933.
[Full Text] [PDF]


Home page
CirculationHome page
C. Menozzi, M. Brignole, R. Garcia-Civera, A. Moya, G. Botto, L. Tercedor, R. Migliorini, X. Navarro, and on behalf of the International Study on Syncope of
Mechanism of Syncope in Patients With Heart Disease and Negative Electrophysiologic Test
Circulation, June 11, 2002; 105(23): 2741 - 2745.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
S. I. Chrysostomakis, E. N. Simantirakis, M. E. Marketou, and P. E. Vardas
Implantable loop recorder undersensing mimicking complete heart block
Europace, January 1, 2002; 4(2): 211 - 213.
[Abstract] [PDF]


Home page
CirculationHome page
A. Moya, M. Brignole, C. Menozzi, R. Garcia-Civera, S. Tognarini, L. Mont, G. Botto, F. Giada, and D. Cornacchia
Mechanism of Syncope in Patients With Isolated Syncope and in Patients With Tilt-Positive Syncope
Circulation, September 11, 2001; 104(11): 1261 - 1267.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
L. A. Pires, J. R. Ganji, R. Jarandila, and R. Steele
Diagnostic Patterns and Temporal Trends in the Evaluation of Adult Patients Hospitalized With Syncope
Arch Intern Med, August 13, 2001; 161(15): 1889 - 1895.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S.G. Priori, E. Aliot, C. Blomstrom-Lundqvist, L. Bossaert, G. Breithardt, P. Brugada, A.J. Camm, R. Cappato, S.M. Cobbe, C. Di Mario, et al.
Task Force on Sudden Cardiac Death of the European Society of Cardiology
Eur. Heart J., August 2, 2001; 22(16): 1374 - 1450.
[PDF]


Home page
CirculationHome page
A. D. Krahn, G. J. Klein, R. Yee, and A. C. Skanes
Randomized Assessment of Syncope Trial : Conventional Diagnostic Testing Versus a Prolonged Monitoring Strategy
Circulation, July 3, 2001; 104(1): 46 - 51.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M. BRIGNOLE, C. MENOZZI, A. MOYA, and R. GARCIA-CIVERA
Implantable loop recorder: towards a gold standard for the diagnosis of syncope?
Heart, June 1, 2001; 85(6): 610 - 612.
[Full Text]


Home page
Postgrad. Med. J.Home page
W Arthur and G C Kaye
Current investigations used to assess syncope
Postgrad. Med. J., January 1, 2001; 77(903): 20 - 23.
[Full Text]


Home page
NEJMHome page
W. N. Kapoor
Syncope
N. Engl. J. Med., December 21, 2000; 343(25): 1856 - 1862.
[Full Text]