(Circulation. 1998;98:2235-2240.)
© 1998 American Heart Association, Inc.
Clinical Investigation and Reports |
From Cardiology (M.F., U.K., B.M.), Cardiovascular Research (R.R.W., G.N.) and Hypertension Division (S.S.), University Hospital, Bern; Cardiology (G.N., T.F.L.), University Hospital Zürich; and F. HoffmannLa Roche, Basel (R.S., C.R.J., M.C.), Switzerland.
Correspondence to Thomas F. Lüscher, MD, FESC, Professor and Head of Cardiology, University Hospital, CH-8091 Zürich, Switzerland.
| Abstract |
|---|
|
|
|---|
Methods and ResultsIn a double-blind, placebo-controlled randomized study, we investigated the effects of the ETA/ETB endothelin-receptor antagonist bosentan or placebo on systemic and coronary hemodynamics in 28 patients with angiographically documented stable coronary artery disease by quantitative coronary angiography and an intracoronary Doppler guidewire. Bosentan 200 mg IV decreased systolic blood pressure (P<0.05), whereas heart rate increased slightly (P<0.05). Coronary diameter increased, particularly in vessels with no or mild angiographic changes (P<0.01). Glycerol trinitrate did not further dilate these segments, whereas coronary diameter increased significantly after nitrate in the placebo group. The increase in coronary diameter after bosentan correlated inversely with plasma LDL-cholesterol levels (P<0.01) in both stenotic and angiographically normal coronary segments. Coronary flow velocity did not change. Bosentan was well tolerated.
ConclusionsEndogenous endothelin exerts a vasoconstrictor tone in epicardial coronary arteries of patients with coronary artery disease, as evidenced by the vasodilation exerted by the combined ETA/ETB endothelin-receptor antagonist bosentan under acute conditions. Bosentan can safely be given to these patients. Hence, further long-term studies are necessary to determine the therapeutic potential of endothelin-receptor antagonists in patients with coronary artery disease.
Key Words: endothelin bosentan blood flow coronary disease angiography
| Introduction |
|---|
|
|
|---|
Endothelin antagonists allow us to investigate the role of endogenous ET and may provide a new therapy for coronary artery disease. In vitro and in intact animals, ET antagonists are potent inhibitors of ET.5 14 In the human forearm circulation, the drugs inhibit ET-induced vasoconstriction and have mild vasodilator effects.15 16 In coronary artery disease, contractile ETB receptors on vascular smooth muscle cells are upregulated,17 18 19 suggesting that combined ETA/ETB-receptor antagonists might be suited for this condition. Bosentan, an ETA/ETB antagonist, has been studied in animals and patients with congestive heart failure20 ; it produced a marked vasodilation in both the peripheral and pulmonary circulation of these patients with very high plasma ET levels. The effects of an ET antagonist in patients with coronary artery disease are unknown. Because ET in these patients might contribute to myocardial ischemia and thus deteriorate myocardial oxygen supply, we investigated the effects of the ET antagonist bosentan on systemic and coronary hemodynamics in coronary artery disease.
| Methods |
|---|
|
|
|---|
|
Study Design
Calcium channel blockers, ACE inhibitors, nitrates,
diuretics, and other vasodilators were stopped at least 3 to 4
half-lives before the study. Coronary angiography was performed
by the femoral approach. If target vessel stenosis was 50%,
the patient was excluded. After completion of the
diagnostic catheterization, heparin 20 000
IU IV was given and a 6F guiding catheter (Pink Power,
Schneider-Pfizer) was introduced into the left or right
coronary artery. A Doppler guidewire (Flowire,
medium tip, Cardiometrics) was advanced into the stenotic
artery and the tip placed beyond the stenosis. Intra-aortal
blood pressure was monitored, and heart rate (ECG) was registered.
After a resting period (30 minutes), baseline measurements were performed. Then, bosentan 200 mg or placebo was infused over 15 minutes through a peripheral venous catheter. Forty minutes after the infusion was started, hemodynamic measurements were repeated and an angiogram was performed. To assess maximal coronary dilator capacity, quantitative angiography was repeated after injection of glycerol trinitrate 200 µg IC (Schwarz Pharma). Finally, coronary flow reserve was assessed by calculating the ratio of peak to baseline flow velocity after adenosine (right/left coronary artery, 12/18 µg IC).
Coronary Blood Flow Velocity
Blood flow velocity was assessed with a Doppler guidewire.
The wire was carefully positioned to obtain stable flow velocity
signals over the whole study period. Two patients (1 in the placebo
group, 1 in the bosentan group) had to be excluded from the study,
because the stability or quality of the signal was not satisfactory;
both patients simultaneously experienced angina pectoris,
indicating that the stenosis under investigation was too
narrow; thus, the Doppler wire led to a subtotal occlusion of the
vessel, leading to ischemia.
Quantitative Coronary Angiography
Angiography was performed with a fully digitized biplane
multidirectional isocentric radiological system (Diagnost C2, Philips).
Sequences were acquired at 12.5 frames per second. Angiograms were
analyzed with a digital edge-detection
system.21 Quantitative coronary
angiography was performed in both the stenotic vessel and a
nondiseased control vessel.
Derived Parameters
For estimating directional changes in coronary blood
flow, a coronary blood flow index was calculated by multiplying
the mean Doppler flow velocity with the cross-sectional area as
described.22 The area of the vessel was assessed
by quantitative coronary angiography beyond the
stenosis in the region of the tip of the Doppler wire, ie,
where flow velocity was measured. An index for coronary
vascular resistance was calculated from the ratio of the mean aortic
blood pressure divided by the coronary flow
index.22
Drugs
Bosentan23 or placebo (F. HoffmannLa
Roche) was prepared in a double-blind, randomized fashion by a trained
nurse not involved in the study. Glycerol trinitrate (Perlinganit,
Schwarz-Pharma) and adenosine (Krenosin, Sanofi Winthrop) were
injected as an intracoronary bolus. All investigators
performing the angiograms and their analysis were not aware of
the randomization code (double-blind, placebo-controlled study
design).
Hormone Plasma Levels
Plasma immunoreactivity for ET was measured by radioimmunoassay
as previously described.24 Plasma
catecholamines were determined by high-performance
liquid chromatography (Hypertension Laboratory,
University Hospital Bern, Switzerland).
Analysis and Statistics
Results are expressed as mean±SEM; significances of differences
were calculated by ANOVA or Student's t test as
appropriate; a value of P
0.05 was taken for statistical
significance. For blood pressure and heart rate, the area under the
time-response curve was calculated.
| Results |
|---|
|
|
|---|
|
Heart Rate
At baseline, heart rate was similar in the two groups (placebo,
63±2 bpm; bosentan, 65±2 bpm; P=NS). Heart rate tended to
increase slightly after bosentan, whereas it tended to decrease after
placebo (Figure 1
, right; P=NS versus baseline,
P<0.05 versus placebo) and increased further when
intracoronary glycerol trinitrate was injected on top of
bosentan (Figure 1
, right; P=0.05 versus control before
nitrate, P<0.05 versus placebo).
Coronary Hemodynamics
Epicardial Coronary Diameter
Baseline coronary diameters were similar in the two groups
in stenosed and control vessels (Table 2
). After bosentan, maximal
diameter increased in the control vessel (Table 2
, P<0.01
versus baseline) and tended to increase in the diseased vessel (Table 2
, P=NS versus baseline), whereas it did not change with
placebo (Table 2
). Within stenotic segments, there was no
difference between placebo and bosentan (P=NS). After
intracoronary nitrate, maximal diameter of diseased and control
vessels increased in the placebo group (Table 2
; P<0.05
versus control). In contrast, nitroglycerin did not
further increase coronary diameter in the bosentan group (Table 2
; P=NS versus control).
|
Changes in coronary diameter after bosentan, but not after
placebo, correlated inversely with LDL cholesterol plasma
levels in both the stenotic segment and the control vessel
(Figure 2
;
r2=0.52 to 0.56; P<0.01). No
such correlation was found with HDLs or triglycerides
(r2<0.1; P=NS). There was no
correlation of the changes in coronary blood flow or the
changes in plasma ET levels with LDL-cholesterol levels
(r2<0.1; P=NS).
|
Coronary Blood Flow
At baseline, both average and maximum flow velocities were similar
in the two groups (Table 2
; P=NS). Average and maximum flow
velocity did not change after bosentan or placebo (Table 2
;
P=NS). Coronary flow index tended to increase in the
bosentan group but not in the placebo group (P=NS).
Coronary resistance tended to increase in the placebo group,
whereas it did not change with bosentan (Table 2
; P=NS).
Coronary flow reserve (ratio of peak to baseline flow velocity
after IC adenosine) was impaired in all patients (placebo,
2.0±0.2; bosentan, 1.8±0.1) but not different in the placebo and
bosentan groups (P=NS).
Biochemical Parameters
Baseline plasma ET levels were similar in the two groups (placebo,
3.8±0.2 pg/mL; bosentan, 3.4±0.2 pg/mL; P=NS, Figure 3
). After bosentan, plasma ET increased
by 240% (P<0.0001 versus placebo, Figure 3
) but not with
placebo (P=NS). Plasma norepinephrine tended to
increase in the two groups (placebo, from 23±2 to 28±4 ng/dL,
P=NS; bosentan, from 21±2 to 27±4 ng/dL, P=NS),
whereas plasma epinephrine tended to decrease after bosentan
(placebo, from 5.0±0.5 to 5.3±0.7 ng/dL, P=NS; bosentan,
from 5.5±1.0 to 4.7±0.5 ng/dL). No significant changes in hemoglobin,
white blood cell count, creatinine, or liver enzymes were
observed after bosentan or placebo.
|
| Discussion |
|---|
|
|
|---|
Bosentan inhibits ET-induced vascular responses both in vitro and in intact animals.5 17 After blockade of ET receptors, plasma levels of the peptide increase.23 Accordingly, in this study, bosentan but not placebo led to a marked increase in plasma ET. Hence, the dosage of bosentan that was selected on the basis of previous experience in animals and humans20 25 effectively blocked ET receptors.
Baseline plasma ET levels were slightly above normal and increased by a factor of 2.4 after bosentan. Bosentan decreased systolic blood pressure and increased heart rate. Although diastolic blood pressure also tended to decrease, this effect was less pronounced. It is possible that ET contributes to or regulates vascular compliance of larger conduit arteries and, in turn, affects systolic blood pressure in particular. ET also has positive inotropic properties26 ; hence, an ET antagonist might reduce stroke volume. The small increase in heart rate must be due to unloading baroreceptors, with activation of the sympathetic nervous system.
The coronary effects of bosentan were assessed in a diseased segment (>50% stenosis, which was later dilated) and a control segment with angiographically mild or no disease. Bosentan increased coronary artery diameter in control but not in diseased segments. This suggests that endogenous ET contributes to coronary vascular tone. The fact that vasodilation to bosentan was less pronounced in stenotic segments indicates that the vasodilator capacity was impaired or that too much ET is produced in these segments27 and hence that the antagonist was less active than in control segments. Alternatively, it is possible that in severely diseased coronary segments that led to angina and therefore underwent PTCA, ET production, like that of the other local mediators, is downregulated. Under these conditions, an ET antagonist also would have no effect; however, several studies clearly show that especially in the atherosclerotic vessel wall, a high immunostaining for ET indicates large amounts of the peptide.8 27 28 Nitroglycerin did not exert an additional vasodilator effect in the bosentan group, whereas in the placebo group, it markedly increased coronary diameter; thus, in the bosentan group, the segments already had reached their dilator capacity as a result of the application of bosentan, whereas coronary segments of the placebo group remained responsive to the nitrate.
The vasodilation to bosentan was inversely related to plasma LDL, whereas no such correlation was found with placebo. Other lipid fractions did not correlate with the effects of bosentan. It is possible that vasodilation in diseased vessels is impaired and LDL levels only reflect this phenomenon. However, changes in coronary diameter induced by nitroglycerin were not related to plasma LDL, unlike those to bosentan, demonstrating that the relation was specific for bosentan. The definitive interpretation of these results is difficult in this in vivo study. Experimental data as well as in vivo studies in pigs show high levels of ET in hypercholesterolemia, suggesting that an ET antagonist should be particularly effective under these circumstances.28 29 Most likely, with higher local levels of ET, a higher concentration of the competitive antagonist, eg, bosentan, would also be needed to inhibit ET-induced vasoconstriction.
We studied the effects of bosentan 40 minutes after start of the infusion of the drug; we choose this time point on the basis of experience obtained in previous clinical studies with the drug, in which there was a marked effect of bosentan after this period of time.20 23 A dose-response assessment would have been the ideal design to assess the effects of bosentan. However, to minimize the risk and discomfort for the patients associated with the long duration of this invasive study in the catheter laboratory, we decided to assess coronary hemodynamics 40 minutes after administration of a single dose of the drug. Because we observed a clear time-response relation in the parameters assessed continuously during the 40 minutes of observation, ie, blood pressure and coronary blood flow, we are confident that there was a marked effect of bosentan. This is also reinforced by the changes in plasma ET during bosentan infusion. We cannot fully exclude the possibility that we might have seen a stronger effect of the drug if we had been able to wait 50 minutes, which, however, was not possible for ethical reasons. Blood pressure and heart rate decreased in the placebo group, indicating that there was not a completely steady-state situation in this study. However, the design was identical in the two groups, ie, placebo and bosentan; thus, it is unlikely that this influenced the outcome of the study.
Coronary blood velocities did not increase in patients receiving bosentan. Given the vasodilator effects of bosentan in epicardial coronary arteries in which flow was measured, this is not surprising, because flow velocity actually tends to decrease (with a similar coronary vascular resistance) if epicardial vessels dilate. It is possible, however, that we missed vasodilator effects of bosentan in the coronary resistance circulation, because velocities were measured in diseased vessels beyond the stenosis. Measurement of intracoronary Doppler velocity is a widely used method and has been shown to reliably assess coronary blood flow velocity. It is possible, however, that in diseased segments in which flow was measured, the vasodilator capacity of the resistance vessel is reduced because of the stenosis. We gave heparin to our patients before beginning coronary catheterization; this drug can interact with mediators of the vascular endothelium, ie, ET, and decreases plasma ET-1 levels,30 possibly by a nitric oxidemediated mechanism.31 However, because of the experimental protocol, it was not possible to do the study without heparinization of the patients. Because the study was placebo-controlled and all patients received the same amount of heparin, this effect is not likely to influence the results.
These results are important for the pathophysiology of coronary artery disease and for future drug development. Indeed, the vasodilator effects of bosentan suggest that vascular ET contributes to coronary vascular tone. Thus, ET-receptor antagonists might be useful to treat myocardial ischemia. It is possible that during chronic therapy, inhibition of the proliferative effects of ET may be beneficial for structural changes. Hence, long-term studies with ET-receptor antagonists in coronary artery disease are necessary to determine their clinical potential.
| Acknowledgments |
|---|
| Footnotes |
|---|
Received March 31, 1998; revision received July 15, 1998; accepted July 21, 1998.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
D. J. Duncker and R. J. Bache Regulation of Coronary Blood Flow During Exercise Physiol Rev, July 1, 2008; 88(3): 1009 - 1086. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Ikonomidis, E. J. Hilton, K. Payne, A. Harrell, L. Finklea, L. Clark, S. Reeves, R. E. Stroud, A. Leonardi, F. A. Crawford Jr, et al. Selective Endothelin-A Receptor Inhibition After Cardiac Surgery: A Safety and Feasibility Study Ann. Thorac. Surg., June 1, 2007; 83(6): 2153 - 2161. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P.J. Halcox, K. R.A. Nour, G. Zalos, and A. A. Quyyumi Endogenous Endothelin in Human Coronary Vascular Function: Differential Contribution of Endothelin Receptor Types A and B Hypertension, May 1, 2007; 49(5): 1134 - 1141. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. E Pyke and M. E Tschakovsky The relationship between shear stress and flow-mediated dilatation: implications for the assessment of endothelial function J. Physiol., October 15, 2005; 568(2): 357 - 369. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Ergul, J. S. Johansen, C. Stromhaug, A. K. Harris, J. Hutchinson, A. Tawfik, A. Rahimi, E. Rhim, B. Wells, R. W. Caldwell, et al. Vascular Dysfunction of Venous Bypass Conduits Is Mediated by Reactive Oxygen Species in Diabetes: Role of Endothelin-1 J. Pharmacol. Exp. Ther., April 1, 2005; 313(1): 70 - 77. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Rich and V. V. McLaughlin Endothelin Receptor Blockers in Cardiovascular Disease Circulation, November 4, 2003; 108(18): 2184 - 2190. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. W Kenyon and J. M Nappi Bosentan for the Treatment of Pulmonary Arterial Hypertension Ann. Pharmacother., July 1, 2003; 37(7): 1055 - 1062. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. Gottlieb The neurohormonal paradigm:have we gone too far? J. Am. Coll. Cardiol., May 7, 2003; 41(9): 1458 - 1459. [Full Text] [PDF] |
||||
![]() |
P.J. Cowburn and J.G.F. Cleland Endothelin antagonists for chronic heart failure: do they have a role? Eur. Heart J., October 1, 2001; 22(19): 1772 - 1784. [PDF] |
||||
![]() |
C. Ihling, T. Szombathy, B. Bohrmann, M. Brockhaus, H. E. Schaefer, and B. M. Loeffler Coexpression of Endothelin-Converting Enzyme-1 and Endothelin-1 in Different Stages of Human Atherosclerosis Circulation, August 21, 2001; 104(8): 864 - 869. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. R. Bond, B. H. Dorman, M. J. Clair, C. A. Walker, M. L. Pinosky, S. T. Reeves, S. Walton, J. M. Kratz, J. L. Zellner, A. J. Crumbley III, et al. Endothelin-1 during and after cardiopulmonary bypass: Association to graft sensitivity and postoperative recovery J. Thorac. Cardiovasc. Surg., August 1, 2001; 122(2): 358 - 364. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. Spieker, G. Noll, F. T. Ruschitzka, and T. F. Luscher Endothelin receptor antagonists in congestive heart failure: a new therapeutic principle for the future? J. Am. Coll. Cardiol., May 1, 2001; 37(6): 1493 - 1505. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. MacCarthy, N. C. Pegge, B. D. Prendergast, A. M. Shah, and P. H. Groves The physiological role of endogenous endothelin in the regulation of human coronary vasomotor tone J. Am. Coll. Cardiol., January 1, 2001; 37(1): 137 - 143. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. F. Luscher and M. Barton Endothelins and Endothelin Receptor Antagonists : Therapeutic Considerations for a Novel Class of Cardiovascular Drugs Circulation, November 7, 2000; 102(19): 2434 - 2440. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. S. Kyriakides, D. Th. Kremastinos, T. M. Kolettis, A. Tasouli, A. Antoniadis, and D. J. Webb Acute Endothelin-A Receptor Antagonism Prevents Normal Reduction of Myocardial Ischemia on Repeated Balloon Inflations During Angioplasty Circulation, October 17, 2000; 102(16): 1937 - 1943. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z S Kyriakides, D T Kremastinos, E Bofilis, D Tousoulis, A Antoniadis, and D J Webb Endogenous endothelin maintains coronary artery tone by endothelin type A receptor stimulation in patients undergoing coronary arteriography Heart, August 1, 2000; 84(2): 176 - 182. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. Spieker, V. Mitrovic, G. Noll, R. Pacher, M. R. Schulze, J.o. Muntwyler, C. Schalcher, W. Kiowski, T. F. Luscher, and on behalf of the ET 003 Investigators Acute hemodynamic and neurohumoral effects of selective ETA receptor blockade in patients with congestive heart failure J. Am. Coll. Cardiol., June 1, 2000; 35(7): 1745 - 1752. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P.J. Halcox, K. R.A. Nour, G. Zalos, and A. A. Quyyumi Coronary Vasodilation and Improvement in Endothelial Dysfunction With Endothelin ETA Receptor Blockade Circ. Res., November 23, 2001; 89(11): 969 - 976. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1998 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |