(Circulation. 1997;95:1157-1164.)
© 1997 American Heart Association, Inc.
Articles |
the Division of Cardiology (Department of Medicine), William Beaumont Hospital, Royal Oak, Mich.
Correspondence to Robert D. Safian, MD, Director, Interventional Cardiology, William Beaumont Hospital, 3601 W Thirteen Mile Road, Royal Oak, MI 48073.
| Abstract |
|---|
|
|
|---|
Methods and Results Intracoronary Doppler blood flow velocity measurements were obtained with a Doppler Flowire. Basal average peak velocity (bAPV), hyperemic APV (hAPV), diastolic/systolic velocity ratio (DSVR), and coronary flow reserve (CFR) were assessed before intervention, after Rotablator, and after adjunctive PTCA. Complete clinical, angiographic, and Doppler data were obtained in 22 patients. There was a small but significant difference (P=.02) in resting heart rate and mean arterial pressure before and after Rotablator and after adjunctive PTCA. Minimum lumen diameter increased from 0.8±0.1 to 1.5±0.2 to 2.0±0.1 mm (P<.001), corresponding to decreases in diameter stenosis from 72±3% to 41±4% to 36±3% (P<.001). Although bAPV, hAPV, and DSVR increased significantly (P<.001), CFR remained abnormally low in 19 of 22 patients (despite an increase from baseline to post-PTCA). hAPV >30 cm/s was the best Doppler correlate of angiographic success.
Conclusions Rotablator atherectomy and adjunctive PTCA significantly improve distal coronary blood flow velocity and DSVR but not CFR. Failure to normalize CFR could be secondary to parallel increases in bAPV and hAPV, "acquired" microvascular disease due to distal microembolization or spasm, and/or angiographically inapparent dissection or residual stenosis. Adjunctive PTCA contributes significantly to the overall physiological benefit of a combined procedure.
Key Words: blood flow atherosclerosis angioplasty
| Introduction |
|---|
|
|
|---|
| Methods |
|---|
|
|
|---|
Doppler Assessment
After baseline coronary angiography, a 0.014- or 0.018-in Doppler Flowire (Cardiometrics) was placed in the target vessel at least 2 cm distal to the target lesion. Special care was taken to avoid placement into a side branch or poststenotic velocity jet. Baseline flow velocity was recorded once a stable, maximal Doppler signal was obtained and the instantaneous peak velocity tracking correlated with a crisp gray-scale Doppler envelope, as previously described.1 10 11 Once basal flow velocity stabilized for >60 seconds, maximal hyperemic velocity was induced with intracoronary adenosine (10 to 15 µg in the RCA, 20 to 30 µg in the LCA), as previously reported.12 13 Flow velocity spectra were tracked for at least 60 seconds after each adenosine bolus and were analyzed for bAPV, hAPV, continuous DSVR, and CFR, as previously defined.1 After intervention, the basal and hyperemic velocity spectra were monitored until stable, consistent signals were obtained, and APV was recorded after the velocity equilibrated and remained constant for >60 seconds. Doppler flow velocities were obtained
10 minutes after the administration of 200 µg intracoronary nitroglycerin. Measurements were obtained in all patients before intervention, after Rotablator, and after adjunctive PTCA with the Flowire in the same position.
Rotablator Atherectomy and Adjunctive PTCA
All Rotablator atherectomy procedures were performed with a Rotablator C guidewire (Heart Technologies) and a stepped-burr approach, as previously described.14 15 After Rotablator, the C-wire was exchanged for the Doppler Flowire, and Doppler assessment and coronary angiography were repeated. Adjunctive PTCA was performed in all cases to achieve final luminal enlargement, and final Doppler assessment and angiography were repeated as described above.
Quantitative Angiography
The single view that identified the most severe stenosis was selected for quantitative analysis, and measurements of MLD, reference diameter, lesion length, and DS were obtained by computerized edge detection, as previously described.16 Measurements were performed at baseline, immediately after Rotablator, and after adjunctive PTCA. Antegrade flow was graded by standard TIMI criteria.17 Procedural success was defined as final DS <50% in the absence of a major complication (death, Q-wave myocardial infarction, coronary bypass surgery).
Statistical Analysis
Continuous data are reported as mean±SEM unless stated otherwise. ANOVA was used to compare baseline, post-Rotablator, and post-PTCA Doppler, hemodynamic, and angiographic variables. A two-tailed paired Student's t test with Bonferroni's correction was used to compare mean values if significant by ANOVA. Conventional Student's t test was used to compare mean values of unpaired data for DS, MLD, and DSVR. Linear regression was used to evaluate the relationship between Doppler, clinical, hemodynamic, and angiographic data. Differences were considered significant if P<.05.
| Results |
|---|
|
|
|---|
|
Hemodynamic Performance
All patients were hemodynamically stable and asymptomatic at rest at the time of intervention. There were small but statistically significant differences in resting heart rate (P=.02) and mean arterial pressure (P=.02) from baseline to after Rotablator to after adjunctive PTCA (Fig 1
).
|
Angiographic Assessment
Procedural success was achieved in all 22 patients. Fig 2
shows representative angiographic and spectral displays at various stages of the procedure. Quantitative angiography revealed an increase in MLD from 0.8±0.1 mm at baseline to 1.5±0.2 mm after Rotablator to 2.0±0.1 mm after adjunctive PTCA (P<.001), corresponding to decreases in DS from 72±3% to 41±4% and to 26±3%, respectively (P<.001). Two patients had transient TIMI 2 flow (Table 2
, patients 2 and 7) after Rotablator, which improved to TIMI 3 flow after intracoronary nitroglycerin and before assessment of distal flow velocity; TIMI 3 flow was present at baseline, after Rotablator, and after adjunctive PTCA at all other times of assessment. Single burrs were used in 15 patients and multiple burrs in 7; final burr-to-artery ratio was 0.7±0.3 (mean±SD). The mean lesion length was 9.4±5.1 mm (mean±SD) (range, 3.0 to 20.4 mm). Moderate to severe calcification was evident fluoroscopically in 6 of 22 patients (27%) in the target vessel. No patient had sustained "no reflow," flow-limiting dissection, coronary perforation, or persistent spasm after Rotablator or adjunctive PTCA.
|
|
Assessment of Distal Coronary Flow Velocity
Stable velocity signals were obtained 10±7 minutes after each intervention; there was no difference after Rotablator or adjunctive PTCA with regard to the time to achieving a stable signal. bAPV increased from 17.8±1.9 to 28.8±3.6 cm/s after Rotablator to 39.5±3.7 cm/s after adjunctive PTCA (P<.001) (Fig 3
). bAPV increased in 18 patients (82%) after Rotablator, with further increases in 19 patients (86%) after PTCA. hAPV increased from 21.1±2.5 cm/s at baseline to 37.0±4.7 cm/s after Rotablator to 53.4±5.0 cm/s after PTCA (P<.001) (Fig 3
). hAPV increased in 19 patients (86%) after Rotablator, with further increases in 18 patients (81%) after adjunctive PTCA. hAPV increased in all patients from baseline to after PTCA; the 4 patients with no sequential increase after Rotablator (2 patients, no change; 2 patients, trivial decrease) (Table 2
) had a threefold increase, on average, in hAPV from baseline to after Rotablator. There was no difference in distal reference vessel diameter at the site of Doppler assessment from baseline (2.3±0.2 mm) to after Rotablator (2.1±0.2 mm) to after PTCA (2.3±0.3) (P=NS), suggesting that changes in basal and hyperemic blood flow velocity were due to increases in volumetric flow. hAPV >30 cm/s was observed in 4 patients (18%) before intervention, 12 patients (55%) after Rotablator, and 21 patients (95%) after adjunctive PTCA (Fig 4
). Patients with hAPV >30 cm/s after Rotablator had a significantly lower DS (33.8±4.7 versus 55.5±5.0%, P<.01) and larger MLD (1.3±0.1 versus 1.0±0.1 mm, P<.01) than patients with hAPV <30 cm/s.
|
|
Coronary Flow Reserve
Baseline CFR was 1.2±0.1 (range, 0.9 to 1.6); CFR was <2.0 in all patients, consistent with the physiological significance of the target lesion. Although CFR increased to 1.3±0.1 after Rotablator and to 1.5±0.1 after adjunctive PTCA (P<.01) (Fig 5
), CFR >2.0 was achieved in only 3 patients (14%) after adjunctive PTCA. The final DS for the 3 patients with final CFR >2.0 was 37±3%, which was similar to the final DS of 28±3% for the 19 patients with final CFR <2.0. The failure to further increase CFR to "normal" levels was associated with parallel increases in bAPV and hAPV; compared with baseline, bAPV increased 157% and hAPV increased 209% after adjunctive PTCA.
|
Phasic Coronary Flow Parameters
DSVR increased from 1.3±0.1 before intervention to 1.5±0.1 after Rotablator to 1.8±0.1 after PTCA (P<.01). Normal DSVR (>1.7 in the LCA, >1.4 in the RCA) was observed in 5 patients (23%) before intervention, in 11 patients (50%) after Rotablator, and in 12 patients (55%) immediately after adjunctive PTCA. When changes in DSVR were stratified for the RCA and LCA, there was a significant increase in DSVR only in the LCA (P<.001) (Fig 6
): Whereas 10 of 17 patients (59%) achieved DSVR >1.7 in the LCA, only 1 of 5 patients (20%) achieved DSVR >1.4 in the RCA (See Table 2
and Fig 6
).
|
Effect of Baseline Characteristics and Angiographic and Hemodynamic Variables on Measured Doppler Variables After Adjunctive Angioplasty
There was no relationship between age, sex, history of hypertension, presence of multivessel disease, or smoking status and hAPV or CFR after adjunctive PTCA. Final hAPV and CFR after PTCA did not correlate with percent DS, MLD, or lesion length. Interestingly, although bAPV and hAPV were not associated with heart rate or mean arterial pressure, postprocedure CFR weakly correlated with mean arterial pressure (r=.55, P=.007) after adjunctive PTCA.
| Discussion |
|---|
|
|
|---|
Coronary Flow Velocity After Rotablator
In the absence of changes in vessel diameter, APV is a surrogate for volumetric coronary flow.2 The increase in APV in this study is similar to those reported after successful PTCA,1 24 laser angioplasty,3 and directional atherectomy25 and probably represents increased distal flow. Distal APV improves almost immediately after the procedure and correlates with successful luminal enlargement after angioplasty.1 2 The increase in flow after Rotablator may be secondary to relief of stenosis severity and/or endogenous release of adenosine secondary to endothelial activation leading to arteriolar vasodilation.26 Interestingly, transient "slow reflow" (TIMI flow grade 2) was seen immediately after Rotablator in 2 patients (Table 2
, patients 2 and 7). These 2 patients had residual stenoses of 61% and 52% after Rotablator, respectively, compared with 40% for the remaining 20 patients. Angiographically, the lesions for these 2 patients were complex (B2, C) and long (18.5 mm, 20.4 mm), possibly representing a greater atheroma burden in these patients.4 bAPV and hAPV decreased in both patients 8 to 10 minutes after Rotablator, yet by the time of Doppler assessment, TIMI 3 flow had been restored by intracoronary nitroglycerin and the time window necessary to reposition the Doppler guidewire. Furthermore, after PTCA there was a substantial increase in bAPV (15 to 24 cm/s, 16 to 29 cm/s) and hAPV (15 to 39 cm/s, 17 to 36 cm/s) along with unchanged TIMI 3 flow. The cause of "no reflow" after Rotablator remains speculative but could be secondary to severe spasm,18 21 unrecognized dissection,14 microcavitation,7 or microparticulate embolization.5 14 21 Because of the transient nature of the slow reflow in both patients and substantial improvement in basal and hyperemic flow after adjunctive PTCA, it appears that microembolization did not have a sustained adverse effect on distal flow. On the basis of this observation, transient burr-induced microcavitations or spasm are likely explanations for transient slow flow after Rotablator.
DSVR After Rotablator
The normal diastolic predominance of coronary flow is lost in the presence of a severe epicardial stenosis,27 but successful PTCA results in immediate normalization of DSVR.1 2 The increase in DSVR in this study is consistent with reports after other techniques.1 2 24 25 Although an experimental study in dogs reported a significant decrease in DSVR after microembolization without changes in mean flow,28 DSVR increased in our study, suggesting that microparticulate debris did not have a profound adverse effect on coronary flow dynamics. This change was noted, however, only in the LCA, in which the diastolic predominance of coronary flow is most pronounced. DSVR normalized2 in the LCA in 11 of 17 patients (65%).
Improvement in the diastolic predominance of coronary flow velocity is heterogeneous. In addition to epicardial factors, hemodynamic, microcirculatory, and myocardial influences most likely play a role in changes of the DSVR. An increase in myocardial contractility, in particular, would lead to a decrease in the systolic component of coronary flow and a resultant increase in the DSVR if the diastolic flow velocity remained unchanged. Small amounts of microparticulate debris may incite vasomotor changes leading to such an increase, whereas a large amount of embolization would be expected to cause significant ischemia, resulting in impaired contractility (and an increase in systolic flow) in the myocardial beds studied. The systolic velocity integral was not assessed to isolate the systolic flow velocity changes that occurred. Nevertheless, the observed improvement in DSVR is most likely the result of both an increase in the diastolic velocity due to a decrease in the epicardial stenosis and a decrease in the systolic velocity due to an improvement in myocardial contractility immediately after the procedure.
CFR After Rotablator
CFR, unlike bAPV, hAPV, and DSVR, remained abnormally low after Rotablator and adjunctive PTCA in this study, although there was a small but statistically significant increase in CFR from baseline to post-PTCA levels. These results are similar to those reported after PTCA29 and other atherectomy devices.1 3 Failure to normalize CFR may be due to an increase in basal coronary blood flow velocity, decreased capacity of the arteriolar bed to vasodilate (microvascular disease), resistance to hyperemic flow due to angiographically inapparent persistent stenosis or dissection,29 and/or diffuse residual atherosclerosis.30 In this study, "acquired microvascular disease" due to microparticle embolization and/or microvascular spasm cannot be totally excluded. However, the unexplained substantial increase in basal flow velocity to >150% above baseline levels undoubtedly contributed to impaired CFR ratios after Rotablator. As with other interventions, CFR immediately after Rotablator and adjunctive PTCA does not correlate with angiographic or other Doppler parameters. Post-PTCA hAPV >25 to 30 cm/s, seen in angiographically normal vessels,31 correlated more closely with procedural success than CFR, and substantial increases in hAPV support the elimination of hemodynamically significant stenoses in these patients. Nevertheless, recent preliminary studies suggest that impaired CFR after successful PTCA can be improved by stenting32 33 ; these data suggest that persistent abnormal CFR after Rotablator may be due, at least in part, to angiographically inapparent significant residual stenosis.
Effects of Adjunctive PTCA on Doppler Variables After Rotablator
APV, DSVR, DS, and MLD significantly improve after adjunctive angioplasty, findings similar to those reported after laser angioplasty.3 Most of the gain in lumen area after Rotablator and adjunctive PTCA is secondary to PTCA.14 34 The sequential improvement after balloon angioplasty may be explained by lumen enlargement, treatment of a dissection, transient effects of microcavitations, relief of vasospasm induced by Rotablator, or platelet adhesion after exposure of the media leading to local vasoactive factors that may transiently limit the flow response. The physiological improvement after combined Rotablator and adjunctive PTCA raises the question as to whether PTCA alone would lead to similar physiological improvement.
Lack of Correlation of Doppler and Angiographic Variables After Rotablator
In this study, there was no correlation between hyperemic blood flow velocity or CFR and quantitative assessment of stenosis severity before or after intervention, which is consistent with prior studies.35 36 37 CFR immediately after PTCA or Rotablator and adjunctive PTCA does not reflect the success of the procedure in removing the physiological obstruction to blood flow. A better measure of success (not stenosis severity) appears to be hAPV: A "normal" hAPV (>30 cm/s) was achieved in 95% of patients with "angiographic success." Impaired distal hyperemic response after Rotablator may identify a persistent suboptimal physiological result after the procedure; this is supported by a significantly higher residual stenosis after Rotablator in the group with hAPV <30 cm/s (Fig 4
). It will be important to assess whether clinical outcome correlates with these postprocedure blood flow velocities.
Limitations
There are several potential limitations of this study. First, proper use of the Doppler guidewire requires careful positioning of the transducer parallel to blood flow, and technical problems may influence accuracy.10 13 35 To minimize these problems, meticulous attention was given to careful positioning of the tip of the guidewire to maximize the Doppler signal, as previously reported.10 11 Second, alterations in arterial blood pressure may have a modest parallel effect on basal and hyperemic flow velocities,38 but the decrease in arterial pressure in this study would be expected to decrease flow velocity. However, bAPV and hAPV increased in this study, which must have occurred despite the decrease in blood pressure. It is possible, however, that hAPV did not increase to maximum levels because of an overriding effect of lower MAP, which would potentially lead to a relative decrease in hyperemic flow.38 Nevertheless, CFR should not change, because bAPV and hAPV would be altered to a parallel and similar degree. Fractional flow reserve was not assessed because of the inaccuracies of obtaining distal coronary pressures through a 2.2F catheter; the 0.018-in end-hole wire remains experimental. Third, coronary flow velocity may increase with increases in preload. Although filling pressures were not measured, it is unlikely that they changed significantly during the procedure. Furthermore, although changes in preload could confound bAPV and CFR, they would not affect hyperemic flow velocity.38 Fourth, the assessment of CFR may be confounded by unrecognized microvascular disease; however, patients with predisposing factors for abnormal vasodilator reserve were excluded. Furthermore, reasonable vasodilatory reserve is inferred from the 2.2-fold increase in hAPV after adjunctive PTCA compared with pre-Rotablator levels (Fig 3
). Although the increased flow may be due to removal of the epicardial obstruction alone, it is manifested by decreases in arteriolar resistance and represents vasodilation of the microvasculature. Finally, translesional velocity gradients and "normal" reference vessel measurements were not obtained; therefore, compensatory flow velocity changes in adjacent territories remain undefined.
Conclusions
Rotablator atherectomy and adjunctive PTCA significantly improve basal and hyperemic blood flow velocity and restore the diastolic predominance of coronary blood flow. Although CFR increases, it is still impaired despite excellent luminal enlargement by quantitative angiography. Further studies are needed to differentiate angiographically inapparent, significant residual stenosis or impaired microcirculation from transient increases in basal flow velocity as a cause of abnormal CFR.
| Selected Abbreviations and Acronyms |
|---|
|
| Acknowledgments |
|---|
Received April 23, 1996; revision received October 7, 1996; accepted October 23, 1996.
| References |
|---|
|
|
|---|
2. Ofili EO, Kern MJ, Labovitz AJ, St Vrain JA, Segal J, Aguirre FV, Castello R. Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endolumen enlargement by angioplasty. J Am Coll Cardiol. 1993;21:308-316.[Abstract]
3. Segal J. Applications of coronary flow velocity during angioplasty and other coronary interventional procedures. Am J Cardiol. 1993;71:17D-25D.[Medline] [Order article via Infotrieve]
4.
Ellis SG, Popma JJ, Buchbinder M, Franco I, Leon MB, Kent KM, Pichard AD, Satler LF, Topol EJ, Whitlow PL. Relation of clinical presentation, stenosis morphology, and operator technique to the procedural results of rotational atherectomy and rotational atherectomy-facilitated angioplasty. Circulation. 1994;89:882-892.
5. Prevosti LG, Cook JA, Unger EF, Sheffield CD, Almagor Y, Bartorelly AL, Leon MB. Particulate debris from rotational atherectomy: size distribution and physiological effects. Circulation. 1988;82(suppl II):II-83. Abstract.
6. Friedman HZ, Elliott MA, Gottlieb GJ, O'Neill WW. Mechanical rotary atherectomy: the effects of microparticle embolization on myocardial blood flow and function. J Intervent Cardiol. 1989;2:77-83.
7. Zotz RJ, Erbel R, Philipp A, Judt A, Wagner H, Lauterborn W, Meyer J. High-speed rotational angioplasty-induced echo contrast in in vivo and in vitro optical analysis. Cathet Cardiovasc Diagn. 1992;26:98-109.[Medline] [Order article via Infotrieve]
8. Hansen DD, Auth DC, Vracko R, Ritchie JL. Rotational atherectomy in atherosclerotic rabbit iliac arteries. Am Heart J. 1988;15:160-165.
9. Ling FS, Brennan JJ, Cleman MW, Cabin HS. Physiologic assessment of ostial left circumflex coronary artery disease using a Doppler guidewire before and after rotational atherectomy facilitated angioplasty. Cathet Cardiovasc Diagn. 1994;32:53-57.[Medline] [Order article via Infotrieve]
10.
Doucette JW, Corl D, Payne HM, Flynn AE, Goto M, Nassi M, Segal J. Validation of a Doppler guide wire for intravascular measurement of coronary artery blood flow velocity. Circulation. 1992;85:1899-1911.
11. Vanyi J, Bowers TR, Jarvis G, White CW. Can an intracoronary Doppler wire accurately measure changes in coronary blood flow velocity? Cathet Cardiovasc Diagn. 1993;29:240-246.[Medline] [Order article via Infotrieve]
12.
Wilson RF, Wyche K, Christensen BV, Zimmer S, Laxson DD. The effects of adenosine on the human coronary circulation. Circulation. 1990;82:1595-1606.
13. Kern MJ, Deligonul U, Tatineni S, Serota H, Aguirre F, Hilton TC. Intravenous adenosine: continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease. J Am Coll Cardiol. 1991;18:718-729.[Abstract]
14.
Safian RD, Niazi KA, Strzelecki M, Lichtenberg A, May M, Juran N, Freed M, Ramos R, Gangadharan V, Grines CL, O'Neill WW. Detailed angiographic analysis of high-speed mechanical rotational atherectomy in human coronary arteries. Circulation. 1993;88:961-968.
15. Teirstein PS, Warth DC, Haq N, Jenkins NS, McCowan LC, Aubanel-Reidel P, Morris N. High speed rotational coronary atherectomy for patients with diffuse coronary artery disease. J Am Coll Cardiol. 1991;18:1694-1701.[Abstract]
16. Popma JJ, van den Berg EK, Dehmer GJ. Long-term outcome of patients with asymptomatic restenosis after percutaneous transluminal coronary angioplasty. Am J Cardiol. 1988;62:1298-1299.[Medline] [Order article via Infotrieve]
17. The TIMI Study Group. The Thrombolysis in Myocardial Infarction (TIMI) trial. N Engl J Med. 1985;312:932-936.[Medline] [Order article via Infotrieve]
18.
Dietz U, Erbel R, Rupprecht H, Weidmann S, Meyer J. High frequency rotational ablation: an alternative in treating coronary artery stenoses and occlusions. Br Heart J. 1993;70:327-336.
19. Fourrier JL, Bertrand ME, Auth DC, Lablanche JM, Gommeaux A, Brunetaud JM. Percutaneous coronary rotational angioplasty in humans: preliminary report. J Am Coll Cardiol. 1989;14:1278-1286.[Abstract]
20. Ahn SS, Auth D, Marcus DR, Moore WS. Removal of focal atheromatous lesions by angioscopically guided high-speed rotary atherectomy: preliminary experimental observations. J Vasc Surg. 1988;7:292-300.[Medline] [Order article via Infotrieve]
21. Zacca NM, Raizner AE, Noon GP, Short HD III, Weilbaecher DG, Gotto AM, Roberts R. Treatment of symptomatic peripheral atherosclerotic disease with a rotational atherectomy device. Am J Cardiol. 1989;63:77-80.[Medline] [Order article via Infotrieve]
22. Zacca NM, Raizner AE, Noon GP, Short HD III, Weilbaecher DG, Gotto AM, Roberts R. Short term follow up of patients treated with a recently developed rotational atherectomy device and in vivo assessment of the particles generated. J Am Coll Cardiol. 1988;11:109A. Abstract.
23. Laarman GJ, Serruys PW. Percutaneous coronary rotational angioplasty: preliminary clinical and quantitative imaging results. Int J Card Imaging. 1991;7:47-54.[Medline] [Order article via Infotrieve]
24. Kern MJ, Donohue TJ, Bach RG, Caracciolo EA, Flynn MS, Aguirre FV. Clinical applications of the Doppler coronary flow velocity guidewire for interventional procedures. J Intervent Cardiol. 1993;6:345-363.[Medline] [Order article via Infotrieve]
25. Younis L, Kern MJ, Bach RG, Donohue TJ, Aguirre FV, Mechem C, Cauley M, Stonner T. Post-procedural normalization of coronary flow dynamics following successful atherectomy, PTCA and stenting: analysis by intracoronary spectral Doppler. J Am Coll Cardiol. 1993;21:79A. Abstract.
26.
Takashima S, Hori M, Kitakaze M, Hiroshi S, Inoue M, Kamada T. Superoxide dismutase restores contractile and metabolic dysfunction through augmentation of adenosine release in coronary microembolization. Circulation. 1993;87:982-995.
27.
Kajiya F, Tsujioka K, Ogasawara Y, Wada Y, Matsuoka S, Kanazawa S, Hiramatsu O, Tadaoka S, Goto M, Fujiwara T. Analysis of flow characteristics in poststenotic regions of the human coronary artery during bypass graft surgery. Circulation. 1987;76:1092-1100.
28. Bowers TR, Vanyi J, Jarvis G, White CW. Is the coronary diastolic/systolic velocity ratio altered by microvasculature obstruction? J Clin Res. 1992;40:748A. Abstract.
29.
Wilson RF, Johnson MR, Marcus ML, Aylward PEG, Skorton DJ, Collins S, White CW. The effect of coronary angioplasty on coronary flow reserve. Circulation. 1988;77:873-885.
30.
Bates ER, Aueron FM, Legrand V, Lefree MT, Mancini JGB, Hodgson J, Vogel RA. Comparative long-term effects of coronary artery bypass graft surgery and percutaneous transluminal coronary angioplasty on regional coronary flow reserve. Circulation. 1985;72:833. Abstract.
31. Ofili EO, Labovitz AJ, Kern MJ. Coronary flow velocity dynamics in normal and diseased arteries. Am J Cardiol. 1993;71:3D-9D.[Medline] [Order article via Infotrieve]
32. Kern MJ, Aguirre FV, Donohue TJ, Bach RG, Caracciolo EA, Wolford TL, Khoury A, Mechem C. Impact of residual lumen narrowing on coronary flow after angioplasty and stent: intravascular ultrasound Doppler and imaging data in support of physiologically-guided coronary angioplasty. Circulation. 1995;92:263A. Abstract.
33. Bowers TR, Safian RD, Stewart RE, Benzuly KH, Shoukfeh MM, O'Neill WW. Normalization of coronary flow reserve after stenting, but not after PTCA. J Am Coll Cardiol. 1996;27:19A. Abstract.
34. Zimarino M, Corcos T, Favereau X, Elbaz N, Brossais S, Tamburino C, Toussaint M, Guerin Y, Eiferman C, Barthelemy M, Souffrant G. Rotational coronary atherectomy with `adjunctive' balloon angioplasty: which is the primary and which is the adjunctive technique? J Am Coll Cardiol. 1994;23:285A. Abstract.
35. Donohue TJ, Kern MJ, Aguirre FV, Bach RG, Wolford T, Bell CA, Segal J. Assessing the hemodynamic significance of coronary artery stenoses: analysis of translesional pressure-flow velocity relationships in patients. J Am Coll Cardiol. 1993;22:449-458.[Abstract]
36. Ofili EO, Karim AM, Kern MJ, Deligonul U, Aguirre F, Serota H, Tatineni S. Simultaneous comparison of intracoronary spectral and zero-cross flow velocity measurements by Doppler angioplasty guidewire and catheter techniques. J Am Coll Cardiol. 1991;17:124A. Abstract.
37. Tron C, Kern MJ, Donahue TJ, Bach RG, Aguirre FV, Caracciolo EA, Moore JA. Comparison of quantitative angiographically derived and measured translesional pressure and flow velocity in coronary artery disease. Am J Cardiol. 1995;75:111-117.[Medline] [Order article via Infotrieve]
38.
McGinn AL, White CW, Wilson RF. Interstudy variability in coronary flow reserve: the importance of heart rate, arterial pressure, and ventricular preload. Circulation. 1990;81:1319-1330.
This article has been cited by other articles:
![]() |
G. Heusch, P. Kleinbongard, D. Bose, B. Levkau, M. Haude, R. Schulz, and R. Erbel Coronary Microembolization: From Bedside to Bench and Back to Bedside Circulation, November 3, 2009; 120(18): 1822 - 1836. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Herrmann, M. Haude, A. Lerman, R. Schulz, L. Volbracht, J. Ge, A. Schmermund, H. Wieneke, C. von Birgelen, H. Eggebrecht, et al. Abnormal Coronary Flow Velocity Reserve After Coronary Intervention Is Associated With Cardiac Marker Elevation Circulation, May 15, 2001; 103(19): 2339 - 2345. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Erbel and G. Heusch Coronary microembolization J. Am. Coll. Cardiol., July 1, 2000; 36(1): 22 - 24. [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1997 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |