Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1997;95:1138-1144

This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Verin, V.
Right arrow Articles by Rutishauser, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Verin, V.
Right arrow Articles by Rutishauser, W.

(Circulation. 1997;95:1138-1144.)
© 1997 American Heart Association, Inc.


Articles

Feasibility of Intracoronary ß-Irradiation to Reduce Restenosis After Balloon Angioplasty

A Clinical Pilot Study

Vitali Verin, MD; Philip Urban, MD; Youri Popowski, MD; Michael Schwager; Philippe Nouet; Pierre A. Dorsaz, PhD; Pascal Chatelain, MD; John M. Kurtz, MD; Wilhelm Rutishauser, MD

the Cardiology Center (V.V., P.U., P.A.D., P.C., W.R.) and Division of Radiation Oncology (Y.P., P.N., J.M.K.), University Hospital, Geneva; and Schneider (Europe) AG (M.S.), Bulach, Switzerland.

Correspondence to Philip Urban, MD, Cardiology Center, University Hospital, 1211 Geneva 14, Switzerland.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background With the aim of decreasing the incidence of restenosis after coronary balloon angioplasty, we developed a technique of intracoronary ß-irradiation using an endoluminally centered pure metallic 90Y source. The purpose of the present study was to evaluate the clinical feasibility and safety profile of this approach with a dose of 18 Gy delivered to the inner arterial surface.

Methods and Results Between June 21 and November 15, 1995, fifteen patients (6 women and 9 men; mean age, 71±5 years) underwent intracoronary ß-irradiation immediately after a conventional percutaneous transluminal coronary angioplasty (PTCA) procedure. The PTCA/irradiation procedure was technically feasible in all attempted cases, and the delivery of the 18 Gy dose was accomplished without complications. In 4 patients, the intervention was completed through intra-arterial stent implantation because of dissection induced by the initial PTCA. During the follow-up period of 178±17 days (range, 150 to 225 days), no complication occurred that could be attributed to radiation therapy. No aneurysm or angiographically detectable thrombus was observed in any of the irradiated arterial segments. The clinical event rate (4 of 15 patients underwent further target lesion revascularization) and the angiographic follow-up (6 of 15 patients had a >50%-diameter stenosis at the previously treated site) did not suggest a marked impact on the expected restenosis rate.

Conclusions This early experience demonstrates that our approach is feasible, and no side effects attributable to radiation were noted during a 6-month period of follow-up. Whether higher doses of ß-irradiation will favorably affect post-PTCA restenosis in patients must await further evaluation.


Key Words: angioplasty • coronary disease • radioisotopes


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
It is well established that the long-term benefit of percutaneous transluminal coronary angioplasty (PTCA) is compromised by the occurrence of restenosis in 30% to 50% of patients.1 2 This contributes to limitation of application of the procedure to relatively simple clinical cases (usually one or two stenotic sites) and leads to significant additional morbidity and costs related to relapses. Pharmacological approaches to restenosis prevention have been disappointing,3 4 5 and only stents have been conclusively shown to have a limited but favorable impact.6 7 Several recent studies have shown the efficacy of intra-arterial {gamma}-irradiation in animal models of postangioplasty restenosis8 9 10 and its applicability in human femoral arteries.11 12 We developed a novel technique of endovascular ß-irradiation using an endoluminally centered pure metallic 90Y source13 14 15 that can be used in an ordinary catheterization laboratory environment. Experimental evaluation of this approach in the hypercholesterolemic rabbit model demonstrated marked efficacy of an 18-Gy radiation dose for neointimal hyperplasia inhibition.15 The purpose of this pilot study was to evaluate in a clinical setting (1) the feasibility of intra-arterial ß-radiation delivery and (2) the safety of an 18-Gy ß-radiation dose delivered to the inner arterial surface during a 6-month follow-up period.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Radiation Delivery System
The intra-arterial ß-radiation delivery system that we described previously14 15 consists of two principal working elements: a 90Y ß-emitting source (half-life, 64.1 hours; maximal energy, 2.284 Mev) and a centering balloon that allows homogeneous radiation dose distribution to the vessel wall (Schneider-Europe AG).

The radioactive source consists of a 29-mm-long flexible coil with an outer diameter of 0.34 mm (0.014 in) manufactured from titanium-coated pure yttrium wire of 0.1-mm diameter (Fig 1ADown). It is secured at the end of a 0.014-in thrust wire between two (distal and proximal) radiopaque tungsten markers, which allows excellent flexibility of the entire system and permits precise localization of the source under fluoroscopy.




View larger version (160K):
[in this window]
[in a new window]
 
Figure 1. A, Yttrium coil fixed on the extremity of a thrust wire. The coil (arrows) is made of titanium-coated pure yttrium wire. B, Centering balloon. The four interconnecting chambers allow centering of the source lumen relative to the arterial lumen. Note the 20-mm-long distal tip of this device, ensuring its "monorail" introduction and the three radiopaque tungsten markers situated at sites of balloon waists (arrows).

The centering device is designed to obtain a central position of the flexible 90Y source inside the arterial lumen (Fig 1BUp). It consists of a 30-mm-long segmented balloon with four interconnected compartments mounted on a double-lumen plastic shaft with an internal (source) blind lumen diameter of 0.40 mm (0.016 in). The 20-mm-long distal tip of this device enables its introduction in a monorail fashion over a conventional 0.014-in angioplasty guide wire. Three radiopaque tungsten markers are located at the balloon waists and allow positioning of the device at the site of the previous angioplasty using fluoroscopy. A flexible stainless steel stylet is placed inside the source lumen of the centering device to optimize tracking of the system through the guiding catheter and the target coronary artery. It is withdrawn before source insertion.

The activity of 90Y sources used varied between 6 and 30 mCi. During the time intervals between procedures, the sources were stored inside a shielding container. A Luer connector established continuity between the centering device source lumen and the inner lumen of the shielding container, allowing easy manual advancement of the source.

Because the half-life of 90Y is 64 hours, the useful clinical life of a source after activation is {approx}1 week.

Procedure
All interventions were done with the use of local 1% lidocaine anesthesia, anticoagulation with heparin, aspirin, and sedation with benzodiazepines and morphine as needed, according to current practice. After an ordinary successful PTCA procedure was performed through a 7F or an 8F guiding catheter, a centering device with the same diameter as the balloon that was used for angioplasty was inserted in the lumen of the artery and positioned to fully cover the PTCA segment length. After withdrawal of the stylet from the centering device source lumen, the centering balloon was then inflated (Fig 2Down) with contrast medium (iohexol 518 mg/mL, Schering AG) at a pressure of 5 bar. If a dummy 89Y wire could be advanced into and retrieved without difficulty from the inflated centering balloon, the 90Y source was then advanced into the centering device up to the stress point and left in this position for the time necessary to apply the 18-Gy inner arterial surface dose. Fluoroscopy was used to confirm the correct position of the source inside the centering balloon (Fig 2Down). After irradiation, stents were used as needed to improve unsatisfactory results.





View larger version (316K):
[in this window]
[in a new window]
 
Figure 2. Endoluminal ß-irradiation of right coronary artery (patient 15). Left anterior oblique view. A, Tight right coronary artery stenosis. B, PTCA with 3.5-mm PTCA balloon. C, Intracoronary irradiation procedure. The four compartments of the centering balloon are inflated with contrast medium. The ß-emitting 90Y source is situated inside the centering balloon. Note that the length of the radioactive segment is delimited by two radiopaque tungsten markers (arrowheads). The centering balloon radiopaque waists (arrows) confirm the correct centering of 90Y source inside the artery. D, Good immediate angiographic result of PTCA/irradiation procedure. E, Follow-up: no restenosis at 6 months.

Two cardiologists, one radiation oncologist, and one technician remained in the catheterization laboratory during the entire procedure. Only routine radioprotection measures were used. During intracoronary irradiation, the radiation dose in contact with the patient's right chest side was 24±7 µSv/h (range, 15 to 30), and no radiation was detectable at the level of the operator's head. In comparison, during fluoroscopy in the same positions, the radiation doses were 45±25 µSv/h (range, 30 to 100) and 20±3 µSv/h (range, 15 to 25), respectively (Monitor 4, S.E. International).

Selection of Patients
Patients >64 years old who were scheduled to undergo angioplasty of one of the native coronary arteries because of angina were eligible for the study. The target lesion was required to have a >=50% diameter stenosis as determined with quantitative coronary angiography (QCA), to be <20 mm long, and to be located in a vessel with a >2.5 mm reference diameter.

Patients were excluded from the study enrollment for (1) contraindication to bypass surgery if needed, (2) anticipated difficulties with long-term follow-up, or (3) extreme tortuosity of the coronary artery proximal to the target lesion. Additional periprocedural exclusion criteria were (4) failed PTCA, (5) failed intra-arterial centering balloon positioning, and (6) failed dummy wire insertion or retrieval. Patient baseline clinical characteristics are presented in Table 1Down. Indications for stent placement were those currently used in our institution and included (1) "bail-out" situations (major dissection and/or reduced flow after PTCA and intracoronary irradiation) and (2) insufficient angiographic result with a significant residual stenosis. After the procedure, long-term aspirin (100 mg daily) was administered to all patients. In case of stent implantation, ticlopidine (500 mg daily) was also administered for 1 month. The study was carried out according to the principles of the Declaration of Helsinki and with the approval of the Ethical Review Board of the University Hospital of Geneva. Written informed consent was obtained from each patient.


View this table:
[in this window]
[in a new window]
 
Table 1. Patients' Baseline Clinical and Treatment Characteristics

Clinical and Angiographic Follow-up
Patients and/or their physicians were contacted by telephone at 1, 3, and 6 months after the procedure. Clinical examination and exercise testing were performed before the second coronary angiography at 6 months. When prompted by recurrent symptoms or signs of ischemia, the follow-up angiography was done before the 6-month time point. All of the angiograms were analyzed with the help of a QCA analysis system (AWOS, Siemens). Restenosis was considered to have occurred if the percent diameter stenosis was >50%. The following were scored as clinical events if they occurred between the time of the initial procedure and the 6-month follow-up: death, cerebrovascular accident, myocardial infarction, or revascularization of the previously treated lesion.

Statistical Analysis
Values are given as mean±SD.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Between June 21 and November 15, 1995, fifteen patients (6 women and 9 men; mean age, 71±5 years) underwent intracoronary ß-irradiation with an intra-arterially centered 90Y source immediately after a conventional PTCA procedure (Table 1Up).

Procedural and Early Clinical Outcome
None of the selected patients were excluded from the study on the basis of periprocedural exclusion criteria. In all, the PTCA/irradiation procedure was technically feasible, and the delivery of the 18-Gy dose to the inner arterial surface was accomplished without complications.

In 2 patients, the irradiated lesions were situated in relatively distant arterial segments (right posterolateral artery in patient 14 and right coronary bifurcation distal to venous bypass graft anastomosis in patient 12). Centering balloon positioning followed by dose delivery was uneventful in both.

In 11 patients (Table 1Up), the dose was delivered during a single centering balloon inflation. In 4 of the patients, because of poor tolerance to prolonged inflation, the delivery to the 18-Gy dose was achieved by a sequence of two or three balloon inflations with source withdrawal and repositioning as needed. The total exposure time per patient was 391±206 seconds (range, 153 to 768 seconds), and the entire intracoronary irradiation procedure prolonged the ordinary PTCA procedure by an additional 10 to 30 minutes. In 4 patients, the intervention was completed by intracoronary stent implantation (Johnson and Johnson Interventional Systems Co) because of major dissection induced by the initial balloon angioplasty in two patients (bail-out) and because of a suboptimal angiographic result with a significant residual stenosis in the other two patients.

No immediate or in-hospital complications were observed in the patients, and all were discharged at 1 to 7 days after the intervention. Serial creatine kinase and ECG monitoring revealed no significant changes after the procedure compared with baseline.

Clinical and Angiographic Outcome at Follow-up
During the follow-up period of 178±17 days (range, 150 to 225 days), at least one clinical event occurred in 5 of the 15 patients (Table 2Down). Angiographic restenosis (Table 2Down and Fig 3Down) occurred in 6 patients (40%; 95% confidence interval, 16% to 68%). The minimal luminal diameter, reference vessel diameter, and percent diameter stenosis were 0.9±0.4 mm, 2.8±0.5 mm, and 68±12% at baseline; 2.5±0.6 mm, 2.7±0.5 mm, and 11±8% just after the procedure; and 1.7±0.9 mm, 2.7±0.7 mm, and 39±25% at 6-month follow-up, respectively. In 4 patients with restenosis, repeat PTCA of the lesion treated with ß-irradiation was performed. All PTCA procedures for restenosis performed in the irradiated arterial segments were uncomplicated and lead to good angiographic results. Further stenting was necessary in one patient (patient 3) for marked elastic recoil. This patient developed recurrent symptoms 2 months after the second procedure, with evidence of myocardial ischemia in the territory of the culprit left anterior descending coronary artery, and underwent elective bypass surgery. Two other patients with angiographic restenosis were not further revascularized: patient 14 because he remained asymptomatic with a negative stress test despite a 55% restenosis, and patient 10 because control angiography showed total occlusion at the previously treated site with well developed collaterals to the distal vessel. In the latter patient, radiotherapy had been combined with angioplasty for recurrent within-stent restenosis, and recurrent angina was treated by increasing medical treatment.


View this table:
[in this window]
[in a new window]
 
Table 2. Clinical Outcome



View larger version (21K):
[in this window]
[in a new window]
 
Figure 3. Evolution of target lesion percent diameter stenosis in the 15 patients.

In patients 13 and 15, disease progression was noted in another artery and was treated by further angioplasty. In patient 15, in whom the PTCA/irradiation procedure had been performed in the right coronary artery (Fig 3Up) and showed no restenosis at 5 months, PTCA of a new tight lesion of the proximal LAD was complicated by transmural anterior myocardial infarction 5 days after hospital discharge. Thrombolytic therapy was used but lead to fatal intracerebral hemorrhage.

In no case was the development of an aneurysm or angiographically detectable thrombus in the irradiated arterial segment observed at follow-up.

It is noteworthy that among 5 patients with stents (patients 2, 3, 4, and 13, stents were implanted during PTCA/irradiation procedure; patient 10, within-stent restenosis), three angiographic restenoses (in patients 3, 10, and 13) were observed. The three remaining restenoses (in patients 9, 12, and 14) occurred in 10 patients without stent implantation.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
With the aim of reducing the development of atherosclerosis, the first in vivo use of intravascular radiotherapy was reported 32 years ago by Friedman et al.16 The concept was more recently revived by Liermann et al11 to modulate the postangioplasty restenotic process, and a number of studies have documented the favorable impact of intraluminal {gamma}-irradiation on the occurrence of neointimal hyperplasia in several animal models.8 9 17 18 Liermann et al11 12 used a 192Ir source for irradiation of femoropopliteal arterial segments after stent implantation. The use of a {gamma} source made it necessary to transport patients from the catheterization laboratory to a shielded afterloading room before radiation treatment. A dose of 12 Gy was prescribed at a distance of 3 mm from the source, but no centering was used. Follow-up periods of <=69 months in 29 patients suggest a favorable impact on restenosis and show excellent clinical tolerance, with no vascular or perivascular side effects.19 Condado et al20 were the first to report the use of intracoronary {gamma}-irradiation; they also used a 192Ir source. A dose of either 20 or 25 Gy was prescribed, and no acute complications were noted. Teirstein et al21 are also evaluating in a clinical setting the use of 192Ir after stenting in coronary arteries. The source is noncentered, and its relatively low activity makes it possible to administer radiotherapy in the catheterization laboratory.

Intravascular ß-Irradiation
To the best of our knowledge, the present series represents the first report on the clinical use of endovascular ß-irradiation. In a similar manner to {gamma} sources, endovascular ß-irradiation is also remarkably effective in different animal models to prevent fibrointimal proliferation in response to vessel injury.15 17 The use of ß sources has several advantages over {gamma}-irradiation: (1) lower undue irradiation of surrounding periarterial structures, due to a steeper depth-dose fall-off curve; (2) less radioprotection problems, making it compatible with a conventional catheterization laboratory; and (3) ability to deliver a high focal dose over a short period of time.

The present series demonstrates feasibility and lack of medium-term toxicity of an 18-Gy dose of ß-irradiation delivered to the balloon/artery interface. Our technical success was 100%, and we encountered no particular difficulty in reaching the lesion or delivering the planned radiation treatment. Because our centering balloon is occlusive in the coronary lumen once inflated and because the activity of the 90Y sources that were used was fairly low in this initial series, it was necessary for 4 of the 15 patients to be treated with two or three fractionated doses, with intermittent balloon deflations and source retrieval, while ischemia was allowed to subside temporarily. When sources with higher activity are available, this should no longer present any difficulty. Because of the steep depth-dose fall-off curve, the time necessary to administer the planned 18-Gy dose was greatly influenced by the diameter of the centering balloon (mean exposure time, 281±50 seconds for 2.5-mm, 322±209 seconds for 3-mm, and 561±191 seconds for 3.5-mm-diameter centering balloons). The dose fall-off also makes it important to center the source within the vascular lumen, and such centering is a distinguishing feature of our approach compared with other systems.11 17 20 21 Centering of the source is intended to homogenize the radiation dose delivered to different points of the arterial wall within the treated segment. In the case of atherosclerotic human coronary arteries, the target smooth muscle cells are situated within a thin-walled (0.3 to 2 mm thick) tubular structure.22 23 Endoluminal inflation of the centering balloon forces the target tissues to occupy a position as equidistant as possible in respect to the radiation source, thereby allowing good circumferential and axial dose distribution. The increased distance between source and arterial wall induced by balloon inflation can be compensated for by an appropriately calculated exposure time. It is obvious that an eccentric intraluminal position of the source would result in areas of both relative underdosage and overdosage with respect to the prescribed dose level.10 12 This could be clinically relevant because it has been suggested that low radiation doses (4 to 8 Gy) may stimulate rather than inhibit neointimal proliferation,24 whereas higher doses (>=30 Gy) could lead to late vascular complications.25 26 Obviously, our centering balloon cannot take into account any degree of eccentricity of the lumen itself within the atherosclerotic vessel; it will ensure, however, that no section of the arterial wall is exposed to toxic doses of radiation because the minimal distance between source and inner arterial surface is determined by the radius of the inflated balloon. The prescribed dose to the vessel wall is a maximal dose that cannot be exceeded.

Safety
In keeping with our data from experiments with animals15 and those of others,9 this early clinical experience suggests no evidence of clinical or angiographically detectable toxicity of ß-brachytherapy after a follow-up period of 6 months. We specifically noted no angiographic appearance suggestive of aneurysm formation and no intraluminal filling defect suggesting thrombus deposition. One patient (patient 10) did develop late target segment occlusion without myocardial infarction or resting ECG changes, but this occurrence was fairly nonspecific because at the time of the radiotherapeutic procedure, the patient was being treated for the third time at the same site after within-stent restenosis. One patient died (patient 15), but this occurred after treatment for a new unstable coronary lesion in another vessel and was clearly unrelated to the radiation treatment. Condado et al27 reported the occurrence of a single coronary aneurysm at follow-up after intracoronary {gamma}-irradiation. It should be noted, however, that the prescribed dose was 20 to 25 Gy and that no centering device was used. Liermann et al11 19 observed no vascular or perivascular lesions that could be attributed to intravascular radiotherapy during follow-up periods of <=69 months. However, radiation-induced arteriopathy is a well recognized complication of external radiation therapy. It is usually a late complication, occurring after a mean of 16 years (range, 3 to 29 years) after treatment of a large field.28 It is generally accepted that after mediastinal irradiation in cancer patients, the risk of the development of significant epicardial coronary artery disease is increased in comparison with the normal population.29 In addition, the experimental data of Gillette et al26 show that intraoperative radiation therapy with single doses of >30 Gy to a large field are capable of inducing late vascular lesions. Although it remains uncertain whether any parallel should be made between large-field radiotherapy to healthy arteries and the very local irradiation of a barotraumatized atheromatous vessel segment, it will be necessary to carefully evaluate the late impact of intravascular radiotherapy with the use of prolonged follow-up periods before definitive conclusions can be made regarding the safety of intraluminal ß-irradiation. Radiation treatment delivered to non-oncological patients also raises the concern of radiation-induced carcinogenesis, but because ß-irradiation delivers an extremely low dose beyond the immediate target lesion and because the exposed tissues (eg, arteries, veins, cardiac muscle, pericardium) have a low spontaneous carcinogenicity rate, this risk appears to be extremely low.

Study Limitations
The present study demonstrates excellent technical feasibility but was not designed to evaluate the efficacy of intracoronary ß-brachytherapy. Six of the 15 patients developed angiographic restenosis, using the predefined criterion of a 50% diameter stenosis by quantitative coronary angiography. Although the confidence interval is wide due to the small number of patients studied, the observed restenosis rate does not suggest a major impact of an 18-Gy dose on the restenotic process. Despite limitations inherent to a pilot study involving a heterogeneous group of only 15 patients, it may be important to note that 5 of the 6 patients with restenosis at 6 months had only a moderate degree of narrowing: {approx}50% to 60% range (Fig 3Up). This could be interpreted as suggesting a favorable but insufficient impact of the chosen dose.

Not only is the optimal dose still undefined, but so is the target. Recent work by several groups30 31 suggests that the adventitia may play an important role in the genesis of vascular remodeling after angioplasty. It is also possible that the adventitia may serve as a source of myofibroblasts that subsequently migrate within the media before replication.30

The dose of 18 Gy was chosen on the basis of our work with animals15 and is broadly comparable to that prescribed by other groups, both clinically and in animal models. The irradiation delivery system we used in this study provides a good reproducible circumferential and axial dose distribution at the surface of the centering balloon inflated to a standard pressure of 5 bar,14 However, the dose fall-off as a function of arterial wall thickness remains important. For 90Y, the intramural dose gradient consists of a >50% decrease for each millimeter of arterial tissue depth. Thus, the delivery of an 18-Gy radiation dose at the centering balloon/arterial surface interface results in a dose of {approx}8 Gy at 1 mm and <4 Gy at 2 mm of arterial wall depth. This dose gradient may not be relevant in rabbit arteries that do not exceed 0.4 mm in thickness (V. Verin, MD, unpublished observations) but could be critical for clinical use. Taking into account that coronary arterial wall thickness in patients varies between 0.3 and 2 mm,22 23 our chosen dose of 18 Gy could have lead to insufficient inhibition and even to stimulation of smooth muscle cells situated in the external wall layers of atherosclerotic coronary arteries. This could be corrected for by increasing the centering balloon/arterial surface interface dose. Clearly, a clinical dose-finding evaluation is necessary before a controlled randomized efficacy trial can be appropriately designed.

We know from our data15 and those of others8 9 10 17 that intraluminal radiotherapy is a powerful inhibitor of fibrointimal proliferation. It is, however, also plausible that it would be capable of favorably influencing constrictive arterial remodeling after PTCA by diminishing the contraction force of the healing arterial wall. The evaluation of radiation effect on surgical wound contraction32 33 demonstrates a significant reduction in wound strength after irradiation. A single dose of 18 Gy before wound infliction reduces wound strength by 50% to 65% compared with control within 3 months of follow-up.32

Conclusions
The present data demonstrate the clinical feasibility of intracoronary ß-brachytherapy and fail to reveal any complications that could be attributed to its use. Definitive conclusions regarding safety will have to await longer-term evaluation. Proof of efficacy will require strict dose-finding evaluation of higher doses than those used in the present pilot study followed by a controlled, randomized trial using both clinical and angiographic end points.

Received July 29, 1996; revision received October 10, 1996; accepted October 27, 1996.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 
1. Gruentzig AR, King SB III, Schlumpf M, Siegenthaler W. Long-term follow-up after percutaneous transluminal coronary angioplasty. N Engl J Med. 1987;316:1127-1132.[Abstract]

2. Nobuyoshi M, Kimura T, Nosaka H, Mioka S, Ueno K, Yokoi H, Hamasaki N, Horiuchi H, Ohishi H. Restenosis after successful percutaneous transluminal coronary angioplasty: serial angiographic follow-up of 229 patients. J Am Coll Cardiol. 1988;12:616-623.[Abstract]

3. Urban P, Buller N, Fox K, Shapiro L, Bayliss J, Rickards A. Lack of effect of warfarin on the restenosis rate or on clinical outcome after balloon coronary angioplasty. Br Heart J. 1988;60:485-488.[Abstract/Free Full Text]

4. MERCATOR Study Group. Does the new angiotensin converting enzyme inhibitor cilazapril prevent restenosis after percutaneous transluminal coronary angioplasty? Results of the MERCATOR Study: a multicenter, randomized, double-blind placebo-controlled trial. Circulation. 1992;86:100-110.[Abstract/Free Full Text]

5. Muller DWM, Ellis SG, Topol EJ. Colchicine and antineoplastic therapy for prevention of restenosis after percutaneous coronary interventions. J Am Coll Cardiol. 1991;17:26B-31B.

6. Fischman DL, Leon MB, Baim DS, Schatz RA, Savage MP, Penn I, Detre K, Veltri L, Ricci D, Nobuyoshi M, Cleman M, Heuser R, Almond D, Teirstein P, Fish RD, Colombo A, Brinker J, Moses J, Shaknovich A, Hirshfeld J, Bailey S, Ellis S, Rake R, Goldberg S. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med. 1994;331:496-501.[Abstract/Free Full Text]

7. Serruys P, de Jaegere P, Kiemeneij F, Macaya C, Rutsch W, Heyndrickx G, Emanuelsson H, Marco J, Legrand V, Materne P, Belardi J, Sigwart U, Colombo A, Goy JJ, van den Heuvel P, Delcan J, Morel MA, for the BENESTENT Study Group. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med. 1994;331:489-495.[Abstract/Free Full Text]

8. Wiedermann JG, Marboe C, Amols H, Schwartz A, Weinberger J. Intracoronary irradiation markedly reduces restenosis after balloon angioplasty in a porcine model. J Am Coll Cardiol. 1994;23:1491-1498.[Abstract]

9. Wiedermann JG, Marboe C, Amols H, Schwartz A, Weinberger J. Intracoronary irradiation markedly reduces neointimal proliferation after balloon angioplasty in swine: persistent benefit at 6-month follow-up. J Am Coll Cardiol. 1995;25:1451-1456.[Abstract]

10. Waksman R, Robinson KA, Crocker IR, Gravanis MB, Cipolla GD, King SB III. Endovascular low-dose irradiation inhibits neointima formation after coronary artery balloon injury in swine. Circulation. 1995;91:1533-1539.[Abstract/Free Full Text]

11. Liermann D, Bottcher HD, Kollath J, Schopohl B, Strassmann G, Strecker EP, Breddin KH. Prophylactic endovascular radiotherapy to prevent intimal hyperplasia after stent implantation in femoropopliteal arteries. Cardiovasc Intervent Radiol. 1994;17:12-16.[Medline] [Order article via Infotrieve]

12. Bottcher HD, Schopohl B, Liermann D, Kollath TJ, Adamietz IA. Endovascular irradiation: a new method to avoid recurrent stenosis after stent implantation in peripheral arteries: technique and preliminary results. Int J Radiat Oncol Biol Phys. 1994;29:183-186.[Medline] [Order article via Infotrieve]

13. Popowski Y, Verin V, Papirov I, Nouet P, Rouzaud M, Grob E, Schwager M, Urban P, Rutishauser W, Kurtz J. High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angioplasty: preliminary dosimetric tests of a new source presentation. Int J Radiat Oncol Biol Phys. 1995;33:211-215.[Medline] [Order article via Infotrieve]

14. Popowski Y, Verin V, Papirov I, Nouet P, Rouzaud M, Grob E, Schwager M, Urban P, Rutishauser W, Kurtz J. Intra-arterial 90-yttrium brachytherapy: preliminary dosimetric study using a specially modified angioplasty balloon. Int J Radiat Oncol Biol Phys. 1995;33:713-717.[Medline] [Order article via Infotrieve]

15. Verin V, Popowski Y, Urban P, Belenger J, Redard M, Costa M, Widmer M-C, Rouzaud M, Nouet P, Grob E, Schwager M, Kurtz JM, Rutishauser W. Intra-arterial ß-irradiation prevents neointimal hyperplasia in a hypercholesterolemic rabbit restenosis model. Circulation. 1995;92:2284-2290.[Abstract/Free Full Text]

16. Friedman M, Felton L, Byers S. The antiatherogenic effect of iridium192 upon the cholesterol-fed rabbit. J Clin Invest. 1964;43:185-192.

17. Waksman R, Robinson KA, Crocker IR, Wang C, Gravanis MB, Cipolla GD, Hillstead RA, King SB III. Intracoronary low-dose ß-irradiation inhibits neointima formation after coronary artery balloon injury in the swine restenosis model. Circulation. 1995;92:3025-3031.[Abstract/Free Full Text]

18. Mazur W, Ali MN, Dabaghi SF, Crinstead C, Abukhalil J, Paradise P, DeFelice CA, Schulz D, Berner BM, Fajardo LF, French BA, Raizner AE. High dose rate intracoronary radiation suppresses neointimal proliferation in the stented and ballooned model of porcine restenosis. Circulation. 1994;90(suppl I):I-652. Abstract.

19. Schopohl B, Juling-Pohlit L, Bottcher HD, Liermann D, Kollath J, Rahl CG, Manegold KH, Ramm U. Endovascular irradiation for avoidance of recurrent stenosis after stent implantation in peripheral arteries: 5 years follow-up. In: Discoveries in Radiation for Restenosis. Atlanta, Ga: Emory University School of Medicine, 1996:89-92.

20. Condado JA, Gurdiel O, Espinoza R, Gonzales Brito J, Harrison ML, Loyner LR, Liprie SF. Percutaneous transluminal coronary angioplasty and intracoronary radiation therapy: a possible new modality for the treatment of coronary restenosis: a preliminary report of the first 10 patients treated with intracoronary radiation therapy. J Am Coll Cardiol. 1995;Feb(suppl):288A. Abstract.

21. Teirstein PS, Massullo V, Jani S, Russo RJ, Schatz RA, Steuterman S, Morris NB, Tripuraneni P. Catheter-based radiation therapy to inhibit restenosis following coronary stenting. Circulation. 1995;92(suppl I):I-543. Abstract.

22. McPherson DD, Armstrong M, Rose E, Kieso RA, Megan M, Hunt M, Hite P, Marcus ML, Kerber RE. High frequency epicardial echocardiography for coronary artery evaluation: in vitro and in vivo validation of arterial lumen and wall thickness measurements. J Am Coll Cardiol. 1986;8:600-606.[Abstract]

23. McPherson DD, Johnson MR, Alvarez NM, Rewcastle NB, Collins SM, Armstrong ML, Kieso RA, Thorpe LJ, Marcus ML, Kerber RE. Variable morphology of coronary atherosclerosis: characterization of atherosclerotic plaque and residual arterial lumen size and shape by epicardial echocardiography. J Am Coll Cardiol. 1992;19:593-599.[Abstract]

24. Schwartz RS, Koval TM, Edwards WD, Camrud AR, Bailey KR, Browne K, Vlietstra RE, Holmes DR. Effect of external beam irradiation on neointimal hyperplasia after experimental coronary artery injury. J Am Coll Cardiol. 1992;19:1106-1113.[Abstract]

25. Gillette EL, Powers BE, McChesney SL, Withrow SJ. Aortic wall injury following intraoperative irradiation. Int J Radiat Oncol Biol Phys. 1988;15:1401-1406.[Medline] [Order article via Infotrieve]

26. Gillette EL, Powers BE, McChesnay SL, Park RD, Withrow SJ. Response of aorta and branch arteries to experimental intraoperative irradiation. Int J Radiat Oncol Biol Phys. 1989;17:1247-1255.[Medline] [Order article via Infotrieve]

27. Condado JA, Gurdiel O, Espinoza R, Brito JG, Burger B, Villoria G, Acquatella H, Liprie SF. Late follow-up after percutaneous transluminal coronary angioplasty and intracoronary radiation therapy. In: Discoveries in Radiation for Restenosis. Atlanta, Ga: Emory University School of Medicine, 1996:105.

28. Benoff LJ, Schweitzer P. Radiation therapy induced cardiac injury. Am Heart J. 1995;129:1193-1196.[Medline] [Order article via Infotrieve]

29. Stewart JR FL Gillette SM, Constine LS. Radiation injury to the heart. Int J Radiat Oncol Biol Phys. 1995;31:1205-1211.[Medline] [Order article via Infotrieve]

30. Shi Y, Pieniek M, Fard A, O'Brien J, Mannion JD, Zalewski A. Adventitial remodeling after coronary arterial injury. Circulation. 1996;93:340-348.[Abstract/Free Full Text]

31. Andersen HR, Maeng M, Thorwest M, Falk E. Remodeling rather than neointimal formation explains luminal narrowing after deep vessel wall injury. Circulation. 1996;93:1716-1724.[Abstract/Free Full Text]

32. Gorodetsky R, McBride WH, Withers HR. Assay of radiation effects in mouse skin as expressed in wound healing. Radiat Res. 1988;116:135-144.[Medline] [Order article via Infotrieve]

33. Vegesna V, Withers HR, Holly FE, McBride WH. The effect of local and systemic irradiation on impairment of wound healing in mice. Radiat Res. 1993;135:431-433.[Medline] [Order article via Infotrieve]




This article has been cited by other articles:


Home page
Eur Heart JHome page
P. Urban, P. Serruys, D. Baumgart, A. Colombo, S. Silber, E. Eeckhout, A. Gershlick, K. Wegscheider, L. Verhees, R. Bonan, et al.
A multicentre European registry of intraluminal coronary beta brachytherapy
Eur. Heart J., April 1, 2003; 24(7): 604 - 612.
[Abstract] [Full Text] [PDF]


Home page
J CARDIOVASC PHARMACOL THERHome page
S. Sharma, B. Bhambi, W. Nyitray, K. Desai, D. L. Davis, G. Sharma, P. Shukla, C. File, and T. Ishimori
Bivalirudin (Angiomax) Use during Intracoronary Brachytherapy May Predispose to Acute Closure
Journal of Cardiovascular Pharmacology and Therapeutics, March 1, 2003; 8(1): 9 - 15.
[Abstract] [PDF]


Home page
Eur Heart JHome page
P.W. Serruys, G. Sianos, W. van der Giessen, H.J.R.M. Bonnier, P. Urban, W. Wijns, E. Benit, M. Vandormael, R. Dorr, C. Disco, et al.
Intracoronary {beta}-radiation to reduce restenosis after balloon angioplasty and stenting. The Beta Radiation In Europe (BRIE) study
Eur. Heart J., September 1, 2002; 23(17): 1351 - 1359.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
E. Regar, K. Kozuma, G. Sianos, V.L.M.A. Coen, W.J. van der Giessen, D. Foley, P. de Feyter, B. Rensing, P. Smits, J. Vos, et al.
Routine intracoronary beta-irradiation. Acute and one year outcome in patients at high risk for recurrence of stenosis
Eur. Heart J., July 1, 2002; 23(13): 1038 - 1044.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. O. Williams
Intracoronary Brachytherapy: Past, Present, and Future
Circulation, June 11, 2002; 105(23): 2699 - 2700.
[Full Text] [PDF]


Home page
CirculationHome page
M. A. Grise, V. Massullo, S. Jani, J. J. Popma, R. J. Russo, R. A. Schatz, E. M. Guarneri, S. Steuterman, D. A. Cloutier, M. B. Leon, et al.
Five-Year Clinical Follow-Up After Intracoronary Radiation: Results of a Randomized Clinical Trial
Circulation, June 11, 2002; 105(23): 2737 - 2740.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
K. Kozuma, M.A. Costa, W.J. van der Giessen, M. Sabate, J.M.R. Ligthart, V.L.M.A. Coen, I.P. Kay, A.J. Wardeh, A.H.M. Knook, P.J de Feyter, et al.
Initial observation regarding changes in vessel dimensions after balloon angioplasty and stenting followed by catheter-based {beta}-radiation. Is stenting necessary in the setting of catheter-based radiotherapy?
Eur. Heart J., April 2, 2002; 23(8): 641 - 649.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Wexberg, C. Kirisits, M. Gyongyosi, M. Gottsauner-Wolf, M. Ploner, B. Pokrajac, R. Potter, and D. Glogar
Vascular morphometric changes after radioactivestent implantation: a dose-response analysis
J. Am. Coll. Cardiol., February 6, 2002; 39(3): 400 - 407.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. S. Teirstein and R. E. Kuntz
New Frontiers in Interventional Cardiology: Intravascular Radiation to Prevent Restenosis
Circulation, November 20, 2001; 104(21): 2620 - 2626.
[Full Text] [PDF]


Home page
Eur Heart JHome page
M.Y Salame, S Verheye, I.R Crocker, N.A.F Chronos, K.A Robinson, and S.B King III
Intracoronary radiation therapy
Eur. Heart J., April 2, 2001; 22(8): 629 - 647.
[PDF]


Home page
NEJMHome page
V. Verin, Y. Popowski, B. de Bruyne, D. Baumgart, W. Sauerwein, M. Lins, G. Kovacs, M. Thomas, F. Calman, C. Disco, et al.
Endoluminal Beta-Radiation Therapy for the Prevention of Coronary Restenosis after Balloon Angioplasty
N. Engl. J. Med., January 25, 2001; 344(4): 243 - 249.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
K Kozuma, M.A Costa, M Sabate, C.J Slager, E Boersma, I.P Kay, J.P.A Marijnissen, S.G Carlier, J.J Wentzel, A Thury, et al.
Relationship between tensile stress and plaque growth after balloon angioplasty treated with and without intracoronary beta-brachytherapy
Eur. Heart J., December 2, 2000; 21(24): 2063 - 2070.
[Abstract] [PDF]


Home page
CirculationHome page
M. Hoher, J. Wohrle, M. Wohlfrom, H. Hanke, R. Voisard, H. H. Osterhues, M. Kochs, S. N. Reske, V. Hombach, and J. Kotzerke
Intracoronary {beta}-Irradiation With a Liquid 188Re-Filled Balloon : Six-Month Results From a Clinical Safety and Feasibility Study
Circulation, May 23, 2000; 101(20): 2355 - 2360.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. E. Kuntz and D. S. Baim
Prevention of Coronary Restenosis : The Evolving Evidence Base for Radiation Therapy
Circulation, May 9, 2000; 101(18): 2130 - 2133.
[Full Text] [PDF]


Home page
CirculationHome page
R. Waksman, B. Bhargava, L. White, R. C. Chan, R. Mehran, A. J. Lansky, G. S. Mintz, L. F. Satler, A. D. Pichard, M. B. Leon, et al.
Intracoronary {beta}-Radiation Therapy Inhibits Recurrence of In-Stent Restenosis
Circulation, April 25, 2000; 101(16): 1895 - 1898.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. Schulz, C. Niederer, C. Andres, R. A. Herrmann, X. Lin, R. Henkelmann, W. Panzer, C. Herrmann, D. F. Regulla, I. Wolf, et al.
Endovascular Irradiation From {beta}-Particle-Emitting Gold Stents Results in Increased Neointima Formation in a Porcine Restenosis Model
Circulation, April 25, 2000; 101(16): 1970 - 1975.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Y. Salame, S. Verheye, S. P. Mulkey, N. A. F. Chronos, S. B. King III, I. R. Crocker, and K. A. Robinson
The Effect of Endovascular Irradiation on Platelet Recruitment at Sites of Balloon Angioplasty in Pig Coronary Arteries
Circulation, March 14, 2000; 101(10): 1087 - 1090.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. J. Connors III, D. Seidenwurm, J. C. Wojak, R. W. Hurst, M. E. Jensen, R. Wallace, T. Tomsick, J. Barr, C. Kerber, E. Russell, et al.
Treatment of Atherosclerotic Disease at the Cervical Carotid Bifurcation: Current Status and Review of the Literature
AJNR Am. J. Neuroradiol., March 1, 2000; 21(3): 444 - 450.
[Full Text]


Home page
Cardiovasc ResHome page
M. P Jenkins, G. A Buonaccorsi, R. Mansfield, C. C.R Bishop, S. G Bown, and J. R McEwan
Reduction in the response to coronary and iliac artery injury with photodynamic therapy using 5-aminolaevulinic acid
Cardiovasc Res, January 14, 2000; 45(2): 478 - 485.
[Abstract] [Full Text] [PDF]


Home page
Vasc MedHome page
D. P Lee, S. Lo, K. Forster, A. C Yeung, and S. N Oesterle
Clinical applications of brachytherapy for the prevention of restenosis
Vascular Medicine, November 1, 1999; 4(4): 257 - 268.
[Abstract] [PDF]


Home page
CirculationHome page
R. Waksman
Late Thrombosis After Radiation : Sitting on a Time Bomb
Circulation, August 24, 1999; 100(8): 780 - 782.
[Full Text] [PDF]


Home page
CirculationHome page
J. Fareh, R. Martel, P. Kermani, and G. Leclerc
Cellular Effects of ß-Particle Delivery on Vascular Smooth Muscle Cells and Endothelial Cells : A Dose-Response Study
Circulation, March 23, 1999; 99(11): 1477 - 1484.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. B. King III
Radiation for Restenosis : Watchful Waiting
Circulation, January 19, 1999; 99(2): 192 - 194.
[Full Text] [PDF]


Home page
CirculationHome page
S. B. King, D. O. Williams, P. Chougule, J. L. Klein, R. Waksman, R. Hilstead, J. Macdonald, K. Anderberg, and I. R. Crocker
Endovascular ß-Radiation to Reduce Restenosis After Coronary Balloon Angioplasty : Results of the Beta Energy Restenosis Trial (BERT)
Circulation, May 26, 1998; 97(20): 2025 - 2030.
[Abstract] [Full Text] [PDF]


Home page
Journal Watch CardiologyHome page
Radiation for Restenosis
Journal Watch Cardiology, March 25, 1997; 1997(325): 12 - 12.
[Full Text]


Home page
CirculationHome page
P. Teirstein
ß-Radiation to Reduce Restenosis: Too Little, Too Soon?
Circulation, March 4, 1997; 95(5): 1095 - 1097.
[Full Text]


This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Verin, V.
Right arrow Articles by Rutishauser, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Verin, V.
Right arrow Articles by Rutishauser, W.