Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1996;94:1578-1584

This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dupuis, J.
Right arrow Articles by Gosselin, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dupuis, J.
Right arrow Articles by Gosselin, G.

(Circulation. 1996;94:1578-1584.)
© 1996 American Heart Association, Inc.


Articles

Human Pulmonary Circulation Is an Important Site for Both Clearance and Production of Endothelin-1

Jocelyn Dupuis, MD; Duncan J. Stewart, MD; Peter Cernacek, MD; Gilbert Gosselin, MD

the Department of Medicine, Montreal Heart Institute, St. Michael's Hospital, Toronto, and the Royal Victoria Hospital, Montreal, Canada.

Correspondence to Jocelyn Dupuis, MD, Montreal Heart Institute, 5000 Belanger St, Montreal, Quebec H1T 1C8, Canada.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background Animal studies suggest a major role of the pulmonary circulation in the clearance of circulating endothelin-1 (ET-1). The contribution of the human pulmonary circulation to plasma ET-1 clearance, however, has never been quantified. The absence of an AV gradient in plasma ET-1 has previously been interpreted as evidence that the lungs do not have a role in modulating circulating ET-1 levels. This study was designed to quantify and discern between pulmonary ET-1 clearance and production in humans.

Methods and Results We studied 13 subjects by combining the multiple indicator-dilution technique with the measurement of immunoreactive ET-1 (irET-1). All patients had normal left ventricular ejection fractions (61±7%, mean±SD) and baseline hemodynamics. Mean pulmonary ET-1 extraction was 47±7%. The ET-1 extracted does not return to circulation and can be characterized by a sequestration rate constant: Kseq=0.048±0.019 s-1. There was no significant difference between irET-1 levels from the pulmonary artery and aorta (0.61±0.29 and 0.68±0.33 pg/mL, respectively; P=.22); the normal lung consequently produces an amount of ET-1 that is quantitatively similar to the amount that has been extracted.

Conclusions The human lung is an important site for both clearance and production of ET-1. There is a normal physiological balance of ET-1 across the pulmonary circulation, which explains the absence of difference in AV ET-1 levels despite a 47±7% clearance. Reduced pulmonary clearance or increased production of this peptide may contribute to the increase in circulating levels found in various cardiovascular conditions.


Key Words: endothelin • circulation • metabolism • endothelium


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Endothelin-1 (ET-1) is a 21–amino-acid peptide with potent vasoconstrictive and proliferative actions on the vascular smooth muscle and other cells.1 The vascular endothelium produces ET-1 in a preferential paracrine fashion with a smaller clinically measurable luminal secretion.2 Numerous animal studies suggest that the lungs are a major site for ET-1 clearance3 4 5 6 7 8 9 and production10 11 and that they may modulate circulating ET-1 levels. The role of the human pulmonary circulation in the clearance and production of circulating ET-1, however, has never been established. In the normal human, there is no significant difference between immunoreactive ET-1 (irET-1) levels across the pulmonary circulation12 13 ; a simple analysis of this observation would be that the human lung is metabolically inactive toward ET-1 and does not modify circulating ET-1 levels. A more complex "black box" hypothesis would be that there is a metabolic balance for ET-1 across the human pulmonary circulation; the human lung may be an important site for ET-1 clearance but with a simultaneous equal release into circulation that explains the observed absence of an AV gradient in ET-1 levels. Such a balance is present in dogs with a mean pulmonary ET-1 clearance of 31±8% and a simultaneous quantitatively similar release3 (there also is no AV ET-1 gradient across dog lungs).

Circulating ET-1 levels are increased in conditions of primary or secondary pulmonary hypertension14 15 16 17 and may be a marker or mediator of disease.18 In heart failure, the ET-1 levels are linearly related to the severity of pulmonary hypertension.19 20 Some patients with pulmonary hypertension also have a positive ET-1 gradient across the lungs14 15 21 ; the immunoreactive levels in the systemic circulation are slightly higher than in the mixed venous blood. The human pulmonary circulation may thus modulate circulating ET-1 by maintaining a normal physiological balance and contribute to the pathological hyperendothelinemia by an increased production, a reduced clearance, or a combination of both.

The importance of the human pulmonary circulation in the clearance or production of ET-1, however, is still unknown. We designed a set of experiments to quantify and discern between pulmonary clearance and production of ET-1 in humans without pulmonary hypertension. Combination of the multiple indicator-dilution technique and simultaneous measurements of irET-1 levels across the lungs enables dissection of the black-box elements and was used for this purpose.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Study protocol and the consent form were designed in accordance with the research and ethics committees of the Montreal Heart Institute. Thirteen subjects were recruited among patients awaiting elective diagnostic coronary angiograms for diagnosed or suspected stable angina pectoris. Criteria for exclusion were history of heart failure, previous myocardial infarction, pulmonary hypertension, diabetes, and renal failure with a creatinine level >=200 mmol/L.

The study protocol was carried out before the coronary angiogram and left ventriculogram. The right femoral artery and vein were punctured by use of the Seldinger technique, and introducers were inserted. A pigtail catheter was positioned about 2 cm above the aortic valve, and a multipurpose catheter was positioned in the right ventricular outflow tract just below the pulmonary valve. Companion aortic and mixed venous blood samples were simultaneously obtained in EDTA-containing tubes for determination of irET-1 levels. A 2-cm extension with a three-way stopcock was added to the venous catheter, and a 2-mL bolus mixture for the indicator-dilution study was introduced into the catheters (the bolus consequently was completely contained within the injection system). The arterial catheter was then connected to a Masterflex Roller pump that was connected to a circular fraction collector. The dilution experiment was carried out by rapid flushing of the bolus with 10 mL of the patient's and with simultaneous collection of aortic blood in 50 consecutive tubes (0.6 seconds per tube) at 200 mL/min. The angiographic procedure was then performed as scheduled. A 3-mL blood sample was taken from the injection lines to determine the amount of activity retained in the injection system.

Injection Mixture Preparation
The preparation was carried out under sterile conditions. Human albumin (25%) was added to 3 mL Evans blue dye to obtain a final bolus concentration of 4% of albumin. The blue dye binds tightly to albumin, so this procedure results in labeling of albumin, the concentration of which can be determined later spectrophotometrically. 125I-labeled ET-1 (10 µCi; Du Pont–New England Nuclear; specific activity, 2200 Ci/mmol) was then added to the mixture. The final volume was {approx}3.5 mL per experiment: 2 mL was taken to be used as the injection mixture, and the remaining 1.5 mL was kept for the preparation of dilution curve standards.

Sample Processing
All collected tubes, 1/10- and 1/100-diluted standards, and injection line samples were treated identically. Blood (200 µL) was pipetted from each tube and assayed in a gamma counter to determine 125I activity. The remaining samples were centrifuged at 3000 rpm for 10 minutes, and 100 µL plasma was pipetted and added to 1.0 mL of 0.9% NaCl in a spectrophotometer cuvette. Evans blue dye absorbance was determined as the difference between the absorbance at 620 and 740 nm.

Indicator-Dilution Curve Construction and Analysis
The activity of tracer ET-1 and tracer albumin for each tube was corrected for background activity. The exact quantity of tracer injected was determined by subtracting the activity retained in the injection system from the amount contained in 2 mL injection mixture. For each sample, the fractional recovery of tracer ET-1 and albumin could then be determined. A plot of the fractional recoveries per 1 mL blood as a function of time was then constructed to obtain the indicator-dilution curve for each tracer. The albumin was used as a plasmatic vascular reference tracer; it remains in the vascular space within a pulmonary transit time. A plasmatic tracer that is cleared from the pulmonary circulation will exhibit an outflow profile that deviates from that of albumin; its fractional recovery per 1 mL blood at each time point will be lower than that of albumin. This technique has been used extensively to quantify microcirculatory events in the pulmonary circulation in vivo. It helped characterization of the pulmonary hydrolysis of ACE substrates,22 clearance of vasoactive amines like serotonin and norepinephrine,23 and more recently pulmonary clearance of ET-1 in dogs.3

The pulmonary blood flow was computed with the following formula:

where qo is the total amount of Evans blue dye–labeled albumin injected. The integral in the denominator represents the area under the extrapolated fractional recovery versus time curve for tracer albumin. The downslope of indicator-dilution curves is characteristically semiexponential, so its terminal portion can easily be linearly extrapolated on a logarithmic scale to remove any parasite recirculation of the tracers.

The pulmonary mean transit time (MTT) for each tracer is then calculated as

where C is the tracer outflow fractional recovery and cath is the mean transit time of the collection system. This computed transit time includes the pulmonary large vessels and microcirculatory transit time plus the transit time of the left chambers of the heart.

Instantaneous tracer ET-1 extraction (EXT[t]) for each time point is calculated with the following:

Cumulative tracer ET-1 extraction for each curve is obtained by

where the numerator and denominator are the areas under the extrapolated fractional recovery versus time curve for tracer ET-1 and albumin, respectively. Mean tracer ET-1 extraction represents the difference between the area of these two curves.

From the outflow profile relationship of the two tracers, we can also estimate the sequestration rate constant for pulmonary ET-1 clearance (Kseq). We have previously discussed the significance of Kseq in terms of ordinary capillary modeling.3 It represents the product of capillary permeability to endothelin and the surface-to-volume ratio of the capillaries.

to, the common large-vessel transit time, cannot be determined in our preparation.

In the present experiment, in the absence of correction for catheter distortion and large-vessel transit time, Kseq represents a lower-bound estimate: it will be slightly smaller than the actual value. Kseq can be obtained by linear regression of log ratio plots for ET-1 and albumin (Fig 2Down).



View larger version (11K):
[in this window]
[in a new window]
 
Figure 2. Natural logarithm of the ratio of the fractional recovery for albumin and tracer endothelin-1 (ET-1) as a function of time (from patient 6; see Fig 1Up). This plot depicts a linear increase over the entire primary dilution curve. A sequestration rate constant, Kseq, characterizing the unidirectional pulmonary removal of circulating ET-1, can be estimated from the slope of this relationship. See text for details.

irET-1 Measurements
Measurements were done according to a previously described technique.14 Before the bolus injection, paired samples of 10 mL blood were simultaneously collected from the aorta and the right ventricular outflow tract in EDTA-containing tubes and centrifuged at 1800g for 20 minutes. Plasma samples were then extracted with SepPak C18 cartridges (Waters) that had been activated with methanol, 8 mol/L urea, and water. Endothelin was eluted with 100% methanol, yielding a recovery of 75±3.3% (mean±SD). Samples and standards (ET-1; Peninsula Laboratories) were reconstituted in assay buffer and incubated for 24 hours with rabbit anti–ET-1 serum (Peninsula Laboratories) at 4°C. The addition of {approx}4000 counts per minute of 125I-ET-1 (Amersham) was followed by a second 24-hour incubation. Bound and free radioligands were separated by use of the second antibody method. The bound radioactivity data were evaluated after logit-log transformation.

The antibody exhibited a cross-reactivity of 10% for human big endothelin and 5% with endothelin-3 but no cross-reactivity with unrelated peptides (atrial natriuretic factor[1-28], brain natriuretic peptide, vasopressin, and angiotensins I and II). The limit of detection, defined as the least amount of irET-1 distinguishable from zero at a 95% confidence level, was 0.12 pg per tube. The intra-assay and interassay coefficients of variation were 9% and 12%, respectively, at the midpoint of the standard curve. Heparin in concentrations exceeding those achieved in the present experiments did not interfere with the assay. High-performance liquid chromatography of the plasma extract showed a dominant peak of irET-1 coeluting with the synthetic ET-1.

Endothelin Clearance and Production
Pulmonary ET-1 clearance was computed as follows:

where Fp is pulmonary plasma flow [pulmonary blood flow multiplied by (1-hematocrit)], MVET-1 represents mixed venous irET-1 level, and EXT is the mean cumulative ET-1 extraction.

Pulmonary ET-1 production was computed as follows:

where net pulmonary ET-1 balance is

Consequently, if aortic ET-1 levels are identical to MVET-1 levels, net ET-1 balance is 0 pg/min, and ET-1 clearance is equal to ET-1 production.

Statistical Analysis
All values are reported as mean±SD. When applicable, linear regression was used to detect correlations between different parameters. Two-tailed t tests were used to compare aortic and mixed venous ET-1 levels and pulmonary clearance and production of ET-1. Values were considered significantly different if P<.05.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
All patients had normal systemic and pulmonary hemodynamic parameters (Table 1Down). Mean left ventricular ejection fraction was 61±8%, and all patients had normal left ventricular angiograms.


View this table:
[in this window]
[in a new window]
 
Table 1. Demographic and Hemodynamic Parameters of the Study Patients Undergoing Elective Diagnostic Coronary Angiography

Fig 1Down shows a typical set of indicator-dilution curves obtained from patient 6 in linear (top) and logarithmic ordinate formats (bottom). Tracer albumin and ET-1 outflow profiles progressively diverge, the outflow fractional recovery of ET-1 becoming a progressively smaller proportion relative to that of tracer albumin; this is particularly evident on the logarithmic plot. Tracer recirculation is mathematically removed by linear extrapolation of the semilogarithmic downslope of the curves as shown in Fig 1Down. The difference between the areas of the extrapolated curves of albumin and ET-1 represents cumulative tracer ET-1 extraction during a single pulmonary transit time (52% for the patient shown in Fig 1Down).



View larger version (17K):
[in this window]
[in a new window]
 
Figure 1. Typical set of indicator-dilution curves obtained from patient 6. The fractional recovery per 1 mL blood for each tracer is plotted as a function of time in linear (top) and logarithmic (bottom) ordinate formats. Fractional recovery for tracer endothelin-1 (ET-1) rapidly diverges from the albumin, becoming a progressively smaller fraction with time. Linear extrapolation of the semilogarithmic downslope enables the mathematical removal of recirculating tracer. The difference between the areas of the extrapolated curves represents the cumulative circulating ET-1 extraction during a single pulmonary transit time. In this experiment, the extraction was 52%. The arrow on the abscissa represents the transit time of the collection system.

Indicator-dilution curve–derived parameters are assembled in Table 2Down. The mean pulmonary transit time for albumin was 11.9±1.4 seconds; that for tracer ET-1 was slightly lower at 11.4±1.4 seconds (P<.001). The central blood volume (composed primarily of pulmonary blood) was 1008±169 mL. Cardiac output and cardiac index were within normal limits: mean cardiac output, 5.16±1.01 L/min; mean cardiac index, 2.82±0.52 L·min-1·m-2. There was a substantial cumulative tracer ET-1 extraction in every patient ranging from 34.9% to 60.7% (mean, 47.4±7.1%). There was no correlation between ET-1 extraction and cardiac index (r=-.33, P=.27) or mean pulmonary artery pressure (r=-.164, P=.59). For each patient, instantaneous ET-1 extraction (the extraction at each time point of the dilution curves) increases linearly (not shown). By plotting the logarithmic ratio of the outflow profile of albumin over endothelin, we can gain additional insight into the microcirculatory behavior or of circulating ET-1. This ratio (Fig 2Up; patient 6) increases linearly over the entire primary dilution curve. This typical microcirculatory behavior of substances modified or inactivated by the pulmonary circulation has previously been well described and studied but is confirmed here for the first time in the human pulmonary circulation. This linear increase in extraction with time reflects the heterogeneity of the pulmonary capillary transit time distribution.24 Early in time, capillaries with shorter transit times contribute to the outflow profile. Later in time, capillaries with progressively increasing transit times contribute to an increase in ET-1 extraction. This resting heterogeneity of the pulmonary circulation has already been well described for ET-1 and for serotonin in dogs.3 24 The major difference for a tracer like serotonin is an apparent leveling off and plateau of the log ratio plot caused by return (or reentry) of tracer serotonin into circulation after it has been extracted. In this instance, the linear increase in the log ratio plot is maintained over the entire primary dilution curve, suggesting that ET-1 is extracted by the pulmonary circulation following a unidirectional process without any return of the extracted tracer to circulation.


View this table:
[in this window]
[in a new window]
 
Table 2. Pulmonary Clearance and Production of Circulating ET-1 in Humans From Indicator-Dilution Tracer ET-1 Extraction and Immunoreactive ET-1 Measurements Across the Pulmonary Circulation

Mean aortic irET-1 levels were not significantly different from mean pulmonary artery values: 0.68±33 and 0.61±0.29 pg/mL, respectively; P=.22 (Table 2Up). The absence of a significant AV difference in irET-1 across the pulmonary circulation in the presence of 47% mean cumulative tracer ET-1 extraction therefore supports a production of ET-1 quantitatively similar to the extracted amount. For each experiment, the indicator-dilution data were combined with irET-1 levels to determine net ET-1 clearance and production by the lungs. Mean ET-1 clearance is 884±458 pg/min, whereas production is slightly but nonsignificantly higher at 1101±682 pg/min (P=.15; Table 2Up). Fig 3Down gives the correlation between aortic and pulmonary irET-1 plasma values. There is a close linear relationship between the two following the regression equation,

(r=.85, P<.001). Despite a notable variability in individual irET-1 measurements, the regression line does not systematically deviate from a line of identity.



View larger version (15K):
[in this window]
[in a new window]
 
Figure 3. Plasma immunoreactive (ir) endothelin-1 levels measured simultaneously in the pulmonary arteries and aortas of patients undergoing diagnostic coronary angiograms. The solid line is a regression through the data points. The dotted line, representing a perfect correlation, is included for comparison.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
We have shown that the human lungs are an important site for both clearance and production of circulating ET-1. Within a single pulmonary transit time, 47±7% of ET-1 is extracted from the pulmonary circulation, with a simultaneous quantitatively similar release explaining the absence of an AV difference in irET-1 levels across the pulmonary vascular bed.

Previous studies have interpreted the lack of an ET-1 gradient across the human pulmonary circulation as evidence for the absence of extraction or release of this peptide by the lungs.12 13 The present analysis, however, clearly indicates that such conclusions must be made with caution when the experiments are not designed to simultaneously quantify and discern between clearance and production. In this study, the measurement of tracer ET-1 extraction combined with the simultaneous measurements of irET-1 levels enabled such an analysis. Such a methodology was previously validated in anesthetized dogs3 : the dog lungs removed 31±8% of tracer ET-1 with an equal production also explaining the absence in ET-1 gradient across the pulmonary vascular bed. The important role of the pulmonary circulation in the removal of circulating ET-1 has been established in various species: in rats, 82% of injected ET-1 is found in the lungs, with a smaller proportion in the kidneys.5 With the use of various techniques, it has been demonstrated that the lungs of dogs, rats, rabbits, and guinea pigs could extract {approx}40% to 70% of circulating ET-1, depending on the species and methodology used.3 5 6 7 8 9 This accumulating fundamental data strongly suggested a major role for the pulmonary circulation in the removal of circulating ET-1. This study confirms this important role in humans. A more detailed analysis of the indicator-dilution outflow profile for tracer ET-1 in relation to the albumin tracer supports the concept of heterogeneity of pulmonary capillary transit time distribution previously shown in animals.3 24 The outflow profile also indicates that ET-1 is removed unidirectionally following a single rate constant without any return of the extracted tracer to circulation in a single transit time. A simple model describing these events was applied to the data, and a sequestration rate constant for ET-1 was estimated: Kseq=0.048±0.019 s-1. This value is slightly lower than the value we obtained in dogs with the same technique: Kseq=0.056±0.016 s-1.3 In rats, injected ET-1 has a half-life of <7 minutes, and no ET-1 degradation products can be found in the circulation up to 60 minutes after injection.6 The retained ET-1 is found mostly in the lungs, associated with membranes and intracellular organelles.7 These observations, together with the present results, suggest that the extracted ET-1 is sequestrated by the vascular endothelium and does not return to circulation. Receptor-mediated endocytosis may mediate this extraction; the ETB receptor is present in the vascular endothelium, and the specific ETB antagonist BQ788 can reduce removal of ET-1 from the circulation.25

In normal subjects and patients with coronary artery disease, Stewart et al14 found slightly but significantly lower irET-1 levels in the aorta than in the pulmonary artery with a ratio that was significantly lower than unity (0.54±0.64 for coronary patients, P<.02). This led the authors to conclude that there may be net ET-1 clearance across the normal pulmonary circulation. In the same study, pulmonary hypertension patients had a ratio equal to (secondary hypertension) or greater than (primary hypertension) unity, suggesting a reduced clearance with possibly a net ET-1 production in pulmonary hypertensive conditions. Three other studies (including this one), however, found no significant AV difference in ET-1 levels across the human pulmonary circulation.12 13 It is possible that the different sampling site in the study of Stewart et al14 may have contributed to the lower AV ratio; some arterial samples were taken from the radial artery, and some venous samples were taken from the antecubital vein rather than from a mixed venous site. The intrinsic limitations of the irET-1 assay need to be considered in the overall analysis of these data. The intra-assay variability itself can explain many of the individual differences in paired aortic and pulmonary samples; mean values must therefore more adequately reflect true differences. In the present study, there was no significant difference between mean aortic and pulmonary artery irET-1 values.

The absence of an irET-1 gradient across the lungs, in the presence of simultaneous tracer ET-1 extraction (47±7%), suggests that the lung produces an amount of ET-1 similar to the amount that has been extracted. The human lung expresses ET-1 mRNA,11 and this expression is increased in patients with pulmonary hypertension.26 The pulmonary production of ET-1 therefore significantly contributes to circulating ET-1 levels, which explains the normal physiological ET-1 balance across the lungs.

Primary and secondary pulmonary hypertensions are associated with increased circulating ET-1 levels.14 15 16 17 19 20 21 In congestive heart failure, there is a direct correlation between pulmonary artery pressure and circulating ET-1 levels.19 20 In these patients, plasma ET-1 levels increase significantly from the pulmonary artery to the capillary wedge region, with a consequent net pulmonary ET-1 production that is also proportional to pulmonary vascular resistance.21 It is still debated whether circulating ET-1 is a simple marker or mediator of disease. ET-1 infused at pathophysiological concentrations exerts significant hemodynamic effects and may thus contribute to the counterregulatory mechanisms of chronic congestive heart failure.27 28 The present study brings new insight into the mechanisms of increased circulating ET-1 levels in humans. The lung may contribute to this process through a reduced clearance, an increase in production, or a combination of both. An increase in ET-1 production in pulmonary hypertension has been shown in humans.26 In the monocrotaline hypertensive rat, a reduced expression of the ETB receptor has been established.29 In normal dogs, the nonspecific ETA and ETB antagonist bosentan acutely increase circulating ET-1 levels up to 30-fold.30 Downregulation or reduced sensitivity of the ETB receptor may therefore contribute to increases in circulating ET-1 levels.

The human lung is an important metabolic organ. It produces, modifies, and inactivates various circulating amines and peptides. We must now add ET-1 to the list of its substrates and products. Close to 50% of circulating ET-1 is cleared in a single passage, with a simultaneous equal production that explains the normal physiological ET-1 balance across the human lungs. Future studies are needed to verify whether pharmacological or pathological alteration of this balance may modify circulating ET-1 levels. These new concepts should help in the clinical interpretation of increased circulating ET-1 values.


*    Acknowledgments
 
This work is supported by the Medical Research Council of Canada, the Fonds de la recherche en sante du Quebec, and the Canadian Heart and Stroke Foundation. We would like to thank Nathalie Ruel and Dominique Blais for their expert technical assistance, the staff of the invasive hemodynamic laboratory for their constant collaboration, and Claire Bertrand-St-Hilaire for typing the manuscript.

Received December 27, 1995; revision received April 16, 1996; accepted April 23, 1996.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. Yanagisawa M, Kurihara H, Kimura S, Tomobe Y, Kobayashi M, Mitsui Y, Yazaki Y, Goto K, Masaki T. A novel potent vasoconstrictor peptide produced by vascular endothelial cells. Nature. 1988;332:411-415.[Medline] [Order article via Infotrieve]
  2. Lerman A, Hildebrand FL Jr, Margulies KB, O'Murchu B, Perrella MA, Heublein DM, Schwab TR, Burnett JC Jr. Endothelin: a new cardiovascular regulatory peptide. Mayo Clin Proc. 1990;65:1441-1455.[Medline] [Order article via Infotrieve]
  3. Dupuis J, Goresky CA, Stewart DJ. Pulmonary removal and production of endothelin in the anesthetized dog. J Appl Physiol. 1994;76:694-700.[Abstract/Free Full Text]
  4. de Nucci G, Thomas R, D'Orleans-Juste P, Antunes E, Walder C, Warner TD, Vane JR. Pressor effects of circulating endothelin are limited by its removal in the pulmonary circulation and by the release of prostacyclin and endothelium-derived relaxing factor. Proc Natl Acad Sci U S A. 1988;85:9797-9800.[Abstract/Free Full Text]
  5. Sirvio ML, Metsarinne K, Saijonmaa O, Fyhrquist F. Tissue distribution and half-life of 125I-endothelin in the rat: importance of pulmonary clearance. Biochem Biophys Res Commun. 1990;167:1191-1195.[Medline] [Order article via Infotrieve]
  6. Shiba R, Yanagisawa M, Miyauchi T, Ishii Y, Kimura S, Uchiyama Y, Masaki T, Goto K. Elimination of intravenously injected endothelin-1 from the circulation of the rat. J Cardiovasc Pharmacol. 1989;13(suppl 5):S98-S101.
  7. Angga°rd E, Galton S, Rae G, Thomas R, McLoughlin L, de Nucci G, Vane JR. The fate of radioiodinated endothelin-1 and endothelin-3 in the rat. J Cardiovasc Pharmacol. 1989;13(suppl 5):S46-S49.
  8. Westcott JY, Henson J, McMurtry IF, O'Brien RF. Uptake and metabolism of endothelin in the isolated perfused rat lung. Exp Lung Res. 1990;16:521-532.[Medline] [Order article via Infotrieve]
  9. Rimar S, Gillis CN. Differential uptake of endothelin-1 by the coronary and pulmonary circulations. J Appl Physiol. 1992;73:557-562.[Abstract/Free Full Text]
  10. Firth JD, Ratcliffe PJ. Organ distribution of the three rat endothelin messenger RNAs and the effects of ischemia on renal gene expression. J Clin Invest. 1992;90:1023-1031.
  11. Nunez DJR, Brown MJ, Davenport AP, Neylon CB, Schofield JP, Wyse RK. Endothelin-1 mRNA is widely expressed in porcine and human tissues. J Clin Invest. 1990;85:1537-1541.
  12. Ray SG, McMurray JJ, Morton JJ, Dargie HJ. Circulating endothelin is not extracted by the pulmonary circulation in man. Chest. 1992;102:1143-1144.[Abstract/Free Full Text]
  13. Eaton GM, Bush CA, VanFossen DB, Kelley RE, Cody RJ. Absence of pulmonary endothelin gradient in patients with normal or elevated circulating endothelin. Am J Cardiol. 1994;73:1015-1016.[Medline] [Order article via Infotrieve]
  14. Stewart DJ, Levy RD, Cernacek P, Langleben D. Increased plasma endothelin-1 in pulmonary hypertension: marker or mediator of disease? Ann Intern Med. 1991;114:464-469.
  15. Yoshibayashi M, Nishioka K, Nakao K, Saito Y, Matsumura M, Ueda T, Temma S, Shirakami G, Imura H, Mikawa H. Plasma endothelin concentrations in patients with pulmonary hypertension associated with congenital heart defects: evidence for increased production of endothelin in pulmonary circulation. Circulation. 1991;84:2280-2285.[Abstract/Free Full Text]
  16. Miyauchi T, Yorikane R, Sakai S, Sakurai T, Okada M, Nishikibe M, Yano M, Yamaguchi I, Sugishita Y, Goto K. Contribution of endogenous endothelin-1 to the progression of cardiopulmonary alterations in rats with monocrotaline-induced pulmonary hypertension. Circ Res. 1993;73:887-897.[Abstract/Free Full Text]
  17. Cacoub P, Dorent R, Maistre G, Nataf P, Carayon A, Piette JC, Godeau P, Cabrol C, Gandjbakhch I. Endothelin-1 in primary pulmonary hypertension and the Eisenmenger syndrome. Am J Cardiol. 1993;71:448-450.[Medline] [Order article via Infotrieve]
  18. Stewart DJ. Endothelin in cardiopulmonary disease: factor paracrine vs neurohumoral. Eur Heart J. 1993;14(suppl I):48-54.
  19. Cody RJ, Haas GJ, Binkley PF, Capers Q, Kelley R. Plasma endothelin correlates with the extent of pulmonary hypertension in patients with chronic congestive heart failure. Circulation. 1992;85:504-509.[Abstract/Free Full Text]
  20. Rodeheffer RJ, Lerman A, Heublein DM, Burnett JC Jr. Increased plasma concentrations of endothelin in congestive heart failure in humans. Mayo Clin Proc. 1992;67:719-724.[Medline] [Order article via Infotrieve]
  21. Tsutamoto T, Wada A, Maeda Y, Adachi T, Kinoshita M. Relation between endothelin-1 spillover in the lungs and pulmonary vascular resistance in patients with chronic heart failure. J Am Coll Cardiol. 1994;23:1427-1433.[Abstract]
  22. Dupuis J, Goresky CA, Ryan JW, Rouleau JL, Bach GG. Pulmonary angiotensin-converting enzyme substrate hydrolysis during exercise. J Appl Physiol. 1992;72:1868-1886.[Abstract/Free Full Text]
  23. Dupuis J, Goresky CA, Juneau C, Calderone A, Rouleau JL, Rose CP, Goresky S. Use of norepinephrine uptake to measure lung capillary recruitment with exercise. J Appl Physiol. 1990;68:700-713.[Abstract/Free Full Text]
  24. Rickaby DA, Linehan JH, Bronikowski TA, Dawson CA. Kinetics of serotonin uptake in the dog lung. J Appl Physiol. 1981;51:405-414.[Abstract/Free Full Text]
  25. Fukuroda T, Fujikawa T, Ozaki S, Ishikawa K, Yano M, Nishikibe M. Clearance of circulating endothelin-1 by ETB receptors in rats. Biochem Biophys Res Commun. 1994;199:1461-1465.[Medline] [Order article via Infotrieve]
  26. Giaid A, Yanagisawa M, Langleben D, Michel RP, Levy R, Shennib H, Kimura S, Masaki T, Duguid WP, Stewart DJ. Expression of endothelin-1 in the lungs of patients with pulmonary hypertension. N Engl J Med. 1993;328:1732-1739.[Abstract/Free Full Text]
  27. Lerman A, Hildebrand FL Jr, Aarhus LL, Burnett JC Jr. Endothelin has biological actions at pathophysiological concentrations. Circulation. 1991;83:1808-1814.[Abstract/Free Full Text]
  28. Donckier JE, Hanet C, Berbinschi A, Galanti L, Robert A, Van Mechelen H, Pouleur H, Ketelslegers JM. Cardiovascular and endocrine effects of endothelin-1 at pathophysiological and pharmacological plasma concentrations in conscious dogs. Circulation. 1991;84:2476-2484.[Abstract/Free Full Text]
  29. Yorikane R, Miyauchi T, Sakai S, Sakurai T, Yamaguchi I, Sugishita Y, Goto K. Altered expression of ETB-receptor mRNA in the lung of rats with pulmonary hypertension. J Cardiovasc Pharmacol. 1993;22(suppl 8):S36-S338.
  30. Donckier J, Stoleru L, Hayashida W, Van Mechelen H, Selvais P, Galanti L, Clozel JP, Ketelslegers JM, Pouleur H. Role of endogenous endothelin-1 in experimental renal hypertension in dogs. Circulation. 1995;92:106-113.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. de Frutos, L. Duling, D. Alo, T. Berry, O. Jackson-Weaver, M. Walker, N. Kanagy, and L. Gonzalez Bosc
NFATc3 is required for intermittent hypoxia-induced hypertension
Am J Physiol Heart Circ Physiol, May 1, 2008; 294(5): H2382 - H2390.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J. Dupuis and M. M. Hoeper
Endothelin receptor antagonists in pulmonary arterial hypertension
Eur. Respir. J., February 1, 2008; 31(2): 407 - 415.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
B. Houweling, D. Merkus, O. Sorop, F. Boomsma, and D. J. Duncker
Role of endothelin receptor activation in secondary pulmonary hypertension in awake swine after myocardial infarction
J. Physiol., July 15, 2006; 574(2): 615 - 626.
[Abstract] [Full Text] [PDF]


Home page
Exp. Biol. Med.Home page
S. Sauvageau, E. Thorin, A. Caron, and J. Dupuis
Evaluation of endothelin-1-induced pulmonary vasoconstriction following myocardial infarction.
Experimental Biology and Medicine, June 1, 2006; 231(6): 840 - 846.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. J. Barst, D. Langleben, D. Badesch, A. Frost, E. C. Lawrence, S. Shapiro, R. Naeije, N. Galie, and on behalf of the STRIDE-2 Study Group
Treatment of Pulmonary Arterial Hypertension With the Selective Endothelin-A Receptor Antagonist Sitaxsentan
J. Am. Coll. Cardiol., May 16, 2006; 47(10): 2049 - 2056.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. Langleben, J. Dupuis, I. Langleben, A. M. Hirsch, M. Baron, J.-L. Senecal, and M. Giovinazzo
Etiology-Specific Endothelin-1 Clearance in Human Precapillary Pulmonary Hypertension
Chest, March 1, 2006; 129(3): 689 - 695.
[Abstract] [Full Text] [PDF]


Home page
Toxicol SciHome page
E. Thomson, P. Kumarathasan, P. Goegan, R. A. Aubin, and R. Vincent
Differential Regulation of the Lung Endothelin System by Urban Particulate Matter and Ozone
Toxicol. Sci., November 1, 2005; 88(1): 103 - 113.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. Migneault, S. Sauvageau, L. Villeneuve, E. Thorin, A. Fournier, N. Leblanc, and J. Dupuis
Chronically Elevated Endothelin Levels Reduce Pulmonary Vascular Reactivity to Nitric Oxide
Am. J. Respir. Crit. Care Med., March 1, 2005; 171(5): 506 - 513.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
H. Wang, A. F. Chen, S. W. Watts, J. J. Galligan, and G. D. Fink
Endothelin in the splanchnic vascular bed of DOCA-salt hypertensive rats
Am J Physiol Heart Circ Physiol, February 1, 2005; 288(2): H729 - H736.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
J. Dupuis
Increased endothelin levels in congestive heart failure: does it come from the lungs? Does it matter?
Cardiovasc Res, July 1, 2004; 63(1): 5 - 7.
[Full Text] [PDF]


Home page
Cardiovasc ResHome page
T. G von Lueder, H. Kjekshus, T. Edvardsen, E. Oie, S. Urheim, L. E. Vinge, M. S. Ahmed, O. A Smiseth, and H. Attramadal
Mechanisms of elevated plasma endothelin-1 in CHF: congestion increases pulmonary synthesis and secretion of endothelin-1
Cardiovasc Res, July 1, 2004; 63(1): 41 - 50.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
N. Galie, A. Manes, and A. Branzi
The endothelin system in pulmonary arterial hypertension
Cardiovasc Res, February 1, 2004; 61(2): 227 - 237.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S C Apostolopoulou, S Rammos, Z S Kyriakides, D J Webb, N R Johnston, D V Cokkinos, and D T. Kremastinos
Acute endothelin A receptor antagonism improves pulmonary and systemic haemodynamics in patients with pulmonary arterial hypertension that is primary or autoimmune and related to congenital heart disease
Heart, October 1, 2003; 89(10): 1221 - 1226.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
F. D. Wagner, S. Buz, C. Knosalla, R. Hetzer, and B. Hocher
Modulation of Circulating Endothelin-1 and Big Endothelin by Nitric Oxide Inhalation Following Left Ventricular Assist Device Implantation
Circulation, September 9, 2003; 108(90101): II-278 - 284.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
F S Benjaminov, M Prentice, K W Sniderman, S Siu, P Liu, and F Wong
Portopulmonary hypertension in decompensated cirrhosis with refractory ascites
Gut, September 1, 2003; 52(9): 1355 - 1362.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
P. Massoudy, J. A. Piotrowski, H. C.J.M. van de Wal, R. Giebler, G. Marggraf, J. Peters, and H. G. Jakob
Perfusing and ventilating the patient's lungs during bypass ameliorates the increase in extravascular thermal volume after coronary bypass grafting
Ann. Thorac. Surg., August 1, 2003; 76(2): 516 - 521.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
D. L. Brutsaert
Cardiac Endothelial-Myocardial Signaling: Its Role in Cardiac Growth, Contractile Performance, and Rhythmicity
Physiol Rev, January 1, 2003; 83(1): 59 - 115.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. F. Luscher, F. Enseleit, R. Pacher, V. Mitrovic, M. R. Schulze, R. Willenbrock, R. Dietz, V. Rousson, D. Hurlimann, S. Philipp, et al.
Hemodynamic and Neurohumoral Effects of Selective Endothelin A (ETA) Receptor Blockade in Chronic Heart Failure: The Heart Failure ETA Receptor Blockade Trial (HEAT)
Circulation, November 19, 2002; 106(21): 2666 - 2672.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
I. Schulze-Neick, J. Li, J. A. Reader, L. Shekerdemian, A. N. Redington, and D. J. Penny
The endothelin antagonist BQ123 reduces pulmonary vascular resistance after surgical intervention for congenital heart disease
J. Thorac. Cardiovasc. Surg., September 1, 2002; 124(3): 435 - 441.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Gastrointest. Liver Physiol.Home page
B. K. Oktar, M. A. Gulpinar, A. Bozkurt, S. Ghandour, S. Cetinel, H. Moini, B. C. Yegen, S. Bilsel, D. N. Granger, and H. Kurtel
Endothelin receptor blockers reduce I/R-induced intestinal mucosal injury: role of blood flow
Am J Physiol Gastrointest Liver Physiol, April 1, 2002; 282(4): G647 - G655.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Bauer, H. Wilkens, F. Langer, S. O. Schneider, H. Lausberg, and H.-J. Schafers
Selective Upregulation of Endothelin B Receptor Gene Expression in Severe Pulmonary Hypertension
Circulation, March 5, 2002; 105(9): 1034 - 1036.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. DAVIE, S. J. HALEEN, P. D. UPTON, J. M. POLAK, M. H. YACOUB, N. W. MORRELL, and J. WHARTON
ETA and ETB Receptors Modulate the Proliferation of Human Pulmonary Artery Smooth Muscle Cells
Am. J. Respir. Crit. Care Med., February 1, 2002; 165(3): 398 - 405.
[Abstract] [Full Text] [PDF]


Home page
HypertensionHome page
G. Egidy, E. Baviera, G. Ciuffo, P. Corvol, and F. Pinet
Localization of the Endothelin System in Aldosterone-Producing Adenomas
Hypertension, November 1, 2001; 38(5): 1137 - 1142.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P.J. Cowburn and J.G.F. Cleland
Endothelin antagonists for chronic heart failure: do they have a role?
Eur. Heart J., October 1, 2001; 22(19): 1772 - 1784.
[PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. R. Bond, B. H. Dorman, M. J. Clair, C. A. Walker, M. L. Pinosky, S. T. Reeves, S. Walton, J. M. Kratz, J. L. Ze