Methods and Results Thirty-five patients undergoing slow-pathway radiofrequency ablation for AVNRT were assigned to autonomic blockade (0.2 mg/kg propranolol and 0.04 mg/kg atropine; n=14) or isoproterenol (2 µg/min; n=21). Atrial fibrillation was induced before and after slow-pathway radiofrequency ablation. During autonomic blockade, the mean ventricular cycle length (448±34 versus 525±103 ms, P<.01) and maximum ventricular cycle length (640±105 versus 798±226 ms, P=.04) were prolonged after ablation, whereas the minimum ventricular cycle length did not change significantly (361±42 versus 403±83 ms, P=.05). During isoproterenol infusion, the mean ventricular cycle length (375±52 versus 390±61 ms, P=.2), maximum ventricular cycle length (520±88 versus 537±106 ms, P=.3), and minimum ventricular cycle length (307±59 versus 298±33 ms, P=.4) did not change significantly after slow-pathway ablation.
Conclusions Slow-pathway ablation slows the ventricular rate during atrial fibrillation under conditions of autonomic blockade but not during sympathetic stimulation. Therefore, slow-pathway ablation alone cannot account for the clinical results obtained with radiofrequency modification of AV conduction in patients with atrial fibrillation.
Key Words: catheter ablation ablation atrium fibrillation
| Introduction |
|---|
|
|
|---|
| Methods |
|---|
|
|
|---|
Electrophysiological Testing
The investigational protocol was approved by the Committee for Human Research at the University of Michigan. Informed consent was obtained from the patients, and the electrophysiological procedures were performed with patients in the fasting state after all antiarrhythmic medications had been discontinued for at least five half-lives. Three 7F quadripolar electrode catheters were inserted into the right femoral vein and positioned in the high right atrium, across the tricuspid valve to record the His bundle electrogram, and in the right ventricle. The catheter across the tricuspid valve had a 4-mm distal electrode and a deflectable tip (Mansfield EP) and was used for ablation. Leads V1, VII, and VIII and the intracardiac electrograms were displayed on an oscilloscope and recorded on a Mingograph 7 recorder (Siemens-Elema). Pacing was performed with a programmable stimulator (Bloom Associates).
The initial portion of the electrophysiology procedure was directed at determining the presence of dual AV nodal physiology, measuring the conduction properties and refractory periods of the fast and slow AV nodal pathways, and determining that the mechanism of the paroxysmal supraventricular tachycardia was typical AVNRT.6 Programmed stimulation and incremental pacing were performed in the right atrium and ventricle to define the anterograde and retrograde conduction and refractoriness of the AV node and to confirm that typical AVNRT could be reproducibly provoked.
Catheter Ablation Protocol
Radiofrequency energy was delivered by a generator that supplied a continuous unmodulated sine wave output at a frequency of 500 kHz. Mapping was performed in the posteroseptal right atrium, in the region of the coronary sinus. Suitable target sites for slow-pathway ablation were identified during sinus rhythm. Target sites were identified by an AV electrogram ratio <0.5 and by the presence of a multicomponent atrial electrogram.7 8 After a target site was identified, radiofrequency current was applied at 32 W for 10 to 60 seconds. The inducibility of AVNRT was assessed after each application of radiofrequency energy. In each patient, AVNRT was successfully eliminated. Induction of a single AV nodal echo by programmed stimulation in the baseline state and during the infusion of isoproterenol was considered an acceptable end point for the ablation procedure.9
The presence or absence of residual slow-pathway function was noted after successful ablation of AVNRT. The criteria for residual slow-pathway function consisted of dual AV nodal physiology and/or AV nodal echo beats after elimination of inducible AVNRT. AV nodal echo beats were defined as echo beats that had a concentric atrial activation sequence and occurred in association with prolongation of the AH interval, were reproducible, and occurred simultaneously with a QRS complex with a fixed VA relationship. Among the 13 patients assigned to autonomic blockade, residual slow-pathway function was present after slow-pathway ablation in only 1 patient. Among the 21 patients who received isoproterenol, 5 had residual slow-pathway function.
Study Protocol
To eliminate the possible confounding effects of changes in sympathetic or vagal tone, the study protocol was performed in 14 patients during autonomic blockade. Autonomic blockade was achieved with 0.04 mg/kg IV atropine and 0.2 mg/kg IV propranolol administered over 5 minutes.10 The initial doses of propranolol and atropine were 14.8±5.8 and 3.1±1.2 mg, respectively. To evaluate the effects of sympathetic stimulation, 21 other patients underwent the study protocol during the intravenous infusion of 2 µg/min of isoproterenol. Five minutes after administration of the drugs for autonomic blockade or when the steady-state effect of isoproterenol on the heart rate had been reached, atrial and ventricular incremental and programmed simulation was performed to define anterograde and retrograde AV node conduction and refractoriness. Atrial fibrillation was then induced by rapid atrial pacing at cycle lengths of 150 to 200 ms. The minimum duration of atrial fibrillation required for analysis was 15 seconds. The mean duration of atrial fibrillation used for analysis before and after ablation was 34.4±19.5 and 29.4±19.8 seconds (P=.4), respectively. The mean cycle length of the ventricular response and the minimum and maximum cycle lengths were determined. After successful catheter ablation, atropine and propranolol were administered to patients assigned to autonomic blockade in doses sufficient to achieve a sinus cycle length within 20 ms of the preablation sinus cycle length. After the ablation procedure, there was only one patient in whom the sinus cycle length was not within 20 ms of the preablation cycle length, and this patient received an additional 13.6 mg propranolol and 2.7 mg atropine. In the remaining 13 patients, the sinus cycle length was within 20 ms of the preablation sinus cycle length, and additional drug administration was not necessary. Isoproterenol was administered as described above in patients assigned to sympathetic stimulation. Electrophysiological testing and induction of atrial fibrillation were repeated after the ablation procedure.
Statistical Analysis
Continuous variables are expressed as mean±SD and were compared by use of a paired or unpaired t test when appropriate. Nominal variables were compared by
2 analysis. Probability values <.05 were considered statistically significant.
| Results |
|---|
|
|
|---|
|
The fast-pathway effective refractory period was 280±56 ms before ablation and 269±44 ms (P=.04) after ablation. The slow-pathway refractory period before ablation was 240±25 ms. Residual slow-pathway function was present in only one patient after ablation, and the slow-pathway effective refractory period was 260 ms. The postablation AV block cycle length (364±58 ms) did not change significantly from the preablation value (342±49 ms, P=.06). The mean preablation ventricular cycle length during atrial fibrillation correlated with the fast-pathway refractory period (r=.7, P<.01), the slow-pathway refractory period (r=.7, P=.03), and the shortest cycle length associated with 1:1 conduction during atrial pacing (r=.8, P=.001). After ablation, the mean ventricular cycle length during atrial fibrillation correlated with the shortest cycle length associated with 1:1 conduction during atrial pacing (r=.7, P<.01) but not with the postablation fast-pathway refractory period.
Sympathetic Stimulation
During isoproterenol infusion in 21 patients, the mean ventricular cycle length during atrial fibrillation did not change significantly (375±52 ms before versus 390±61 ms after ablation, P=.2; Fig 2
). Likewise, neither the maximum ventricular cycle length (520±88 versus 537±106 ms, P=.3) nor the minimum ventricular cycle length (307±59 versus 298±33 ms, P=.4) changed significantly after slow-pathway ablation. Slow-pathway function was completely eliminated in 17 of these 21 patients. The presence or absence of residual slow-pathway function did not affect the ventricular cycle length after ablation.
|
Before ablation, the fast-pathway effective refractory period, slow-pathway effective refractory period, and shortest cycle length associated with 1:1 conduction during atrial pacing were 227±26, 200±7, and 254±38 ms, respectively. After ablation, the fast-pathway refractory period (223±27 ms, P=.6), slow-pathway effective refractory period (210±17 ms, P=.3), and shortest cycle length associated with 1:1 conduction during atrial pacing (265±39 ms, P=.2) did not change significantly from preablation values. The fast-pathway effective refractory period in the five patients with residual slow-pathway function (236±21 ms) did not change significantly from the preablation value (244±27 ms, P=.1). Likewise, when residual slow-pathway function was not present after ablation, the fast-pathway effective refractory period (221±25 ms) did not change significantly from the preablation value (223±23 ms, P=.1). Before ablation, the mean ventricular cycle length during atrial fibrillation correlated with the fast-pathway (r=.6, P<.01) and slow-pathway (r=.7, P=.03) refractory periods but not with the shortest cycle length associated with 1:1 conduction during atrial pacing (P=.2). After ablation, the effective refractory period of the fast pathway (r=.5, P=.03) but not the slow pathway (P=.2) correlated with the postablation ventricular cycle length during atrial fibrillation. The shortest cycle length associated with 1:1 conduction during atrial pacing after ablation correlated with the mean ventricular cycle length during atrial fibrillation (r=.7, P=.001).
| Discussion |
|---|
|
|
|---|
Comparison With Previous Studies
Two prior studies investigated the effect of slow-pathway ablation on ventricular rate during atrial fibrillation.4 5 Both studies demonstrated slowing of the ventricular rate during atrial fibrillation after slow-pathway ablation. Blanck et al4 demonstrated this during autonomic blockade, whereas Tebbenjohanns and colleagues5 performed their study without pharmacological intervention. In these studies, the mean ventricular cycle length during atrial fibrillation was prolonged by 16% and 24%, respectively. However, neither study examined the effects of sympathetic stimulation. The present study found prolongation of the ventricular cycle length with autonomic blockade by a similar percentage (17%), but this is the only report to date to demonstrate the influence of sympathetic stimulation during atrial fibrillation after slow-pathway ablation. Because modification of AV conduction effectively slows the ventricular response during exercise and isoproterenol administration,1 administration of isoproterenol is important to include in any study designed to determine the mechanism responsible for the efficacy of this procedure.
Electrophysiological Effects
The fast-pathway effective refractory period has been noted to paradoxically shorten after successful slow-pathway ablation.11 12 The mechanism responsible for this phenomenon may be the removal of electrotonic effects on the fast pathway after the slow pathway is destroyed.4 13 14 The results of the present study in the setting of autonomic blockade confirm the results of these prior studies. During isoproterenol infusion, the fast-pathway effective refractory period was shortened by 17% compared with that during autonomic blockade. However, during sympathetic stimulation, the fast-pathway effective refractory period did not shorten any further after slow-pathway ablation. These results suggest that any possible electronic inhibition of the fast pathway by the slow pathway is eliminated in the setting of sympathetic stimulation.
The data presented here suggest that the AV node effective refractory periods and the shortest cycle length associated with 1:1 conduction during atrial pacing correlate with the mean atrial fibrillation cycle length before and after slow-pathway ablation. These results confirm the results of a previous study that demonstrated that the conductivity and refractory period of the AV node correlate with the ventricular rate during atrial fibrillation.15
Possible Mechanisms
Two mechanisms have been proposed to account for the therapeutic slowing of the ventricular rate during atrial fibrillation by radiofrequency catheter modification of AV conduction: slow-pathway ablation2 3 4 5 and partial ablation of the compact AV node.1
The data presented here and in previous reports demonstrate that the slow-pathway approach to ablation of AVNRT results in slowing of the ventricular response to atrial fibrillation in the setting of autonomic blockade.4 5 The results of the present study, however, demonstrate no effect of slow-pathway ablation on the ventricular rate during atrial fibrillation during isoproterenol administration. In contrast, radiofrequency catheter modification of AV conduction results in slowing of the ventricular rate during atrial fibrillation even during sympathetic stimulation.1 2 3 These results suggest that during rest or autonomic blockade, the predominant input to the AV node is through the slow pathway. Therefore, ablation of the slow pathway may result in slowing of the ventricular rate during atrial fibrillation. However, during sympathetic stimulation, the fast pathway may be activated so that slow-pathway ablation no longer affects the ventricular rate during atrial fibrillation. Prior studies demonstrated that the fast pathway often conducts slowly in the baseline state but rapidly during sympathetic stimulation.16 17 18 19 20 In these reports, VA conduction was absent or sluggish in the baseline state, but rapid retrograde conduction and inducible AVNRT became manifest during isoproterenol administration.16 17 18 19 20 A similar phenomenon would explain why slow-pathway ablation in the present study affected the ventricular rate in atrial fibrillation during autonomic blockade but not during isoproterenol administration.
Study Limitations
A possible limitation of this study is that some patients had relatively brief episodes of inducible atrial fibrillation. A previous study suggested that the mean ventricular rate during atrial fibrillation may be estimated accurately with a 20-second sample of atrial fibrillation, whereas a 120-second sample is required to estimate the minimum ventricular rate.21 In the present study, the minimum duration of atrial fibrillation used for analysis was 15 seconds (mean,
30 seconds). Therefore, errors in the mean ventricular cycle length resulting from inadequate sample duration probably were minimal.
Conclusions
In conclusion, the results of this study demonstrate that although slow-pathway ablation of the AV node results in a slowing of the ventricular rate during atrial fibrillation in the setting of autonomic blockade, there is no slowing of the ventricular rate during sympathetic stimulation. Therefore, the therapeutic response to radiofrequency modification of AV conduction to control the ventricular rate during atrial fibrillation, which is manifest under all conditions of autonomic tone,1 2 3 cannot be explained by slow-pathway ablation. This conclusion is different from the conclusions of previous studies that examined the effects of slow-pathway ablation on ventricular rate during atrial fibrillation, and this difference can be explained by the failure of other studies to determine the effects of sympathetic stimulation.4 5 These findings imply that the anterior inputs to the AV node are sufficient to manifest a rapid rate during atrial fibrillation even after ablation of the posterior inputs to the AV node. Therefore, it is likely that the therapeutic effects of radiofrequency modification of AV conduction to control the ventricular rate during atrial fibrillation are explained at least in part by injury to the AV node itself.
| Footnotes |
|---|
Received November 20, 1995; revision received March 6, 1996; accepted March 14, 1996.
| References |
|---|
|
|
|---|
2.
Feld GK, Fleck RP, Jujimura O, Prothro DL, Bahnson TD, Ibarra M. Control of rapid ventricular response by radiofrequency catheter modification of the atrioventricular node in patients with medically refractory atrial fibrillation. Circulation. 1994;90:2299-2307.
3. Bella PD, Carbucicchio C, Tondo C. Modulation of atrioventricular conduction by ablation of the `slow' atrioventricular node pathway in patients with drug-refractory atrial fibrillation or flutter. J Am Coll Cardiol. 1995;25:39-46.[Abstract]
4.
Blanck Z, Dhala AA, Sra J, Deshpande SS, Anderson AJ, Akhtar M, Jazayeri MR. Characterization of atrioventricular nodal behavior and ventricular response during atrial fibrillation before and after a selective slow-pathway ablation. Circulation. 1995;91:1086-1094.
5. Tebbenjohanns J, Pfeiffer D, Schumacher B, Jung W, Manz M, Luderitz B. Slowing of the ventricular rate during atrial fibrillation by ablation of the slow pathway of AV nodal reentrant tachycardia. J Cardiovasc Electrophysiol. 1995;6:711-715.[Medline] [Order article via Infotrieve]
6. Josephson ME. Clinical Cardiac Electrophysiology: Techniques and Interpretations. Philadelphia, Pa: Lea & Febiger; 1993:181-224.
7. Jackman WM, Beckman KJ, McClelland JH, Xunzhang W, Friday KJ, Roman CA, Moulton KP, Twidale N, Hazlitt HA, Prior MI, Oren J, Overholt ED, Lazzara R. Treatment of supraventricular tachycardia due to atrioventricular nodal reentry by radiofrequency catheter ablation of slow pathway conduction. N Engl J Med. 1992;327:313-318.[Abstract]
8.
Haissaguerre M, Gaita F, Fischer B, Commenges D, Montserrat P, D'Ivernois C, Lemetayer P, Warin JF. Elimination of atrioventricular nodal reentrant tachycardia using discrete slow potentials to guide application of radiofrequency energy. Circulation. 1992;85:2162-2175.
9. Hummel JD, Strickberger SA, Williamson BD, Man KC, Daoud E, Niebauer M, Baker O, Morady F. Effect of residual slow pathway function on the time course of recurrences of atrioventricular nodal reentrant tachycardia after radiofrequency ablation of the slow pathway. Am J Cardiol. 1995;75:628-630.[Medline] [Order article via Infotrieve]
10. Jose AD, Taylor RR. Autonomic blockade by propranolol and atropine to study intrinsic myocardial function in man. J Clin Invest. 1969;48:2019-2031.
11.
Kay GN, Epstein AE, Dailey SM, Plumb VJ. Selective radiofrequency ablation of the slow pathway for the treatment of atrioventricular nodal reentrant tachycardia: evidence for involvement of perinodal myocardium within the reentrant circuit. Circulation. 1992;85:1675-1677.
12. Wathen M, Natale A, Wolfe K, Yee R, Newman D, Klein G. An anatomically guided approach to atrioventricular node slow pathway ablation. Am J Cardiol. 1992;70:886-889.[Medline] [Order article via Infotrieve]
13.
Natale A, Klein G, Yee R, Thakur R. Shortening of fast pathway refractoriness after slow pathway ablation: effects of autonomic blockade. Circulation. 1994;89:1103-1108.
14. Strickberger SA, Daoud E, Niebauer M, Williamson BD, Man KC, Hummel JD, Morady F. Effects of partial and complete ablation of the slow pathway on fast pathway properties in patients with atrioventricular nodal reentrant tachycardia. J Cardiovasc Electrophysiol. 1994;5:645-649.[Medline] [Order article via Infotrieve]
15. Toivonen L, Kadish A, Kou W, Morady F. Determinants of the ventricular rate during atrial fibrillation. J Am Coll Cardiol. 1990;16:1194-1200.[Abstract]
16.
Hariman RJ, Gomes JA, El-Sherif N. Cathecholamine-dependent atrioventricular nodal reentrant tachycardia. Circulation. 1983;67:681-686.
17. Brownstein SL, Hopson RC, Martins JB, Aschoff AM, Olshansky B, Constantin L, Keinzle MG. Usefulness of isoproterenol in facilitating atrioventricular nodal reentry tachycardia during electrophysiologic testing. Am J Cardiol. 1988;61:1037-1041.[Medline] [Order article via Infotrieve]
18. Hycke EC, Lai WT, Nguyen NX, Keung EC, Sung RF. Role of intravenous isoproterenol in the electrophysiologic induction of atrioventricular node reentrant tachycardia in patients with dual atrioventricular node pathways. Am J Cardiol. 1989;64:1131-1137.[Medline] [Order article via Infotrieve]
19. Kerr CR, Murdock CJ, Yeung-Lai-Wah JA. Atrioventricular nodal reentrant tachycardia in patients with ventriculoatrial conduction block. Can J Cardiol. 1994;10:255-258.
20. Glotzer T, Evans S, Bernstein N, Chinitz L. Specificity of retrograde conduction in screening of atrioventricular nodal reentrant tachycardia. PACE Pacing Clin Electrophysiol. 1994;17(pt 2):2134-2136.
21. Watt JH, Donner AP, McKinney CM, Klein GJ. Atrial fibrillation: minimal sampling interval to estimate average rate. J Electrocardiol. 1984;17:153-156.[Medline] [Order article via Infotrieve]
This article has been cited by other articles:
![]() |
A. D. Krahn, G. J. Klein, R. Yee, M. N. Basta, and J. K. Lee Progressive Anterior Ablation in the Coronary Sinus Region : Evidence to Support the Presence of a `Slow Pathway' Input in Normal Patients? Circulation, November 18, 1997; 96(10): 3477 - 3483. [Abstract] [Full Text] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1996 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |