(Circulation. 2009;119:735-741.)
© 2009 American Heart Association, Inc.
Vascular Medicine |
From the Departments of Vascular Surgery (Z.H.D., W.G.F., Y.Q.W., D.Q.G., X.X., B.C., J.H.J., J.Y., Z.Y.S., T.Z., Y.S.) and Pathology (Y.J.), Zhongshan Hospital, Fudan University, Shanghai, China.
Correspondence to Wei Guo Fu, MD, Department of Vascular Surgery, Zhongshan Hospital, Fudan University, 180 Fenglin Rd, Shanghai 200032, China. E-mail fu.weiguo{at}zs-hospital.sh.cn
Received January 8, 2008; accepted December 5, 2008.
| Abstract |
|---|
|
|
|---|
Methods and Results— Eleven of 443 patients developed retrograde type A aortic dissection during or after stent grafting for type B dissection from August 2000 to June 2007. Of these 11 patients, 3 had Marfan syndrome. The Kaplan–Meier estimate of the rate of freedom from this event at 36 months is 97.4% (95% confidence interval, 0.95 to 0.99). The new entry was located at the tip of the proximal bare spring of the stent graft in 9 patients, was within the anchoring area of the proximal bare spring in 1, and remained unknown in 1 patient. Eight patients were converted to open surgery, and 2 received medical treatment. One patient suddenly died 2 hours after the primary stent grafting, and 2 died within 1 week after the surgical conversion, so mortality reached 27.3%. During the follow-up from 3 to 50 months, type I endoleak was identified in 1 patient 3 months after the surgical exploration and disappeared at 6 months.
Conclusions— Retrograde type A aortic dissection after stent grafting for type B dissection appears not to be rare and results from mixed causes. Fragility of the aortic wall and disease progression may predispose to it, whereas stent grafting–related factors make important and provocative contributions. Avoiding aortic arch stent grafting in Marfan patients, preferably selecting the endograft without the proximal bare spring for patients with a kinked aortic arch or with Marfan syndrome (if endografting is used), improving the device design, and standardizing endovascular manipulation might lessen its occurrence.
Key Words: aortic dissection endovascular surgery grafting stents
| Introduction |
|---|
|
|
|---|
Clinical Perspective p 741
| Methods |
|---|
|
|
|---|
|
|
Stent Graft System
The Talent stent graft system (Medtronic, Minneapolis, Minn) was used in all 11 patients. It consists of a segmental nitinol stent skeleton covered with polyester (Dacron) and a straight nitinol connecting bar longitudinally linking the stent graft and preventing twisting or kinking. It has a proximal bare spring with strong radial force for strengthening its fixation and preventing migration. The delivery system contains a covering sheath and a placement catheter over which the self-expanding stent graft was compressed. Deployment was achieved by fixing the placement catheter and pulling back the covering sheath. The endoprosthesis was selected with 10% to 15% oversizing according to the measurement on contrast-enhanced computed tomography (CT).
In total, 7 types of devices have been applied in 443 patients. The percentage of patients implanted with each system and its relevant characteristics are listed in Table 3.
|
Endovascular Stent Graft Placement
The endovascular procedure has been detailed elsewhere.4 Two aspects potentially associated with RTAD are highlighted as follows. First, given that the high-velocity flow frequently caused displacement of the stent graft on release of its proximal segments (windsock effect) although mean arterial pressure was pharmaceutically lowered to 50 to 60 mm Hg at the time of deployment, we routinely placed the system 2 cm ahead of the anticipated landing zone before releasing to offset such foreseeable migration. If the stent graft did not migrate as far as expected after being partially deployed and landed proximal to the intended position, we gently pulled the whole system back to the ideal location and then fully deployed it. If the proximal landing zone, the distance from the origin of the left subclavian artery to the primary entry site, measured <15 mm, 2 strategies were applied to create an extra anchoring area: intentional coverage of the left subclavian artery and right-to-left carotid and left-carotid-to-left-subclavian arterial bypass, both of which have been described in detail.6 Second, balloon inflation was avoided in all 11 patients.
Treatment of RTAD
Both surgical and medical treatments were used in this series. The surgical conversion represented graft replacement of the ascending thoracic aorta with or without partial or total aortic arch replacement and was the first choice at the onset of RTAD. Medical management was chosen only if RTAD was limited and the patients remained clinically stable, with β-blockers, angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, or calcium antagonists administrated either alone or in combination to maintain the systolic blood pressure <140 mm Hg.
Follow-Up Protocol
Patients were followed up by CT at 1 month, 3 months, 6 months, and yearly thereafter both after the primary endografting and after the treatment of RTAD.
Statistical Analysis
The Kaplan–Meier method was used to estimate the rate of freedom from RTAD, and the Greenwood method was used for the corresponding 95% confidence intervals. The analysis was completed with STATA8.0 software (Stata Corp, College Station, Tex).
The authors had full access to and take full responsibility for the integrity of the data. All authors have read and agree to the manuscript as written.
| Results |
|---|
|
|
|---|
RTAD developed intraoperatively in 2 patients, 2 hours after the procedure in 1 patient, at 1 week in 1 patient, at 1 month in 2 patients, at 6 months in 1 patient, at 9 months in 1 patient, at 12 months in 1 patient, at 29 months in 1 patient, and at 36 months in 1 patient. The Kaplan–Meier estimate of the rate of freedom from RTAD at 36 months was 97.4% (95% confidence interval, 0.95 to 0.99; Figure 1). The clinical manifestations included syncope, hypotension, dyspnea, hypoxemia, chest pain, and sudden death. Patient 11 died suddenly of pericardial tamponade 2 hours after endografting, and RTAD was highly suspected but could not be confirmed by autopsy because, disappointingly, the patients family refused consent. In the remaining 10 patients, the new entry site was identified at the tip of the proximal bare spring in 9 patients and within the area where the proximal bare spring anchored in 1 patient by intraoperative angiogram, CT, or surgical conversion.
|
Eight patients received graft replacement of the ascending thoracic aorta with or without partial or total arch replacement. Two patients were treated medically. Eight patients survived; 6 were followed up for 3 to 50 months (mean, 20 months), and 2 were lost. Type I endoleak was identified in patient 1 at 3 months after the surgical conversion but disappeared at 6 months (Figure 2). In patient 3, a new entry at the distal end of the stent graft that had been detected 1 month before the development of RTAD remained opacified 12 months after the open surgery (Figure 3), but the patient refused to have an additional stent graft implanted. Complete false lumen thrombosis of the thoracic aorta was demonstrated on CT 3 months after the surgical conversion in the remaining 4 patients. Three patients (patients 11, 10, and 8) died perioperatively; mortality reached 27.3%. Patient 11 was described above. Patient 10 was also a Marfan syndrome patient, and the stent graft was intended to be fixed immediately distal to the origin of the left common carotid artery with coverage of the left subclavian artery. During the deployment, the stent graft migrated slightly distal to the anticipated position after its first segment was partially released. We pushed the whole delivery system forward gently and then fully deployed it, achieving the anticipated alignment. However, the completion angiogram demonstrated limited extravasation of contrast at the origin of the innominate artery where the tip of the proximal bare spring reached (Figure 4). Given her hemodynamic stability and difficulty in endovascular management at this site, no immediate intervention was carried out. Two hours later, the patient presented with hypoxemia, and RTAD was detected by transthoracic echocardiography. The patient died of multiple organ failure 5 days after an emergency ascending thoracic aorta and total arch replacement. Patient 8 manifested dyspnea 1 week after the stent grafting, and CT revealed RTAD. Ultimately, he also died of multiple organ failure 1 day after emergency graft replacement of the ascending thoracic aorta and total arch.
|
|
|
| Discussion |
|---|
|
|
|---|
The fragility of the aortic wall and disease progression were deemed to predispose to RTAD because new type A dissection was not specific to stent graft placement. Rather, it developed after open surgery or even during drug management of type B dissection patients.34–37 Hata et al36 investigated the prognosis of 180 patients with acute type B dissection under medical management, and newly developed type A dissection was observed in 4 cases. Winnerkvist et al37 reported new type A dissection developing in 5 of 66 candidates in a prospective study of medical treatment of acute type B dissection. Furthermore, some of patients with post–stent grafting type A dissection had a spontaneous new entry irrelevant to the endoprosthesis. Scheinert et al29 presented 1 case with the new tear in the ascending thoracic aorta
2 cm from the aortic valve 3 months after endovascular repair for ruptured pseudoaneurysm related to type B dissection. These data indicate that type B dissection is inherently vulnerable to progressively involving the ascending thoracic aorta.
Noticeably, 3 patients were diagnosed with Marfan syndrome according to the revised Gent criteria in this series,38 accounting for up to 27% (3 of 11), similar to that in the published articles (13.5%, 5 of 37).3,16,18,22,26 Interestingly, it was also observed in our center that post–stent grafting RTAD represented the most common complication among Marfan patients. In total, we have performed endografting in 6 type B dissections with Marfan syndrome, of whom 4 had solitary type B dissection and 2 previously underwent the Bentall procedure for type A dissection. Among the former 4 cases, 3 experienced diagnosed RTAD presented in the present series, and 1 had suspected RTAD; in this patient, satisfactory exclusion of the proximal entry had been achieved with 2 overlapped stent grafts (Talent proximally, Ankura distally), but the patient died suddenly 2 weeks after the procedure when she was discharged home. These findings suggest that Marfan syndrome predisposes to post–stent grafting RTAD, which appears consistent with Marfans well-recognized pathological and clinical characteristics, namely the aortic wall fragility and a tendency to progressively involve the residual aorta after either surgical or endovascular treatment for the primarily affected aortic segment.39,40 From this standpoint, the considerable proportion that Marfan made up among RTAD cases could, to a certain extent, support the inference that the aortic wall fragility and disease progression contribute to the occurrence of RTAD. Nevertheless, only a small number of cases are included in the present study, and the established association between Marfan and RTAD is pending further investigation with a larger sample.
As far as stent grafting–related factors are concerned, the injury from the proximal bare spring is taken into account first, which is designed to open widely without the constraint by polyester graft and to provide strong radial force to strengthen the proximal fixation. However, the stronger the radial force is, the higher the risk of injury on the aortic wall is. By reviewing the published articles,3,7–33 we found 37 patients who experienced RTAD after endografting for type B dissection; a stent graft with a proximal bare spring was used in at least 27 patients (73.0%),7–10,14–17,19–25,30 an endoprosthesis without a bare stent was implanted in 2 patients,13,33 and the type of device was unavailable in the remaining 8 patients. In our series, a prosthesis with a proximal bare spring was used in all 11 patients. Although this type of stent graft might be more readily available and widely used, it is still strongly suggested that the proximal bare spring plays an important provocative role in the development of RTAD, considering the fact that the new entry was located at the tip of the proximal bare spring in 81.8% (9 of 11) of the patients in our series and in 55.6% (15 of 27) of the patients in the published articles.7,9–11,16,17,22,23,30,33 On the other hand, however, it appears to be fairly rash to establish a specific association between the Talent device and RTAD in the absence of a randomized control study, although it was implanted in all 11 cases in the present survey.
Second, placement of the stent graft at the aortic arch probably correlates with the development of RTAD. In all patients in this series and most patients in the literature, the endograft was placed at the arch. When passively bent at the arch, the self-expanding endoprosthesis has the inherent tendency to spring back to its initial straight status, especially in the presence of the longitudinal connecting bar. Such spring-back strength could generate a stress on the greater curve, particularly at 2 ends of the graft, and create a new entry at one or both ends, such as the occurrence of new tear at both ends of the device in patient 3 (Figures 3 and 5
). Generally, the pointed tip of the proximal bare spring could yield higher-intensity pressure than the fabric-covered portion of the graft and would more readily lead to injury, which would be more risky if the angulation is formed between the bare spring and the aortic wall in the setting of kinking of the arch. The overall stiffness of the endoprosthesis might also precipitate aortic wall injury by hampering its optimal arch alignment and intensifying its interaction with the aorta under the high-velocity pulsatile flow. Xu et al16 and Pitton et al28 considered the connecting bar to be partially responsible for RTAD because it sacrificed flexibility and increased the overall stiffness. The support spine of the Valiant device (Medtronic), currently used in our center, has been removed to offer better flexibility. Additionally, kinking of the arch could make unstable the deployment strategy of pulling the covering sheath caudal and cause forward and backward movements of the bare spring and resultant injury of the aortic wall. Pamler et al23 reported 2 cases of RTAD caused by arch kinking.
|
Third, the injury could result from endovascular manipulation. In patient 9, RTAD was ascribed to a cutting injury by the radiopaque gold markers of the angiographic catheter placed in the ascending thoracic aorta through the left subclavian artery across which the proximal bare spring was intentionally placed that thus pressed the catheter against the aortic wall. Consequently, when the catheter was pulled back, the gold marker protruding a little over the catheter surface generated a cutting force on the greater curve, and a new tear formed. In patient 10, the aortic wall was injured by pushing forward the partially released stent graft. RTAD in 2 patients presented by Won et al3 and Lee et al18 was attributed to guidewire-induced injury. Balloon inflation also could cause injury on the wall, particularly when the stent graft is attached proximally on the already involved aorta.7,41 During the early years in our center, balloon inflation was used on a regular basis to augment the fixation of the stent graft and to minimize endoleak until it resulted in terrible migration in several cases, which prompted us to investigate whether the instant mild type I endoleak was left without ballooning. Interestingly, spontaneous seal within 3 months was evidenced on follow-up CT in >90% of cases with slight type I endoleak, which had been detected in 17.6% of patients at the completion of the primary stent grating4 such as patient 3 (Figure 3). Therefore, balloon inflation might be reasonably spared in most patients except for those with marked endoleak.
In consideration of these causes, some strategies could be conducive to the prevention of RTAD. First, close attention should be paid to patient and device selection. Stent grafting at the aortic arch should be avoided in Marfan patients unless the candidate has had a previous graft replacement of the ascending aorta, arch, or both. The device without the proximal bare spring is recommended when endografting is applied in patients with a kinked aortic arch or with Marfan syndrome (without previous graft replacement). Second, the design of the stent graft system should be improved; in particular, the development of a device specific for dissection is worth considering because currently available devices are designed mainly for atherosclerotic aneurysms. A marked difference exists between stent grafting for dissections and stent grafting for atherosclerotic aneurysms. In atherosclerotic aneurysms, the stable fixation of the stent graft relies on a relatively short but normal proximal and distal neck, which necessitates and tolerates the strong radial force of the stent graft. In contrast, in dissections, the entire length of the stent graft attaches to the aorta; hence, lower radial force is required. Furthermore, the aortic wall, especially the distal landing area, is usually involved by dissection and has worse resistance to the radial force of the device. Therefore, the endoprosthesis designed for dissections calls for lower radial force and higher flexibility. Additionally, given that the stent graft is frequently placed across the distal arch and curved in dissection patients, biomechanical properties are worth taking into account during device design to minimize the potential stress injury provoked by the passively bent endograft. Third, excessive oversizing of the stent graft should be avoided; 10% to 15% appears to be adequate. Fourth, standardized endovascular manipulation cannot be overemphasized. For example, the partially released stent graft should never be pushed forward. Finally, the stent graft ideally should be landed proximally on the uninvolved aortic wall. If it has to be landed proximally on the dissected wall, balloon inflation should be avoided.
| Conclusions |
|---|
|
|
|---|
| Acknowledgments |
|---|
None.
| References |
|---|
|
|
|---|
2. Nienaber CA, Fattori R, Lund G, Dieckmann C, Wolf W, von Kodolitsch Y, Nicolas V, Pierangeli A. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Engl J Med. 1999; 340: 1539–1545.
3. Won JY, Suh SH, Ko HK, Lee KH, Shim WH, Chang BC, Choi DH, Park SJ, Lee do Y. Problems encountered during and after stent-graft treatment of aortic dissection. J Vasc Interv Radiol. 2006; 17: 271–281.[CrossRef][Medline] [Order article via Infotrieve]
4. Fu WG, Shi Y, Wang YQ, Guo DQ, Xu X, Chen B, Jiang JH, Yang J, Shi ZY. Endovascular therapy for Stanford type B aortic dissection in 102 cases. Asian J Surg. 2005; 28: 271–276.[Medline] [Order article via Infotrieve]
5. Marui A, Mochizuki T, Mitsui N, Koyama T, Kimura F, Horibe M. Toward the best treatment for uncomplicated patients with type B acute aortic dissection: a consideration for sound surgical indication. Circulation. 1999; 100 (suppl): II-275–II-280.
6. Fu WG, Dong ZH, Wang YQ, Guo DQ, Xu X, Chen B, Jiang JH, Yang J, Shi ZY. Strategies for managing the insufficiency of the proximal landing zone during endovascular thoracic aortic repair. Chin Med J. 2005; 13: 1066–1071.
7. Rubin S, Bayle A, Poncet A, Baehrel B. Retrograde aortic dissection after a stent graft repair of a type B dissection: how to improve the endovascular technique. Interact Cardiovasc Thorac Surg. 2006; 5: 746–748.
8. Savini C, Casselman F, Ergenoglu MU, Degrieck I, Van Praet F, De Geest R, Wellens F, Jeanmart H, Vanermen H. Surgical management of progression to type A dissection from an intramural hematoma previously treated with endovascular stent graft placement. J Thorac Cardiovasc Surg. 2004; 128: 773–775.
9. Panos A. Late retrograde aortic perforation by the uncovered part of an endograft: an increasing complication. Hellenic J Cardiol. 2007; 48: 115–116.[Medline] [Order article via Infotrieve]
10. Modine T, Lions C, Destrieux-Garnier L, Haulon S, Decoene C, Beregi JP, Koussa M. Iatrogenic iliac artery rupture and type A dissection after endovascular repair of type B aortic dissection. Ann Thorac Surg. 2004; 77: 317–319.
11. Misfeld M, Notzold A, Geist V, Richardt G, Sievers HH. Retrograde type A dissection after endovascular stent grafting of type B dissection [in German]. Z Kardiol. 2002; 91: 274–277.[CrossRef][Medline] [Order article via Infotrieve]
12. Urbanski PP. Retrograde extension of type B dissection after endovascular stent graft repair. Eur J Cardiothorac Surg. 2002; 21: 767–789.
13. Fanelli F, Salvatori FM, Marcelli G, Bezzi M, Totaro M, Vagnarelli S, Dake MD, Rossi P, Passariello R. Type A aortic dissection developing during endovascular repair of an acute type B dissection. J Endovasc Ther. 2003; 10: 254–259.[CrossRef][Medline] [Order article via Infotrieve]
14. Duebener L, Hartmann F, Kurowski V, Richardt G, Geist V, Erasmi A, Sievers HH, Misfeld M. Surgical interventions after emergency endovascular stent-grafting for acute type B aortic dissections. Interact Cardiovasc Thorac Surg. 2007; 6: 288–292.
15. Grabenwoger M, Fleck T, Ehrlich M, Czerny M, Hutschala D, Schoder M, Lammer J, Wolner E. Secondary surgical interventions after endovascular stent-grafting of the thoracic aorta. Eur J Cardiothorac Surg. 2004; 26: 608–613.
16. Xu SD, Huang FJ, Yang JF, Li ZZ, Wang XY, Zhang ZG, Du JH. Endovascular repair of acute type B aortic dissection: early and mid-term results. J Vasc Surg. 2006; 43: 1090–1095.[CrossRef][Medline] [Order article via Infotrieve]
17. Fattori R, Napoli G, Lovato L, Grazia C, Piva T, Rocchi G, Angeli E, Di Bartolomeo R, Gavelli G. Descending thoracic aortic diseases: stent-graft repair. Radiology. 2003; 229: 176–183.
18. Lee KH, Won JY, Lee DY, Choi D, Shim WH, Chang BC. Elective stent-graft treatment of aortic dissections. J Endovasc Ther. 2004; 11: 667–675.[CrossRef][Medline] [Order article via Infotrieve]
19. Czermak BV, Waldenberger P, Perkmann R, Rieger M, Steingruber IE, Mallouhi A, Fraedrich G, Jaschke WR. Placement of endovascular stent-grafts for emergency treatment of acute disease of the descending thoracic aorta. AJR Am J Roentgenol. 2002; 179: 337–345.
20. Hansen CJ, Bui H, Donayre CE, Aziz I, Kim B, Kopchok G, Walot I, Lee J, Lippmann M, White RA. Complications of endovascular repair of high-risk and emergent descending thoracic aortic aneurysms and dissections. J Vasc Surg. 2004; 40: 228–234.[CrossRef][Medline] [Order article via Infotrieve]
21. Kato N, Shimono T, Hirano T, Suzuki T, Ishida M, Sakuma H, Yada I, Takeda K. Midterm results of stent-graft repair of acute and chronic aortic dissection with descending tear: the complication-specific approach. J Thorac Cardiovasc Surg. 2002; 124: 306–312.
22. Shim WH, Koo BK, Yoon YS, Choi D, Jang Y, Lee DY, Chang BC. Treatment of thoracic aortic dissection with stent-grafts: midterm results. J Endovasc Ther. 2002; 9: 817–821.[CrossRef][Medline] [Order article via Infotrieve]
23. Pamler RS, Kotsis T, Görich J, Kapfer X, Orend KH, Sunder-Plassmann L. Complications after endovascular repair of type B aortic dissection. J Endovasc Ther. 2002; 9: 822–828.[CrossRef][Medline] [Order article via Infotrieve]
24. Li ZZ, Xu SD, Zheng SH, Li ZA, Du JH, Sun YQ. Interventional treatment of thoracic aortic dissection with stent-graft placement guided by transesophageal echocardiography [in Chinese]. Zhonghua Nei Ke Za Zhi. 2004; 43: 26–28.[Medline] [Order article via Infotrieve]
25. Shimono T, Kato N, Yasuda F, Suzuki T, Yuasa U, Onoda K, Hirano T, Takeda K, Yada I. Transluminal stent-graft placements for the treatments of acute onset and chronic aortic dissections. Circulation. 2002; 106 (suppl): I-241–I-247.
26. Jing ZP, Feng X, Bao JM, Zhao ZQ, Zhao J, Lu QS, Qu LF, Ye BY. Endovascular stent-graft exclusion for Stanford B type aortic dissections: a report of 146 patients [in Chinese]. Zhonghua Wai Ke Za Zhi. 2003; 41: 483–486.[Medline] [Order article via Infotrieve]
27. Bortone AS, Schena S, D'Agostino D, Dialetto G, Paradiso V, Mannatrizio G, Fiore T, Cotrufo M, de Luca Tupputi Schinosa L. Immediate versus delayed endovascular treatment of post-traumatic aortic pseudoaneurysms and type B dissections: retrospective analysis and premises to the upcoming European trial. Circulation. 2002; 106 (suppl): I-234–I-240.
28. Pitton MB, Schmiedt W, Neufang A, Herber S, Düber C, Thelen M. Emergency endovascular treatment of acute aortic diseases [in German]. Rofo. 2002; 174: 593–599.[Medline] [Order article via Infotrieve]
29. Scheinert D, Krankenberg H, Schmidt A, Gummert JF, Nitzsche S, Scheinert S, Bräunlich S, Sorge I, Krakor R, Biamino G, Schuler G, Mohr FW. Endoluminal stent-graft placement for acute rupture of the descending thoracic aorta. Eur Heart J. 2004; 25: 694–700.
30. Gawenda M, Brunkwall J. Device related problems of thoracic stent-grafts [in German]. Zentralbl Chir. 2007; 132: 205–210.[CrossRef][Medline] [Order article via Infotrieve]
31. Duebener LF, Lorenzen P, Richardt G, Misfeld M, Nötzold A, Hartmann F, Sievers HH, Geist V. Emergency endovascular stent-grafting for life-threatening acute type B aortic dissections. Ann Thorac Surg. 2004; 78: 1261–1266.
32. Oertel F, Sirch J, Bockler D, Klein M, Raithel D, Beyer M. Delayed type A dissection after primary successful interventional treatment with endoluminal stent graft of the descending thoracic aorta. Thorac Cardiovasc Surg. 2002; 50: 180–181.[CrossRef][Medline] [Order article via Infotrieve]
33. Neuhauser B, Czermak BV, Fish J, Perkmann R, Jaschke W, Chemelli A, Fraedrich G. Type A dissection following endovascular thoracic aortic stent-graft repair. J Endovasc Ther. 2005; 12: 74–81.[CrossRef][Medline] [Order article via Infotrieve]
34. Clouse WD, Marone LK, Davison JK, Dorer DJ, Brewster DC, LaMuraglia GM, Cambria RP. Late aortic and graft-related events after thoracoabdominal aneurysm repair. J Vasc Surg. 2003; 37: 254–261.[CrossRef][Medline] [Order article via Infotrieve]
35. Matsuura K, Takahara Y, Sudo Y, Ishida K. Extended aortic grafting for acute ascending dissection after type B dissection. Ann Thorac Cardiovasc Surg. 2001; 7: 384–386.[Medline] [Order article via Infotrieve]
36. Hata M, Sezai A, Niino T, Yoda M, Wakui S, Unosawa S, Umeda T, Shimura K, Osaka S, Furukawa N, Kimura H, Minami K. Prognosis for patients with type B acute aortic dissection: risk analysis of early death and requirement for elective surgery. Circ J. 2007; 71: 1279–1282.[CrossRef][Medline] [Order article via Infotrieve]
37. Winnerkvist A, Lockowandt U, Rasmussen E, Rådegran K. A prospective study of medically treated acute type B aortic dissection. Eur J Vasc Endovasc Surg. 2006; 32: 356–357.[CrossRef][Medline] [Order article via Infotrieve]
38. De Paepe A, Devereux RB, Dietz HC, Hennekam RC, Pyeritz RE. Revised diagnostic criteria for the Marfan syndrome. Am J Med Genet. 1996; 62: 417–426.[CrossRef][Medline] [Order article via Infotrieve]
39. Gott VL, Greene PS, Alejo DE, Cameron DE, Naftel DC, Miller DC, Gillinov AM, Laschinger JC, Pyeritz RE. Replacement of the aortic root in patients with Marfans syndrome. N Engl J Med. 1999; 340: 1307–1313.
40. Ince H, Rehders TC, Petzsch M, Kische S, Nienaber CA. Stent-grafts in patients with Marfan syndrome. J Endovasc Ther. 2005; 12: 82–88.[CrossRef][Medline] [Order article via Infotrieve]
41. D'Ancona G, Bauset R, Normand JP, Turcotte R, Dagenais F. Endovascular stent-graft repair of a complicated penetrating ulcer of the descending thoracic aorta: a word of caution. J Endovasc Ther. 2003; 10: 928–931.[CrossRef][Medline] [Order article via Infotrieve]