(Circulation. 2009;119:2225-2232.)
© 2009 American Heart Association, Inc.
Clinician Update |
From the Cardiovascular Division (G.H.M., G.C.S., M.M.G.) and Department of Medicine (S.R.W., G.H.M., G.C.S., M.M.G.), Brigham and Womens Hospital, Harvard Medical School, Boston, Mass.
Correspondence to Michael M. Givertz, MD, Cardiovascular Division, Brigham and Womens Hospital, 75 Francis St, Boston, MA 02115. E-mail mgivertz{at}partners.org
| Introduction |
|---|
|
|
|---|
Heart failure is the final pathway of a progressive disease that can originate from a variety of cardiovascular processes. Improved acute medical care and prevention of sudden cardiac death have led to an increased prevalence of advanced heart failure. The prognosis of heart failure is dismal, with 50% of patients dead within 4 years, a percentage that matches that of many common malignancies.1 Of those hospitalized with an acute exacerbation, the mortality rate within 1 year has been reported to be between 30% and 50%.2,3 Numerous factors in clinical studies consistently have been identified to be associated with poor prognosis: Advanced age, decreased blood pressure, reduced ejection fraction, chronic kidney disease, diabetes mellitus, anemia, hyponatremia, and persistently high levels of natriuretic peptides. Yet, no single clinical variable or risk score is adequate to predict outcomes in the individual patient.4,5 It is estimated that more than 100 000 patients have severe, refractory (American Heart Association/American College of Cardiology stage D) heart failure.3
Medical therapy has a major impact on the prognosis and symptoms of early heart failure, yet there are few options for care of end-stage heart disease, which primarily includes cardiac transplantation or mechanical support. The potential for cardiac transplantation remains limited, for donor supply has not changed substantially in the past decade.6 On the other hand, the technologies for VADs have expanded rapidly, and these devices may now be considered in patients with terminal heart failure. This review will discuss the unique clinical dilemmas encountered in selecting candidates for therapy with currently available VAD technology.
| Selection of a VAD Patient |
|---|
|
|
|---|
12 mL · kg–1 · min–1, or cannot be restored to New York Heart Association class III symptoms despite optimization of medical therapy (Table 1). Various composite risk scores have been devised that incorporate hemodynamic parameters and measures of end-organ function to help identify predictors of survival and guide patient selection (Table 2).10–12 Although useful in clinical decision making, none of the algorithms have been prospectively validated, and they are derived from small selected populations and are limited to specific mechanical devices.
|
|
The Interagency Registry for Mechanical Assisted Circulatory Support (INTERMACS) was initiated in 2005 to track, refine and ultimately optimize outcomes for patients who receive VADs in the United States. Sponsored by the National Institutes of Health, Center for Medicare & Medicaid Services, and the Food and Drug Administration, this nationwide registry will provide additional insights and guidelines. To help improve the assessment of implant risk, INTERMACS recently analyzed all patients who were entered during the first 18 months.13,14 A proposed series of 7 clinical profiles for patient selection was developed that better recognizes the acuity and severity of illness and may simplify the assessment of implant risk (Table 3).13,15
|
Before consideration for VAD implantation, candidates are typically evaluated at a transplant center, where they receive aggressive medical management for advanced heart disease. If patients remain refractory to standard therapy, they will be assessed and, if appropriate, listed for cardiac transplantation. The criteria for recipient selection have not changed substantially in the last 15 years.16 Three general categories of VAD patients have emerged. These include (1) individuals who require temporary circulatory support who are expected to recover after a cardiac insult and will not need cardiac transplantation (bridge to recovery); (2) patients awaiting a cardiac transplantation but who would not survive until an organ is available owing to low cardiac output and/or noncardiac comorbidities (bridge to transplantation); or (3) individuals who need long-term support but who have a relative or absolute contraindication to cardiac transplantation (destination therapy).
The distinction between bridge to transplant and destination therapy may oversimplify the potential risks of VAD, as well as the potential benefits, and may be too arbitrary in 2009. There are bridge to transplant patients who meet conventional transplant recipient criteria at the time of VAD implantation but who develop postoperative complications (eg, stroke or sepsis) that prevent further transplant consideration. There are destination therapy patients who are stabilized with VAD insertion and become suitable cardiac transplant candidates; this includes patients with secondary renal or hepatic dysfunction or reversible pulmonary hypertension. In a recent report, 17% of destination-therapy recipients underwent heart transplantation after a mean mechanical support time of 10 months.11 In addition, a small proportion (
5%) of patients with an acutely reversible process, such as fulminant myocarditis or peripartum cardiomyopathy, may be bridged to myocardial recovery and undergo successful VAD explantation.17 Hence, a more suitable designation for all potential VAD patients is "bridge to decision," for it neither raises false hopes for patients and their families nor ignores the substantial improvements in comorbidities that can be achieved with mechanical circulatory support. If a patient receives a VAD, Medicare and Medicaid, along with most insurance carriers, will cover the cost of surgery, hospitalization, and follow-up care as long as the device is approved by the Food and Drug Administration, is placed by an approved program, and is being used according to labeled instructions.
| Unique Cardiovascular and Noncardiovascular Considerations for VAD Implantation |
|---|
|
|
|---|
|
Cardiovascular Considerations
Aortic Valve Competency
The competency of the aortic valve must be assessed by echocardiography. A left VAD cannot be placed if there is aortic regurgitation, for this will simply distend the left ventricle, generating hemodynamically compromising volume overload of the VAD and inadequate forward flow. In fact, a criterion for VAD effectiveness is lack of aortic valve opening, which signals that the native ventricle has been unloaded adequately and that the VAD is providing all cardiac output. Because the aortic valve does not open, individuals with mechanical aortic valves will develop thrombus on the aortic side of the prosthesis, which can have dire embolic consequences. In rare instances of intrinsic aortic valve pathology or a bioprosthesis, the aortic valve leaflets may be oversewn to allow adequate VAD function. Pathology of the ascending aorta (eg, mobile atheromata, aneurysm, or anastomoses of patent coronary bypass grafts) may also be a contraindication to outflow cannula placement. Inspection of the aorta should be undertaken by echocardiography to assess for the presence of atheromata at the outflow cannula insertion site.
Mitral Valve Function
Under optimal VAD function, the left ventricle is a passive conduit to the VAD pumping chamber and must have unimpaired filling. Mitral stenosis should be corrected at the time of implantation, but mitral regurgitation can usually be addressed when the VAD fully decompresses the left ventricle and there is significant improvement in functional mitral regurgitation.
Right Ventricular Function
Right ventricular function is a major determinant of early postimplantation outcomes (Table 4).21–23 Because there is no current biventricular support mechanism approved for destination therapy, adequate assessment of right ventricular function is a critical preoperative variable. Indications of right-sided heart failure that may require right ventricular mechanical support include right ventricular dilation with increased end-diastolic and end-systolic volumes, marked elevation in right atrial pressure (eg,
20 mm Hg) or right atrial pressure greater than left atrial pressure, reduced right ventricular stroke work index, and severe tricuspid regurgitation.24–27 Signs of right ventricular dysfunction are further evidence that VAD placement is a "bridge to decision." At times, native right ventricular function can be supported with positive inotropic therapy, pulmonary vasodilators such as inhaled nitric oxide, and/or temporary placement of a right VAD. A risk score for predicting right-sided heart failure and need for right VAD support has been proposed recently and requires further validation.21 Isolated right ventricular failure is usually not an indication for VAD; patients with primary pulmonary hypertension are not candidates for this technology or for heart transplantation and must be considered for heart-lung or lung transplantation.
|
Intracardiac Shunts
An intracardiac shunt from a patent foramen ovale or an atrial septal defect must be identified and closed before mechanical support is instituted. After VAD implantation, the left ventricle and atrium should have normal filling pressures, and in the setting of right-sided heart failure, there can be reversal of flow, with a right-to-left shunt to the VAD provoking systemic hypoxemia.
Ischemic Heart Disease
After insertion, VAD patients may continue to experience ischemia resulting from coronary artery disease, but preservation or maximization of right ventricular function now becomes paramount. Antiischemic therapy should be optimized preoperatively and continued during mechanical circulatory support to minimize device failure or development of right-sided heart failure as a result of ischemia. Some surgeons will perform CABG to the right coronary artery if a significant stenosis exists.
Arrhythmias
Patients in atrial flutter or fibrillation may receive mechanical support, but maintenance of a sinus mechanism is preferred. Use of VADs to support refractory tachyarrhythmias has been reported. Ventricular arrhythmias that occur after implantation are generally tolerated and have not been associated with worsening hemodynamics or clinical deterioration. The defibrillator function of an implantable cardioverter defibrillator is often turned off to prevent "inappropriate" discharge. In other patients, cessation of arrhythmogenic activity may occur with adequate mechanical support and normalized hemodynamics.28,29
Noncardiovascular Considerations
Body Size
Body habitus is a critical determinant in the choice of a VAD. A body surface area of less than 1.5 m2 is probably too small to accommodate abdominal implantation of the conventional pulsatile devices. Intra-abdominal crowding may occur in smaller patients, leading to chronic abdominal discomfort, poor appetite, and nutritional impairment. In these small patients, paracorporeal devices or devices that utilize axial flow technology, such as the HeartMate II (Thoratec Corp, Pleasanton, Calif), must be considered, because they are lower-profile devices. Prior abdominal surgery must be taken into account, because adhesions or extensive procedures may preclude proper VAD placement and increase the risk of bleeding, infection, or recurrent abdominal complications. In addition, the presence of an intra-abdominal VAD limits the use of traditional noninvasive imaging techniques such as ultrasound or CT to evaluate abdominal structures.
Hepatic Function
Underlying cirrhosis and portal hypertension are associated with a poor prognosis after VAD, and any clinical evidence of liver disease should be resolved with a biopsy before implantation. Patients should be considered cautiously for an assist device if they have an alanine aminotransferase (serum glutamic pyruvic transaminase) or aspartate aminotransferase (serum glutamic-oxaloacetic transaminase) >3 times the upper limit of normal or an international normalized ratio >1.5. An elevated total bilirubin >5 mg/dL has been shown to be the strongest marker of hepatic impairment associated with mortality. After VAD insertion, reduction of pulmonary artery pressure and right ventricular afterload may improve cardiac-induced hepatic dysfunction. Despite adequate circulatory support, some individuals continue to have deterioration of hepatic function due to increased activation of proinflammatory cytokines.30 Hepatic congestion may also be a marker of impaired right ventricular function and has been related to an increased need for biventricular support.31
Renal Function
Although renal dysfunction resulting from reduced cardiac output is often reversible, it is strongly associated with poor outcomes after VAD implantation.32 An assessment should be made to determine whether renal insufficiency is secondary to poor perfusion or whether it is irreversible. A short trial of positive inotropic therapy may be indicated. Long-term dialysis patients and individuals with a creatinine level >3.0 mg/dL are at highest risk and should not be considered for support.
Pulmonary Function
Another important predictor of postimplantation morbidity and mortality is the duration of mechanical ventilation, especially in those with cardiogenic shock.33,34 All acute respiratory processes from pneumonia to a pulmonary embolus should be resolved before VAD surgery to increase the success of implantation and patient recovery. Candidates with chronic lung disease, including chronic obstructive pulmonary disease or pulmonary arterial hypertension, with a forced expiratory volume in 1 second of <1 L or pulmonary vascular resistance >3 to 4 Wood units are not eligible for a VAD.
Nutrition
Although end-stage heart failure is associated with metabolic imbalances, satisfactory preimplantation nutritional status is essential to the perioperative management of VAD patients. Cachexia, defined as a body mass index <21 kg/m2 in males and <19 kg/m2 in females, is a strong independent predictor of mortality, along with other markers of poor nutritional status, including low serum levels of albumin, prealbumin, and total protein; reduced absolute lymphocyte count; and elevated C-reactive protein.35,36 Adequate nutritional support reduces the risk of postoperative infection and improves functional recovery.37
Neoplastic Disease
A solid tumor diagnosed within the last 5 years is a relative contraindication to transplantation, but VAD therapy may allow time for definitive treatment of certain curable cancers, such as prostate or breast cancer. In many instances, patients with recent cancers may be best advised not to take immunosuppressant agents, which theoretically enhance their predisposition to recurrent neoplasm. A past history of malignancy may make destination therapy a better option, especially as the new axial flow technology evolves. However, post-VAD complications, such as stroke related to a hypercoagulable state or subclinical metastases, may be more common in patients with a history of malignancy and require further study.
Impaired Self-Care
A history of stroke, neuropathy, or musculoskeletal disease, along with other limiting diseases such as chronic obstructive pulmonary disease and obesity, needs to be evaluated carefully. Such impairments may have a greater impact on VAD candidacy than on heart transplantation. A neurological deficit with loss of hand mobility or dexterity that precludes proper operation of the VAD must be acknowledged. Irreversible cognitive impairment due to prior stroke may also preclude proper device care or management (eg, alarm recognition or hand pumping).
Social Services and Psychiatric Conditions
Psychosocial issues need to be explored before VAD surgery is recommended. As with neurological status, these issues are more important for the VAD patient than the heart transplant recipient, because the VAD patient needs a sophisticated backup system at home and in the community. These patients can never be assumed to be solely capable for their care, because issues with device malfunction need to be addressed promptly by support personnel. Before VAD implantation, patients must be screened for emotional and psychological readiness, family and social support, and home safety.10,12,38 Family members or friends should be aware that the demands on them will be great; although the long-term demands of care providers decrease with time after heart transplantation, this is not the case with VADs.
VAD patients face a unique set of challenges from the loss of independence, concern with burdening caregivers, fear of complexity of managing the device or related equipment, change in family dynamics, strain on finances, and fear of dying. This engenders a higher level of stress with family and friends, which must be taken into account in patients being considered for this technology. Patients with a recent history of tobacco, alcohol, or substance abuse should have documented abstinence for 3 to 6 months and may require home inotropic support while waiting for a transplant or a decision regarding VAD therapy.39
Perhaps more so than for any other form of therapy, consideration of VAD implantation must engender a clear understanding among the patient, family, and healthcare providers as to end-of-life issues. This technology has the ability to maintain stable hemodynamics despite difficult and unanticipated complications that the patient, family, and healthcare providers do not wish to suffer. To avoid confusion and in addition to a conventional living will, the patients and familys end-of-life desires should be documented prospectively. Such documentation should include the circumstances under which the VAD will be turned off, which would result in almost certain death.
Clinical Follow-Up
Our patient was a 57-year-old woman with end-stage ischemic/valvular cardiomyopathy who presented with refractory heart failure requiring positive inotropic support. She was listed for cardiac transplantation, had a strong family support system, and had multiple indications for mechanical circulatory support as a bridge to transplantation (Table 1). However, she also had several contraindications to VAD implantation, including small body size, mechanical aortic valve, and high surgical risk because of prior sternotomies. Given these considerations, we opted to continue medical therapy and were able to optimize hemodynamics using a pulmonary artery catheter to adjust vasoactive and diuretic therapy. She was discharged home on a continuous infusion of milrinone but was readmitted 1 day later when a suitable donor heart was identified. She underwent successful cardiac transplantation and was discharged home on postoperative day 13.
| Summary |
|---|
|
|
|---|
| Acknowledgments |
|---|
None.
| References |
|---|
|
|
|---|
2. Allen LA, Rogers JG, Warnica JW, DiSalvo TG, Tasissa G, Binanay C, O'Connor CM, Califf RM, Leier CV, Shah MR, Stevenson LW. High mortality without ESCAPE: the registry of heart failure patients receiving pulmonary artery catheters without randomization. J Card Fail. 2008; 14: 661–669.[CrossRef][Medline] [Order article via Infotrieve]
3. Rosamond W, Flegal K, Furie K, Go A, Greenlund K, Haase N, Hailpern SM, Ho M, Howard V, Kissela B, Kittner S, Lloyd-Jones D, McDermott M, Meigs J, Moy C, Nichol G, O'Donnell C, Roger V, Sorlie P, Steinberger J, Thom T, Wilson M, Hong Y. Heart disease and stroke statistics: 2008 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Circulation. 2008; 117: e25–e146.
4. Levy WC, Mozaffarian D, Linker DT, Sutradhar SC, Anker SD, Cropp AB, Anand I, Maggioni A, Burton P, Sullivan MD, Pitt B, Poole-Wilson PA, Mann DL, Packer M. The Seattle Heart Failure Model: prediction of survival in heart failure. Circulation. 2006; 113: 1424–1433.
5. Lee DS, Austin PC, Rouleau JL, Liu PP, Naimark D, Tu JV. Predicting mortality among patients hospitalized for heart failure: derivation and validation of a clinical model. JAMA. 2003; 290: 2581–2587.
6. Taylor DO, Edwards LB, Aurora P, Christie JD, Dobbels F, Kirk R, Rahmel AO, Kucheryavaya AY, Hertz MI. Registry of the International Society for Heart and Lung Transplantation: twenty-fifth official adult heart transplant report–2008. J Heart Lung Transplant. 2008; 27: 943–956.[CrossRef][Medline] [Order article via Infotrieve]
7. Medicare National Coverage Determination Manual: Chapter 1, Part 1 (Sections 10–80.12): Coverage Determination. Baltimore, Md: Centers for Medicaid & Medicare Services; 2008.
8. Rose EA, Gelijns AC, Moskowitz AJ, Heitjan DF, Stevenson LW, Dembitsky W, Long JW, Ascheim DD, Tierney AR, Levitan RG, Watson JT, Meier P, Ronan NS, Shapiro PA, Lazar RM, Miller LW, Gupta L, Frazier OH, Desvigne-Nickens P, Oz MC, Poirier VL. Long-term mechanical left ventricular assistance for end-stage heart failure. N Engl J Med. 2001; 345: 1435–1443.
9. Gronda E, Bourge RC, Costanzo MR, Deng M, Mancini D, Martinelli L, Torre-Amione G, O'Hara ML, Chambers S. Heart rhythm considerations in heart transplant candidates and considerations for ventricular assist devices: International Society for Heart and Lung Transplantation guidelines for the care of cardiac transplant candidates–2006. J Heart Lung Transplant. 2006; 25: 1043–1056.[CrossRef][Medline] [Order article via Infotrieve]
10. Oz MC, Goldstein DJ, Pepino P, Weinberg AD, Thompson SM, Catanese KA, Vargo RL, McCarthy PM, Rose EA, Levin HR. Screening scale predicts patients successfully receiving long-term implantable left ventricular assist devices. Circulation. 1995; 92 (suppl II): II-169–II-173.
11. Lietz K, Long JW, Kfoury AG, Slaughter MS, Silver MA, Milano CA, Rogers JG, Naka Y, Mancini D, Miller LW. Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: implications for patient selection. Circulation. 2007; 116: 497–505.
12. Deng MC, Loebe M, El Banayosy A, Gronda E, Jansen PG, Vigano M, Wieselthaler GM, Reichart B, Vitali E, Pavie A, Mesana T, Loisance DY, Wheeldon DR, Portner PM. Mechanical circulatory support for advanced heart failure: effect of patient selection on outcome. Circulation. 2001; 103: 231–237.
13. Kirklin JK, Naftel DC, Stevenson LW, Kormos RL, Pagani FD, Miller MA, Ulisney K, Young JB. INTERMACS database for durable devices for circulatory support: first annual report. J Heart Lung Transplant. 2008; 27: 1065–1072.[CrossRef][Medline] [Order article via Infotrieve]
14. Kirklin JK, Naftel DC. Mechanical circulatory support: registering a therapy in evolution. Circ Heart Fail. 2008; 1: 200–205.
15. Stevenson LW, Couper G. On the fledgling field of mechanical circulatory support. J Am Coll Cardiol. 2007; 50: 748–751.
16. Mudge GH, Goldstein S, Addonizio LJ, Caplan A, Mancini D, Levine TB, Ritsch ME, Stevenson LW. Task Force 3: recipient guidelines/prioritization, in 24th Bethesda Conference: cardiac transplantation. J Am Coll Cardiol. 1993; 22: 21–31.[Medline] [Order article via Infotrieve]
17. Mancini DM, Beniaminovitz A, Levin H, Catanese K, Flannery M, DiTullio M, Savin S, Cordisco ME, Rose E, Oz M. Low incidence of myocardial recovery after left ventricular assist device implantation in patients with chronic heart failure. Circulation. 1998; 98: 2383–2389.
18. Miller LW. Patient selection for the use of ventricular assist devices as a bridge to transplantation. Ann Thorac Surg. 2003; 75 (suppl): S66–S71.
19. Cimato TR, Jessup M. Recipient selection in cardiac transplantation: contraindications and risk factors for mortality. J Heart Lung Transplant. 2002; 21: 1161–1173.[CrossRef][Medline] [Order article via Infotrieve]
20. Mudge GH Jr, Fang JC, Smith C, Couper G. The physiologic basis for the management of ventricular assist devices. Clin Cardiol. 2006; 29: 285–289.[CrossRef][Medline] [Order article via Infotrieve]
21. Matthews JC, Koelling TM, Pagani FD, Aaronson KD. The right ventricular failure risk score: a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates. J Am Coll Cardiol. 2008; 51: 2163–2172.
22. Dang NC, Topkara VK, Mercando M, Kay J, Kruger KH, Aboodi MS, Oz MC, Naka Y. Right heart failure after left ventricular assist device implantation in patients with chronic congestive heart failure. J Heart Lung Transplant. 2006; 25: 1–6.[CrossRef][Medline] [Order article via Infotrieve]
23. Deng MC, Edwards LB, Hertz MI, Rowe AW, Keck BM, Kormos R, Naftel DC, Kirklin JK, Taylor DO. Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: third annual report–2005. J Heart Lung Transplant. 2005; 24: 1182–1187.[CrossRef][Medline] [Order article via Infotrieve]
24. Ochiai Y, McCarthy PM, Smedira NG, Banbury MK, Navia JL, Feng J, Hsu AP, Yeager ML, Buda T, Hoercher KJ, Howard MW, Takagaki M, Doi K, Fukamachi K. Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: analysis of 245 patients. Circulation. 2002; 106 (suppl I): I-198–I-202.
25. Nakatani S, Thomas JD, Savage RM, Vargo RL, Smedira NG, McCarthy PM. Prediction of right ventricular dysfunction after left ventricular assist device implantation. Circulation. 1996; 94 (suppl II): II-216–II-221.
26. Fukamachi K, McCarthy PM, Smedira NG, Vargo RL, Starling RC, Young JB. Preoperative risk factors for right ventricular failure after implantable left ventricular assist device insertion. Ann Thorac Surg. 1999; 68: 2181–2184.
27. Potapov EV, Stepanenko A, Dandel M, Kukucka M, Lehmkuhl HB, Weng Y, Hennig F, Krabatsch T, Hetzer R. Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device. J Heart Lung Transplant. 2008; 27: 1275–1281.[CrossRef][Medline] [Order article via Infotrieve]
28. Oz MC, Rose EA, Slater J, Kuiper JJ, Catanese KA, Levin HR. Malignant ventricular arrhythmias are well tolerated in patients receiving long-term left ventricular assist devices. J Am Coll Cardiol. 1994; 24: 1688–1691.[Abstract]
29. Ziv O, Dizon J, Thosani A, Naka Y, Magnano AR, Garan H. Effects of left ventricular assist device therapy on ventricular arrhythmias. J Am Coll Cardiol. 2005; 45: 1428–1434.
30. Masai T, Sawa Y, Ohtake S, Nishida T, Nishimura M, Fukushima N, Yamaguchi T, Matsuda H. Hepatic dysfunction after left ventricular mechanical assist in patients with end-stage heart failure: role of inflammatory response and hepatic microcirculation. Ann Thorac Surg. 2002; 73: 549–555.
31. Reinhartz O, Farrar DJ, Hershon JH, Avery GJ Jr, Haeusslein EA, Hill JD. Importance of preoperative liver function as a predictor of survival in patients supported with Thoratec ventricular assist devices as a bridge to transplantation. J Thorac Cardiovasc Surg. 1998; 116: 633–640.
32. Butler J, Geisberg C, Howser R, Portner PM, Rogers JG, Deng MC, Pierson RN III. Relationship between renal function and left ventricular assist device use. Ann Thorac Surg. 2006; 81: 1745–1751.
33. Rao V, Oz MC, Flannery MA, Catanese KA, Argenziano M, Naka Y. Revised screening scale to predict survival after insertion of a left ventricular assist device. J Thorac Cardiovasc Surg. 2003; 125: 855–862.
34. El Banayosy A, Arusoglu L, Kizner L, Tenderich G, Boethig D, Minami K, Korfer R. Predictors of survival in patients bridged to transplantation with the Thoratec VAD device: a single-center retrospective study on more than 100 patients. J Heart Lung Transplant. 2000; 19: 964–968.[CrossRef][Medline] [Order article via Infotrieve]
35. Anker SD, Chua TP, Ponikowski P, Harrington D, Swan JW, Kox WJ, Poole-Wilson PA, Coats AJ. Hormonal changes and catabolic/anabolic imbalance in chronic heart failure and their importance for cardiac cachexia. Circulation. 1997; 96: 526–534.
36. Dang NC, Topkara VK, Kim BT, Lee BJ, Remoli R, Naka Y. Nutritional status in patients on left ventricular assist device support. J Thorac Cardiovasc Surg. 2005; 130: e3–e4.
37. Holdy K, Dembitsky W, Eaton LL, Chillcott S, Stahovich M, Rasmusson B, Pagani F. Nutrition assessment and management of left ventricular assist device patients. J Heart Lung Transplant. 2005; 24: 1690–1696.[CrossRef][Medline] [Order article via Infotrieve]
38. Mielniczuk L, Mussivand T, Davies R, Mesana TG, Masters RG, Hendry PJ, Keon WJ, Haddad HA. Patient selection for left ventricular assist devices. Artif Organs. 2004; 28: 152–157.[CrossRef][Medline] [Order article via Infotrieve]
39. Dew MA, DiMartini AF, Steel J, De Vito DA, Myaskovsky L, Unruh M, Greenhouse J. Meta-analysis of risk for relapse to substance use after transplantation of the liver or other solid organs. Liver Transpl. 2008; 14: 159–172.[CrossRef][Medline] [Order article via Infotrieve]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2009 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |