Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2008;118:586-606
Published online before print June 27, 2008, doi: 10.1161/CIRCULATIONAHA.108.189695
Free Article
This Article
Free upon publication Free Article
Right arrow Extract
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
118/5/586    most recent
CIRCULATIONAHA.108.189695v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bluemke, D. A.
Right arrow Articles by Woodard, P. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bluemke, D. A.
Right arrow Articles by Woodard, P. K.
Related Collections
Right arrow AHA Statements and Guidelines

(Circulation. 2008;118:586-606.)
© 2008 American Heart Association, Inc.


AHA Scientific Statement

Noninvasive Coronary Artery Imaging

Magnetic Resonance Angiography and Multidetector Computed Tomography Angiography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention, and the Councils on Clinical Cardiology and Cardiovascular Disease in the Young

David A. Bluemke, MD, PhD, FAHA, Chair; Stephan Achenbach, MD; Matthew Budoff, MD, FAHA; Thomas C. Gerber, MD, FAHA; Bernard Gersh, DPhil, MD, FAHA; L. David Hillis, MD; W. Gregory Hundley, MD, FAHA; Warren J. Manning, MD, FAHA; Beth Feller Printz, MD, PhD; Matthias Stuber, PhD; Pamela K. Woodard, MD, FAHA


Key Words: AHA Scientific Statements • angiography • imaging


*    Introduction
up arrowTop
*Introduction
down arrowMRA of the Coronary...
down arrowClinical Applications and...
down arrowLimitations of Coronary CTA...
down arrowFuture Directions in Noninvasive...
down arrowSummary and Recommendations
down arrowReferences
 
Since the early 1960s, selective x-ray coronary angiography has provided the only means of visualizing the coronary arterial system in vivo. However, it has several disadvantages. First, the incidence, albeit relatively low, of so-called major adverse events (death, myocardial infarction, or stroke) during or within 24 hours of selective coronary angiography is reported to be 0.2% to 0.3%, and the incidence of so-called minor complications (most of which are related to problems with the peripheral vessels through which catheters are inserted) is roughly 1% to 2%.1–3 Second, x-ray coronary angiography is accompanied by a modest amount of discomfort, because the placement of catheters is invasive. Third, it is expensive: the required equipment is costly, and the performance of the procedure necessitates considerable time and skill of highly trained physicians and support personnel. Last, the information obtained via catheter-based coronary angiography pertains to the coronary arterial lumen alone. As a result, alternative methods of visualizing the coronary arterial system that would allow one to avoid these disadvantages are desirable.

Over the past 15 years, substantial advances have been made in noninvasive cardiac imaging in general and in visualization of the coronary arteries in particular. Magnetic resonance angiography (MRA) of the coronary arteries was advanced in the early 1990s with the development of high-speed gradient techniques and dedicated cardiac coils. The primary advantage of this technique is the patient’s lack of exposure to ionizing radiation or iodinated contrast media. Coronary MRA may also be combined with other magnetic resonance (MR) imaging techniques for assessment of cardiac function, structure, blood flow, and viability.4

Electron-beam computed tomography (CT) with iodinated contrast injection was originally used to perform coronary angiograms, but this has been supplanted by multidetector CT (MDCT) scanners that have 16 to 256 rows of detectors. MDCT can provide visually compelling images of the coronary arterial tree, although at present, the necessary radiation dose is higher than that associated with x-ray coronary angiography.

In this statement, we discuss and summarize these two noninvasive modalities, MRA and computed tomographic angiography (CTA), which may be used for coronary artery evaluation. Because the advantages and limitations of CT to assess the presence and extent of coronary arterial calcification are discussed in a separate document sponsored by the American Heart Association, the assessment of coronary arterial calcification is not presented in this statement. For both MRA and CTA, we provide a discussion of technical issues, applications, advantages, and limitations, after which we offer recommendations for current and future uses. To accomplish this, the Writing Committee conducted a comprehensive review of the literature published between 1990 and 2006. Literature searches of the PubMed/MEDLINE databases were undertaken to identify pertinent articles. Searches were limited to the English language. The major search terms included the following: coronary angiography, coronary disease, coronary vessels, humans, magnetic resonance angiography, tomography, and x-ray computed.


*    MRA of the Coronary Arteries
up arrowTop
up arrowIntroduction
*MRA of the Coronary...
down arrowClinical Applications and...
down arrowLimitations of Coronary CTA...
down arrowFuture Directions in Noninvasive...
down arrowSummary and Recommendations
down arrowReferences
 
Technical Considerations for Coronary MRA
Images of the heart must be obtained rapidly and with high temporal resolution to reduce motion artifacts that could otherwise cause blurring in coronary MRA images. Unlike angiographic images obtained via catheter, MRA (and CTA) images take a long time to acquire; for example, high-resolution MRA visualization of the entire coronary arterial tree takes minutes rather than seconds. In addition, cardiac motion must be accounted for during this time period.

Cardiac Motion
Two sources of motion are associated with coronary MRA: motion related to intrinsic cardiac contraction/relaxation and motion attributable to superimposed diaphragm and chest wall movement during respiration. Because the extent of motion exceeds the diameter of the coronary artery, blurring artifacts of the coronary artery lumen will occur unless adequate motion-suppression techniques are applied. ECG gating is used to account for intrinsic cardiac motion.

Coronary artery motion occurs in a triphasic pattern during the cardiac cycle. Mid-diastole is the preferred time for image acquisition, because cardiac motion is minimized while coronary flow is high. The patient-specific diastasis period (of reduced coronary motion) is usually determined by visual inspection of cine images perpendicular to the long axis of the proximal/mid-right coronary artery (RCA). Multiple heartbeats are required to generate a coronary MRA. The beat-to-beat variation in the duration of the cardiac cycle and the period of diastasis results in image blurring. β-Blockade prolongs the period of coronary diastasis and may help to improve the quality of coronary MRA images.

Respiratory Motion
A straightforward approach to suppressing respiratory motion involves the use of breath-holding during coronary MRA. However, breath-holding strategies have several limitations. First, spatial and temporal image resolution is limited by the patient’s ability to hold his or her breath. Some patients may have difficulty sustaining adequate breath-holds, particularly when the procedure lasts longer than a few seconds. Additionally, it has been shown that during a sustained breath-hold, there is up to 1 cm of cranial diaphragmatic (and thus cardiac) drift.5–7 Thus, at present, breath-hold strategies for coronary MRA have limited applicability to the broad range of patients with cardiovascular disease.

To overcome these limitations, so-called navigator echoes8–11 (similar to M-mode echocardiographic beams) can be used during free-breathing coronary MRA to track a patient’s diaphragmatic motion. MRA images are acquired only when the diaphragm is within 3 to 5 mm of its end-expiratory position. Respiratory blurring is minimized with this method and may be further reduced by using real-time tracking of the imaged volume position.9

Free-breathing navigator coronary MRA offers improved patient comfort as compared with breath-holding techniques and does not require significant patient motivation. However, this method prolongs the duration of the coronary MRA, because image data are collected only when the end-expiratory position of the diaphragm coincides with the period of coronary artery diastasis.12 Typical examination times for free-breathing 3D navigator coronary MRA are 7 to 15 minutes.

Spatial Resolution
The spatial resolution achievable with 3D MRA imaging (0.7 to 0.8 mm in-plane resolution and 1 to 3 mm through-plane resolution) is inferior to that obtainable with x-ray coronary angiography (<0.3 mm).

For MRA imaging, improvement in spatial resolution is generally accompanied by reduction in the signal-to-noise ratio (SNR). As the voxel size is reduced toward the resolution achievable with x-ray angiography, methods to reduce motion artifacts from both intrinsic and extrinsic motion of the coronary arteries become increasingly important.13

Contrast Enhancement in Coronary MRA
Coronary MRA examinations are typically performed without the addition of intravenously administered contrast agents. The relative signal of the coronary arteries is augmented using fat-saturation prepulses,14 magnetization transfer contrast prepulses,15 or T2 preparatory pulses,16,17 which take advantage of natural T2 differences between the blood and the surrounding myocardium. When these techniques are used, the coronary lumen appears bright, whereas the surrounding myocardium has reduced signal intensity. The lack of exposure to ionizing radiation and the absence of exogenous contrast agents facilitate repeat MRA studies when clinically warranted.

With the use of intravenous MR contrast agents, the T1 relaxation time for blood can be shortened, which allows for an increased contrast-to-noise ratio for coronary MRA.18,19 The extravascular contrast agents that are presently available in the United States for coronary MRA quickly extravasate from the coronary lumen. Use of these agents requires rapid first-pass imaging, which necessitates breath-holding20 and results in images with reduced spatial resolution (as discussed in Spatial Resolution, above).

Recent Technical Developments
Technical improvements in coronary MRA include the development of MR methods that generate improved coronary signals and support reduced scanning times while simultaneously minimizing the complexity of the examination.

Steady-State With Free-Precession Coronary MRA
Use of the steady-state with free-precession (SSFP) method to perform MRA makes it possible to obtain high signal intensity from the coronary arteries and very high contrast between the ventricular blood pool and the myocardium without the need for contrast agents.21 SSFP imaging permits high-quality coronary MRA during free-breathing with substantial improvements in SNR, contrast-to-noise ratio, and vessel sharpness as compared with standard T2-prepared gradient-echo imaging.22 Therefore, SSFP imaging may lead to improved identification of significant coronary artery stenoses. At present, SSFP is being evaluated at many clinical and research centers.

Phase-Contrast MR Imaging
The phase-contrast technique measures blood-flow velocity23 combined with arterial diameter to yield a quantitative measurement of blood flow (in milliliters per minute). Blood flow can be determined when a patient is at rest or after he or she is stressed for measurement of coronary artery blood-flow reserve.23,24 Although it has been demonstrated in clinical research, this method can be applied on most 1.5-Tesla and some 3.0-Tesla MR scanners. Coronary blood flow is measured along a 2-cm straight proximal or mid-arterial segment in vessels that are >2 mm in diameter.25

Parallel Imaging for Coronary MRA
Parallel imaging is an MR method for reducing MR scanning time by a factor of 2 to 3.26 However, the trade-off for reduced acquisition time is reduced SNR for visualization of the coronary arteries.

3-Tesla Coronary MRA
Most coronary MRA examinations are performed on 1.5-Tesla MR systems. Higher field, 3-Tesla systems provide better signal and contrast values relative to 1.5-Tesla systems. The recent availability of 3-Tesla systems equipped with dedicated cardiac hardware (eg, real-time spectrometer, parallel receiver technology with high bandwidth, body radiofrequency send coil, vector ECG) and software (parallel imaging, navigators, interactive interface) may provide a means for substantial coronary MRA improvements in the future.27

Whole-Heart Coronary MRA
Until recently, coronary MRA was performed with only portions of each arterial tree visible in each set of images.28 This method requires the MR imaging technologist to have extensive experience and familiarity with coronary artery anatomy. The recent development of whole-heart coronary MRA, which is analogous to coronary CTA, allows for imaging of the entire coronary artery tree in an axially acquired 3D volume. Postprocessing of the 3D images is performed in a manner similar to that for coronary CTA. To collect such large volumetric data sets, spatial resolution is somewhat lower (usually >1 mm in-plane and through-plane resolution), data are collected over approximately 100 ms of each cardiac cycle (with potential for blurring), and scan times are lengthy (10 to 15 minutes), thereby mandating the use of navigator echoes. Nevertheless, the whole-heart coronary MRA approach has gained rapid acceptance on the basis of promising initial results.29


*    Clinical Applications and Results
up arrowTop
up arrowIntroduction
up arrowMRA of the Coronary...
*Clinical Applications and...
down arrowLimitations of Coronary CTA...
down arrowFuture Directions in Noninvasive...
down arrowSummary and Recommendations
down arrowReferences
 
Anomalous Coronary Artery
Projection x-ray angiography has traditionally been the imaging test of choice for the diagnosis and characterization of coronary artery anomalies. However, the presence of an anomalous coronary artery origin is sometimes only suspected after the invasive procedure, particularly in the case of unsuccessful engagement or visualization of a coronary artery. In addition, the declining use of pulmonary artery catheters during routine x-ray coronary angiography has made it more difficult to discern the anterior versus the posterior trajectory of the anomalous vessels.

Multiple published series exist30–33 of patients who underwent blinded comparison of coronary MRA with x-ray angiography (Table 1). Early coronary MRA studies often used a 2D breath-hold ECG-triggered segmented k-space gradient-echo approach.30–36 These 2D coronary MRA studies uniformly reported excellent accuracy, including several studies in which coronary MRA was determined to be superior to x-ray angiography.31,32 At most centers, 3D coronary MRA is now used, because it offers superior reconstruction capabilities with similarly excellent results.37 For these reasons, coronary MRA is the preferred test for younger patients in whom an anomalous artery origin is suspected or a known anomalous coronary artery origin needs to be clarified and for patients who have another cardiac anomaly associated with coronary anomalies (eg, tetralogy of Fallot).


View this table:
[in this window]
[in a new window]

 
Table 1. Coronary MRA for Anomalous Coronary Artery Evaluation

Coronary Artery Aneurysms/Kawasaki Disease
Although coronary artery aneurysms are relatively uncommon, recent studies indicate an important role for coronary MRA for assessment of this condition. The vast majority of acquired coronary aneurysms in children and younger adults are due to Kawasaki disease, a generalized vasculitis of unknown etiology that usually occurs in children under 5 years old. Approximately 5% of patients develop coronary artery ectasia or aneurysms despite appropriate therapy.38–40 Good correlation between coronary MRA and x-ray coronary angiography has also been reported for ectatic coronary arteries (distinct from Kawasaki disease) among adults.41

Coronary MRA for Identification of Native Vessel Coronary Stenoses
The results of coronary MRA in single-center trials are presented in Table 2. No efficacy data have been reported regarding "screening" coronary MRA in high-risk populations.


View this table:
[in this window]
[in a new window]

 
Table 2. MRA for the Detection of Coronary Artery Stenosis

A multicenter single-vendor study of 3D coronary MRA in 109 patients demonstrated 93% sensitivity, 58% specificity, and 81% negative predictive value for the identification of greater double equals50% diameter stenosis by quantitative coronary angiography (Table 3).28 The sensitivity and negative predictive value were particularly high for the identification of left-main or multivessel disease, thereby demonstrating a role for coronary MRA for this subset. Accordingly, coronary MRA may be valuable for rendering a diagnosis for patients who present with dilated cardiomyopathy/congestive heart failure in the absence of clinical infarction and for determining whether the problem is ischemic or nonischemic. A limitation of this study for general application of the results was the use of MR scanners from the same vendor at all sites.


View this table:
[in this window]
[in a new window]

 
Table 3. Three-Dimensional Navigator Coronary MRI: Multicenter Trial Results

Single-center data obtained from using free-breathing navigator-gated whole-heart MRA suggest that the whole-heart approach provides faster acquisitions (<15 minutes) and superior accuracy,29,42–46 with sensitivities of 80% to 90% and specificity of >90%. Two comparison studies of coronary MRA and 16-slice MDCT demonstrated similar accuracy when compared with free-breathing coronary MRA47 and superior results for MDCT when compared with a combination of free-breathing and lower-resolution breath-hold coronary MRA.48

At experienced research centers, phase-contrast MR coronary artery flow measurements can provide supplemental information regarding the physiological importance of coronary artery luminal narrowing.49–54 Impaired coronary flow reserve measured by MR identifies coronary arterial luminal stenosis of >70% in the left-main and proximal coronary artery segments when the angiographic appearance of the stenosis is of intermediate severity.49–51 In individuals who have undergone percutaneous coronary artery stent placement in the left anterior descending coronary artery, impaired phase-contrast MR flow-reserve measurements reliably identify luminal renarrowing of >50% for symptomatic patients 3 months or more after stent implantation.52,55

The results discussed above were obtained at research-oriented centers that have the capability to perform high-quality MRCA in either single-center or single-vendor trials. The utility of coronary MRA in general practice has not been established, and multivendor trials have not been conducted.

Coronary MRA for Coronary Artery Bypass Graft Assessment
Conventional free-breathing ECG-gated 2D spin-echo MRA56–59 and 2D gradient-echo MRA60–63 in the transverse plane have both been used with knowledge of the origin and touchdown site of each graft to reliably assess bypass graft patency (Table 4). Additionally, both 3D noncontrast64 and contrast-enhanced coronary MRA have been used for assessment of graft patency,65,66 with slightly improved results. The accuracy of ECG-gated SSFP sequences appears to be similar to that of spin-echo and gradient-echo approaches.67


View this table:
[in this window]
[in a new window]

 
Table 4. Evaluation of Coronary Artery Bypass Graft Patency by Coronary MRA

A practical limitation of coronary MRA bypass graft assessment is related to local signal loss and artifacts that are caused by nearby metallic objects (hemostatic clips, ostial stainless steel graft markers, sternal wires, coexistent prosthetic valves and supporting struts or rings, and graft stents). Although coronary MRA has been successfully used for identification of graft occlusion, the inability to identify various degrees of luminal narrowing in diseased yet patent grafts is also a hindrance to clinical utility and acceptance.

CTA of the Coronary Arteries
CTA Techniques and Technical Issues
Because of the high motion velocity of the coronary arteries, CT scanners must have sufficiently high temporal resolution to provide images of the beating heart with minimal motion artifact. Depending on the patient’s heart rate during the scan and the phase of the cardiac cycle at which the coronary arteries are captured, a temporal resolution of 19 to 75 ms is desirable for coronary CTA.68,69 Similar to coronary MRA, coronary CTA temporal resolution is currently lower than is optimal for coronary artery depiction.

Multidetector Computed Tomography
MDCT scanners (also known as multislice CT) with x-ray tubes rotating fast enough to allow coronary artery imaging (500 ms or less per rotation) became available in the late 1990s.70,71 The temporal resolution of MDCT is approximately half the time it takes for the x-ray gantry to complete a 360° rotation around the patient when a half-segment reconstruction is used. The nominal temporal resolution can be improved by a factor of 2 to 3 (depending on the heart rate) by segmented reconstruction techniques that combine projection data acquired during 2 or more cardiac cycles into 1 image.70,72 Currently, MDCT scanners can acquire up to 64 slices simultaneously with a maximum temporal resolution as low as 83 ms (dual-source MDCT).73

In MDCT coronary CTA, image data are acquired throughout the cardiac cycle while the patient table continuously advances through the gantry. Electrocardiographic information is used to retrospectively reconstruct images from projection data acquired during the phase of the cardiac cycle with the least cardiac motion. The speed of the patient table relative to the speed of the gantry rotation (called pitch) is such that each cross-sectional level of the heart is imaged during more than 1 cardiac cycle. The number of image slices acquired during each gantry rotation (currently ranging from 16 to 320) determines the overall duration of the MDCT scan but does not directly influence the temporal resolution.

Spatial Resolution
The smallest x-ray beam collimation possible with a given CT scanner dictates the minimal thickness of the image slices that can be reconstructed. The slice thickness affects spatial resolution. High spatial resolution allows assessment of small side branches of the coronary arteries, decreases artifacts due to partial-volume effects, and leads to better assessment of calcified coronary artery segments and in-stent stenoses. However, to have sufficiently low image noise with smaller x-ray beam collimation, a large increase of the x-ray dose is necessary.

Spatial resolution has improved with each advance in MDCT technology. Submillimeter resolution has been achieved in MDCT scanners ranging from 16 to 320 slices. The spatial resolution of the present 64-slice MDCT scanners is {approx}0.4 mm.74 This is an improvement over the 0.7-mm resolution of 16-slice MDCT but not as high as can be obtained with catheter-based cine angiography (<0.3 mm).

Contrast Medium Administration
Coronary CTA requires intravenous administration of an iodinated contrast medium. Power injectors are programmed to administer 50 to 160 mL of iodinated contrast medium at a rate of 4 to 6 mL/s through a cannula designed for this injection rate (typically 18 gauge or greater) that is usually placed in an antecubital vein. Accurate timing of the CT scan relative to the start of the contrast injection is the major determinant of overall image quality and enhancement of the coronary arteries. To optimize this timing, a test bolus of 10 to 20 mL of contrast medium can be injected to measure the time to peak enhancement of the aortic root; this time period is then programmed into the MDCT scanner when the coronary CTA is performed. Alternatively, the CT scanner can be set to automatically initiate scanning when the enhancement of the aortic root exceeds a predetermined threshold.

The volume of intravenous contrast medium required for coronary CTA is proportional to the injection rate chosen and the duration of the CT scan. Approximately 60 to 100 mL of contrast medium is injected for coronary CTA with present MDCT scanners.

Pharmacological Patient Preparation
Because of the limited temporal resolution of MDCT scanners, low heart rates are desirable to avoid motion artifacts.75–78 Several studies have convincingly shown that lowering the heart rate to 60 beats per minute or less by oral administration of β-receptor blocking agents 60 to 90 minutes before the scan, or intravenous administration immediately before the scan, or both, can decrease the frequency and extent of motion artifacts on the coronary CTA scan75,79 by prolonging the rest period (the time during the cardiac cycle at which coronary artery velocity is low).80 Image quality on lower temporal resolution MDCT scanners reveals the greater benefit of lower heart rates. For example, for scanners with a temporal resolution of ≥250 ms, a heart rate of <60 beats per minute is needed to minimize coronary motion artifacts.75,79 For scanners with a temporal resolution of at least 167 ms, a heart rate of ≤75 beats per minute results in acceptable image quality.81 For new dual-source CT scanners, acceptable image quality of the coronary arteries has been obtained at up to 90 beats per minute.82 Therefore, pharmacological heart-rate control may not be necessary for many of the patients who undergo coronary CTA on dual-source scanners.

Some investigators and practitioners of coronary CTA administer sublingual nitroglycerin immediately before the scan to achieve vasodilatation.83 The use of nitroglycerin has been shown to improve image quality in one small study performed using 16-slice MDCT.83

Radiation Dose
Coronary CTA can expose a patient to considerably higher amounts of ionizing radiation than standard radiographs, CT calcium scoring, or x-ray angiography.84 The reasons for the higher radiation dose are that continuous x-ray irradiation occurs during the entire 8- to 20-second MDCT scan, and this is coupled with overlapping slices and specific requirements for x-ray tube current and voltage. To maintain low levels of image noise and thus high image quality, x-ray tube current (mA) and tube voltage (kVp) must be increased with increasing patient body size or decreasing slice thickness or scan time. For a given slice thickness, radiation dose increases linearly with tube current and by the square of the ratio between the original and increased tube voltage setting.85

The radiation doses for coronary CTA reported in the literature vary, mostly because of technical differences between scanner generations (eg, 16 versus 64 slice) and between scanners from various manufacturers. The most meaningful parameters of CT dosimetry are the volume CT dose index (CTDIvol) and the effective dose (E). The CTDIvol, expressed in SI units of milliGray (mGy),86 represents the average radiation dose over the center slice of a CT scan and is useful for comparing absorbed radiation doses from different CT scanning protocols. The CTDIvol value increases with decreasing pitch (defined as the patient-table advance relative to the width of all simultaneously acquired slices and not relative to the width of a single slice). The CTDIvol is typically displayed on the CT scanner console once an imaging protocol has been loaded. E is the radiation dose parameter most frequently reported in the coronary CTA literature and is expressed in SI units of milliSievert (mSv).87,88 E cannot be measured but is a rough estimate of the biological risk of a partial body exposure relative to an equivalent whole-body radiation exposure. E is typically used to analyze population dose rather than individual patient dose. The use of E allows comparisons between the biological effects of exposure to ionizing radiation from various sources and is not limited to medical imaging. There are several techniques for estimating E, and these are generally in good agreement.87,88 Some models report a gender-specific E, whereas others average radiation doses between both genders. At present, the way that effective dose quantitatively translates into a lifetime risk of malignancies in subjects exposed to ionizing radiation is a controversial topic.89

In general, radiation dose increases with increasing number and thinner collimation of slices acquired simultaneously during each gantry rotation, because of detector inefficiency in the presence of a broader x-ray beam and higher photon requirements to keep image noise constant if slice thickness is reduced. E values for vendor-recommended MDCT coronary angiography scanning protocols range from 10.9 mSv for male patients and 13.0 mSv for female patients with use of a 4-slice scanner90 to 13.0 mSv averaged between male and female patients with a 16-slice scanner.85 For comparison, an individual receives an {approx}3 mSv radiation dose each year from natural background radiation,91 0.05 mSv for a chest x-ray, and {approx}5 to 6 mSv for a diagnostic x-ray coronary angiogram.92 With present technology, use of MDCT coronary CTA in a population that is at very low risk for coronary artery disease is inappropriate, because the risk associated with the radiation exposure may exceed the potential benefit of the CTA.93

Radiation dose from coronary CTA can be reduced by using several techniques, not all of which are available on every MDCT scanner on the market. One technique, termed ECG-controlled tube-current modulation, decreases x-ray tube current during systole. Because coronary CTA images are typically reconstructed from data acquired during diastole, image quality is maintained particularly for lower heart rates.94–96 ECG-controlled tube-current modulation decreases radiation dose by 25% to 45%, depending on the patient’s heart rate during the scan.85,94,95,97 A second method for radiation dose reduction is to reduce the x-ray tube current while scanning in the anterior-posterior plane compared with when scanning through the lateral plane.98,99

In recent clinical studies of 64-slice MDCT coronary CTA, E has ranged from {approx}10 to 14 mSv with ECG-triggered tube-current modulation100 to 13 to 15 mSv for men and 18 to 21 mSv for women without tube-current modulation.101,102 In a study of 1035 patients undergoing coronary CTA with tube-current modulation, radiation dose estimates were 6±2 and 11±4 mSv for 16- and 64-slice CTA, respectively.103 Using higher pitch and greater time per cardiac cycle during which tube current is reduced by tube-current modulation may substantially reduce the radiation dose received from coronary CTA with dual-source CT scanners.73

CTA Applications
Anomalous Coronary Artery
Multiple published series exist104–109 of patients who underwent comparison of coronary CTA data with x-ray angiography (Table 5) for anomalous coronary artery evaluation. The assessment of anomalous coronary origin via cardiac CT has been shown to be accurate110–112 and of benefit in detecting and characterizing anomalous coronary artery compared with x-ray angiography.106


View this table:
[in this window]
[in a new window]

 
Table 5. Coronary CTA for Anomalous Coronary Artery Evaluation

Coronary CTA for Identification of Native Vessel Coronary Stenoses
The feasibility of coronary CTA was initially demonstrated with 4-slice MDCT.52,63,97–106 However, image evaluation was impaired in many cases owing to limited spatial and temporal resolution. With the introduction of 16-slice MDCT, image quality in coronary CTA has become more consistent. The minimal technical prerequisite for contrast-enhanced MDCT coronary CTA is 16-slice technology with a gantry rotation time of <500 ms and slice collimation of <1.0 mm. Several studies have been published that demonstrated substantially improved image quality over previous scanner generations113 and generally improved accuracy for the detection of coronary artery stenoses (sensitivity of 30% to 98% and specificity of 86% to 98%, Table 6Down).97,114–127 Studies that used 16-slice acquisition and rotation times of <400 ms have reported sensitivities between 83% and 98% as well as specificities between 96% and 98%.117,121–127


View this table:
[in this window]
[in a new window]

 
Table 6. CTA for the Detection of Coronary Artery Stenosis


View this table:
[in this window]
[in a new window]

 
Table 6. Continued

Shorter examination times are possible with 64-slice MDCT; these scanners also frequently incorporate improved temporal and spatial resolution compared with 16-slice MDCT. To date, the sensitivity and specificity of MDCT studies range from 73% to 100% and 91% to 97%,100–102,128–131 respectively (Table 6Up). Meta-analyses of 64-slice MDCT studies arrived at sensitivities of 93% and specificity of 96%132 (in 6 studies) and sensitivities of 86% and specificity of 96%133 (in 19 studies).

Studies to evaluate the accuracy of coronary CTA for stenosis detection have been limited by relatively small patient groups. In early studies, patients were excluded from enrollment (eg, patients with arrhythmias); also, non-evaluable segments were often excluded from analysis. These exclusions limit the applicability of the reported results to the clinical situation.

Detection of in-stent restenosis has been challenging with 16-slice MDCT, because artifacts caused by stent material frequently preclude adequate visualization of the stent lumen. In 5 small studies that compared coronary CTA to invasive angiography, sensitivity for detection of in-stent restenosis by 16- and 40-slice MDCT was 54% to 100%.134,135 Up to 49% of stents were not evaluable.135–139 One study that assessed only stents implanted in the left main coronary artery (mean stent diameter 3.9 mm) found 4 of 4 stent restenoses.134 A recent study performed by 64-slice CT in 64 patients with 102 stents demonstrated that only 58% of stents were evaluable by CT. In evaluable stents, sensitivity and specificity for detection of in-stent stenosis was 86% and 98%.140 However, in this and other studies, a substantial influence of stent size and material, as well as of CT system specifications and image acquisition and reconstruction protocols used on stent visibility has been documented.141–144 Thus, routine assessment of coronary stents has not been shown to be reliable with present technology.

The presence of hemodynamically relevant coronary artery stenoses in patients without stents and bypass grafts may be ruled out by MDCT with a high negative predictive value (between 98% and 100% in most studies). MDCT for the diagnosis of hemodynamically relevant coronary artery stenoses should be limited to patients who do not have a high pretest probability. In patients with a high pretest probability of coronary stenoses, a clinical benefit of MDCT coronary angiography is unlikely, given the increased likelihood that interventional treatment (invasive angiography or bypass surgery) will be necessary. In the case of equivocal stress-test results, it is conceivable but unproven that MDCT coronary CTA may facilitate a decision for or against invasive coronary angiography. Screening of asymptomatic individuals concerning the presence of coronary artery stenoses is not justified at present.

Coronary CTA for Coronary Artery Bypass Graft Assessment
Occlusion and patency of arterial and venous bypass grafts can be assessed with high accuracy (sensitivity of 100% for detection of bypass occlusion in 3 studies performed with 16-slice MDCT). However, the detection of coronary stenoses at the anastomotic site and in the native coronary arteries after bypass surgery has been difficult with both 16-slice145–153 and 64-slice systems.154 Specifically, overestimation of coronary obstruction has been reported in the presence of coronary calcification154 (Table 7).


View this table:
[in this window]
[in a new window]

 
Table 7. Evaluation of Coronary Artery Bypass Graft Occlusion and Patency by 16-Slice and 64-Slice Coronary CTA


*    Limitations of Coronary CTA and MRA
up arrowTop
up arrowIntroduction
up arrowMRA of the Coronary...
up arrowClinical Applications and...
*Limitations of Coronary CTA...
down arrowFuture Directions in Noninvasive...
down arrowSummary and Recommendations
down arrowReferences
 
Coronary MRA and CTA are purely diagnostic tests that do not provide an option for immediate intervention and do not presently serve as the only basis for performing coronary artery bypass surgery. No outcomes-based analysis has been performed to establish the usefulness of either modality in a given clinical situation. The published comparisons between coronary CTA and MRA on one hand and catheter-based angiography on the other have generally comprised relatively small groups of patients who were preselected to undergo angiography as well as CTA or MRA.

A technical limitation of both CTA and MRA is lower spatial resolution than is possible with invasive angiography. It has not been consistently shown that either method accurately grades the degree of luminal narrowing within coronary artery lesions. Because the temporal resolution is low, motion artifacts can occur that cause false-negative and false-positive findings. Other image artifacts can be introduced by the patient’s inability to follow breathing commands, involuntary motion of the diaphragm, and arrhythmias that occur during the CTA or MRA scan. Continuous visualization of the coronary arteries is not possible at present in patients with atrial fibrillation or frequent ectopy.

Potential risks associated with coronary CTA and MRA include the use of sublingual nitroglycerin as well as pharmacological control of heart rate for CTA. The image quality of coronary CTA has been shown to benefit by the administration of β-blocker therapy to slow the heart rate. The potential for patient self-referral for coronary CTA or MRA without knowledge of its benefits versus risks expands questions of risk assessment into the public health and policy arena.155

Limitations Specific to Coronary MRA
Relative to invasive angiography as well as coronary CTA, the spatial resolution of MRA is significantly lower. This lower spatial resolution, along with the necessity to average data from several cardiac cycles to form an image, is probably one of the primary reasons for the generally lower reported sensitivity and specificity of coronary MRA compared with CTA (Tables 2 through 6UpUpUpUpUp). However, one recent direct comparison of MRA and 16-slice MDCT coronary CTA showed similar sensitivity (75% versus 82%, respectively) and specificity (77% versus 79%, respectively)47 despite these acknowledged differences in spatial resolution between the two methods.

The techniques for coronary MRA vary based on the MR vendor and software availability. Coronary MRA may not be widely available, particularly at community imaging centers. Patients who have implanted electronic devices such as internal defibrillators are generally excluded from receiving MR imaging. Metal in the chest from sternal wires or from coronary stents may preclude visualization of coronary arteries near the metal. Claustrophobia occurs in 1% to 5% of patients who undergo MR imaging. This can be controlled by the administration of anxiolytics, but substantially altered breathing patterns and reduced ability to cooperate may negatively affect the quality of the examination. Nondiagnostic MRA examinations may occur in patients with highly irregular breathing patterns. Coronary MRA examination time in experienced labs should be {approx}30 minutes using a 2D breath-hold strategy. Using 3D whole-heart imaging, similar scanning times are reported.

Limitations Specific to Coronary CTA
Calcifications within the coronary arteries can cause false-negative and, more frequently, false-positive findings118 concerning the presence of coronary artery stenosis. Coronary artery segments with substantial calcification may not be evaluable with respect to the presence of a hemodynamically relevant stenosis. The coronary lumen is generally not well observed in the region of a coronary stent.

Coronary CTA requires intravenous injection of iodinated contrast media. Because patients may subsequently require invasive angiography, those with compromised renal function are generally excluded from coronary CTA. In addition to nephrotoxicity, intravenous administration of iodinated contrast media may also be associated with anaphylactoid reaction.156–161

The predominant risk of coronary CTA is radiation exposure (as discussed in Radiation Dose). Recent improvements in spatial and temporal resolution of MDCT have made coronary CTA feasible in infants and children, particularly for delineation of anomalous coronary artery origin and course. However, the projected lifetime cancer mortality that is attributable to radiation exposure from CT is significantly higher in children than in adults.162 Bismuth-coated latex shielding placed over breast tissue has been suggested to decrease breast radiation exposure by 40% without significant image degradation during CT of female children.163 High heart rates and the potential need for sedation further complicate the expansion of MDCT to the pediatric population.

Reporting of Coronary CTA and MRA Results
The coronary CTA or MRA report (Table 8) should provide as much information as possible using terminology similar to that used in the reporting of catheter-based angiography. Compared with MRA, coronary CTA is more frequently performed for clinical evaluation of atherosclerotic coronary artery disease. Coronary CTA can assess the presence of noncalcified and calcified coronary artery plaque, whereas coronary MRA cannot easily differentiate between the two. Although the additional performance of high-resolution imaging of the coronary artery wall may assist in plaque-component characterization,164 this technique is still in its infancy.


View this table:
[in this window]
[in a new window]

 
Table 8. Reporting of Coronary CTA and MRA Results

A comment should be made in the report regarding the technical quality of the examination, especially if it is poor or adversely affected by respiratory motion, cardiac motion, or poor contrast opacification. Unlike x-ray angiography, both CTA and MRA examinations will image the valves, great arteries, myocardium, pericardium, and adjacent lung tissue. A comment should be made in the report if an abnormality in these surrounding structures is present.

In reporting results of both coronary CTA and MRA, the physician should comment on the origin and course of the epicardial vessels. Particular mention should be made if the origin or course of an artery is anomalous. In addition, comment should be made as to whether the coronary artery system is right or left dominant. This may be determined by identifying whether the posterior descending artery and left posterior ventricular branch receive blood supply from the right (RCA) or left (usually left circumflex [LCX]) coronary artery system or both.

The report should state the presence, location, and size of any coronary artery aneurysmal or pseudoaneurysmal dilatations. The location and patency of coronary artery bypass grafts can be assessed with either method,150,165 and this information should be reported.

For coronary CTA, vessels of ≥1.5 to 2 mm in diameter can be assessed for atherosclerotic narrowing.166 Reporting should include all coronary arteries of this size, including epicardial vessels (left main, left anterior descending, left circumflex, RCA) and their branches (diagonals, obtuse marginals, left posterior ventricular branch, posterior descending artery, etc).

Images of the coronary arteries should be assessed on a workstation that allows for interactive manipulation and postprocessing of the acquired data set. Images should first be assessed on the transversely acquired source images, and the presence and location of coronary artery atherosclerosis should be noted. Most studies have used combinations of at least 2 types of image displays.167,168 Coronary arteries should be assessed by multiplanar reformations or curved multiplanar reformations perpendicular to one another at the vessel center. Thin maximum-intensity projection images may be useful for assessment but should not be the only data assessed for reporting purposes given the potential for missing coronary lesions due to overlapping high-density structures that may obscure lumen narrowing.

The location of the atherosclerotic lesions, namely, proximal, mid-, and distal for the RCA, and by anatomic landmarks for the left anterior descending and left circumflex arteries (ie, just prior to first diagonal), should be described in addition to whether the disease is diffuse or focal. For x-ray angiography, some investigators have described using a 15-segment model,169 and this reporting design may be used for coronary CTA.

With coronary CTA, images may also be reconstructed to obtain accurate functional cardiac information,170 such as left ventricular end-diastolic volume, end-systolic volume, and ejection fraction. This information may be helpful to the clinician and may be included if the analysis software for this purpose is available.


*    Future Directions in Noninvasive Coronary Artery Imaging With CT and Magnetic Resonance Imaging
up arrowTop
up arrowIntroduction
up arrowMRA of the Coronary...
up arrowClinical Applications and...
up arrowLimitations of Coronary CTA...
*Future Directions in Noninvasive...
down arrowSummary and Recommendations
down arrowReferences
 
Imaging of Atherosclerotic Plaque
Catheter-based angiographic studies have shown that myocardial infarction may result from rupture of a vulnerable plaque in the absence of a significant luminal stenosis. Other markers of vulnerability include presence of inflammatory cells, a thin fibrous cap, and a large lipid core.159–163 These rupture-prone plaques, which are 7 times more likely to ulcerate than the more severe, extensive plaques, are not visible on 2D x-ray angiography.171,172 Thus, techniques for noninvasive imaging of atherosclerotic plaque with MR or CT have been of great interest.

The likelihood of plaque rupture is based on plaque composition rather than plaque volume.171,173 It has been observed that unstable plaques are generally higher in lipid content than stable plaques. Most ruptures occur in plaques containing a soft, lipid-rich core covered by a thin, inflamed fibrous cap.174 A thin fibrous cap is on the order of 70 µm, which is 10 times beyond the present in-plane resolution of MDCT (750 µm) and magnetic resonance imaging (MRI; 500 to 780 µm).175

Noncalcific Plaque Detection With Coronary CTA
Improved spatial and temporal image acquisition with submillimeter slice collimation has facilitated atherosclerotic plaque detection via MDCT. Preliminary studies suggest that CT has the potential to distinguish between fat tissue, fibrous tissue, and calcium. The lowest CT density values correlate well with lipid-laden plaque on intravascular ultrasound (IVUS), whereas intermediate densities correlate with fibrous lesions. However, overlap between densities makes distinction between fibrous and soft plaques more problematic.176 At present, assessment of noncalcified plaque remains limited to studies of very high image quality and may not pertain to average clinical applications.177–179

CT technology has been compared with intravascular ultrasound in the classification of plaque composition with cardiac CT.177,180–184 In the largest MDCT study that evaluated 875 coronary segments, sensitivity values for hypoechoic, hyperechoic, and calcific plaques were 78%, 78%, and 95%, respectively, whereas specificity was 92%.181 However, this study demonstrated that optimal diagnostic image quality was not obtained for 15% of coronary vessels. The investigators also conceded that noncalcific plaque visualization is limited by plaque and vessel size. The smaller plaques located in smaller coronary sections were not accurately characterized. Advances in spatial resolution in future generations of CT may help overcome these limitations.

Quantification of coronary atherosclerotic plaque burden using CT technology is presently limited. In the study by Achenbach et al,177 MDCT substantially underestimated plaque volume per segment as compared with IVUS (24±35 versus 43±60 mm3, P<0.001). In other comparisons between MDCT and IVUS, plaque areas showed moderate correlation (r=0.55) between the two methods, with a significant tendency toward overestimation by MDCT (8.3±4.8 versus 7.3±3.1 mm3, P<0.001).185 Plaque volumes in the proximal coronary arteries were found to correlate significantly between 64-slice MDCT and IVUS, with a correlation coefficient of r=0.83.179 However, interobserver variability for plaque volume measurements by MDCT have been as high as 37%.179 The Scientific Statement on Cardiac CT published by the American Heart Association discusses the applications of soft-plaque detection and the relationship to calcified plaque.186

Noncalcific Plaque Detection With MR
The coronary artery wall may be evaluated with MR using "black-blood" pulse sequences that do not require iodinated contrast media or ionizing radiation.178,187 Black-blood MR has been used extensively for imaging plaque in the carotid wall.188–197 At present, the maximum resolution of the method is 500 to 780 µm.

The wall thickness in MR corresponds to intima, media, and adventitial layers, with increased wall thickening in atherosclerosis occurring primarily in the media.196,198,199 In patient studies, coronary wall MR identified increased coronary artery wall thickness with preservation of lumen size in patients with nonsignificant coronary artery disease, which is consistent with a Glagov type of outward arterial remodeling.178 MR of coronary arteries in patients with >40% stenosis as assessed by x-ray angiography revealed localized wall thickness; the difference in maximum wall thickness between the normal subjects and patients was statistically significant (P=0.0001).189 Individuals with mild yet angiographically detectable coronary artery disease had a wall thickness as measured by MR of 1.7±0.3 mm; wall thickness in healthy subjects was 1.0±0.2 mm.178

Intravascular MR Contrast Agents
Current FDA-approved contrast agents for MR in the United States are extracellular agents that leak rapidly (within seconds) out of the vessel lumen into the extracellular spaces. This leakage reduces enhancement of the vessel lumen. Newer intravascular agents (the so-called blood-pool agents) that are based either on gadolinium (eg, B22956 and MS-325) or iron oxide (eg, AMI 227) have been developed.18,19,200–202 The use of intravascular agents has the advantage of allowing image acquisition over longer time periods. Because the signal of blood remains relatively constant for a prolonged time after a single injection, navigator approaches or multiple breath-holds can be used after a single injection.18 Initial results for these contrast agents in improving vessel signal203,204 and sharpness203,205 have been reported.


*    Summary and Recommendations
up arrowTop
up arrowIntroduction
up arrowMRA of the Coronary...
up arrowClinical Applications and...
up arrowLimitations of Coronary CTA...
up arrowFuture Directions in Noninvasive...
*Summary and Recommendations
down arrowReferences
 
Noninvasive coronary CTA and MRA represent substantial advances that may ultimately be valuable for diagnosis of significant coronary artery disease. The chief advantages of coronary CTA compared with MRA are wider availability, higher spatial resolution, and more consistent, shorter examinations with better patient adherance. Advantages associated with coronary MRA are a lack of ionizing radiation and a lack of administration of iodinated contrast material. Both tests are presently suboptimal for patients with atrial fibrillation and other arrhythmias, and image quality may be further reduced by high body mass.

Specific recommendations for use of these technologies are expected to change along with advances in scanner hardware and software. At present, the following general statements represent the consensus opinions of the writing group:

Classification of recommendations and levels of evidence are expressed in the American College of Cardiology/American Heart Association (ACC/AHA) format as follows:


*    Acknowledgments
 
Disclosures

DownDownDown


View this table:
[in this window]
[in a new window]

 
Writing Group Disclosures


View this table:
[in this window]
[in a new window]

 
Continued


View this table:
[in this window]
[in a new window]

 
Reviewer Disclosures


*    Footnotes
 
The American Heart Association makes every effort to avoid any actual or potential conflicts of interest that may arise as a result of an outside relationship or a personal, professional, or business interest of a member of the writing panel. Specifically, all members of the writing group are required to complete and submit a Disclosure Questionnaire showing all such relationships that might be perceived as real or potential conflicts of interest.

This statement was approved by the American Heart Association Science Advisory and Coordinating Committee on April 2, 2008. A single reprint is available by calling 800-242-8721 (US only) or by writing the American Heart Association, Public Information, 7272 Greenville Ave, Dallas, TX 75231-4596. Ask for reprint No. 71-0452. A copy of the statement is also available at http://www.americanheart.org/presenter.jhtml?identifier=3003999 by selecting either the "topic list" link or the "chronological list" link. To purchase additional reprints, call 843-216-2533 or e-mail kelle.ramsay@wolterskluwer.com.

Expert peer review of AHA Scientific Statements is conducted at the AHA National Center. For more on AHA statements and guidelines development, visit http://www.americanheart.org/presenter.jhtml?identifier=3023366.

Permissions: Multiple copies, modification, alteration, enhancement, and/or distribution of this document are not permitted without the express permission of the American Heart Association. Instructions for obtaining permission are located at http://www.americanheart.org/presenter.jhtml? identifier=4431. A link to the "Permission Request Form" appears on the right side of the page.


*    References
up arrowTop
up arrowIntroduction
up arrowMRA of the Coronary...
up arrowClinical Applications and...
up arrowLimitations of Coronary CTA...
up arrowFuture Directions in Noninvasive...
up arrowSummary and Recommendations
*References
 
1. Ammann P, Brunner-La Rocca HP, Angehrn W, Roelli H, Sagmeister M, Rickli H. Procedural complications following diagnostic coronary angiography are related to the operator’s experience and the catheter size. Catheter Cardiovasc Interv. 2003; 59: 13–18.[CrossRef][Medline] [Order article via Infotrieve]

2. Batyraliev T, Ayalp MR, Sercelik A, Karben Z, Dinler G, Besnili F, Ozgul S, Perchucov I. Complications of cardiac catheterization: a single-center study. Angiology. 2005; 56: 75–80.[Abstract/Free Full Text]

3. Chandrasekar B, Doucet S, Bilodeau L, Crepeau J, deGuise P, Gregoire J, Gallo R, Cote G, Bonan R, Joyal M, Gosselin G, Tanguay JF, Dyrda I, Bois M, Pasternac A. Complications of cardiac catheterization in the current era: a single-center experience. Catheter Cardiovasc Interv. 2001; 52: 289–295.[CrossRef][Medline] [Order article via Infotrieve]

4. Foo TK, Ho VB, Saranathan M, Cheng LQ, Sakuma H, Kraitchman DL, Wu KC, Bluemke DA. Feasibility of integrating high-spatial-resolution 3D breath-hold coronary MR angiography with myocardial perfusion and viability examinations. Radiology. 2005; 235: 1025–1030.[Abstract/Free Full Text]

5. Danias PG, Stuber M, Botnar RM, Kissinger KV, Chuang ML, Manning WJ. Navigator assessment of breath-hold duration: impact of supplemental oxygen and hyperventilation. AJR Am J Roentgenol. 1998; 171: 395–397.[Free Full Text]

6. Liu YL, Riederer SJ, Rossman PJ, Grimm RC, Debbins JP, Ehman RL. A monitoring, feedback, and triggering system for reproducible breath-hold MR imaging. Magn Reson Med. 1993; 30: 507–511.[Medline] [Order article via Infotrieve]

7. Wang Y, Grimm RC, Rossman PJ, Debbins JP, Riederer SJ, Ehman RL. 3D coronary MR angiography in multiple breath-holds using a respiratory feedback monitor. Magn Reson Med. 1995; 34: 11–16.[Medline] [Order article via Infotrieve]

8. Ehman RL, Felmlee JP. Adaptive technique for high-definition MR imaging of moving structures. Radiology. 1989; 173: 255–263.[Abstract/Free Full Text]

9. McConnell MV, Khasgiwala VC, Savord BJ, Chen MH, Chuang ML, Edelman RR, Manning WJ. Prospective adaptive navigator correction for breath-hold MR coronary angiography. Magn Reson Med. 1997; 37: 148–152.[Medline] [Order article via Infotrieve]

10. Danias PG, McConnell MV, Khasgiwala VC, Chuang ML, Edelman RR, Manning WJ. Prospective navigator correction of image position for coronary MR angiography. Radiology. 1997; 203: 733–736.[Abstract/Free Full Text]

11. Stuber M, Botnar RM, Danias PG, Kissinger KV, Manning WJ. Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology. 1999; 212: 579–587.[Abstract/Free Full Text]

12. Stuber M, Botnar RM, Danias PG, Sodickson DK, Kissinger KV, Van Cauteren M, De Becker J, Manning WJ. Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. J Am Coll Cardiol. 1999; 34: 524–531.[Abstract/Free Full Text]

13. Spuentrup E, Stuber M, Botnar RM, Manning WJ. The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography. J Magn Reson Imaging. 2001; 14: 311–318.[CrossRef][Medline] [Order article via Infotrieve]

14. Edelman RR, Manning WJ, Burstein D, Paulin S. Coronary arteries: breath-hold MR angiography. Radiology. 1991; 181: 641–643.[Abstract/Free Full Text]

15. Li D, Paschal CB, Haacke EM, Adler LP. Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast. Radiology. 1993; 187: 401–406.[Abstract/Free Full Text]

16. Brittain JH, Hu BS, Wright GA, Meyer CH, Macovski A, Nishimura DG. Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med. 1995; 33: 689–696.[Medline] [Order article via Infotrieve]

17. Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ. Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation. 1999; 99: 3139–3148.[Abstract/Free Full Text]

18. Stuber M, Botnar RM, Danias PG, McConnell MV, Kissinger KV, Yucel EK, Manning WJ. Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography. J Magn Reson Imaging. 1999; 10: 790–799.[CrossRef][Medline] [Order article via Infotrieve]

19. Hofman MB, Henson RE, Kovács SJ, Fischer SE, Lauffer RB, Adzamli K, De Becker J, Wickline SA, Lorenz CH. Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse. Magn Reson Med. 1999; 41: 360–367.[CrossRef][Medline] [Order article via Infotrieve]

20. Goldfarb JW, Edelman RR. Coronary arteries: breath-hold, gadolinium-enhanced, three-dimensional MR angiography. Radiology. 1998; 206: 830–834.[Abstract/Free Full Text]

21. Deshpande VS, Shea SM, Laub G, Simonetti OP, Finn JP, Li D. 3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries. Magn Reson Med. 2001; 46: 494–502.[CrossRef][Medline] [Order article via Infotrieve]

22. Spuentrup E, Buecker A, Stuber M, Botnar R, Nguyen TH, Börnert P, Kölker C, Günther RW. Navigator-gated coronary magnetic resonance angiography using steady-state-free-precession: comparison to standard T2-prepared gradient-echo and spiral imaging. Invest Radiol. 2003; 38: 263–268.[CrossRef][Medline] [Order article via Infotrieve]

23. Moran PR. A flow velocity zeugmatographic interlace for NMR imaging in humans. Magn Reson Imaging. 1982; 1: 197–203.[CrossRef][Medline] [Order article via Infotrieve]

24. Firmin DN, Nayler GL, Kilner PJ, Longmore DB. The application of phase shifts in NMR for flow measurement. Magn Reson Med. 1990; 14: 230–241.[Medline] [Order article via Infotrieve]

25. Sakuma H, Blake LM, Amidon TM, O'Sullivan M, Szolar DH, Furber AP, Bernstein MA, Foo TK, Higgins CB. Coronary flow reserve: noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging. Radiology. 1996; 198: 745–750.[Abstract/Free Full Text]

26. Weiger M, Pruessmann KP, Boesiger P. Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme. Magn Reson Med. 2000; 43: 177–184.[CrossRef][Medline] [Order article via Infotrieve]

27. Stuber M, Botnar RM, Fischer SE, Lamerichs R, Smink J, Harvey P, Manning WJ. Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med. 2002; 48: 425–429.[CrossRef][Medline] [Order article via Infotrieve]

28. Kim WY, Danias PG, Stuber M, Flamm SD, Plein S, Nagel E, Langerak SE, Weber OM, Pedersen EM, Schmidt M, Botnar RM, Manning WJ. Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med. 2001; 345: 1863–1869.[Abstract/Free Full Text]

29. Sakuma H, Ichikawa Y, Suzawa N, Hirano T, Makino K, Koyama N, Van Cauteren M, Takeda K. Assessment of coronary arteries with total study time of less than 30 minutes by using whole-heart coronary MR angiography. Radiology. 2005; 237: 316–321.[Abstract/Free Full Text]

30. McConnell MV, Ganz P, Selwyn AP, Li W, Edelman RR, Manning WJ. Identification of anomalous coronary arteries and their anatomic course by magnetic resonance coronary angiography. Circulation. 1995; 92: 3158–3162.[Abstract/Free Full Text]

31. Taylor AM, Thorne SA, Rubens MB, Jhooti P, Keegan J, Gatehouse PD, Wiesmann F, Grothues F, Somerville J, Pennell DJ. Coronary artery imaging in grown up congenital heart disease: complementary role of magnetic resonance and x-ray coronary angiography. Circulation. 2000; 101: 1670–1678.[Abstract/Free Full Text]

32. Post JC, van Rossum AC, Bronzwaer JG, de Cock CC, Hofman MB, Valk J, Visser CA. Magnetic resonance angiography of anomalous coronary arteries. A new gold standard for delineating the proximal course? Circulation. 1995; 92: 3163–3171.[Abstract/Free Full Text]

33. Vliegen HW, Doornbos J, de Roos A, Jukema JW, Bekedam MA, van der Wall EE. Value of fast gradient echo magnetic resonance angiography as an adjunct to coronary arteriography in detecting and confirming the course of clinically significant coronary artery anomalies. Am J Cardiol. 1997; 79: 773–776.[CrossRef][Medline] [Order article via Infotrieve]

34. Machado C, Bhasin S, Soulen RL. Confirmation of anomalous origin of the right coronary artery from the left sinus of Valsalva with magnetic resonance imaging. Chest. 1993; 104: 1284–1286.[CrossRef][Medline] [Order article via Infotrieve]

35. Doorey AJ, Wills JS, Blasetto J, Goldenberg EM. Usefulness of magnetic resonance imaging for diagnosing an anomalous coronary artery coursing between aorta and pulmonary trunk. Am J Cardiol. 1994; 74: 198–199.[CrossRef][Medline] [Order article via Infotrieve]

36. Razmi RM, Chun W, Rathi VK, Pohost GM. Coronary magnetic resonance angiography (CMRA): the gold standard for determining the proximal course of anomalous coronary arteries. J Am Coll Cardiol. 2001; 37: 380. Abstract.

37. Bunce NH, Lorenz CH, Keegan J, Lesser J, Reyes EM, Firmin DN, Pennell DJ. Coronary artery anomalies: assessment with free-breathing three-dimensional coronary MR angiography. Radiology. 2003; 227: 201–208.[Abstract/Free Full Text]

38. Greil GF, Stuber M, Botnar RM, Kissinger KV, Geva T, Newburger JW, Manning WJ, Powell AJ. Coronary magnetic resonance angiography in adolescents and young adults with kawasaki disease. Circulation. 2002; 105: 908–911.[Abstract/Free Full Text]

39. Mavrogeni S, Papadopoulos G, Douskou M, Kaklis S, Seimenis I, Baras P, Nikolaidou P, Bakoula C, Karanasios E, Manginas A, Cokkinos DV. Magnetic resonance angiography is equivalent to X-ray coronary angiography for the evaluation of coronary arteries in Kawasaki disease. J Am Coll Cardiol. 2004; 43: 649–652.[Abstract/Free Full Text]

40. Newburger JW, Takahashi M, Gerber MA, Gewitz MH, Tani LY, Burns JC, Shulman ST, Bolger AF, Ferrieri P, Baltimore RS, Wilson WR, Baddour LM, Levison ME, Pallasch TJ, Falace DA, Taubert KA. Diagnosis, treatment, and long-term management of Kawasaki disease: a statement for health professionals from the Committee on Rheumatic Fever, Endocarditis, and Kawasaki Disease, Council on Cardiovascular Disease in the Young, American Heart Association. Pediatrics. 2004; 114: 1708–1733.[Abstract/Free Full Text]

41. Mavrogeni SI, Manginas A, Papadakis E, Foussas S, Douskou M, Baras P, Seimenis I, Cokkinos DV. Correlation between magnetic resonance angiography (MRA) and quantitative coronary angiography (QCA) in ectatic coronary vessels. J Cardiovasc Magn Reson. 2004; 6: 17–23.[CrossRef][Medline] [Order article via Infotrieve]

42. Ichikawa YSH, Makino K, Okano S, Chino S, Hirano T, Takeda K. Diagnostic accuracy of whole heart coronary magnetic resonance angiography for the detection of significant coronary stenoses in patients with suspected coronary artery disease. Paper presented at: 8th Annual Scientific Sessions of the Society for Cardiovascular Magnetic Resonance; January 21 to 23, 2005; San Francisco, Calif.

43. Jahnke C, Paetsch I, Nehrke K, Schnackenburg B, Gebker R, Fleck E, Nagel E. Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance. Eur Heart J. 2005; 26: 2313–2319.[Abstract/Free Full Text]

44. Cheng L, Guaricci A, Mulukutla S, Prince MR, Wang Y. Manifestation of coronary stenoses on breath-hold steady state free precession sequences: retrospectively compared to conventional x-ray coronary angiography. J Cardiovasc Magn Reson. 2005; 117.

45. Dewey M, Teige F, Schnapauff D, Laule M, Borges AC, Rutsch W, Hamm B, Taupitz M. Combination of free-breathing and breathhold steady-state free precession magnetic resonance angiography for detection of coronary artery stenoses. J Magn Reson Imaging. 2006; 23: 674–681.[CrossRef][Medline] [Order article via Infotrieve]

46. Sakuma H, Ichikawa Y, Chino S, Hirano T, Makino K, Takeda K. Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography. J Am Coll Cardiol. 2006; 48: 1946–1950.[Abstract/Free Full Text]

47. Kefer J, Coche E, Legros G, Pasquet A, Grandin C, Van Beers BE, Vanoverschelde JL, Gerber BL. Head-to-head comparison of three-dimensional navigator-gated magnetic resonance imaging and 16-slice computed tomography to detect coronary artery stenosis in patients. J Am Coll Cardiol. 2005; 46: 92–100.[Abstract/Free Full Text]

48. Dewey M, Teige F, Schnapauff D, Laule M, Borges AC, Wernecke KD, Schink T, Baumann G, Rutsch W, Rogalla P, Taupitz M, Hamm B. Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging. Ann Intern Med. 2006; 145: 407–415.[Abstract/Free Full Text]

49. Hundley WG, Lange RA, Clarke GD, Meshack BM, Payne J, Landau C, McColl R, Sayad DE, Willett DL, Willard JE, Hillis LD, Peshock RM. Assessment of coronary arterial flow and flow reserve in humans with magnetic resonance imaging. Circulation. 1996; 93: 1502–1508.[Abstract/Free Full Text]

50. Nagel E, Lehmkuhl HB, Bocksch W, Klein C, Vogel U, Frantz E, Ellmer A, Dreysse S, Fleck E. Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography. Circulation. 1999; 99: 763–770.[Abstract/Free Full Text]

51. Hundley WG, Hamilton CA, Clarke GD, Hillis LD, Herrington DM, Lange RA, Applegate RJ, Thomas MS, Payne J, Link KM, Peshock RM. Visualization and functional assessment of proximal and middle left anterior descending coronary stenoses in humans with magnetic resonance imaging. Circulation. 1999; 99: 3248–3254.[Abstract/Free Full Text]

52. Hundley WG, Hillis LD, Hamilton CA, Applegate RJ, Herrington DM, Clarke GD, Braden GA, Thomas MS, Lange RA, Peshock RM, Link KM. Assessment of coronary arterial restenosis with phase-contrast magnetic resonance imaging measurements of coronary flow reserve. Circulation. 2000; 101: 2375–2381.[Abstract/Free Full Text]

53. Langerak SE, Vliegen HW, Jukema JW, Kunz P, Zwinderman AH, Lamb HJ, van der Wall EE, de Roos A. Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipient coronary arteries. Circulation. 2003; 107: 1502–1508.[Abstract/Free Full Text]

54. Sakuma H, Higgins CB. Magnetic resonance measurement of coronary blood flow. Acta Paediatr Suppl. 2004; 93: 80–85.[CrossRef][Medline] [Order article via Infotrieve]

55. Nagel E, Thouet T, Klein C, Schalla S, Bornstedt A, Schnackenburg B, Hug J, Wellnhofer E, Fleck E. Noninvasive determination of coronary blood flow velocity with cardiovascular magnetic resonance in patients after stent deployment. Circulation. 2003; 107: 1738–1743.[Abstract/Free Full Text]

56. van Geuns RJ, Wielopolski PA, de Bruin HG, Rensing BJ, Hulshoff M, van Ooijen PM, de Feyter PJ, Oudkerk M. MR coronary angiography with breath-hold targeted volumes: preliminary clinical results. Radiology. 2000; 217: 270–277.[Abstract/Free Full Text]

57. Goldman S, Copeland J, Moritz T, Henderson W, Zadina K, Ovitt T, Doherty J, Read R, Chesler E, Sako Y. Saphenous vein graft patency 1 year after coronary artery bypass surgery and effects of antiplatelet therapy. Results of a Veterans Administration Cooperative Study. Circulation. 1989; 80: 1190–1197.[Abstract/Free Full Text]

58. Fitzgibbon GM, Kafka HP, Leach AJ, Keon WJ, Hooper GD, Burton JR. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years. J Am Coll Cardiol. 1996; 28: 616–626.[Abstract]

59. White RD, Caputo GR, Mark AS, Modin GW, Higgins CB. Coronary artery bypass graft patency: noninvasive evaluation with MR imaging. Radiology. 1987; 164: 681–686.[Abstract/Free Full Text]

60. White RD, Pflugfelder PW, Lipton MJ, Higgins CB. Coronary artery bypass grafts: evaluation of patency with cine MR imaging. AJR Am J Roentgenol. 1988; 150: 1271–1274.[Abstract/Free Full Text]

61. Galjee MA, van Rossum AC, Doesburg T, van Eenige MJ, Visser CA. Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study. Circulation. 1996; 93: 660–666.[Abstract/Free Full Text]

62. Aurigemma GP, Reichek N, Axel L, Schiebler M, Harris C, Kressel HY. Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging. Circulation. 1989; 80: 1595–1602.[Abstract/Free Full Text]

63. Engelmann MG, Knez A, von Smekal A, Wintersperger BJ, Huehns TY, Hofling B, Reiser MF, Steinbeck G. Non-invasive coronary bypass graft imaging after multivessel revascularisation. Int J Cardiol. 2000; 76: 65–74.[CrossRef][Medline] [Order article via Infotrieve]

64. Molinari G, Sardanelli F, Zandrino F, Balbi M, Masperone MA. Value of navigator echo magnetic resonance angiography in detecting occlusion/patency of arterial and venous, single and sequential coronary bypass grafts. Int J Card Imaging. 2000; 16: 149–160.[CrossRef][Medline] [Order article via Infotrieve]

65. Vrachliotis TG, Bis KG, Aliabadi D, Shetty AN, Safian R, Simonetti O. Contrast-enhanced breath-hold MR angiography for evaluating patency of coronary artery bypass grafts. AJR Am J Roentgenol. 1997; 168: 1073–1080.[Abstract/Free Full Text]

66. Wintersperger BJ, Engelmann MG, von Smekal A, Knez A, Penzkofer HV, Höfling B, Laub G, Reiser MF. Patency of coronary bypass grafts: assessment with breath-hold contrast-enhanced MR angiography: value of a non-electrocardiographically triggered technique. Radiology. 1998; 208: 345–351.[Abstract/Free Full Text]

67. Bunce NH, Lorenz CH, John AS, Lesser JR, Mohiaddin RH, Pennell DJ. Coronary artery bypass graft patency: assessment with true ast imaging with steady-state precession versus gadolinium-enhanced MR angiography. Radiology. 2003; 227: 440–446.[Abstract/Free Full Text]

68. Lu B, Mao SS, Zhuang N, Bakhsheshi H, Yamamoto H, Takasu J, Liu SC, Budoff MJ. Coronary artery motion during the cardiac cycle and optimal ECG triggering for coronary artery imaging. Invest Radiol. 2001; 36: 250–256.[CrossRef][Medline] [Order article via Infotrieve]

69. Ritchie CJ, Godwin JD, Crawford CR, Stanford W, Anno H, Kim Y. Minimum scan speeds for suppression of motion artifacts in CT. Radiology. 1992; 185: 37–42.[Abstract/Free Full Text]

70. Kachelriess M, Kalender WA. Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys. 1998; 25: 2417–2431.[CrossRef][Medline] [Order article via Infotrieve]

71. Ohnesorge B, Flohr T, Becker C, Kopp AF, Schoepf UJ, Baum U, Knez A, Klingenbeck-Regn K, Reiser MF. Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology. 2000; 217: 564–571.[Abstract/Free Full Text]

72. Flohr T, Ohnesorge B. Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr. 2001; 25: 907–923.[CrossRef][Medline] [Order article via Infotrieve]

73. Flohr TG, McCollough CH, Bruder H, Petersilka M, Gruber K, Süss C, Grasruck M, Stierstorfer K, Krauss B, Raupach R, Primak AN, Küttner A, Achenbach S, Becker C, Kopp A, Ohnesorge BM. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006; 16: 256–268.[CrossRef][Medline] [Order article via Infotrieve]

74. Nikolaou K, Becker CR, Muders M, Babaryka G, Scheidler J, Flohr T, Loehrs U, Reiser MF, Fayad ZA. Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries. Atherosclerosis. 2004; 174: 243–252.[Medline] [Order article via Infotrieve]

75. Giesler T, Baum U, Ropers D, Ulzheimer S, Wenkel E, Mennicke M, Bautz W, Kalender WA, Daniel WG, Achenbach S. Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. AJR Am J Roentgenol. 2002; 179: 911–916.[Abstract/Free Full Text]

76. Herzog C, Abolmaali N, Balzer JO, Baunach S, Ackermann H, Dogan S, Britten MB, Vogl TJ. Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol. 2002; 12: 2670–2678.[Medline] [Order article via Infotrieve]

77. Hoffmann MH, Shi H, Manzke R, Schmid FT, De Vries L, Grass M, Brambs HJ, Aschoff AJ. Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology. 2005; 234: 86–97.[Abstract/Free Full Text]

78. Schroeder S, Kopp AF, Kuettner A, Burgstahler C, Herdeg C, Heuschmid M, Baumbach A, Claussen CD, Karsch KR, Seipel L. Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients. Clin Imaging. 2002; 26: 106–111.[CrossRef][Medline] [Order article via Infotrieve]

79. Gerber TC, Kuzo RS, Lane GE, O'Brien PC, Karstaedt N, Morin RL, Safford RE, Blackshear JL, Pietan JH. Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography. J Comput Assist Tomogr. 2003; 27: 62–69.[CrossRef][Medline] [Order article via Infotrieve]

80. Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W. In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology. 2000; 216: 457–463.[Abstract/Free Full Text]

81. Wintersperger BJ, Nikolaou K, von Ziegler F, Johnson T, Rist C, Leber A, Flohr T, Knez A, Reiser MF, Becker CR. Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Invest Radiol. 2006; 41: 436–442.[CrossRef][Medline] [Order article via Infotrieve]

82. Achenbach S, Ropers D, Kuettner A, Flohr T, Ohnesorge B, Bruder H, Theessen H, Karakaya M, Daniel WG, Bautz W, Kalender WA, Anders K. Contrast-enhanced coronary artery visualization by dual-source computed tomography: initial experience. Eur J Radiol. 2006; 57: 331–335.[CrossRef][Medline] [Order article via Infotrieve]

83. Dewey M, Hoffmann H, Hamm B. Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Rofo. 2006; 178: 600–604.[Medline] [Order article via Infotrieve]

84. Morin RL, Gerber TC, McCollough CH. Radiation dose in computed tomography of the heart. Circulation. 2003; 107: 917–922.[Free Full Text]

85. Gerber TC, Stratmann BP, Kuzo RS, Kantor B, Morin RL. Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation. Invest Radiol. 2005; 40: 556–563.[CrossRef][Medline] [Order article via Infotrieve]

86. International Electrotechnical Commission. International Standard IEC 60601-2-44 Edition 2.1: Medical Electrical Equipment, Part 2-44: Particular Requirements for the Safety of X-ray Equipment for Computed Tomography. Geneva, Switzerland: International Electrotechnical Commission; 2002.

87. 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 1991; 21: 1–201.[Medline] [Order article via Infotrieve]

88. McCollough CH, Schueler BA. Calculation of effective dose. Med Phys. 2000; 27: 828–837.[CrossRef][Medline] [Order article via Infotrieve]

89. Morin RL. What are the national radiation doses? J Am Coll Radiol. 2006; 3: 956.[CrossRef][Medline] [Order article via Infotrieve]

90. Hunold P, Vogt FM, Schmermund A, Debatin JF, Kerkhoff G, Budde T, Erbel R, Ewen K, Barkhausen J. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology. 2003; 226: 145–152.[Abstract/Free Full Text]

91. National Council on Radiation Protection and Measurements. Report 94: Exposure of the Population in the United States and Canada From Natural Background Radiation. Bethesda, Md: National Council on Radiation Protection and Measurements; 1987.

92. Coles DR, Smail MA, Negus IS, Wilde P, Oberhoff M, Karsch KR, Baumbach A. Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography. J Am Coll Cardiol. 2006; 47: 1840–1845.[Abstract/Free Full Text]

93. Garcia MJ. Noninvasive coronary angiography: hype or new paradigm? JAMA. 2005; 293: 2531–2533.[Free Full Text]

94. Jakobs TF, Becker CR, Ohnesorge BM, Schoepf UO, Reiser MF. Tube current modulation for retrospective ECG-gated cardiac-CT. Radiology. 2001; 221: 414.

95. Trabold T, Büchgeister M, Kuttner A, Heuschmid M, Kopp AF, Schröder S, Claussen CD. Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Rofo. 2003; 175: 1051–1055.[Medline] [Order article via Infotrieve]

96. Sanz J, Rius T, Kuschnir P, Fuster V, Goldberg J, Ye XY, Wisdom P, Poon M. The importance of end-systole for optimal reconstruction protocol of coronary angiography with 16-slice multidetector computed tomography. Invest Radiol. 2005; 40: 155–163.[CrossRef][Medline] [Order article via Infotrieve]

97. Mollet NR, Cademartiri F, Nieman K, Saia F, Lemos PA, McFadden EP, Pattynama PM, Serruys PW, Krestin GP, de Feyter PJ. Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol. 2004; 43: 2265–2270.[Abstract/Free Full Text]

98. Gies M, Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies. Med Phys. 1999; 26: 2235–2247.[CrossRef][Medline] [Order article via Infotrieve]

99. Kalender WA, Wolf H, Suess C, Gies M, Greess H, Bautz WA. Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers. Eur Radiol. 1999; 9: 323–328.[CrossRef][Medline] [Order article via Infotrieve]

100. Leber AW, Knez A, von Ziegler F, Becker A, Nikolaou K, Paul S, Wintersperger B, Reiser M, Becker CR, Steinbeck G, Boekstegers P. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol. 2005; 46: 147–154.[Abstract/Free Full Text]

101. Mollet NR, Cademartiri F, van Mieghem CA, Runza G, McFadden EP, Baks T, Serruys PW, Krestin GP, de Feyter PJ. High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation. 2005; 112: 2318–2323.[Abstract/Free Full Text]

102. Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol. 2005; 46: 552–557.[Abstract/Free Full Text]

103. Hausleiter J, Meyer T, Hadamitzky M, Huber E, Zankl M, Martinoff S, Kastrati A, Schömig A. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation. 2006; 113: 1305–1310.[Abstract/Free Full Text]

104. Schmid M, Achenbach S, Ludwig J, Baum U, Anders K, Pohle K, Daniel WG, Ropers D. Visualization of coronary artery anomalies by contrast-enhanced multi-detector row spiral computed tomography. Int J Cardiol. 2006; 111: 430–435.[CrossRef][Medline] [Order article via Infotrieve]

105. Datta J, White CS, Gilkeson RC, Meyer CA, Kansal S, Jani ML, Arildsen RC, Read K. Anomalous coronary arteries in adults: depiction at multi-detector row CT angiography. Radiology. 2005; 235: 812–818.[Abstract/Free Full Text]

106. Schmitt R, Froehner S, Brunn J, Wagner M, Brunner H, Cherevatyy O, Gietzen F, Christopoulos G, Kerber S, Fellner F. Congenital anomalies of the coronary arteries: imaging with contrast-enhanced, multidetector computed tomography. Eur Radiol. 2005; 15: 1110–1121.[CrossRef][Medline] [Order article via Infotrieve]

107. Sato Y, Inoue F, Matsumoto N, Tani S, Takayama T, Yoda S, Kunimasa T, Ishii N, Uchiyama T, Saito S, Tanaka H, Furuhashi S, Takahashi M, Koyama Y. Detection of anomalous origins of the coronary artery by means of multislice computed tomography. Circ J. 2005; 69: 320–324.[CrossRef][Medline] [Order article via Infotrieve]

108. Shi H, Aschoff AJ, Brambs HJ, Hoffmann MH. Multislice CT imaging of anomalous coronary arteries. Eur Radiol. 2004; 14: 2172–2181.[CrossRef][Medline] [Order article via Infotrieve]

109. van Ooijen PM, Dorgelo J, Zijlstra F, Oudkerk M. Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT. Eur Radiol. 2004; 14: 2163–2171.[CrossRef][Medline] [Order article via Infotrieve]

110. Deibler AR, Kuzo RS, Vöhringer M, Page EE, Safford RE, Patron JN, Lane GE, Morin RL, Gerber TC. Imaging of congenital coronary anomalies with multislice computed tomography. Mayo Clin Proc. 2004; 79: 1017–1023.[Abstract/Free Full Text]

111. Lessick J, Kumar G, Beyar R, Lorber A, Engel A. Anomalous origin of a posterior descending artery from the right pulmonary artery: report of a rare case diagnosed by multidetector computed tomography angiography. J Comput Assist Tomogr. 2004; 28: 857–859.[CrossRef][Medline] [Order article via Infotrieve]

112. Ropers D, Moshage W, Daniel WG, Jessl J, Gottwik M, Achenbach S. Visualization of coronary artery anomalies and their anatomic course by contrast-enhanced electron beam tomography and three-dimensional reconstruction. Am J Cardiol. 2001; 87: 193–197.[CrossRef][Medline] [Order article via Infotrieve]

113. Ferencik M, Moselewski F, Ropers D, Hoffmann U, Baum U, Anders K, Pomerantsev EV, Abbara S, Brady TJ, Achenbach S. Quantitative parameters of image quality in multidetector spiral computed tomographic coronary imaging with submillimeter collimation. Am J Cardiol. 2003; 92: 1257–1262.[CrossRef][Medline] [Order article via Infotrieve]

114. Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation. 2002; 106: 2051–2054.[Abstract/Free Full Text]

115. Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation. 2003; 107: 664–666.[Abstract/Free Full Text]

116. Kuettner A, Trabold T, Schroeder S, Feyer A, Beck T, Brueckner A, Heuschmid M, Burgstahler C, Kopp AF, Claussen CD. Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol. 2004; 44: 1230–1237.[Abstract/Free Full Text]

117. Martuscelli E, Romagnoli A, D'Eliseo A, Razzini C, Tomassini M, Sperandio M, Simonetti G, Romeo F. Accuracy of thin-slice computed tomography in the detection of coronary stenoses. Eur Heart J. 2004; 25: 1043–1048.[Abstract/Free Full Text]

118. Hoffmann U, Moselewski F, Cury RC, Ferencik M, Jang IK, Diaz LJ, Abbara S, Brady TJ, Achenbach S. Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation. 2004; 110: 2638–2643.[Abstract/Free Full Text]

119. Fine JJ, Hopkins CB, Hall PA, Delphia RE, Attebery TW, Newton FC. Noninvasive coronary angiography: agreement of multi-slice spiral computed tomography and selective catheter angiography. Int J Cardiovasc Imaging. 2004; 20: 549–552.[CrossRef][Medline] [Order article via Infotrieve]

120. Kaiser C, Bremerich J, Haller S, Brunner-La Rocca HP, Bongartz G, Pfisterer M, Buser P. Limited diagnostic yield of non-invasive coronary angiography by 16-slice multi-detector spiral computed tomography in routine patients referred for evaluation of coronary artery disease. Eur Heart J. 2005; 26: 1987–1992.[Abstract/Free Full Text]

121. Aviram G, Finkelstein A, Herz I, Lessick J, Miller H, Graif M, Keren G. Clinical value of 16-slice multi-detector CT compared to invasive coronary angiography. Int J Cardiovasc Intervent. 2005; 7: 21–28.[Medline] [Order article via Infotrieve]

122. Kuettner A, Beck T, Drosch T, Kettering K, Heuschmid M, Burgstahler C, Claussen CD, Kopp AF, Schroeder S. Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. J Am Coll Cardiol. 2005; 45: 123–127.[Abstract/Free Full Text]

123. Mollet NR, Cademartiri F, Krestin GP, McFadden EP, Arampatzis CA, Serruys PW, de Feyter PJ. Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography. J Am Coll Cardiol. 2005; 45: 128–132.[Abstract/Free Full Text]

124. Schuijf JD, Bax JJ, Salm LP, Jukema JW, Lamb HJ, van der Wall EE, de Roos A. Noninvasive coronary imaging and assessment of left ventricular function using 16-slice computed tomography. Am J Cardiol. 2005; 95: 571–574.[CrossRef][Medline] [Order article via Infotrieve]

125. Hoffmann MH, Shi H, Schmitz BL, Schmid FT, Lieberknecht M, Schulze R, Ludwig B, Kroschel U, Jahnke N, Haerer W, Brambs HJ, Aschoff AJ. Noninvasive coronary angiography with multislice computed tomography. JAMA. 2005; 293: 2471–2478.[Abstract/Free Full Text]

126. Morgan-Hughes GJ, Roobottom CA, Owens PE, Marshall AJ. Highly accurate coronary angiography with submillimetre, 16 slice computed tomography. Heart. 2005; 91: 308–313.[Abstract/Free Full Text]

127. Achenbach S, Ropers D, Pohle FK, Raaz D, von Erffa J, Yilmaz A, Muschiol G, Daniel WG. Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation. Eur Heart J. 2005; 26: 1978–1986.[Abstract/Free Full Text]

128. Ehara M, Surmely JF, Kawai M, Katoh O, Matsubara T, Terashima M, Tsuchikane E, Kinoshita Y, Suzuki T, Ito T, Takeda Y, Nasu K, Tanaka N, Murata A, Suzuki Y, Sato K, Suzuki T. Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J. 2006; 70: 564–571.[CrossRef][Medline] [Order article via Infotrieve]

129. Fine JJ, Hopkins CB, Ruff N, Newton FC. Comparison of accuracy of 64-slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease. Am J Cardiol. 2006; 97: 173–174.[CrossRef][Medline] [Order article via Infotrieve]

130. Leschka S, Alkadhi H, Plass A, Desbiolles L, Grunenfelder J, Marincek B, Wildermuth S. Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J. 2005; 26: 1482–1487.[Abstract/Free Full Text]

131. Ropers D, Rixe J, Anders K, Küttner A, Baum U, Bautz W, Daniel WG, Achenbach S. Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. Am J Cardiol. 2006; 97: 343–348.[CrossRef][Medline] [Order article via Infotrieve]

132. Vanhoenacker PK, Heijenbrok-Kal MH, Van Heste R, Decramer I, Van Hoe LR, Wijns W, Hunink MG. Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis. Radiology. 2007; 244: 419–428.[Abstract/Free Full Text]

133. Abdulla J, Abildstrom SZ, Gotzsche O, Christensen E, Kober L, Torp-Pedersen C. 64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis. Eur Heart J. 2007; 28: 3042–3050.[Abstract/Free Full Text]

134. Gilard M, Cornily JC, Rioufol G, Finet G, Pennec PY, Mansourati J, Blanc JJ, Boschat J. Noninvasive assessment of left main coronary stent patency with 16-slice computed tomography. Am J Cardiol. 2005; 95: 110–112.[CrossRef][Medline] [Order article via Infotrieve]

135. Schuijf JD, Bax JJ, Jukema JW, Lamb HJ, Warda HM, Vliegen HW, de Roos A, van der Wall EE. Feasibility of assessment of coronary stent patency using 16-slice computed tomography. Am J Cardiol. 2004; 94: 427–430.[CrossRef][Medline] [Order article via Infotrieve]

136. Gilard M, Cornily JC, Pennec PY, Le Gal G, Nonent M, Mansourati J, Blanc JJ, Boschat J. Assessment of coronary artery stents by 16 slice computed tomography. Heart. 2006; 92: 58–61.[Abstract/Free Full Text]

137. Kitagawa T, Fujii T, Tomohiro Y, Maeda K, Kobayashi M, Kunita E, Sekiguchi Y. Noninvasive assessment of coronary stents in patients by 16-slice computed tomography. Int J Cardiol. 2006; 109: 188–194.[CrossRef][Medline] [Order article via Infotrieve]

138. Gaspar T, Halon DA, Lewis BS, Adawi S, Schliamser JE, Rubinshtein R, Flugelman MY, Peled N. Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography. J Am Coll Cardiol. 2005; 46: 1573–1579.[Abstract/Free Full Text]

139. Cademartiri F, Mollet N, Lemos PA, Pugliese F, Baks T, McFadden EP, Krestin GP, de Feyter PJ. Usefulness of multislice computed tomographic coronary angiography to assess in-stent restenosis. Am J Cardiol. 2005; 96: 799–802.[CrossRef][Medline] [Order article via Infotrieve]

140. Rixe J, Achenbach S, Ropers D, Baum U, Kuettner A, Ropers U, Bautz W, Daniel WG, Anders K. Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography. Eur Heart J. 2006; 27: 2567–2572.[Abstract/Free Full Text]

141. Hong C, Chrysant GS, Woodard PK, Bae KT. Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience. Radiology. 2004; 233: 286–291.[Abstract/Free Full Text]

142. Mahnken AH, Buecker A, Wildberger JE, Ruebben A, Stanzel S, Vogt F, Günther RW, Blindt R. Coronary artery stents in multislice computed tomography: in vitro artifact evaluation. Invest Radiol. 2004; 39: 27–33.[CrossRef][Medline] [Order article via Infotrieve]

143. Maintz D, Seifarth H, Flohr T, Krämer S, Wichter T, Heindel W, Fischbach R. Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique. Invest Radiol. 2003; 38: 790–795.[Medline] [Order article via Infotrieve]

144. Seifarth H, Raupach R, Schaller S, Fallenberg EM, Flohr T, Heindel W, Fischbach R, Maintz D. Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter. Eur Radiol. 2005; 15: 721–726.[CrossRef][Medline] [Order article via Infotrieve]

145. Martuscelli E, Romagnoli A, D'Eliseo A, Tomassini M, Razzini C, Sperandio M, Simonetti G, Romeo F, Mehta JL. Evaluation of venous and arterial conduit patency by 16-slice spiral computed tomography. Circulation. 2004; 110: 3234–3238.[Abstract/Free Full Text]

146. Nieman K, Pattynama PM, Rensing BJ, Van Geuns RJ, De Feyter PJ. Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries. Radiology. 2003; 229: 749–756.[Abstract/Free Full Text]

147. Schlosser T, Konorza T, Hunold P, Kühl H, Schmermund A, Barkhausen J. Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography. J Am Coll Cardiol. 2004; 44: 1224–1229.[Abstract/Free Full Text]

148. Anders K, Baum U, Schmid M, Ropers D, Schmid A, Pohle K, Daniel WG, Bautz W, Achenbach S. Coronary artery bypass graft (CABG) patency: assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography. Eur J Radiol. 2006; 57: 336–344.[CrossRef][Medline] [Order article via Infotrieve]

149. Burgstahler C, Beck T, Kuettner A, Drosch T, Kopp AF, Heuschmid M, Claussen CD, Schroeder S. Non-invasive evaluation of coronary artery bypass grafts using 16-row multi-slice computed tomography with 188 ms temporal resolution. Int J Cardiol. 2006; 106: 244–249.[CrossRef][Medline] [Order article via Infotrieve]

150. Chiurlia E, Menozzi M, Ratti C, Romagnoli R, Modena MG. Follow-up of coronary artery bypass graft patency by multislice computed tomography. Am J Cardiol. 2005; 95: 1094–1097.[CrossRef][Medline] [Order article via Infotrieve]

151. Moore RK, Sampson C, MacDonald S, Moynahan C, Groves D, Chester MR. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: comparison with catheter angiography. Clin Radiol. 2005; 60: 990–998.[CrossRef][Medline] [Order article via Infotrieve]

152. Pache G, Saueressig U, Frydrychowicz A, Foell D, Ghanem N, Kotter E, Geibel-Zehender A, Bode C, Langer M, Bley T. Initial experience with 64-slice cardiac CT: non-invasive visualization of coronary artery bypass grafts. Eur Heart J. 2006; 27: 976–980.[Abstract/Free Full Text]

153. Salm LP, Bax JJ, Jukema JW, Schuijf JD, Vliegen HW, Lamb HJ, van der Wall EE, de Roos A. Comprehensive assessment of patients after coronary artery bypass grafting by 16-detector-row computed tomography. Am Heart J. 2005; 150: 775–781.[CrossRef][Medline] [Order article via Infotrieve]

154. Malagutti P, Nieman K, Meijboom WB, van Mieghem CA, Pugliese F, Cademartiri F, Mollet NR, Boersma E, de Jaegere PP, de Feyter PJ. Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries. Eur Heart J. 2007; 28: 1879–1885.[Abstract/Free Full Text]

155. Nickoloff EL, Alderson PO. Radiation exposures to patients from CT: reality, public perception, and policy. AJR Am J Roentgenol. 2001; 177: 285–287.[Free Full Text]

156. Delaney A, Carter A, Fisher M. The prevention of anaphylactoid reactions to iodinated radiological contrast media: a systematic review. BMC Med Imaging. 2006; 6: 2.[CrossRef][Medline] [Order article via Infotrieve]

157. Masui T, Katayama M, Kobayashi S, Sakahara H. Intravenous injection of high and medium concentrations of computed tomography contrast media and related heat sensation, local pain, and adverse reactions. J Comput Assist Tomogr. 2005; 29: 704–708.[CrossRef][Medline] [Order article via Infotrieve]

158. Cochran ST. Anaphylactoid reactions to radiocontrast media. Curr Allergy Asthma Rep. 2005; 5: 28–31.[Medline] [Order article via Infotrieve]

159. Laroche D, Vergnaud MC, Lefrancois C, Hue S, Bricard H. Anaphylactoid reactions to iodinated contrast media. Acad Radiol. 2002; 9 (suppl 2): S431–S432.[CrossRef][Medline] [Order article via Infotrieve]

160. Morcos SK, Thomsen HS. Adverse reactions to iodinated contrast media. Eur Radiol. 2001; 11: 1267–1275.[CrossRef][Medline] [Order article via Infotrieve]

161. Spring DB, Bettmann MA, Barkan HE. Nonfatal adverse reactions to iodinated contrast media: spontaneous reporting to the U.S. Food and Drug Administration, 1978–1994. Radiology. 1997; 204: 325–332.[Abstract/Free Full Text]

162. Brenner D, Elliston C, Hall E, Berdon W. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol. 2001; 176: 289–296.[Abstract/Free Full Text]

163. Garcia-Peña P, Lucaya J. HRCT in children: technique and indications. Eur Radiol. 2004; 14 (suppl 4): L13–L30.[CrossRef][Medline] [Order article via Infotrieve]

164. Fayad ZA. MR imaging for the noninvasive assessment of atherothrombotic plaques. Magn Reson Imaging Clin N Am. 2003; 11: 101–113.[CrossRef][Medline] [Order article via Infotrieve]

165. Flamm SD, Muthupillai R. Coronary artery magnetic resonance angiography. J Magn Reson Imaging. 2004; 19: 686–709.[CrossRef][Medline] [Order article via Infotrieve]

166. Flohr T, Stierstorfer K, Raupach R, Ulzheimer S, Bruder H. Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofo. 2004; 176: 1803–1810.[Medline] [Order article via Infotrieve]

167. Gerber TC, Kuzo RS, Karstaedt N, Lane GE, Morin RL, Sheedy PF 2nd, Safford RE, Blackshear JL, Pietan JH. Current results and new developments of coronary angiography with use of contrast-enhanced computed tomography of the heart. Mayo Clin Proc. 2002; 77: 55–71.[Abstract/Free Full Text]

168. Lu B, Dai R, Bai H, He S, Jing B, Zhuang N, Gao R, Yang Y, Chen J, Budoff MJ. Evaluation of electron beam tomographic coronary arteriography with three-dimensional reconstruction in healthy subjects. Angiology. 2000; 51: 895–904.[CrossRef][Medline] [Order article via Infotrieve]

169. Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, McGoon DC, Murphy ML, Roe BB. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation. 1975; 51 (suppl 4): 5–40.[Medline] [Order article via Infotrieve]

170. Mahnken AH, Katoh M, Bruners P, Spuentrup E, Wildberger JE, Gunther RW, Buecker A. Acute myocardial infarction: assessment of left ventricular function with 16-detector row spiral CT versus MR imaging: study in pigs. Radiology. 2005; 236: 112–117.[Abstract/Free Full Text]

171. Falk E, Shah PK, Fuster V. Coronary plaque disruption. Circulation. 1995; 92: 657–671.[Free Full Text]

172. Little WC, Constantinescu M, Applegate RJ, Kutcher MA, Burrows MT, Kahl FR, Santamore WP. Can coronary angiography predict the site of a subsequent myocardial infarction in patients with mild-to-moderate coronary artery disease? Circulation. 1988; 78: 1157–1166.[Abstract/Free Full Text]

173. Naghavi M, Libby P, Falk E, Casscells SW, Litovsky S, Rumberger J, Badimon JJ, Stefanadis C, Moreno P, Pasterkamp G, Fayad Z, Stone PH, Waxman S, Raggi P, Madjid M, Zarrabi A, Burke A, Yuan C, Fitzgerald PJ, Siscovick DS, de Korte CL, Aikawa M, Airaksinen KE, Assmann G, Becker CR, Chesebro JH, Farb A, Galis ZS, Jackson C, Jang IK, Koenig W, Lodder RA, March K, Demirovic J, Navab M, Priori SG, Rekhter MD, Bahr R, Grundy SM, Mehran R, Colombo A, Boerwinkle E, Ballantyne C, Insull W Jr, Schwartz RS, Vogel R, Serruys PW, Hansson GK, Faxon DP, Kaul S, Drexler H, Greenland P, Muller JE, Virmani R, Ridker PM, Zipes DP, Shah PK, Willerson JT. From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: part I. Circulation. 2003; 108: 1664–1672.[Abstract/Free Full Text]

174. Stary HC, Chandler AB, Dinsmore RE, Fuster V, Glagov S, Insull W Jr, Rosenfeld ME, Schwartz CJ, Wagner WD, Wissler RW. A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Circulation. 1995; 92: 1355–1374.[Abstract/Free Full Text]

175. Rasouli ML. CT imaging of non-calcific atherosclerotic plaque with cardiac computed tomography. In: Budoff MJ, Shinbane JS, eds. Cardiac CT Imaging: Diagnosis of Cardiovascular Disease. London: Springer; 2006: 165–172.

176. Budoff MJ. Prevalence of soft plaque detection with computed tomography. J Am Coll Cardiol. 2006; 48: 319–321.[Free Full Text]

177. Achenbach S, Moselewski F, Ropers D, Ferencik M, Hoffmann U, MacNeill B, Pohle K, Baum U, Anders K, Jang IK, Daniel WG, Brady TJ. Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound. Circulation. 2004; 109: 14–17.[Abstract/Free Full Text]

178. Kim WY, Stuber M, Börnert P, Kissinger KV, Manning WJ, Botnar RM. Three-dimensional black-blood cardiac magnetic resonance coronary vessel wall imaging detects positive arterial remodeling in patients with nonsignificant coronary artery disease. Circulation. 2002; 106: 296–299.[Abstract/Free Full Text]

179. Leber AW, Becker A, Knez A, von Ziegler F, Sirol M, Nikolaou K, Ohnesorge B, Fayad ZA, Becker CR, Reiser M, Steinbeck G, Boekstegers P. Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol. 2006; 47: 672–677.[Abstract/Free Full Text]

180. Baumgart D, Schmermund A, Goerge G, Haude M, Ge J, Adamzik M, Sehnert C, Altmaier K, Groenemeyer D, Seibel R, Erbel R. Comparison of electron beam computed tomography with intracoronary ultrasound and coronary angiography for detection of coronary atherosclerosis. J Am Coll Cardiol. 1997; 30: 57–64.[Abstract]

181. Leber AW, Knez A, Becker A, Becker C, von Ziegler F, Nikolaou K, Rist C, Reiser M, White C, Steinbeck G, Boekstegers P. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol. 2004; 43: 1241–1247.[Abstract/Free Full Text]

182. Rasouli MLSD, McKay C, French WJ, Budoff MJ. Electron beam angiography in the assessment of coronary plaque morphology. Catheter Cardiovasc Interv. 2004; 62: A3.

183. Schoenhagen P, Tuzcu EM, Stillman AE, Moliterno DJ, Halliburton SS, Kuzmiak SA, Kasper JM, Magyar WA, Lieber ML, Nissen SE, White RD. Non-invasive assessment of plaque morphology and remodeling in mildly stenotic coronary segments: comparison of 16-slice computed tomography and intravascular ultrasound. Coron Artery Dis. 2003; 14: 459–462.[CrossRef][Medline] [Order article via Infotrieve]

184. Schroeder S, Kopp AF, Baumbach A, Meisner C, Kuettner A, Georg C, Ohnesorge B, Herdeg C, Claussen CD, Karsch KR. Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol. 2001; 37: 1430–1435.[Abstract/Free Full Text]

185. Moselewski F, Ropers D, Pohle K, Hoffmann U, Ferencik M, Chan RC, Cury RC, Abbara S, Jang IK, Brady TJ, Daniel WG, Achenbach S. Comparison of measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multidetector computed tomography versus intravascular ultrasound. Am J Cardiol. 2004; 94: 1294–1297.[CrossRef][Medline] [Order article via Infotrieve]

186. Budoff MJ, Achenbach S, Blumenthal RS, Carr JJ, Goldin JG, Greenland P, Guerci AD, Lima JA, Rader DJ, Rubin GD, Shaw LJ, Wiegers SE. Assessment of coronary artery disease by cardiac computed tomography: a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology. Circulation. 2006; 114: 1761–1791.[Free Full Text]

187. Botnar RM, Kim WY, Börnert P, Stuber M, Spuentrup E, Manning WJ. 3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition. Magn Reson Med. 2001; 46: 848–854.[CrossRef][Medline] [Order article via Infotrieve]

188. von Ingersleben G, Schmiedl UP, Hatsukami TS, Nelson JA, Subramaniam DS, Ferguson MS, Yuan C. Characterization of atherosclerotic plaques at the carotid bifurcation: correlation of high-resolution MR imaging with histologic analysis: preliminary study. Radiographics. 1997; 17: 1417–1423.[Abstract]

189. Fayad ZA, Nahar T, Fallon JT, Goldman M, Aguinaldo JG, Badimon JJ, Shinnar M, Chesebro JH, Fuster V. In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography. Circulation. 2000; 101: 2503–2509.[Abstract/Free Full Text]

190. Edelman RR, Mattle HP, Wallner B, Bajakian R, Kleefield J, Kent C, Skillman JJ, Mendel JB, Atkinson DJ. Extracranial carotid arteries: evaluation with "black blood" MR angiography. Radiology. 1990; 177: 45–50.[Abstract/Free Full Text]

191. Shunk KA, Garot J, Atalar E, Lima JA. Transesophageal magnetic resonance imaging of the aortic arch and descending thoracic aorta in patients with aortic atherosclerosis. J Am Coll Cardiol. 2001; 37: 2031–2035.[Abstract/Free Full Text]

192. Hatsukami TS, Ross R, Polissar NL, Yuan C. Visualization of fibrous cap thickness and rupture in human atherosclerotic carotid plaque in vivo with high-resolution magnetic resonance imaging. Circulation. 2000; 102: 959–964.[Abstract/Free Full Text]

193. Chan SK, Jaffer FA, Botnar RM, Kissinger KV, Goepfert L, Chuang ML, O'Donnell CJ, Levy D, Manning WJ. Scan reproducibility of magnetic resonance imaging assessment of aortic atherosclerosis burden. J Cardiovasc Magn Reson. 2001; 3: 331–338.[CrossRef][Medline] [Order article via Infotrieve]

194. Yuan C, Mitsumori LM, Ferguson MS, Polissar NL, Echelard D, Ortiz G, Small R, Davies JW, Kerwin WS, Hatsukami TS. In vivo accuracy of multispectral magnetic resonance imaging for identifying lipid-rich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques. Circulation. 2001; 104: 2051–2056.[Abstract/Free Full Text]

195. Kramer CM. Magnetic resonance imaging to identify the high-risk plaque. Am J Cardiol. 2002; 90: 15L–17L.[CrossRef][Medline] [Order article via Infotrieve]

196. Yuan C, Beach KW, Smith LH Jr, Hatsukami TS. Measurement of atherosclerotic carotid plaque size in vivo using high resolution magnetic resonance imaging. Circulation. 1998; 98: 2666–2671.[Abstract/Free Full Text]

197. Luo Y, Polissar N, Han C, Yarnykh V, Kerwin WS, Hatsukami TS, Yuan C. Accuracy and uniqueness of three in vivo measurements of atherosclerotic carotid plaque morphology with black blood MRI. Magn Reson Med. 2003; 50: 75–82.[CrossRef][Medline] [Order article via Infotrieve]

198. Newman AB, Naydeck B, Sutton-Tyrrell K, Edmundowicz D, Gottdiener J, Kuller LH. Coronary artery calcification in older adults with minimal clinical or subclinical cardiovascular disease. J Am Geriatr Soc. 2000; 48: 256–263.[Medline] [Order article via Infotrieve]

199. Toussaint JF, Southern JF, Fuster V, Kantor HL. T2-weighted contrast for NMR characterization of human atherosclerosis. Arterioscler Thromb Vasc Biol. 1995; 15: 1533–1542.[Medline] [Order article via Infotrieve]

200. Li D, Dolan RP, Walovitch RC, Lauffer RB. Three-dimensional MRI of coronary arteries using an intravascular contrast agent. Magn Reson Med. 1998; 39: 1014–1018.[Medline] [Order article via Infotrieve]

201. Stillman AE, Wilke N, Jerosch-Herold M. Use of an intravascular T1 contrast agent to improve MR cine myocardial-blood pool definition in man. J Magn Reson Imaging. 1997; 7: 765–767.[Medline] [Order article via Infotrieve]

202. Taylor AM, Panting JR, Keegan J, Gatehouse PD, Amin D, Jhooti P, Yang GZ, McGill S, Burman ED, Francis JM, Firmin DN, Pennell DJ. Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography. J Magn Reson Imaging. 1999; 9: 220–227.[CrossRef][Medline] [Order article via Infotrieve]

203. Huber ME, Paetsch I, Schnackenburg B, Bornstedt A, Nagel E, Fleck E, Boesiger P, Maggioni F, Cavagna FM, Stuber M. Performance of a new gadolinium-based intravascular contrast agent in free-breathing inversion-recovery 3D coronary MRA. Magn Reson Med. 2003; 49: 115–121.[CrossRef][Medline] [Order article via Infotrieve]

204. Kim WY, Stuber M, Kissinger KV, Andersen NT, Manning WJ, Botnar RM. Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging. J Magn Reson Imaging. 2001; 14: 383–390.[CrossRef][Medline] [Order article via Infotrieve]

205. Herborn CU, Barkhausen J, Paetsch I, Hunold P, Mahler M, Shamsi K, Nagel E. Coronary arteries: contrast-enhanced MR imaging with SH L 643A: experience in 12 volunteers. Radiology. 2003; 229: 217–223.[Abstract/Free Full Text]

206. Manning WJ, Li W, Edelman RR. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med. 1993; 328: 828–832.[Abstract/Free Full Text]

207. Pennell DJ, Bogren HG, Keegan J, Firmin DN, Underwood SR. Assessment of coronary artery stenosis by magnetic resonance imaging. Heart. 1996; 75: 127–133.[Abstract/Free Full Text]

208. Post JC, van Rossum AC, Hofman MB, de Cock CC, Valk J, Visser CA. Clinical utility of two-dimensional magnetic resonance angiography in detecting coronary artery disease. Eur Heart J. 1997; 18: 426–433.[Abstract/Free Full Text]

209. Woodard PK, Li D, Haacke EM, Dhawale PJ, Kaushikkar S, Barzilai B, Braverman AC, Ludbrook PA, Weiss AN, Brown JJ, Mirowitz SA, Pilgram TK, Gutierrez FR. Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: preliminary experience. AJR Am J Roentgenol. 1998; 170: 883–888.[Abstract/Free Full Text]

210. Kessler W, Achenbach S, Moshage W, Zink D, Kroeker R, Nitz W, Laub G, Bachmann K. Usefulness of respiratory gated magnetic resonance coronary angiography in assessing narrowings > or = 50% in diameter in native coronary arteries and in aortocoronary bypass conduits. Am J Cardiol. 1997; 80: 989–993.[CrossRef][Medline] [Order article via Infotrieve]

211. Sandstede JJ, Pabst T, Beer M, Geis N, Kenn W, Neubauer S, Hahn D. Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography. AJR Am J Roentgenol. 1999; 172: 135–139.[Abstract/Free Full Text]

212. van Geuns RJ, de Bruin HG, Rensing BJ, Wielopolski PA, Hulshoff MD, van Ooijen PM, Oudkerk M, de Feyter PJ. Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique. Heart. 1999; 82: 515–519.[Abstract/Free Full Text]

213. Huber A, Nikolaou K, Gonschior P, Knez A, Stehling M, Reiser M. Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: results from healthy volunteers and patients with proximal coronary artery stenoses. AJR Am J Roentgenol. 1999; 173: 95–101.[Abstract/Free Full Text]

214. Sardanelli F, Molinari G, Zandrino F, Balbi M. Three-dimensional, navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference. Radiology. 2000; 214: 808–814.[Abstract/Free Full Text]

215. Wittlinger T, Voigtländer T, Rohr M, Meyer J, Thelen M, Kreitner KF, Kalden P. Magnetic resonance imaging of coronary artery occlusions in the navigator technique. Int J Cardiovasc Imaging. 18: 203–215.

216. Kim WY, Danias PG, Stuber M, Flamm SD, Plein S, Nagel E, Langerak SE, Weber OM, Pedersen EM, Schmidt M, Botnar RM, Manning WJ. Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med. 2001; 345: 1863–1869.[Abstract/Free Full Text]

217. Weber C, Steiner P, Sinkus R, Dill T, Börnert P, Adam G. Correlation of 3D MR coronary angiography with selective coronary angiography: feasibility of the motion-adapted gating technique. Eur Radiol. 2002; 12: 718–726.[CrossRef][Medline] [Order article via Infotrieve]

218. Jahnke C, Paetsch I, Nehrke K, Schnackenburg B, Gebker R, Fleck E, Nagel E. Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance. Eur Heart J. 2005; 26: 2313–2319.[Abstract/Free Full Text]

219. Regenfus M, Ropers D, Achenbach S, Kessler W, Laub G, Daniel WG, Moshage W. Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography. J Am Coll Cardiol. 2000; 36: 44–50.[Abstract/Free Full Text]

220. Rubinstein RI, Askenase AD, Thickman D, Feldman MS, Agarwal JB, Helfant RH. Magnetic resonance imaging to evaluate patency of aortocoronary bypass grafts. Circulation. 1987; 76: 786–791.[Abstract/Free Full Text]

221. Jenkins JP, Love HG, Foster CJ, Isherwood I, Rowlands DJ. Detection of coronary artery bypass graft patency as assessed by magnetic resonance imaging. Br J Radiol. 1988; 61: 2–4.[Abstract/Free Full Text]

222. Garcia MJ, Lessick J, Hoffmann MH, CATSCAN Study Investigators. Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA. 2006; 296: 403–411.[Abstract/Free Full Text]

223. Cordeiro MA, Miller JM, Schmidt A, Lardo AC, Rosen BD, Bush DE, Brinker JA, Bluemke DA, Shapiro EP, Lima JA. Non-invasive half millimetre 32 detector row computed tomography angiography accurately excludes significant stenoses in patients with advanced coronary artery disease and high calcium scores. Heart. 2006; 92: 589–597.[Abstract/Free Full Text]

224. Nikolaou K, Knez A, Rist C, Wintersperger BJ, Leber A, Johnson T, Reiser MF, Becker CR. Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. AJR Am J Roentgenol. 2006; 187: 111–117.[Abstract/Free Full Text]

225. Schlosser T, Mohrs OK, Magedanz A, Nowak B, Voigtländer T, Barkhausen J, Schmermund A. Noninvasive coronary angiography using 64-detector-row computed tomography in patients with a low to moderate pretest probability of significant coronary artery disease. Acta Radiol. 2007; 48: 300–307.[CrossRef][Medline] [Order article via Infotrieve]

226. Muhlenbruch G, Seyfarth T, Soo CS, Pregalathan N, Mahnken AH. Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients. Eur Radiol. 2007; 17: 603–609.[CrossRef][Medline] [Order article via Infotrieve]

227. Meijboom WB, Mollet NR, Van Mieghem CA, Weustink AC, Pugliese F, van Pelt N, Cademartiri F, Vourvouri E, de Jaegere P, Krestin GP, de Feyter PJ. 64-Slice CT coronary angiography in patients with non-ST elevation acute coronary syndrome. Heart. 2007; 93: 1386–1392.[Abstract/Free Full Text]

228. Schuijf JD, Pundziute G, Jukema JW, Lamb HJ, van der Hoeven BL, de Roos A, van der Wall EE, Bax JJ. Diagnostic accuracy of 64-slice multislice computed tomography in the noninvasive evaluation of significant coronary artery disease. Am J Cardiol. 2006; 98: 145–148.[CrossRef][Medline] [Order article via Infotrieve]

229. Oncel D, Oncel G, Tastan A, Tamci B. Detection of significant coronary artery stenosis with 64-section MDCT angiography. Eur J Radiol. 2007; 62: 394–405.[CrossRef][Medline] [Order article via Infotrieve]

230. Herzog C, Zwerner PL, Doll JR, Nielsen CD, Nguyen SA, Savino G, Vogl TJ, Costello P, Schoepf UJ. Significant coronary artery stenosis: comparison on per-patient and per-vessel or per-segment basis at 64-section CT angiography. Radiology. 2007; 244: 112–120.[Abstract/Free Full Text]

231. Ehara M, Kawai M, Surmely JF, Matsubara T, Terashima M, Tsuchikane E, Kinoshita Y, Ito T, Takeda Y, Nasu K, Tanaka N, Murata A, Fujita H, Sato K, Kodama A, Katoh O, Suzuki T. Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography: comparison with invasive coronary angiography. J Am Coll Cardiol. 2007; 49: 951–959.[Abstract/Free Full Text]

232. Shabestari AA, Abdi S, Akhlaghpoor S, Azadi M, Baharjoo H, Pajouh MD, Emami Z, Esfahani F, Firouzi I, Hashemian M, Kouhi M, Mozafari M, Nazeri I, Rohshani M, Salevatipour B, Tavalla H, Tehrai M, Zarrabi A. Diagnostic performance of 64-channel multislice computed tomography in assessment of significant coronary artery disease in symptomatic subjects. Am J Cardiol. 2007; 99: 1656–1661.[CrossRef][Medline] [Order article via Infotrieve]

233. Cademartiri F, Maffei E, Palumbo A, Malagò R, Alberghina F, Aldrovandi A, Brambilla V, Runza G, La Grutta L, Menozzi A, Vignali L, Casolo G, Midiri M, Mollet NR. Diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low-to-intermediate risk. Radiol Med (Torino). 2007; 112: 969–981.[CrossRef][Medline] [Order article via Infotrieve]

234. Hausleiter J, Meyer T, Hadamitzky M, Zankl M, Gerein P, Dörrler K, Kastrati A, Martinoff S, Schömig A. Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial. Eur Heart J. 2007; 28: 3034–3041.[Abstract/Free Full Text]

235. Meijboom WB, van Mieghem CA, Mollet NR, Pugliese F, Weustink AC, van Pelt N, Cademartiri F, Nieman K, Boersma E, de Jaegere P, Krestin GP, de Feyter PJ. 64-Slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease. J Am Coll Cardiol. 2007; 50: 1469–1475.[Abstract/Free Full Text]

236. Andreini D, Pontone G, Pepi M, Ballerini G, Bartorelli AL, Magini A, Quaglia C, Nobili E, Agostoni P. Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with dilated cardiomyopathy. J Am Coll Cardiol. 2007; 49: 2044–2050.[Abstract/Free Full Text]

237. Pundziute G, Schuijf JD, Jukema JW, van Werkhoven JM, Boersma E, de Roos A, van der Wall EE, Bax JJ. Gender influence on the diagnostic accuracy of 64-slice multislice computed tomography coronary angiography for detection of obstructive coronary artery disease. Heart. 2008; 94: 48–52.[Abstract/Free Full Text]

238. Weustink AC, Meijboom WB, Mollet NR, Otsuka M, Pugliese F, van Mieghem C, Malago R, van Pelt N, Dijkshoorn ML, Cademartiri F, Krestin GP, de Feyter PJ. Reliable high-speed coronary computed tomography in symptomatic patients. J Am Coll Cardiol. 2007; 50: 786–794.[Abstract/Free Full Text]

239. Leber AW, Johnson T, Becker A, von Ziegler F, Tittus J, Nikolaou K, Reiser M, Steinbeck G, Becker CR, Knez A. Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease. Eur Heart J. 2007; 28: 2354–2360.[Abstract/Free Full Text]

240. Scheffel H, Alkadhi H, Plass A, Vachenauer R, Desbiolles L, Gaemperli O, Schepis T, Frauenfelder T, Schertler T, Husmann L, Grunenfelder J, Genoni M, Kaufmann PA, Marincek B, Leschka S. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol. 2006; 16: 2739–2747.[CrossRef][Medline] [Order article via Infotrieve]

241. Oncel D, Oncel G, Tastan A. Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: initial experience. Radiology. 2007; 245: 703–711.[Abstract/Free Full Text]

242. Johnson TR, Nikolaou K, Busch S, Leber AW, Becker A, Wintersperger BJ, Rist C, Knez A, Reiser MF, Becker CR. Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease. Invest Radiol. 2007; 42: 684–691.[CrossRef][Medline] [Order article via Infotrieve]

243. Ropers U, Ropers D, Pflederer T, Anders K, Kuettner A, Stilianakis NI, Komatsu S, Kalender W, Bautz W, Daniel WG, Achenbach S. Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol. 2007; 50: 2393–2398.[Abstract/Free Full Text]

244. Heuschmid M, Burgstahler C, Reimann A, Brodoefel H, Mysal I, Haeberle E, Tsiflikas I, Claussen CD, Kopp AF, Schroeder S. Usefulness of noninvasive cardiac imaging using dual-source computed tomography in an unselected population with high prevalence of coronary artery disease. Am J Cardiol. 2007; 100: 587–592.[CrossRef][Medline] [Order article via Infotrieve]

245. Meyer TS, Martinoff S, Hadamitzky M, Will A, Kastrati A, Schömig A, Hausleiter J. Improved noninvasive assessment of coronary artery bypass grafts with 64-slice computed tomographic angiography in an unselected patient population. J Am Coll Cardiol. 2007; 49: 946–950.[Abstract/Free Full Text]

246. Onuma Y, Tanabe K, Chihara R, Yamamoto H, Miura Y, Kigawa I, Fukuda S, Miyairi T, Nakajima H, Hara K. Evaluation of coronary artery bypass grafts and native coronary arteries using 64-slice multidetector computed tomography. Am Heart J. 2007; 154: 519–526.[CrossRef][Medline] [Order article via Infotrieve]

247. Feuchtner GM, Schachner T, Bonatti J, Friedrich GJ, Soegner P, Klauser A, zur Nedden D. Diagnostic performance of 64-slice computed tomography in evaluation of coronary artery bypass grafts. AJR Am J Roentgenol. 2007; 189: 574–580.[Abstract/Free Full Text]

248. Ropers D, Pohle FK, Kuettner A, Pflederer T, Anders K, Daniel WG, Bautz W, Baum U, Achenbach S. Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation. Circulation. 2006; 114: 2334–2341.[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
CirculationHome page
D. J. Pennell
Cardiovascular Magnetic Resonance
Circulation, February 9, 2010; 121(5): 692 - 705.
[Full Text] [PDF]


Home page
RadiologyHome page
J. A. Rocha-Filho, R. Blankstein, L. D. Shturman, H. G. Bezerra, D. R. Okada, I. S. Rogers, B. Ghoshhajra, U. Hoffmann, G. Feuchtner, W. S. Mamuya, et al.
Incremental Value of Adenosine-induced Stress Myocardial Perfusion Imaging with Dual-Source CT at Cardiac CT Angiography
Radiology, February 1, 2010; 254(2): 410 - 419.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. J. Kilner, T. Geva, H. Kaemmerer, P. T. Trindade, J. Schwitter, and G. D. Webb
Recommendations for cardiovascular magnetic resonance in adults with congenital heart disease from the respective working groups of the European Society of Cardiology
Eur. Heart J., January 11, 2010; (2010) ehp586v1.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. D. Karamitsos, J. M. Francis, S. Myerson, J. B. Selvanayagam, and S. Neubauer
The Role of Cardiovascular Magnetic Resonance Imaging in Heart Failure
J. Am. Coll. Cardiol., October 6, 2009; 54(15): 1407 - 1424.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Dewey, E. Zimmermann, F. Deissenrieder, M. Laule, H.-P. Dubel, P. Schlattmann, F. Knebel, W. Rutsch, and B. Hamm
Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy: Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation
Circulation, September 8, 2009; 120(10): 867 - 875.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. H. O'Donnell, S. Abbara, V. Chaithiraphan, K. Yared, R. P. Killeen, R. C. Cury, and J. D. Dodd
Cardiac Tumors: Optimal Cardiac MR Sequences and Spectrum of Imaging Appearances
Am. J. Roentgenol., August 1, 2009; 193(2): 377 - 387.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
R. J. Gibbons and T. C. Gerber
Calcium Scoring With Computed Tomography: What Is the Radiation Risk?
Arch Intern Med, July 13, 2009; 169(13): 1185 - 1187.
[Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
P. S. Douglas, A. Taylor, D. Bild, R. Bonow, P. Greenland, M. Lauer, F. Peacock, and J. Udelson
Outcomes Research in Cardiovascular Imaging: Report of a Workshop Sponsored by the National Heart, Lung, and Blood Institute
J. Am. Coll. Cardiol. Img., July 1, 2009; 2(7): 897 - 907.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
P. S. Douglas, A. Taylor, D. Bild, R. Bonow, P. Greenland, M. Lauer, F. Peacock, and J. Udelson
Outcomes Research in Cardiovascular Imaging: Report of a Workshop Sponsored by the National Heart, Lung, and Blood Institute
Circ Cardiovasc Imaging, July 1, 2009; 2(4): 339 - 348.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Motoyama, M. Sarai, H. Harigaya, H. Anno, K. Inoue, T. Hara, H. Naruse, J. Ishii, H. Hishida, N. D. Wong, et al.
Computed tomographic angiography characteristics of atherosclerotic plaques subsequently resulting in acute coronary syndrome.
J. Am. Coll. Cardiol., June 30, 2009; 54(1): 49 - 57.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. R. Conti
Coronary Angiography: Catheter Based or Computed Tomography Based
J. Am. Coll. Cardiol., June 23, 2009; 53(25): 2405 - 2406.
[Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
S. Achenbach, V. Dilsizian, C. M. Kramer, and W. A. Zoghbi
The Year in Coronary Artery Disease
J. Am. Coll. Cardiol. Img., June 1, 2009; 2(6): 774 - 786.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. R. Mayo and J. A. Leipsic
Radiation Dose in Cardiac CT
Am. J. Roentgenol., March 1, 2009; 192(3): 646 - 653.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. C. Gerber, J. J. Carr, A. E. Arai, R. L. Dixon, V. A. Ferrari, A. S. Gomes, G. V. Heller, C. H. McCollough, M. F. McNitt-Gray, F. A. Mettler, et al.
Ionizing Radiation in Cardiac Imaging: A Science Advisory From the American Heart Association Committee on Cardiac Imaging of the Council on Clinical Cardiology and Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention
Circulation, February 24, 2009; 119(7): 1056 - 1065.
[Full Text] [PDF]


Home page
ESC Textbook of Cardiovascular MedicineHome page
P. J. de Feyter, S. Achenbach, and K. Nieman
CHAPTER 6 Cardiovascular Computed Tomography
ESC Textbook of Cardiovascular Medicine, January 1, 2009; 2(1): med-9780199566990-chapter - med-9780199566990-chapter.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
A. Schmermund, B. Nowak, and T. Voigtlander
Non-invasive CT coronary angiography: can high diagnostic image quality be achieved with less radiation exposure?
Eur. Heart J., December 2, 2008; 29(24): 2955 - 2956.
[Full Text] [PDF]


Home page
Eur Heart JHome page
P. Schoenhagen and E. M. Tuzcu
Identifying patterns of atherosclerotic disease manifestation with coronary computed tomography. Impact on clinical management and outcome?
Eur. Heart J., October 1, 2008; 29(19): 2323 - 2324.
[Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
P. J. de Feyter and R.-J. van Geuns
Noninvasive Coronary Imaging: The Contest Between Magnetic Resonance and Computed Tomographic Coronary Angiography
Circ Cardiovasc Imaging, September 1, 2008; 1(2): 89 - 91.
[Full Text] [PDF]


This Article
Free upon publication Free Article
Right arrow Extract
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
118/5/586    most recent
CIRCULATIONAHA.108.189695v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bluemke, D. A.
Right arrow Articles by Woodard, P. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bluemke, D. A.
Right arrow Articles by Woodard, P. K.
Related Collections
Right arrow AHA Statements and Guidelines