Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2008;118:1155-1162
Published online before print August 25, 2008, doi: 10.1161/CIRCULATIONAHA.107.758698
CLINICAL PERSPECTIVE
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
118/11/1155    most recent
CIRCULATIONAHA.107.758698v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kelbæk, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kelbæk, H.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Heart Attack
Related Collections
Right arrow Restenosis
Right arrow Catheter-based coronary interventions: stents
Right arrow Acute myocardial infarction
Right arrowRelated Article

(Circulation. 2008;118:1155-1162.)
© 2008 American Heart Association, Inc.


Interventional Cardiology

Drug-Eluting Versus Bare Metal Stents in Patients With ST-Segment–Elevation Myocardial Infarction

Eight-Month Follow-Up in the Drug Elution and Distal Protection in Acute Myocardial Infarction (DEDICATION) Trial

Henning Kelbæk, MD; Leif Thuesen, MD; Steffen Helqvist, MD; Peter Clemmensen, MD; Lene Kløvgaard, RN; Anne Kaltoft, MD; Bente Andersen, RN; Helle Thuesen, RN; Thomas Engstrøm, MD; Hans E. Bøtker, MD; Kari Saunamäki, MD; Lars R. Krusell, MD; Erik Jørgensen, MD; Hans-Henrik T. Hansen, MD; Evald H. Christiansen, MD; Jan Ravkilde, MD; Lars Køber, MD; Klaus F. Kofoed, MD; Christian J. Terkelsen, MD; Jens F. Lassen, MD, for the DEDICATION Investigators*

From the Medical Department B and Cardiac Catheterization Laboratory, Rigshospitalet, University of Copenhagen (H.K., S.H., P.C., L.K., B.A., T.E., K.S., E.J., H.-H.T.H., L.K., K.F.K.), and Department of Cardiology, Aarhus University Hospital, Skejby (L.T., A.K., H.T., H.E.B., L.R.K., E.H.C., J.R., C.J.T., J.F.L.), Denmark.

Correspondence to Henning Kelbæk, MD, Cardiac Catheterization Laboratory 2013, Rigshospitalet, 9 Blegdamsvej, DK-2100 Copenhagen Ø, Denmark. E-mail henning.kelbaek{at}rh.regionh.dk

Received October 5, 2007; accepted June 3, 2008.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowConclusions
down arrowAppendix
down arrowReferences
 
Background— Implantation of drug-eluting stents (DES) limits the rate of coronary restenosis in most patients with coronary artery disease, but data are scarce with regard to their use in patients with ST-segment–elevation myocardial infarction and in connection with distal protection of the microvascular perfusion during primary percutaneous coronary intervention.

Methods and Results— We randomly assigned 626 patients referred within 12 hours from symptom onset of an ST-elevation myocardial infarction to have a DES or a bare metal stent implanted in the infarct-related lesion with or without distal protection during primary percutaneous coronary intervention. Quantitative coronary angiography was performed during the index treatment and 8 months later. The primary end point was loss of the lumen diameter in the infarct-related lesion induced by neointimal proliferation. Patients were comparable with regard to baseline demographic and angiographic characteristics. The mean late lumen loss was significantly lower in patients treated with a DES (0.06 mm; SD, 0.66 mm) than in patients who had a bare metal stent implanted (0.47 mm; SD, 0.69 mm; P<0.001). The rate of the composite end point of cardiac death, recurrent myocardial infarction, and target lesion revascularization was 8.6% in the DES group versus 14.4% in the bare metal stent group (P=0.03). Cardiac death occurred in 4.2% and 1.6% of the patients (P=0.09) and stent thrombosis occurred in 2.0% and 2.6% (P=0.72), respectively.

Conclusion— Implantation of DES improves the angiographic outcome and need for repeat revascularization without increasing the short-term risk of stent thrombosis but has a tendency to increase cardiac death in patients with ST-segment–elevation myocardial infarction.


Key Words: angioplasty • coronary disease • myocardial infarction • restenosis • stents


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowConclusions
down arrowAppendix
down arrowReferences
 
Primary percutaneous coronary intervention, including stent implantation, has become the treatment of choice in patients with ST-segment–elevation myocardial infarction when performed within 12 hours after the onset of symptoms, even if it involves transporting the patient from a referring hospital, provided it can be performed within 90 minutes after first medical contact.1–4 Drug-eluting stents (DES) improve the angiographic and clinical outcomes in most patients. However, only a few larger randomized studies have been undertaken to evaluate the effect and safety of the use of DES in patients with ST-segment–elevation myocardial infarction,5–7 and the clinical results of these trials have not been consistent. In addition, inclusion criteria were rather strict in previous trials.

Clinical Perspective p 1162

Abrupt closure of an epicardial coronary vessel usually occurs in a large vessel and in an area of a vulnerable plaque with necrotic lipid cores and low-grade stenosis,8 and the vascular response to implantation of a DES in such an area could be considerably different from the response occurring in a smaller vessel and a high-grade stable lesion.9 Late angiographic evaluation after implantation of DES compared with bare metal stents (BMS) in patients with ST-segment–elevation myocardial infarction has been reported in only a few patients.6

The present study was designed to evaluate whether implantation of DES currently used for other categories of patients with coronary artery disease reduces neointimal proliferation in the infarct-related lesion and thereby improves clinical outcome compared with BMS in a rather unselected group of patients with ST-segment–elevation myocardial infarction. Because it was unclear whether protection of the microcirculation during primary percutaneous coronary intervention improves outcome,10–12 patients were also randomized to treatment with or without distal protection using a filter wire system.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowConclusions
down arrowAppendix
down arrowReferences
 
Study Design and Patients
The Drug Elution and Distal Protection in ST-Segment–Elevation Myocardial Infarction (DEDICATION) trial was a randomized study evaluating the effect of implantation of DES or BMS with or without distal protection during primary percutaneous coronary intervention conducted at 2 high-volume invasive cardiology centers in Denmark. The study protocol was approved by the local ethics committees, and all patients gave written informed consent before inclusion.

We enrolled patients with chest pain of >30-minute duration who had a cumulated ST-segment elevation of >4 mm in at least 2 contiguous leads of the ECG, provided that they were >18 years of age and had a high-grade stenosis or occlusion of a coronary artery without excessive tortuosity or calcification prohibiting advancement of a filter wire to the distal vascular bed of the vessel. We did not distinguish between patients who were admitted directly to the tertiary unit with laboratory facilities or via a referring hospital as long as they presented to the catheterization laboratory within 12 hours from symptom onset. Exclusion criteria were previous myocardial infarction in the target vessel area, development of cardiogenic shock before enrollment, culprit lesions in an unprotected left main coronary artery, gastrointestinal bleeding within 1 month, pregnancy, known renal failure, life expectancy <1 year, and linguistic problems.

Randomization and Study Procedures
Patients were pretreated with 300 to 500 mg aspirin, 300 to 600 mg clopidogrel, and 10 000 IU unfractionated heparin as soon as transportation to the catheterization laboratory was arranged. A β-blocker was administered at the discretion of the transportation team according to blood pressure and heart rate. If there was no contraindication, patients were treated with a glycoprotein IIb/IIIa receptor blocker on arrival at the catheterization laboratory. Coronary angiography was performed, and the culprit lesion was identified. A guidewire was advanced through the highly stenosed or occluded lesion, and if the peripheral vascular bed was not visible, dilatation with a 1.5- to 2.0-mm-diameter balloon was allowed to visualize the coronary artery distal to the lesion. Central telephone (simple) randomization was performed by computerized assignment stratified with regard to sex and the presence of diabetes. Patients were randomly assigned to treatment with or without distal protection and to receive a DES or a BMS in the infarct-related lesion. All stents were implanted under high pressure (>12 atm). Implantation of >1 stent of the same kind was allowed to cover the entire lesion. Both operator and patient were aware of the assigned treatment.

Follow-Up Schedule
Patients were examined during and after the index procedure with ST-segment monitoring, cardiac markers, and echocardiography. At discharge, patients received a daily dose of a statin, clopidogrel (for 12 months), and aspirin (indefinitely). A β-blocker was administered in the absence of contraindications, and an angiotensin-converting enzyme inhibitor was given in case of reduced (<45%) left ventricular ejection fraction. Clinical follow-up was performed at 1 and 6 months to evaluate symptoms of restenosis and the occurrence of major adverse cardiac and cerebral events. Angiographic follow-up was scheduled at 8 months. A clinically driven angiography performed 4 to 8 months after the index treatment replaced the scheduled angiography. Target lesion revascularization (TLR) was indicated in cases of recurrent angina and a diameter stenosis >50% or a diameter stenosis >70% if the patient had no angina.

Quantitative Coronary Angiography Analysis
Angiograms of the infarct-related lesion were acquired immediately after the index procedure and 8 months later using identical projections. Quantitative analysis was performed with the MEDIS computerized edge-detection system by operators blinded to treatment assignments.13,14 The minimal lumen diameter was recorded within the stent margins (in-stent) and 5 mm proximally and distally to the stent (in-lesion). The reference diameter was determined with an interpolated edge-detection technique. Late lumen loss was calculated as the difference between the minimal lumen diameter immediately after the index procedure and at 8 months. Diameter stenosis was calculated as follows: (1–minimal lumen diameter/reference diameter)x100%. A diameter stenosis >50% was characterized as a binary restenosis.

Study End Points and Definitions
The primary end point of the study was the late lumen loss in the infarct-related lesion as determined by quantitative coronary angiography (see above). Secondary end points were the rate of major adverse cardiac events occurring within 8 months after treatment (cardiac death, nonfatal recurrent myocardial infarction, and TLR), development of binary restenosis, clinically driven TLR, and target vessel revascularization.

A recurrent myocardial infarction was defined as a total creatine kinase elevation ≥2 times the upper limit of normal with a concomitant increase in creatine kinase-MB concentration in the presence of an acute coronary syndrome, and reinfarction was present if the recurrent myocardial infarction could be related (by ECG or angiography) to the target vessel. Stroke was defined as the development of disabling neurological symptoms and objective findings lasting >24 hours. Clinically driven TLR was defined as percutaneous or surgical revascularization of the target lesion in the presence of recurrent angina and a significant stenosis/occlusion of the infarct-related lesion. Nonclinically driven TLR was allowed in the absence of angina when the diameter restenosis was >70%. Target vessel revascularization was defined as revascularization either in the target lesion or in an area remote from the target lesion in the same coronary artery. The Clinical Events Committee adjudicated all serious events and stent thromboses according to current definitions.15

Statistical Analysis
The trial involved a factorial design evaluating the effect of treatment with versus without distal protection and implantation of DES versus BMS. With a power of 80% and a 2-sided type I error of 5%, 125 patients were needed in each group to detect a 0.25-mm increase in late lumen loss with an SD of 0.70 mm.16 With an expected 25% rate of patients lost to follow-up, 150 patients were needed in each arm of the study.

Differences in categorical variables were analyzed by the {chi}2 test or by Fisher’s exact test. Continuous variables were analyzed with the Mann–Whitney and Student t tests for unpaired samples. The Kaplan–Meier method was used to create survival estimates, and the log-rank test was used to test differences in these estimates. Interaction analyses were performed by Cox proportional-hazard models including an interaction variable. All probability values were 2 sided.

The authors had full access to and take full responsibility for the integrity of the data. All authors have read and agree to the manuscript as written.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowConclusions
down arrowAppendix
down arrowReferences
 
Patients
Of 1687 screened patients, 626 were enrolled in the trial from May 2005 to November 2006 (Figure 1). Major reasons for exclusion were clinical instability, unconsciousness, unsuitable coronary anatomy, insufficient ST elevation, and participation in another study. The outcome of distal protection versus conventional treatment is published elsewhere.17


Figure 1190689
View larger version (21K):
[in this window]
[in a new window]

 
Figure 1. Flow chart of patients from screening to follow-up. STEMI indicates ST-segment–elevation myocardial infarction; WMI, wall motion index; and MACE, major adverse cardiac events.

Patients in the 2 groups were well matched in terms of baseline clinical and angiographic characteristics (Table 1). The mean age was 63 years; 73% were men; {approx}10% had diabetes; and the median duration from symptom onset to arrival in the catheterization laboratory was {approx}3 hours 20 minutes. The left ventricular ejection fraction measured at discharge was comparable in the 2 groups. Glycoprotein IIb/IIIa receptor blockers were used in >95% of patients, and distal protection was used with success in {approx}40% of the patients in each group (Table 2). All patients received the stent type that they were allocated to, except 3 patients in the DES group (2 were treated with balloon angioplasty alone, and 1 received a BMS) and 8 patients in the BMS group (5 were treated with balloon angioplasty alone, and 3 received a DES). The angiographic and clinical data for these patients were included in the groups to which they were randomly assigned. The diameter and length of the stented segment were similar in the 2 groups, and procedural success was high (Table 2). Of the stents implanted in the DES group, 47% were sirolimus-eluting (Cordis, NJ), 40% were paclitaxel-eluting (Boston Scientific, Natick, Mass), and 13% were zotarolimus-eluting stents (Medtronic, Calif). Among BMS, 38% were made of cobalt alloy (Vision, Abbott, Ill, and Driver, Medtronic), 39% were stainless steel stents from Boston Scientific, and 23% were miscellaneous stainless steel stents from Biotronik (Seoul, South Korea), Cordis, Guidant, Diegem (Belgium), Jomed (Helsingborg, Sweden), and Terumo (Tokyo, Japan). Patients who were excluded from the trial for the above reasons were slightly older, had a higher rate of diabetes and previous myocardial infarction, and had a longer duration of symptom onset to arrival, and 4% had lesions located in the left main stem or saphenous vein grafts (Table 1). As opposed to the included patients, 65% of the excluded patients received a DES, 20% received a BMS, and 15% were treated with balloon angioplasty only.


View this table:
[in this window]
[in a new window]

 
Table 1. Baseline Clinical Characteristics of the Patients and Lesions


View this table:
[in this window]
[in a new window]

 
Table 2. Procedural Results

Quantitative Coronary Angiography
Follow-up angiography was performed in 84% of all patients and in 87% of those who were alive at follow-up. Only data from examined patients were used. Thus, no computations of missing data were performed. The minimal lumen diameter was similar in the 2 groups immediately after the index procedure but significantly larger at follow-up in the DES group (Table 3). Thus, the late lumen loss was 0.06 mm (SD, 0.66 mm) in the lesions of patients treated with a DES compared with 0.47 mm (SD, 0.69 mm) in patients who had received a BMS (P<0.001). The diameter stenosis was less severe in the DES group at follow-up, and the rate of in-lesion binary restenosis was reduced accordingly, from {approx}20% in the BMS to <10% in the DES group (P<0.001). Similar results were found inside the stents (Table 3).


View this table:
[in this window]
[in a new window]

 
Table 3. Quantitative Coronary Angiography

Whereas the reference diameter of the target vessel in patients who had received a DES increased slightly from the index procedure to the 8-month follow-up, the opposite was recorded in patients who had a BMS implanted, with an ensuing 10% difference in reference diameter in the 2 groups (P<0.001). There was no significant interaction between distal protection and stent type.

Clinical Outcomes
The clinical outcomes of the 2 groups are outlined in Figure 2. Sixteen patients in the DES group versus 8 patients in the BMS group died during the 8-month follow-up period (P=0.14). Thirteen patients in the DES group versus 5 patients in the BMS group suffered a cardiac death (P=0.09). In the DES group, 1 patient died during the procedure, and 2 patients died of a malignant arrhythmia. The remaining 10 patients died as a result of cardiogenic shock or progressive heart failure; 4 of these patients died within 1 month after the acute myocardial infarction, and the Clinical Events Committee could not rule out that stent thrombosis occurred eventually in these 4 patients (accordingly, these 4 deaths were classified as probable stent thromboses). In the BMS group, 1 patient died during the procedure, 1 patient died of rupture of the myocardial wall, 1 suffered an arrhythmic death, and 2 developed progressive heart failure. Only 2 patients (1 in each group) died after 1 month. A major adverse cardiac event occurred in 28 patients (8.9%) in the DES group and in 45 patients (14.4%) in the BMS group (P=0.046), a difference that was driven by a marked difference in TLR (5.1% in the DES group and 13.1% in the BMS group; P=0.001). A significant albeit less pronounced difference was observed in clinically driven TLR (Figure 3). The corresponding rate of target vessel revascularization was 6.4% and 16.0%, respectively (P<0.001). Stroke occurred in 1.6% of patients with a DES and 1.0% of patients with a BMS (P=0.73).


Figure 2190689
View larger version (11K):
[in this window]
[in a new window]

 
Figure 2. Major adverse cardiac events (MACE) during 8 months of follow-up. MI indicates myocardial infarction.


Figure 3190689
View larger version (12K):
[in this window]
[in a new window]

 
Figure 3. Kaplan–Meier estimates of survival free of clinically driven TLR among patients who received DES and BMS.

Stent thrombosis occurred in 7 patients (2.0%) in the DES group and in 8 patients (2.6%) in the BMS group (P=0.72). Ten of the stent thromboses were definite, ie, verified angiographically. The 8-month mortality rate of patients not included in the trial was 13% with an overweight of in-hospital deaths.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowConclusions
down arrowAppendix
down arrowReferences
 
Late lumen loss was significantly lower in the DES group compared with the BMS group and slightly less than in several other trials.6,7,16,18 In general, the restenosis level is somewhat smaller in ST-segment–elevation myocardial infarction patients than in patients with chronic stable disease, which is explained to some extent by the larger reference vessel in ST-segment–elevation myocardial infarction but also may be due to differences in the triggering of neointimal growth. In the present study, implantation of 3 different DES during primary percutaneous coronary intervention reduced neointimal proliferation as indicated by a smaller late lumen loss compared with that recorded in BMS during the succeeding 8 months. The rate of binary restenosis in the DES group was of the same magnitude as that reported in the Trial to Assess the Use of the Cypher Stent in Acute Myocardial Infarction Treated With Balloon Angioplasty (TYPHOON), although the difference in diameter stenosis between the 2 groups at follow-up was less pronounced in our patients, probably reflecting the use of different types of stents. We implanted stents that were used contemporarily in our laboratories for patients without ST-segment–elevation myocardial infarction, and contrary to TYPHOON trial, patients with complex lesions such as ostial lesions, lesions in bifurcations, and lesions with a large thrombus burden were not excluded from the DEDICATION trial. The prevalence of diabetes among study patients, together with differences in location of the infarct-related lesions in the left and right coronary arteries, probably explains the differences in vessel size in patients included in our trial and those included in the TYPHOON and the Paclitaxel-Eluting Stent Versus Conventional Stent in Myocardial Infarction With ST-Segment Elevation (PASSION) trial.

Although inclusion criteria were less strict in the DEDICATION trial, as reflected by a higher age of the patients and a higher rate of patients with complex lesions, the late lumen loss and the restenosis rate of patients who received a BMS were of the same magnitude as those reported in the Sirolimus-Eluting Stent Versus Bare-Metal Stent in Acute Myocardial Infarction (SESAMI) and TYPHOON trials.6,18 We also implanted more stents per patient and stented longer segments of the coronary arteries compared with the other trials. In addition, patients with poor left ventricular function (mean left ventricular ejection fraction, 47.5%) were included in the DEDICATION trial.

The acute hemodynamic condition during an acute myocardial infarction, including the possibility of general vasoconstriction, implies a risk of suboptimal choice of stent size and deployment of stents in the infarct-related region.19 However, Spaulding et al6 did not find smaller vessel diameters during the acute procedure compared with those measured during a follow-up angiography 8 months after the primary percutaneous coronary intervention. Operators of the TYPHOON trial were discouraged from oversizing and postdilating the implanted stents with high pressure. On the other hand, the residual stenosis in our patients was of the same magnitude as that reported in the TYPHOON trial but considerably higher than that in the PASSION trial despite a higher deployment pressure. Differences in stent properties and delivery systems, including the polymer of the DES, and different techniques to analyze the angiograms are plausible explanations of these differences. We found a general reduction in the target vessel reference diameter during the 8-month period succeeding the index procedure in patients who had a BMS implanted but not in those who received a DES. Longer-term follow-up of the patients will reveal the possible significance of this finding.

The limited in-stent neointimal proliferation in patients who received a DES resulted in a reduction in the composite end point of major adverse cardiac events from 14.4% to 8.6% (P=0.04), driven mainly by a considerably lower rate of TLR. Tendencies toward higher TLR rates are usually found in patients who have a follow-up angiography performed routinely. However, the reductions in target vessel failure in those who are followed up clinically and those examined invasively seem to be of the same magnitude.6 Like in the TYPHOON trial, TLR in symptom-free patients was allowed in the present study in cases of severe (>70%) restenosis.

The death rate of the DEDICATION patients corresponded to that in the PASSION trial,7 although we observed a tendency toward a higher cardiac death in the DES group. A younger age of patients in the TYPHOON trial compared with that of our patients may account for the lower mortality rate in that trial. The rate of recurrent myocardial infarction and stroke was low and insignificantly different in our patient groups, which is in accordance with previous studies.1,6,7,10 More patients developed cardiogenic shock or progressive heart failure in the DES group (10 versus 2 in the BMS group). On the other hand, a majority of the patients died in hospital, and it is hard to explain any impact of the drug released from the stents on the short-term clinical course.

Using traditional definitions of stent thrombosis, previous reports found a rate of stent thrombosis between 1% and 4% after implantation of BMS in patients with acute myocardial infarction.20–22 Thrombus burden in ST-segment myocardial infarction may predispose to stent thrombosis when DES are routinely used.23 We observed visible thrombus in almost 75% of the DEDICATION patients, although we did not distinguish between large and small thrombus burden. Stent thrombosis occurred in 11 patients in the DEDICATION study using the Academic Research Consortium definitions,15 and definite stent thrombosis was observed in 10 patients (1.6%), 7 of whom had a BMS. This rate of stent thrombosis is lower than that observed in the TYPHOON study,6 although we did not exclude patients with a large thrombus burden. On the other hand, our observation period was somewhat shorter than that of the TYPHOON and PASSION trials. Four of our patients (all in the DES group) died within a month after the myocardial infarction. Because of considerable comorbidity in these patients, our Clinical Events Committee adjudicated these as events not necessarily related to (probable) stent thrombosis in accordance with Cutlip et al.15 We observed only 1 case of possible late stent thrombosis (in the BMS group). However, we will continue monitoring all our patients with regard to this serious side effect to which our patients with ST-segment–elevation myocardial infarctions might, at least theoretically, be predisposed. Accordingly, the importance of a high compliance to dual antiplatelet therapy for at least 1 year has been stressed to the patients.24,25

A drawback of the present study is the lack of blinding of both patients and operators during the primary percutaneous coronary intervention. On the other hand, the angiographic analyses were performed by blinded investigators, and the Clinical Events Committee adjudicated the serious events without knowledge of the treatment sequence. In addition, the study was initiated, conducted, and interpreted completely by the investigators. A considerably higher death rate in the excluded patients during the trial inclusion period reflects the limited comorbidity of those included in the trial. The impact of a higher age, higher frequency of diabetes and prior infarctions, acute occlusion of the left main stem or saphenous vein grafts, and considerably longer time to arrival from onset of symptoms contributed to a worsened prognosis of the excluded patients. It should be emphasized that only 83% of the included patients underwent reangiography and that the study was not powered to detect differences in clinical outcome. The results should be interpreted accordingly.


*    Conclusions
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*Conclusions
down arrowAppendix
down arrowReferences
 
The present randomized study found a significant angiographic benefit and a lower rate of major adverse cardiac events after treatment with DES compared with BMS in a broad range of patients with ST-segment–elevation myocardial infarction. A tendency toward higher cardiac death in the DES group requires further monitoring of the patients.


*    Appendix
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
up arrowConclusions
*Appendix
down arrowReferences
 
Participants of the DEDICATION Trial were as follows. Steering Committee: H. Kelbæk, L. Thuesen, S. Helqvist, J.F. Lassen, P. Clemmensen, C.J. Terkelsen, A. Kaltoft. Data Monitoring Board: L. Kløvgaard. Clinical Events Committee: L. Holmvang, J. Godtfredsen. Coronary Angiography Core Laboratory: B. Andersen, H. Thuesen. Echocardiography Core Laboratory: K.F. Kofoed, L. Køber. Inclusion members: T. Engstrøm, H.E. Bøtker, K. Saunamäki, L.R. Krusell, E. Jørgensen, H.-H.T. Hansen, E.H. Christiansen, J. Ravkilde, H.R. Andersen, J. Kastrup, S.D. Kristensen.


*    Acknowledgments
 
Sources of Funding

This work was supported by unrestricted grants from the Cordis/Johnson & Johnson, Medtronic, Abbott, and Boston Scientific companies.

Disclosures

None.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
up arrowConclusions
up arrowAppendix
*References
 
1. Keeley EC, Boura JA, Grines CL. Primary angioplasty versus intravenous thrombolytic therapy for acute myocardial infarction: a quantitative review of 23 randomised trials. Lancet. 2003; 361: 13–20.[CrossRef][Medline] [Order article via Infotrieve]

2. Andersen HR, Nielsen TT, Rasmussen K, Thuesen L, Kelbæk H, Thayssen P, Abildgaard U, Pedersen F, Madsen JK, Grande P, Villadsen AB, Krusell LR, Haghfelt T, Lomholt P, Husted SE, Vigholt E, Kjaergaard HK, Mortensen LS, for the DANAMI-2 Investigators. A comparison of coronary angioplasty with fibrinolytic therapy in acute myocardial infarction. N Engl J Med. 2003; 349: 733–742.[Abstract/Free Full Text]

3. Boersma E, for the Primary Coronary Angioplasty vs. Thrombolysis Group. Does time matter? A pooled analysis of randomised clinical trials comparing primary percutaneous coronary intervention and in-hospital fibrinolysis in acute myocardial infarction. Eur Heart J. 2006; 27: 779–788.[Abstract/Free Full Text]

4. Silber S, Albertsson P, Aviles FF, Camici PG, Colombo A, Hamm C, Jørgensen E, Marco J, Nordrehaug JE, Ruzyllo W, Urban P, Stone GW, Wijns W. Guidelines for percutaneous coronary interventions: the Task Force for Percutaneous Coronary Intervention of the European Society of Cardiology. Eur Heart J. 2005; 26: 804–847.[Free Full Text]

5. Valgimigli M, Percoco G, Malagutti P, Campo G, Ferrari F, Barbierie D, Cicchitelli G, McFadden EP, Merlini F, Ansani L, Guardigli G, Bettini A, Parrinello G, Boersma E, Ferrari R, for the STRATEGY Investigators. Tirofiban and sirolimus-eluting stent vs abciximab and bare-metal stent for acute myocardial infarction: a randomised trial. JAMA. 2005; 293: 2109–2117.[Abstract/Free Full Text]

6. Spaulding C, Henry P, Teiger E, Beatt K, Bramucci E, Carrié D, Slama MS, Merkely B, Erglis A, Margheri M, Varenne O, Cebrian A, Stoll H-P, Snead DB, Bode C, for the TYPHOON Investigators. Sirolimus-eluting versus uncoated stents in acute myocardial infarction. N Engl J Med. 2006; 355: 1093–1104.[Abstract/Free Full Text]

7. Laarman GJ, Suttorp MJ, Dirksen MT, van Heerebeek L, Kiemeneij F, Slagboom T, van der Wieken L, Tijssen JGP, Rensing BJ, Patterson M. Paclitaxel-eluting versus uncoated stents in primary percutaneous coronary intervention. N Engl J Med. 2006; 355: 1105–1113.[Abstract/Free Full Text]

8. Libby P, Theroux P. Pathophysiology of coronary artery disease. Circulation. 2005; 111: 3481–3488.[Abstract/Free Full Text]

9. Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol. 2006; 48: 193–202.[Abstract/Free Full Text]

10. Stone GW, Webb J, Cox DA, Brodie BR, Qureshi M, Kalynych A, Turco M, Schultheiss HP, Dulas D, Rutherford BD, Antoniucci D, Krucoff MW, Gibbons RJ, Jones D, Lansky AJ, Mehran R. Distal microcirculatory protection during percutaneous coronary intervention in acute ST-segment elevation myocardial infarction. JAMA. 2005; 293: 1063–1072.[Abstract/Free Full Text]

11. Schömig A, Kastrati A. Distal embolic protection in patients with acute myocardial infarction: attractive concept but no evidence of benefit. JAMA. 2005; 293: 1116–1118.[Free Full Text]

12. De Luca G, Suryapranata H, Stone GW, Antoniucci D, Neumann F-J, Chiariello M. Adjunctive mechanical devices to prevent distal embolization in patients undergoing mechanical revascularization for acute myocardial infarction: a meta-analysis of randomized trials. Am Heart J. 2007; 153: 343–353.[CrossRef][Medline] [Order article via Infotrieve]

13. Kelbæk H, Thuesen L, Helqvist S, Kløvgaard L, Jørgensen E, Aljabbari S, Saunamäki K, Krusell LR, Jensen GVH, Bøtker HE, Lassen JF, Andersen HR, Thayssen P, Galløe A, van Weert A, for the SCANDSTENT Investigators. The Stenting Coronary Arteries in Non-Stress/Benestent Disease (SCANDSTENT) trial. J Am Coll Cardiol. 2006; 47: 449–455.[Abstract/Free Full Text]

14. van Weert A, Lesperance J, Reiber JHC. Standardization of central off-line quantitative image analysis: implications from experiences with quantitative coronary angiography. Heart Drug. 2001; 1: 44–51.[CrossRef]

15. Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es G-A, Steg PG, Morel M-a, Mauri L, Vranckx P, McFadden E, Lansky A, Hamon M, Krucoff MW, Serruys PW, for the Academic Research Consortium. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007; 115: 2344–2351.[Abstract/Free Full Text]

16. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE, for the SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003; 349: 1315–1323.[Abstract/Free Full Text]

17. Kelbæk H, Terkelsen CT, Helqvist S, Lassen JF, Clemmensen P, Kløvgaard L, Kaltoft A, Engstrøm T, Bøtker HE, Saunamäki K, Krusell LR, Jørgensen E, Hansen H-HT, Christiansen EH, Ravkilde J, Køber L, Kofoed KF, Thuesen L. Randomized comparison of distal protection versus conventional treatment in primary percutaneous coronary intervention: the drug elution and distal protection in ST-elevation myocardial infarction (DEDICATION) trial. J Am Coll Cardiol. 2008; 51: 889–905.

18. Menichelli M, Parma A, Pucci E, Fiorilli R, De Felice F, Nazzaro M, Giulivi A, Alborino D, Azzellino A, Violini R. Randomized trial of Sirolimus-Eluting Stent Versus Bare-Metal Stent in Acute Myocardial Infarction (SESAMI). J Am Coll Cardiol. 2007; 49: 1924–1930.[Abstract/Free Full Text]

19. Hong MK, Mintz GS, Lee CW, Park DW, Park KM, Lee BK, Kim YH, Song JM, Han KH, Kang DH, Cheong SS, Song JK, Kim JJ, Park SW, Park SJ. Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up. Circulation. 2006; 113: 414–419.[Abstract/Free Full Text]

20. Grines CL, Cox DA, Stone GW, Garcia E, Mattos LA, Giambartolomei A, Brodie BR, Madonna O, Eijgelshoven M, Lansky AJ, O'Neill WW, Morice MC. Coronary angioplasty with or without stent implantation for acute myocardial infarction. N Engl J Med. 1999; 341: 1949–1956.[Abstract/Free Full Text]

21. Maillard L, Hamon M, Khalife K, Steg PG, Beygui F, Guermonprez JL, Spaulding CM, Boulenc JM, Lipiecki J, Lafont A, Brunel P, Grollier G, Koning R, Coste P, Favereaux X, Lancelin B, Van Belle E, Serruys P, Monassier JP, Raynaud P. A comparison of systematic stenting and conventional balloon angioplasty during primary percutaneous transluminal coronary angioplasty for acute myocardial infarction. J Am Coll Cardiol. 2000; 35: 1729–1736.[Abstract/Free Full Text]

22. Stone GW, Grines CL, Cox DA, Garcia E, Tcheng JE, Griffin JJ, Gauigliumi G, Stuckey T, Turco M, Caroll JD, Rutherfor BD, Lansky AJ, for the CADILLAC Investigators. Comparison of angioplasty with stenting, with or without abciximab, in acute myocardial infarction. N Engl J Med. 2002; 346: 957–966.[Abstract/Free Full Text]

23. Sianos G, Papafaklis MI, Daemen J, Vaina S, van Mieghem CA, van Domburg RT, Michalis LK, Serruys PW. Angiographic stent thrombosis after routine use of drug-eluting stents in ST-segment elevation myocardial infarction: the importance of thrombus burden. J Am Coll Cardiol. 2007; 50: 573–583.[Abstract/Free Full Text]

24. Spertus JA, Kettelkamp R, Vance C, Decker C, Jones PG, Rumsfeld JS, Messenger JC, Khanal S, Peterson ED, Bach RG, Krumholz HM, Cohen DJ. Prevalence, predictors, and outcomes of premature discontinuation of thienopyridine therapy after drug-eluting stent placement. Circulation. 2006; 113: 2803–2809.[Abstract/Free Full Text]

25. Eisenstein EL, Anstrom KJ, Kong DF, Shaw LK, Tuttle RH, Mark DB, Kramer JM, Harrington RA, Matchar DB, Kandzari DE, Peterson ED, Schulman KA, Califf RM. Clopidogrel use and long-term clinical outcomes after drug-eluting stent implantation. JAMA. 2007; 297: 159–168.[Abstract/Free Full Text]


 

CLINICAL PERSPECTIVE

Primary percutaneous coronary intervention is the treatment of choice in patients with ST-segment–elevation myocardial infarction and <12 hours duration of pain, but whereas implantation of drug-eluting stents is known to reduce the development of restenosis in most patients, treatment of ST-segment–elevation myocardial infarction is considered an off-label indication of their use. We randomized patients with ST-segment–elevation myocardial infarction to have a drug-eluting or a bare metal stent implanted in their target vessel in connection with primary percutaneous coronary intervention and evaluated their angiographic and clinical outcome. We observed a reduction in the need for repeat revascularization in the drug-eluting stent group, reflecting a significant reduction in neointimal hyperplasia as determined by angiography. We also observed a tendency to an increased rate of cardiac death in the drug-eluting stent group that was not explained by a higher rate of stent thrombosis, a finding that warrants continued clinical follow-up of the patients.


*    Footnotes
 
Clinical trial registration information—URL: http://www.clinical.trials.gov. Unique identifier: NCT 00192868.

*All DEDICATION participants are listed in the Appendix. Back


Related Article:

Clinical Summaries
Circulation 2008 118: 1113-1114. [Extract] [Full Text]



This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
S. R. Dixon, C. L. Grines, and W. W. O'Neill
The year in interventional cardiology.
J. Am. Coll. Cardiol., June 2, 2009; 53(22): 2080 - 2097.
[Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
E. Di Lorenzo, G. De Luca, R. Sauro, A. Varricchio, M. Capasso, T. Lanzillo, F. Manganelli, C. Mariello, F. Siano, M. R. Pagliuca, et al.
The PASEO (PaclitAxel or Sirolimus-Eluting Stent Versus Bare Metal Stent in Primary Angioplasty) Randomized Trial
J. Am. Coll. Cardiol. Intv., June 1, 2009; 2(6): 515 - 523.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. S. Brar, M. B. Leon, G. W. Stone, R. Mehran, J. W. Moses, S. K. Brar, and G. Dangas
Use of drug-eluting stents in acute myocardial infarction: a systematic review and meta-analysis.
J. Am. Coll. Cardiol., May 5, 2009; 53(18): 1677 - 1689.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
118/11/1155    most recent
CIRCULATIONAHA.107.758698v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kelbæk, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kelbæk, H.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Heart Attack
Related Collections
Right arrow Restenosis
Right arrow Catheter-based coronary interventions: stents
Right arrow Acute myocardial infarction
Right arrowRelated Article