| Introduction |
|---|
|
|
|---|
The number of stents currently under investigation is substantial. They are all loaded with drugs that interfere with pathways in the process of inflammation and neointimal proliferation. However, the process of restenosis is a sequence of complex events that has been only partly elucidated over the last 2 decades.9 Locally acting DES provide the opportunity to interfere with the various mechanisms responsible for each step in the restenotic cascade, and a wide variety of different agents are currently available. Although only sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) have received US Food and Drug Administration (FDA) approval to date, multiple alternative devices are attempting to find their way to achieve the same goal, namely a reduction of restenosis and the need for repeat interventions.
| Established and Investigational Drugs |
|---|
|
|
|---|
|
|
A non-Limus familyrelated drug widely studied for its efficacy in coronary stents is paclitaxel. Its effect has been mainly explained by its ability to stabilize microtubules and thereby inhibit cell division in the G0/G1 and G2/M phases.
Sirolimus
The first of the Limus family drugs used on endovascular prosthesis was sirolimus, a natural macrocyclic lactone that is able to inhibit mTOR.10,11 Sirolimus proved to possess potent antiproliferative and immunosuppressive effects. Several successive studies proved the efficacy of the SES (Cypher, Cordis Corp, Warren, NJ), a polymer-coated bare metal Bx Velocity (Cordis Corp) balloon expandable stent, in populations that ranged from highly selected patients with single lesions to unselected all-comers.1218 The Cypher stent was the first DES to receive both Conformité Européenne (CE)-mark and FDA approval in April 2002 and 2003, respectively (Figure 3). Because of the polymer, 75% of the drug is slowly released over the first 10 days. Nevertheless, the antirestenotic properties of the SES proved to persist much longer.19 Because there was no significant change in neointimal thickening between 2 and 4 years in the First in Man (FIM) trial and given the continued clinical superiority of SES after 4 years in a pooled analysis of the 4 pivotal randomized Cypher trials (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions [RAVEL], SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions [SIRIUS], Canadian [C]-SIRIUS and European [E]-SIRIUS), it seems reasonable to rule out a late catch-up in restenosis; at least so far, because both the clinical and angiographic end points continue to slowly accrue over time.14,20
|
Everolimus
A second derivative of the Limus family is everolimus, a sirolimus analog with a single minimal alteration in its molecular structure (position 40), without a chemical modification of the mTOR binding domain21 (Figures 1 and 2
). Of interest is that, when implanted in rabbit iliac arteries, a more rapid endothelialization was observed in the everolimus-eluting stent as compared with sirolimus-, zotarolimus-, or paclitaxel-eluting stents, demonstrated by a complete endothelialization of the struts with exhibition of cd31 (antigen surface marker of good endothelial functionality) in the cells at 14 days (R. Virmani, MD, unpublished data, 2006).
The Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions First (SPIRIT) trial proved the superiority of everolimus embedded in a durable polymer on a cobalt chromium stent as compared with bare metal stents (BMS).22,23 In the recently completed SPIRIT-II trial, the everolimus-eluting XIENCE V stent (Advanced Cardiovascular Systems, an Abbott Vascular Company, Santa Clara, Calif) proved to be superior to the PES for reduction of both late loss and binary restenosis.24 Subsequently, the SPIRIT-III trial has randomized 1002 patients in the US to treatment with either an everolimus XIENCE V stent or a PES. As part of the SPIRIT-III study, additional patients will also be enrolled in 4 registry arms in Japan, 1 each for stents that are 38 mm, 2.25 mm, and 4.0 mm long. Additionally, the SPIRIT-IV and SPIRIT-V studies will provide further clinical data.
Zotarolimus
A third descendant of the Limus family, also with a change on position 40, that is used on coronary stents is zotarolimus (ABT-578, Abbott Pharmaceuticals, Abbott Park, Ill), which likewise contains antiproliferative and antiinflammatory effects, but zotarolimus is suggested to have higher tissue retention compared with the SES (Figures 1, 2
). Of note, recent data on endothelial function after stent placement in porcine coronaries showed a normally functioning endothelium 1 and 3 months after zotarolimus-eluting stent implantation, whereas a dysfunctional endothelium was observed after both Cypher and Taxus implantation.25
In the ENDEAVOR I and II trials, the phosphorylcholine polymer-based cobalt-alloy Driver coronary stent (Medtronic Vascular, Santa Rosa, Calif), loaded with zotarolimus, proved to be superior to BMS in both angiographic and clinical end points.26,27 Recently presented 2- and 3-year follow-up data of the ENDEAVOR I and II trials proved sustained superiority in the reduction of target lesion revascularization (TLR) with remarkably low rates of total stent thrombosis (0.3%) and no cases of stent thrombosis after 30 days. The ENDEAVOR III trial was a prospective randomized comparison of the Endeavor zotarolimus-eluting stent and the SES (n=436). At 8 months, the Endeavor stent failed to meet its noninferiority end point in terms of late lumen loss. Of note, the rates of death, myocardial infarction, and target vessel revascularization were equal in both groups.28 A possible explanation for the lack of noninferiority of the Endeavor stent might be the rate of elution. The Cypher stent elutes 75% of its drug within the first 10 days; in the Endeavor stent this took only 2 days.
Another zotarolimus-eluting device is the Zomaxx TriMaxx stent (Abbott Pharmaceuticals, Abbott Park, Ill.), which has a trilayer pharmacoat that consists of a phosphorylcholine basecoat and topcoat wrapped around a zotarolimus layer with elution rates comparable to the Cypher stent. The platform used was a stainless steel/tantalum/stainless steel triplex stent. Although the 4-month results of the Zomaxx-IVUS trial (n=40), which showed a late loss of 0.20 mm, were promising, its manufacturer Abbott recently announced it would discontinue the Zomaxx program after the disappointing results of the Zomaxx-I trial. At 9 months, the Zomaxx stent was associated with a significantly higher late loss and binary restenosis rate compared with the Taxus stent.29
Biolimus
Biolimus A9 is a highly lipophilic sirolimus analog that inhibits T cell and smooth muscle cell proliferation (Figures 1 and 2
). The Stent Eluting A9 Biolimus Trial in Humans (STEALTH) trial was the FIM study to assess the safety and efficacy of the poly-lactic acid bioabsorbable-polymer-coated Biolimus A9eluting BioMatrix stent (Biosensors International, Singapore). A stainless steel S-stent was the basis for a biodegradable polymer coating that released its drug gradually over 6 to 9 months. The STEALTH-I trial randomized 120 (1:2) patients to treatment with a control bare metal S-stent or a Biolimus A9eluting stent. Although the 12-month clinical event rates were similar between both groups, treatment with the Biolimus A9 stent was associated with a 57% lower rate of binary restenosis and 65% lower rate of late lumen loss compared with the BMS group at 6 months.30 The recently presented 9-month results of the Nobori-I trial, which randomized (2:1) patients to either a PES (n=35) or the Biolimus-eluting stent (n=85), showed significantly less late lumen loss in the Biolimus arm as compared with the Taxus arm.31
Pimecrolimus
Although a part of the Limus family, pimecrolimus does not block mTOR and inhibits to a much lesser degree the endothelial cell proliferation (Figures 1 and 2
).32 The active pharmaceutical ingredient of pimecrolimus is Elidel, an FDA-approved drug developed by Novartis Pharmaceuticals Corp, East Hanover, NJ) for the treatment of atopic dermatitis. The FIM study to evaluate the safety and efficacy of a pimecrolimus-eluting stent is currently ongoing.33
Tacrolimus
Tacrolimus (FK506) is a water-insoluble macrolide immunosuppressant produced by streptomyces tsukubaensis (Figures 1 and 2
). Tacrolimus is also known as Prograf, a drug widely used to prevent allograft rejection after organ transplantation. Tacrolimus is a noncytotoxic T cell inhibitor, which holds cells in the G0 or resting phase. In this situation, cells are able to function but unable to replicate. The end result of tacrolimus is a reduction in activation of cytokine genes. In contrast to sirolimus, tacrolimus demonstrates far more potent inhibition of smooth muscle cells rather than endothelial cells.4,34
The multicenter European Direct Stenting of De Novo Coronary Artery Stenosis With Tacrolimus-Eluting Versus Carbon-Coated Carbostents (JUPITER)II trial (n=332) was conducted to compare the safety and effectiveness of direct stenting with a Janus tacrolimus-eluting stent (Sorin Biomedica Cardio, Saluggia, Italy) versus the mechanical platform with no drug-eluting capability from which the Janus stent (Tecnic CCS coronary carbostents) was derived. In the Janus tacrolimus-eluting stent, the drug is embedded in reservoirs carved on the outer stent surface to release the drug only toward the vessel wall and possesses an integral thromboresistant carbofilm coating on the whole stent surface. Remarkable was that at 1 year no cases of stent thrombosis were reported in the polymer-free tacrolimus-eluting stent arm. However, the 6-month in-stent late lumen loss of 0.65 mm for the Janus was equal to the Tecnic carbostent; therefore the study failed to meet its primary end point.35 The currently ongoing 3-arm Inova trial is evaluating the efficacy of a Janus Carbofilmcoated SRT stent platform with different formulations of tacrolimus: (1) pure tacrolimus (3.3 µg/mm2); (2) tacrolimus with 20% ascorbyl palmitate (2.3 µg/mm2); (3) tacrolimus with 20% PVP Kollidon 17 (2.3 µg/mm2). Along these lines, the Japanese company Kaneka is evaluating the efficacy of a tacrolimus when applied on a cobalt chromium platform with a poly-DL-lactide-co-glycolide biodegradable polymer.
Paclitaxel
Although not a member of the Limus family, the PES (Taxus, Boston Scientific, Natick, Mass) was the second DES to receive FDA approval, 1 year after the SES. Paclitaxel was first found by The National Cancer Institute in a search for naturally occurring agents with strong antiproliferative qualities. Paclitaxel stabilizes microtubules and thereby inhibits cell division in the G0/G1 and G2/M phases (Figure 1). The randomized TAXUS-I trial (2003) was designed as a FIM phase I feasibility study and proved that a polymer-coated PES was superior to BMS at 6 and 12 months of follow-up.36 Thereafter, the TAXUS family trials expanded with the II, IV, V, and VI trials and confirmed the superiority of PES as compared with BMS in more complex patients and lesions.3639 Recently, the TAXUS-V-ISR (in-stent restenosis) trial compared the efficacy of a slow-release polymer-based PES with brachytherapy for in-stent restenotic lesions. At 9 months, the use of PES was associated with lower rates of clinical and angiographic restenosis and an improved event-free survival.40 The TAXUS clinical trial program, which assessed the TAXUS Express stent system from single to complex lesions, was followed by the TAXUS ATLAS and Olympia programs, which transferred the established polymer drug combination to a new stent platform, the Liberté stent.41,42
Another new device coated with paclitaxel is the Asian Infinnium (Sahajanand Medical Technologies, Gujarat, India) stent. The stent has a biodegradable hemocompatible polymer coating and lower strut thickness (0.084 mm compared with 0.14 mm for Cypher) designed to reduce vessel trauma. The coating consists of slow, medium, and fast release polymer layers. The multicenter open-label registry Safety and Efficacy of Infinnium: A Paclitaxel-Eluting Stent (SIMPLE-I) trial (n=282) was the first to test the efficacy of this new device. The SIMPLE-I trial was followed by the multicenter, single-arm, prospective SIMPLE-II trial (n=103) to further investigate the safety and the efficacy of the Infinnium stent.43 With little late loss at 6 months (0.38 mm) and a binary restenosis rate of 7.3%, the device was the first indigenously designed and evaluated "low-cost" DES from Asia to receive CE mark approval.
| New Coatings |
|---|
|
|
|---|
To reduce the inflammatory reaction, which is partially caused by the polymer, Medtronic recently developed a novel co-polymer, the "Endeavor Resolute", for extended release of zotarolimus in a next-generation DES. The new BioLinx polymer system contains a C10 polymer, which is lipophilic/hydrophobic and stimulates a controlled drug release, a C19 polymer, which is primarily hydrophilic and thus more biocompatible and helpful in drug elution, and finally polyvinyl pyrrolidone, which is hydrophilic, increases the initial drug burst, and enhances the elution rate. Porcine coronary implants (n=25) showed no difference in inflammatory response after implantation of the Endeavor Resolute or a control BMS and a 100% re-endothelialization. Four-month follow-up in the first 30 patients revealed an in-stent late loss of 0.12 mm, and no target vessel revascularization or stent thrombosis were observed.52
In a search for more biocompatible coatings, hydroxyapatite was found to be a valuable alternative as a polymer surrogate. Hydroxyapatite is a well-known and excellent bioceramic that closely resembles biological apatite (bone); it is biocompatible, bioactive, and bioresorbable, and it forms the basis of a polymer that is only 200 nm thick.53 Furthermore, its porous structure makes it an ideal drug carrier. Likewise, a new spongious nanocarbon coating constructed of porous, glassy, pyrolytic carbon, which guarantees extraordinary elasticity, was recently developed. Lastly, the Intracoronary Stenting and Angiographic RestenosisTest Equivalence Between 2 Drug-Eluting Stents (ISAR-TEST) study recently showed that a polymer-free, microporous, sirolimus-coated Yukon stent (Translumina, The Drug-Eluting System Company, Hechinger, Germany) was not inferior to a polymer-based PES in the reduction of restenosis.54
Another alternative for the polymer is a heparin coating. Heparin-coated stents proved to be superior to both balloon angioplasty and BMS. In 1996, the Belgium Netherlands Stent II (BENESTENT II) randomized trial proved the superiority of heparin-coated stents as compared with balloon angioplasty. A more recent registry even proved a significant reduction in stent thrombosis in the heparin-coated stent as compared with a standard BMS.55 Sahajanand Medical Technologies Pvt. Ltd. (Saiyedpura, Surat, India), recently designed a dual-layer heparin-SES, which combines the antiproliferative action of sirolimus with the excellent biocompatibility and hemocompatibility of the heparin coating. Both drugs elute almost simultaneously, whereas heparin will give effect for almost 50 days and sirolimus for 60 days.
A completely new concept is heparin-coupled with poly-L-lactic acid to create a so-called absorbable "heparinized" polymer, which in turn can serve as a drug reservoir.
Indeed, the most commonly studied biodegradable polymers are derived from lactic and glycolic acid. Biodegradation is achieved by hydrolytically unstable linkages (esters) in the backbone of the polymer, which results in surface erosion. The rate of erosion or biodegradation can be altered by the molecular weight of the polymer and the number of unstable linkages. Furthermore, the drug-release profile can be adjusted by alteration of the biodegradation profile of the polymer.
| New Platforms |
|---|
|
|
|---|
The 30-day results of the FIM ABSORB trial (n=30) are worth mentioning. The BVS stent (Figure 4) (Bioabsorbable Vascular Solutions, Guidant Corp, Indianapolis, Ind), the worlds first fully absorbable DES, which consists of a bioabsorbable polylactic acid polymer that contains everolimus (98 µg/cm2 of surface area) and a bioabsorbable BVS polylactic acid stent platform, proved to be associated with a 100% procedural success rate and a major adverse cardiac event rate of 0%. Furthermore, the stent recoil of 6.85% was comparable to the 4.27% seen with the XIENCE V metal stent.5961
|
REVA Medical, Inc. (San Diego, Calif) is presently investigating a fully absorbable polymer stent with a "slide & lock" design; sliding parts with monodirectional lockouts that are hypothesized to result in a nearly negligible stent recoil (Figure 5). The stent consists of a radiopaque tyrosine-derived polycarbonate backbone. The composition of the polymer, comprised of 3 basic components, allows the resorption time to be varied by a change in the ratio of these components. Both a bare and a paclitaxel-eluting version, in which the polymer is mixed with the drug, will become available. The Randomized Endovascular Study of the REVA Bioresorbable Stent (RESORB) clinical trial has been recently designed to assess the safety of this new platform.
|
Another alternative for the metallic backbone of the stent was found in magnesium. Magnesium, with antithrombotic, antiarrhythmic, and antiproliferative properties, is one of the first natural body components to be used as a basis for a bioabsorbable stent. Several experimental studies to evaluate the efficacy of a magnesium alloy stent degradable by biocorrosion have been performed. Heublein et al described the use of a coronary stent prototype that consisted of the noncommercial magnesium-based alloy AE21 (contains 2% aluminum and 1% rare earth metals) with an expected 50% loss of mass within 6 months in 11 domestic pigs (Figure 6). Quantitative angiography at follow-up showed a significant 40% loss of perfused lumen between 10 and 35 days caused by the loss of mechanical integrity of the stent.62 One year later, the use of a bioabsorbable magnesium alloybased stent with a controlled corrosion in 20 patients with critical limb ischemia was described. At 9 months, a 90% vessel patency was observed.63 As a result of the successful FIM trial (n=5) by Erbel and colleagues, the enrollment in the larger worldwide PROGRESS-AMS study has been recently completed.64 The 4-month results showed a late loss of 1.08± 0.49 and an ischemia-driven TLR rate of 23.8%, which was comparable to those reported with the use of BMS.
|
| New Concepts |
|---|
|
|
|---|
35%) and smooth muscle cell (
60%) proliferation.6568 Although the Study of Antirestenosis With the BiodivYsio Dexamethasone-Eluting Stent (STRIDE) trial, the FIM pilot trial that evaluated the safety and efficacy of a dexamethasone-eluting stent (BiodivYsio Matrix LO stent, Biocompatibles, Ltd., Farnham, UK) demonstrated an acceptable binary restenosis rate of 13.3%,69 the preliminary 6-month results of the larger-scale Drug-Eluting Stents for In-Stent Restenosis (DESIRE) trial showed a clinically driven target vessel recascularization rate of 9.5%, which was
50% higher than the target vessel recascularization rates in the TAXUS-IV and SIRIUS trials.70 The final results were never published, and it is to be expected whether the simultaneous inhibition of smooth muscle cell proliferation and endothelial inflammation by zotarolimus and dexamethasone in the Zodiac program will turn out to be successful. Promising results are also expected from the Randomized, Multicenter Study of the Pimecrolimus-Eluting (Corio) and Pimecrolimus/PaclitaxelEluting Coronary Stent System (SymBio) in Patients With De Novo Lesions of the Native Coronary Arteries (GENESIS) trial, which will compare a dual paclitaxel/pimecrolimus-eluting stent with a stent that elutes only pimecrolimus. Additionally, a dual sirolimus/genistein-eluting stent is currently under investigation (Figure 7). Genistein is a potential isoflavone, which possesses dose-dependent antiplatelet and antiproliferative properties and inhibits collagen-induced platelet aggregation responsible for primary thrombosis. The stent consists of 5 layers that contain an alternating blend of sirolimus and genistein and a drug-free top layer. The unique biodegradable heparinized polymer blend includes poly-L-lactide, poly-DL-lactide-co-glycolide and polyvinyl pyrrolidone. A complex elution pattern aims to provide both smooth muscle cell proliferation by sirolimus and short- and long-term thrombus formation by genistein.
|
| The Prohealing Approach |
|---|
|
|
|---|
Following the dual-elution trend, recent developments have been made on an EPC-DES combination. A concept of a stent with a biodegradable, abluminally focused drug on a Genous-coated platform with an additional drug component integrated throughout the polymer backbone. The stent should be able to enhance drug delivery at the abluminal site, to inhibit neointimal proliferation, and to simultaneously possess CD34 endothelial cell capture activity at the endoluminal site to enhance reendothelialization.
| New Techniques of Elution |
|---|
|
|
|---|
The Paclitaxel in Stent Controlled Eluting Study (PISCES) study was the FIM study to evaluate the safety and potential efficacy of a 316L stainless steel Conor stent system with an erodable polymer with complete elution of low doses of paclitaxel. The study included 6 groups distinguished by different paclitaxel-doses with fast or slow and unidirectional or bidirectional release kinetics. At 30 days, the lowest in-stent late loss (0.38 mm and 0.30 mm) and volume obstruction (8% and 5%) were observed in the 10-µg and 30-µg doses groups, respectively, both with unidirectional release.75,76 The PISCES study was followed by the Study of Controlled Elution of Paclitaxel for the Elimination of Restenosis (SCEPTER) trial, a safety and effectiveness study intended to justify market clearance in the European Community and incorporate 2 arms of 130 patients.77
The Conor Cobalt Chromium Stent With Antiproliferative for Restenosis (COSTAR)-I trial evaluated the use of an equally effective, more flexible, and more deliverable cobalt chromium COSTAR paclitaxel-eluting coronary stent system. The stent uses a poly-lactic-co-glycolic acid bioabsorbable polymer, limited to the small wells embedded in the stent where the drug is loaded, which thereby leaves the actual stent surface free of polymer.78 The small-scale dose-finding COSTAR-I trial (n=87) was directly followed by the European Cobalt Chromium Stent With Antiproliferative for Restenosis (EuroSTAR) trial and the COSTAR-II trial. The EUROSTAR trial showed that the Costar stent system was highly deliverable and radiopaque, and it permitted high rates of acute success and direct stenting. One-year clinical follow-up data showed a 2.8% and 3.4% incidence of TLR in the 10-µg and 30-µg groups, respectively, associated with an in-stent late loss of 0.25 mm and 0.36 mm.79 On the basis of these results, the cobalt chromium COSTAR paclitaxel-eluting coronary stent recently received CE mark approval.
Furthermore, the deliverability of the stent has proven to be of great importance. With the growing complexity of the lesions treated percutaneously, there exists a need for devices with better deliverability and higher flexibility. For that reason, both the Taxus Liberté (Boston Scientific) and Cypher Select (Cordis) were developed.
To improve the efficacy of stenting of specific lesions like bifurcations, the multicenter Axxess Plus Biolimus Stent in LMCA Bifurcations Trial (AXXENT) registry (n=33), was conducted to evaluate the safety and efficacy of the DEVAXAXXESS bifurcation stent (Devax, Inc., Irvine, Calif) for use in the left main coronary artery. Procedural success rates have been shown to be high, and with a 30-day major adverse cardiac event rate of 6.1%, the early results looked encouraging.80 Recently the DIVERGE trial has been conducted to further assess the efficacy of this specific bifurcation device. Comparable dedicated bifurcation devices are the Multilink Frontier (Abbott),81 which was designed to preserve side-branch access; the Invatec system (Invatec srl, Roncadelle, Italy) with axial and rotational self-positioning properties; the Nile CroCo (Minvasys, Gennevilliers, France), which allows instant poststent "kissing balloon" dilatation; the Petal (Boston Scientific) with a side aperture and deployable struts; the Sideguard (Cappella, Inc, Auburndale, Mass), a Nitinol self-expanding device on a single-catheter delivery system; and the Tryton stent (Tryton Medical, Inc, Newton, Mass).
A promising new concept is the Xtent modular system for long lesions, multiple lesions, and multivessel disease (Figure 8). The Biolimus A9 polylactic acid bioabsorbable polymer-coated stent (Biosensors International) has a modular design and consists of multiple 6-mm cobalt chromium stent segments that are interdigitated, which allows for in situ customization of stent length. The delivery system consists of a balloon that can be shortened and reused during the procedure, which may eliminate the need to use a separate postdeployment balloon and may result in significant device cost savings, reduced catheter exchanges, and shorter procedure times. The device is currently under investigation in the CUSTOM-II trial, which aims to extend the promising results of the CUSTOM-I registry.
|
Finally, an ultralow-profile, self-expandable, thin strut stent mounted on a guide wire (CardioMind, Sunnyvale, Calif) is in development for specific use in small vessels.
| Current Clinical Results |
|---|
|
|
|---|
Currently, a variety of trials that compare the Taxus and CYPHER stents to several newcomers are in progress. In the Prospective, Multicenter, Randomized Trial of Zotarolimus- and Paclitaxel-Eluting Stents in Patients With Coronary Artery Disease (ZOMAXX-I) (n=396), which compared the zotarolimus-eluting Zomaxx stent to a PES, the Zomaxx stent was shown to be associated with a significantly higher late loss at 9 months and thereby failed to meet its primary end point.29 The CObalt chromium STent with Anti-proliferative for Restenosis (COSTAR)-II trial, which used the CONOR platform, is an ongoing, prospective, randomized controlled trial that will include
2000 patients at 85 international sites that compare the use of the COSTAR stent to a TAXUS stent.78,96,97 Medtronics Patient-Related OuTcomes with Endeavor versus Cypher stenting Trial (PROTECT) is currently enrolling 8000 patients to compare the safety and efficacy of the Endeavor zotarolimus-eluting stent to the Cypher stent, with stent thrombosis as one of its primary end points at 3 years.
Also currently ongoing are 2 prospective, randomized, multicenter trials that compare the Biolimus A9eluting Biomatrix (Biolimus-eluting stent) with a Cypher SES (Limus Eluted From a Durable versus Erodable Stent Coating (LEADERS) trial; n=1700) and to a Taxus PES (Nobori-I study; n=360). The recently presented 9-month results of the Nobori-I showed significantly less late lumen loss in the Biolimus arm as compared with the Taxus arm.31 Finally, the large-scale SPIRIT III, which was designed for further evaluation of the efficacy of the XIENCE V everolimus-eluting stent, has finished enrollment of its randomized arm.
| Conclusions |
|---|
|
|
|---|
Currently, various innovative DES types are emerging and will become available in the coming years with the intention to avoid the current pitfalls. Abolition of neointimal hyperplasia is no longer the ultimate goal and has been replaced by the development of more biocompatible and bioabsorbable stents that facilitate adequate endothelialization.
Recently, the FDA acknowledged a cause of concern for late adverse events after stent implantation and called for long-term monitoring of safety outcome. It is hoped that the testing of possible remedies to the current deficiencies of the first-generation DES will not be paradoxically hindered by more stringent regulatory measures as a penalty for the late recognition of their inherent limitations.
| Acknowledgments |
|---|
None.
| Footnotes |
|---|
| References |
|---|
|
|
|---|
2. McFadden EP, Stabile E, Regar E, Cheneau E, Ong AT, Kinnaird T, Suddath WO, Weissman NJ, Torguson R, Kent KM, Pichard AD, Satler LF, Waksman R, Serruys PW. Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy. Lancet. 2004; 364: 15191521.[CrossRef][Medline] [Order article via Infotrieve]
3. Nebeker JR, Virmani R, Bennett CL, Hoffman JM, Samore MH, Alvarez J, Davidson CJ, McKoy JM, Raisch DW, Whisenant BK, Yarnold PR, Belknap SM, West DP, Gage JE, Morse RE, Gligoric G, Davidson L, Feldman MD. Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project. J Am Coll Cardiol. 2006; 47: 175181.
4. Hofma SH, van der Giessen WJ, van Dalen BM, Lemos PA, McFadden EP, Sianos G, Ligthart JM, van Essen D, de Feyter PJ, Serruys PW. Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation. Eur Heart J. 2006; 27: 166170.
5. Babinska A, Markell MS, Salifu MO, Akoad M, Ehrlich YH, Kornecki E. Enhancement of human platelet aggregation and secretion induced by rapamycin. Nephrol Dial Transplant. 1998; 13: 31533159.
6. Sianos G, Hofma S, Ligthart JM, Saia F, Hoye A, Lemos PA, Serruys PW. Stent fracture and restenosis in the drug-eluting stent era. Catheter Cardiovasc Interv. 2004; 61: 111116.[CrossRef][Medline] [Order article via Infotrieve]
7. Scheller B, Grandt A, Wnendt S, Lorenz G, Bohm M, Nickenig G. Comparative study of tacrolimus and paclitaxel stent coating in the porcine coronary model. Z Kardiol. 2005; 94: 445452.[CrossRef][Medline] [Order article via Infotrieve]
8. Virmani R. Not so fast: animals dont lie: your clinical follow-up isnt long enough! Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 1721, 2005; Washington, DC.
9. Virmani R, Farb A. Pathology of in-stent restenosis. Curr Opin Lipidol. 1999; 10: 499506.[CrossRef][Medline] [Order article via Infotrieve]
10. Marx SO, Marks AR. Bench to bedside: the development of rapamycin and its application to stent restenosis. Circulation. 2001; 104: 852855.
11. Gingras AC, Raught B, Sonenberg N. mTOR signaling to translation. Curr Top Microbiol Immunol. 2004; 279: 169197.[Medline] [Order article via Infotrieve]
12. Rensing BJ, Vos J, Smits PC, Foley DP, van den Brand MJ, van der Giessen WJ, de Feijter PJ, Serruys PW. Coronary restenosis elimination with a sirolimus eluting stent: first European human experience with 6-month angiographic and intravascular ultrasonic follow-up. Eur Heart J. 2001; 22: 21252130.
13. Sousa JE, Costa MA, Abizaid AC, Rensing BJ, Abizaid AS, Tanajura LF, Kozuma K, Van Langenhove G, Sousa AG, Falotico R, Jaeger J, Popma JJ, Serruys PW. Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up. Circulation. 2001; 104: 20072011.
14. Aoki J, Abizaid AC, Serruys PW, Ong AT, Boersma E, Sousa JE, Bruining N. Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients. J Am Coll Cardiol. 2005; 46: 16701676.
15. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, OShaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003; 349: 13151323.
16. Schofer J, Schluter M, Gershlick AH, Wijns W, Garcia E, Schampaert E, Breithardt G. Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS). Lancet. 2003; 362: 10931099.[CrossRef][Medline] [Order article via Infotrieve]
17. Schampaert E, Cohen EA, Schluter M, Reeves F, Traboulsi M, Title LM, Kuntz RE, Popma JJ. The Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries (C-SIRIUS). J Am Coll Cardiol. 2004; 43: 11101115.
18. Lemos PA, Serruys PW, van Domburg RT, Saia F, Arampatzis CA, Hoye A, Degertekin M, Tanabe K, Daemen J, Liu TK, McFadden E, Sianos G, Hofma SH, Smits PC, van der Giessen WJ, de Feyter PJ. Unrestricted utilization of sirolimus-eluting stents compared with conventional bare stent implantation in the "real world": the Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) registry. Circulation. 2004; 109: 190195.
19. Daemen J, Ong A, Stefanini G, Tsuchida K, Spindler H, Sianos G, De Jaegere P, Van Domburg R, Serruys P. Three-year clinical follow-up of the unrestricted use of the sirolimus-eluting stent compared to the use of a standard bare metal stent as part of the Rapamycin-Eluting-Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) registry. Am J Cardiol. 2006; 98: 895901.[CrossRef][Medline] [Order article via Infotrieve]
20. Leon BF, Moses J, Holmes DR, Kereiakes D, Cutlip D, Cohen DJ, Kuntz R. Long-term benefit of cypher sirolimus eluting coronary stents: four-year follow-up of the SIRIUS study. Paper presented at the American College of Cardiology Conference; March 1114, 2006; Atlanta, Ga.
21. Schuler W, Sedrani R, Cottens S, Haberlin B, Schulz M, Schuurman HJ, Zenke G, Zerwes HG, Schreier MH. SDZ RAD, a new rapamycin derivative: pharmacological properties in vitro and in vivo. Transplantation. 1997; 64: 3642.[CrossRef][Medline] [Order article via Infotrieve]
22. Serruys P, AT O, Piek JJ, Neumann FJ, Van der Giessen W, Wiemer M, Zeiher AM, Grube E, Haase J, Thuesen L, Hamm CW, Otto-Terlouw P. A randomized comparison of a durable polymer Everolimus-eluting stent with a bare metal coronary stent: the SPIRIT first trial. Euro Intervention. 2005; 1: 5865.
23. Tsuchida K, Piek JJ, Neumann FJ, Van der Giessen W, Wiemer M, Zeiher AM, Grube E, Haase J, Thuesen L, Hamm C, Veldhof S, Dorange C, Serruys PW. One-year results of a durable polymer everolimus-eluting stent in de novo coronary narrowings (The SPIRIT FIRST Trial). Euro Intervention. 2005; 1: 266272.
24. Serruys PW, Ruygrok PJN, Piek JJ, Seth A, Schofer J, Richardt G, Wiemer M, Carrie D, Thuesen L, Boone E, Miguel-Herbert K, Daemen J. A randomized comparison of an everolimus eluting coronary stent with a paclitaxel eluting coronary stent: the SPIRIT II trial Euro Intervention. 2006; 2: 286294.
25. Haraguchi G, Pruitt S, Brodeur A, Collingwood R, Carter AJ, Melder RJ, Wilcox JN. Increased expression of eNOS by Endeavor zotarolimus-eluting stents compared to other DES in porcine coronary artery implants. Am J Cardiol. 2006; 98 (Suppl): 3233.[CrossRef]
26. Meredith IT, Ormiston J, Whitbourn R, Kay P, Muller D, Bonan R, Popma J, Cutlip D, Fitzgerald P, Prpic R, Kuntz R. First-in-human study of the Endeavor ABT-578-eluting phosphorylcholine-encapsulated stent system in de novo native coronary artery lesions: Endeavor I Trial. Euro Intervention. 2005; 1: 157164.
27. Fajadet J, Wijns W, Laarman GJ, Kuck KH, Ormiston J, Munzel T, Popma JJ, Fitzgerald PJ, Bonan R, Kuntz RE. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial. Circulation. 2006; 114: 798806.
28. Kandzari DE, Leon MB, Popma JJ, Fitzgerald PJ, OShaughnessy C, Ball MW, Turco M, Applegate RJ, Gurbel PA, Midei MG, Badre SS, Mauri L, Thompson KP, LeNarz LA, Kuntz RE. Comparison of zotarolimus-eluting and sirolimus-eluting stents in patients with native coronary artery disease: a randomized controlled trial. J Am Coll Cardiol. 2006; 48: 24402447.
29. Chevalier B. A randomized, controlled trial to evaluate the safety and efficacy of the ZoMaxx Drug-Eluting Coronary Stent System compared to the TAXUS Express2 Paclitaxel-Eluting Coronary Stent System in de novo coronary artery lesions. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 2227, 2006; Washington, DC.
30. Grube E, Hauptmann K, Buellesfeld L, Lim V, Abizaid A. Six-month results of a randomized study to evaluate safety and efficacy of a biolimus A9 eluting stent with a biodegradable polymer coating. Euro Intervention. 2005; 1: 5357.
31. Chevalier B. NOBORI 1: part 1: a prospective, randomized trial of Biolimus A9 and paclitaxel-eluting stents: 9-month clinical and angiographic follow-up. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 2227, 2006; Washington, DC.
32. Zollinger M, Waldmeier F, Hartmann S, Zenke G, Zimmerlin AG, Glaenzel U, Baldeck JP, Schweitzer A, Berthier S, Moenius T, Grassberger MA. Pimecrolimus: absorption, distribution, metabolism, and excretion in healthy volunteers after a single oral dose and supplementary investigations in vitro. Drug Metab Dispos. 2006; 34: 765774.
33. Abizaid A. Avantec pimecrolimus eluting stent. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 1721, 2005; Washington, DC.
34. Steffel J, Latini RA, Akhmedov A, Zimmermann D, Zimmerling P, Luscher TF, Tanner FC. Rapamycin, but not FK-506, increases endothelial tissue factor expression: implications for drug-eluting stent design. Circulation. 2005; 112: 20022011.
35. Morice MC, Wijns W, DiMario C, Macaya C, Verheye S, Carrié D, de Winter R, Aengevaeren V, Dubois C, Hoffmann S, Pachinger O. Direct stenting of de novo coronary stenoses with tacrolimus-eluting versus carbon-coated carbostents: the randomized JUPITER II trial. Euro Intervention. 2006; 2: 4552.
36. Colombo A, Drzewiecki J, Banning A, Grube E, Hauptmann K, Silber S, Dudek D, Fort S, Schiele F, Zmudka K, Guagliumi G, Russell ME. Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation. 2003; 108: 788794.
37. Stone GW, Ellis SG, Cox DA, Hermiller J, OShaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med. 2004; 350: 221231.
38. Stone GW, Ellis SG, Cannon L, Greenberg J, Mann JT, Spriggs D, DeMaio S, OShaughnessy C, Hall P, Powers ER, Goli V, Kereiakes D, Popma J, Russell ME. Outcomes of the polymer-based paclitaxel-eluting TAXUS stent in complex lesions: principal clinical and angiographic results from the TAXUS-V Pivotal Randomized Trial. Paper presented at: Annual Scientific Session of the American College of Cardiology; March 69, 2005; Orlando Fla.
39. Stone GW, Gruberg L. TAXUS VI: Two-year results from the pivotal prospective randomized trial of the slow-release polymer-based paclitaxel-eluting stent. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; September 27October 1, 2004; Washington DC.
40. Stone GW, Ellis SG, Cannon L, Mann JT, Greenberg JD, Spriggs D, OShaughnessy CD, DeMaio S, Hall P, Popma JJ, Koglin J, Russell ME. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: a randomized controlled trial. JAMA. 2005; 294: 12151223.
41. Turco M, Ormiston J. TAXUS ATLAS 9-month results: evaluation of TAXUS Liberté versus TAXUS Express. Paper presented at: Congress of the EuroPCR; May 1619, 2006; Paris, France.
42. Thomas M. TAXUS Liberté in everyday practice: the TAXUS OLYMPIA post-approval registry. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 2227, 2006; Washington, DC.
43. Vranckx P, Serruys PW, Gambhir S, Sousa E, Abizaid A, Lemos P, E R, Dani SI, Dalal JJ, Mehan V, Dhar A, Dutta A, Reddy KN, Chand R, Ray A, Symons J. Biodegradable-polymer-based, paclitaxel-eluting Infinnium stent: 9-month clinical and angiographic follow-up results from the SIMPLE II Prospective Multi-Centre Study. Euro Intervention. 2006; 2: 310317.
44. Kastrati A, Schomig A, Dirschinger J, Mehilli J, von Welser N, Pache J, Schuhlen H, Schilling T, Schmitt C, Neumann FJ. Increased risk of restenosis after placement of gold-coated stents: results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease. Circulation. 2000; 101: 24782483.
45. Iofina E, Langenberg R, Blindt R, Kuhl H, Kelm M, Hoffmann R. Polymer-based paclitaxel-eluting stents are superior to nonpolymer-based paclitaxel-eluting stents in the treatment of de novo coronary lesions. Am J Cardiol. 2006; 98: 10221027.[CrossRef][Medline] [Order article via Infotrieve]
46. Gershlick A, De Scheerder I, Chevalier B, Stephens-Lloyd A, Camenzind E, Vrints C, Reifart N, Missault L, Goy JJ, Brinker JA, Raizner AE, Urban P, Heldman AW. Inhibition of restenosis with a paclitaxel-eluting, polymer-free coronary stent: the European Evaluation of Paclitaxel Eluting Stent (ELUTES) trial. Circulation. 2004; 109: 487493.
47. Park SJ, Shim WH, Ho DS, Raizner AE, Park SW, Hong MK, Lee CW, Choi D, Jang Y, Lam R, Weissman NJ, Mintz GS. A paclitaxel-eluting stent for the prevention of coronary restenosis. N Engl J Med. 2003; 348: 15371545.
48. Lansky AJ, Costa RA, Mintz GS, Tsuchiya Y, Midei M, Cox DA, OShaughnessy C, Applegate RA, Cannon LA, Mooney M, Farah A, Tannenbaum MA, Yakubov S, Kereiakes DJ, Wong SC, Kaplan B, Cristea E, Stone GW, Leon MB, Knopf WD, ONeill WW. Non-polymer-based paclitaxel-coated coronary stents for the treatment of patients with de novo coronary lesions: angiographic follow-up of the DELIVER clinical trial. Circulation. 2004; 109: 19481954.
49. van der Giessen WJ, Lincoff AM, Schwartz RS, van Beusekom HM, Serruys PW, Holmes Jr DR, Ellis SG, Topol EJ. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation. 1996; 94: 16901697.
50. Sousa JE, Costa MA, Farb A, Abizaid A, Sousa A, Seixas AC, da Silva LM, Feres F, Pinto I, Mattos LA, Virmani R. Images in cardiovascular medicine: vascular healing 4 years after the implantation of sirolimus-eluting stent in humans: a histopathological examination. Circulation. 2004; 110: e5e6.
51. Suzuki T, Kopia G, Hayashi S, Bailey LR, Llanos G, Wilensky R, Klugherz BD, Papandreou G, Narayan P, Leon MB, Yeung AC, Tio F, Tsao PS, Falotico R, Carter AJ. Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model. Circulation. 2001; 104: 11881193.
52. Meredith IT. RESOLUTE: four-month angiographic and IVUS subset. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 2227, 2006; Washington, DC.
53. Rajtar A, Kaluza G, Yang Q, Hakimi D, Liu D, Tsui M, Lien M, Smith D, Clubb Jr F, Troczynski T. Hydroxyapatite-coated cardiovascular stents. Euro Intervention. 2006; 2: 113115.
54. Mehilli J, Kastrati A, Wessely R, Dibra A, Hausleiter J, Jaschke B, Dirschinger J, Schomig A. Randomized trial of a nonpolymer-based rapamycin-eluting stent versus a polymer-based paclitaxel-eluting stent for the reduction of late lumen loss. Circulation. 2006; 113: 273279.
55. Gupta V, Aravamuthan BR, Baskerville S, Smith SK, Gupta V, Lauer MA, Fischell TA. Reduction of subacute stent thrombosis (SAT) using heparin-coated stents in a large-scale, real world registry. J Invasive Cardiol. 2004; 16: 304310.[Medline] [Order article via Infotrieve]
56. Tepe G, Wendel HP, Khorchidi S, Schmehl J, Wiskirchen J, Pusich B, Claussen CD, Duda SH. Thrombogenicity of various endovascular stent types: an in vitro evaluation. J Vasc Interv Radiol. 2002; 13: 10291035.[Medline] [Order article via Infotrieve]
57. Vogt F, Stein A, Rettemeier G, Krott N, Hoffmann R, vom Dahl J, Bosserhoff AK, Michaeli W, Hanrath P, Weber C, Blindt R. Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent. Eur Heart J. 2004; 25: 13301340.
58. Tamai H, Igaki K, Kyo E, Kosuga K, Kawashima A, Matsui S, Komori H, Tsuji T, Motohara S, Uehata H. Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans. Circulation. 2000; 102: 399404.
59. Kukreja N, Otsuka M, Van Mieghem CA, Ligthart J, Sianos G, Serruys P. Biodegradable drug eluting stents: invasive and non-invasive imaging. Euro Intervention. 2006; 2: 403.
60. Ormiston J. ABSORB: first-in-man registry with the BVS bioabsorbable stent: thirty-day safety results. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 2227, 2006; Washington, DC.
61. Tanimoto S. TCT-306: acute stent recoil of bioabsorbable evelorimus eluting coronary stent: in vivo evaluation. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 2227, 2006; Washington, DC.
62. Heublein B, Rohde R, Kaese V, Niemeyer M, Hartung W, Haverich A. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? Heart. 2003; 89: 651656.
63. Di Mario C, Griffiths H, Goktekin O, Peeters N, Verbist J, Bosiers M, Deloose K, Heublein B, Rohde R, Kasese V, Ilsley C, Erbel R. Drug-eluting bioabsorbable magnesium stent. J Interv Cardiol. 2004; 17: 391395.[CrossRef][Medline] [Order article via Infotrieve]
64. Erbel R, Di Mario C, Bartunek J, Bonnier J, de Bruyne B, Eberli FR, Erne P, Haude M, Heublein B, Horrigan M, Ilsley C, Bose D, Koolen J, Luscher TF, Weissman N, Waksman R. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial. Lancet. 2007; 369: 18691875.[CrossRef][Medline] [Order article via Infotrieve]
65. Cato AC, Wade E. Molecular mechanisms of anti-inflammatory action of glucocorticoids. Bioessays. 1996; 18: 371378.[CrossRef][Medline] [Order article via Infotrieve]
66. Pepine CJ, Hirshfeld JW, Macdonald RG, Henderson MA, Bass TA, Goldberg S, Savage MP, Vetrovec G, Cowley M, Taussig AS; M-HEART Group. A controlled trial of corticosteroids to prevent restenosis after coronary angioplasty. Circulation. 1990; 81: 17531761.
67. Stone GW, Rutherford BD, McConahay DR, Johnson WL, Giorgi LV, Ligon RW, Hartzler GO. A randomized trial of corticosteroids for the prevention of restenosis in 102 patients undergoing repeat coronary angioplasty. Cathet Cardiovasc Diagn. 1989; 18: 227231.[Medline] [Order article via Infotrieve]
68. Chen YE, Burke SE, Toner JL. Abbott Laboratories, Internal Scientific Report No. 51R-002-AP-03-R1. Abbott Park, Ill: Abbott Laboratories; 2004.
69. Liu X, Huang Y, Hanet C, Vandormael M, Legrand V, Dens J, Vandenbossche JL, Missault L, Vrints C, De Scheerder I. Study of antirestenosis with the BiodivYsio dexamethasone-eluting stent (STRIDE): a first-in-human multicenter pilot trial. Catheter Cardiovasc Interv. 2003; 60: 172178; discussion 179.[CrossRef][Medline] [Order article via Infotrieve]
70. Ribichini F. DESIRE: Dexamethasone Stent Italian Registry: A Nationwide Study in Acute Coronary Syndrome Patients. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; September 27October 1, 2004; Washington, DC.
71. Asahara T, Murohara T, Sullivan A, Silver M, van der Zee R, Li T, Witzenbichler B, Schatteman G, Isner JM. Isolation of putative progenitor endothelial cells for angiogenesis. Science. 1997; 275: 964967.
72. Aoki J, Serruys PW, van Beusekom H, Ong AT, McFadden EP, Sianos G, van der Giessen WJ, Regar E, de Feyter PJ, Davis HR, Rowland S, Kutryk MJ. Endothelial progenitor cell capture by stents coated with antibody against CD34: the HEALING-FIM (Healthy Endothelial Accelerated Lining Inhibits Neointimal Growth-First In Man) Registry. J Am Coll Cardiol. 2005; 45: 15741579.
73. Serruys P. The genous endothelial cell capture system final results from the HEALING II study. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 1721, 2005; Washington, DC.
74. Vasa M, Fichtlscherer S, Adler K, Aicher A, Martin H, Zeiher AM, Dimmeler S. Increase in circulating endothelial progenitor cells by statin therapy in patients with stable coronary artery disease. Circulation. 2001; 103: 28852890.
75. Serruys PW, Sianos G, Abizaid A, Aoki J, den Heijer P, Bonnier H, Smits P, McClean D, Verheye S, Belardi J, Condado J, Pieper M, Gambone L, Bressers M, Symons J, Sousa E, Litvack F. The effect of variable dose and release kinetics on neointimal hyperplasia using a novel paclitaxel-eluting stent platform: the Paclitaxel In-Stent Controlled Elution Study (PISCES). J Am Coll Cardiol. 2005; 46: 253260.
76. Aoki J, AT O, Abizaid A, Den Heijer P, Bonnier H, McClean D, Verheye S, Belardi J, Condado J, Pieper M, Sousa E, Bressers M, Symons J, Litvack F, Sianos G, Serruys PW. One-year clinical outcome of various doses and pharmacokinetic release formulations of paclitaxel eluted from an erodable polymer: insight in the Paclitaxel In-Stent Controlled Elution Study (PISCES). Euro Intervention. 2005; 1: 165172.
77. Serruys PW. The SCEPTER trial: study of controlled elution of paclitaxel for the elimination of restenosis. Paper presented at: Congress of the European Society of Cardiology; September 47, 2005; Stockholm, Sweden.
78. Serruys PW. The new Costar TM stent: twelve-month results with the new DES technology. Paper presented at: Congress of the EuroPCR; May 2425, 2005; Paris, France.
79. Dawkins K. TAXUS VI: randomised trial of moderate-rate release polymer-based Paclitaxel-eluting TAXUS stent for the treatment of longer lesions: three-year clinical results. Paper presented at: Congress of the EuroPCR; May 1619, 2006; Paris, France.
80. Mehran R, Lansky A, Moses JW, Nikolsky E, Patel B, Trauthen B, Verheye S, Dens J, Thomas T, Onyebuchi C, Chenault A, Bajraktari F, Grube E. AXXENT stent for the treatment of left main coronary artery bifurcation lesions. Am J Cardiol. 2006; 98: TCT113.
81. Lefevre T, Ormiston J, Guagliumi G, Schultheiss HP, Quilliet L, Reimers B, Brunel P, Wijns W, Buettner HJ, Hartmann F, Veldhof S, Miquel K, Su X, van der Giessen WJ. The Frontier stent registry: safety and feasibility of a novel dedicated stent for the treatment of bifurcation coronary artery lesions. J Am Coll Cardiol. 2005; 46: 592598.
82. De Scheerder I. Batistimat (BB-94) anti-restenosis trial utilizing the BiodivYsio local drug-delivery PC-stent (BRILLIANT-EU-trial). Paper presented at: Congress of the European Society of Cardiology; August 30September 3, 2003; Vienna, Austria.
83. Serruys PW, Ormiston JA, Sianos G, Sousa JE, Grube E, den Heijer P, de Feyter P, Buszman P, Schomig A, Marco J, Polonski L, Thuesen L, Zeiher AM, Bett JH, Suttorp MJ, Glogar HD, Pitney M, Wilkins GT, Whitbourn R, Veldhof S, Miquel K, Johnson R, Coleman L, Virmani R. Actinomycin-eluting stent for coronary revascularization: a randomized feasibility and safety study: the ACTION trial. J Am Coll Cardiol. 2004; 44: 13631367.
84. Grube E. The Jomed drug-eluting stent program. Paper presented at: American Heart Association Annual Scientific Sessions; November 912, 2003; Orlando, Fla.
85. Morice MC, Colombo A, Meier B, Serruys P, Tamburino C, Guagliumi G, Sousa E, Stoll HP. Sirolimus- vs paclitaxel-eluting stents in de novo coronary artery lesions: the REALITY trial: a randomized controlled trial. JAMA. 2006; 295: 895904.
86. Goy JJ, Stauffer JC, Siegenthaler M, Benoit A, Seydoux C. A prospective randomized comparison between paclitaxel and sirolimus stents in the real world of interventional cardiology: the TAXI trial. J Am Coll Cardiol. 2005; 45: 308311.
87. de Lezo JMA, Pan M. Drug-eluting stents for complex lesions: randomized rapamycin versus paclitaxel CORPAL study. J Am Coll Cardiol. 2005; 45 (Suppl): 75a. Abstract.
88. Windecker S, Remondino A, Eberli FR, Juni P, Raber L, Wenaweser P, Togni M, Billinger M, Tuller D, Seiler C, Roffi M, Corti R, Sutsch G, Maier W, Luscher T, Hess OM, Egger M, Meier B. Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization. N Engl J Med. 2005; 353: 653662.
89. Kastrati A, Mehilli J, von Beckerath N, Dibra A, Hausleiter J, Pache J, Schuhlen H, Schmitt C, Dirschinger J, Schomig A. Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis: a randomized controlled trial. JAMA. 2005; 293: 165171.
90. Dibra A, Kastrati A, Mehilli J, Pache J, Schuhlen H, von Beckerath N, Ulm K, Wessely R, Dirschinger J, Schomig A. Paclitaxel-eluting or sirolimus-eluting stents to prevent restenosis in diabetic patients. N Engl J Med. 2005; 353: 663670.
91. Kaiser C, Brunner-La Rocca HP, Buser PT, Bonetti PO, Osswald S, Linka A, Bernheim A, Zutter A, Zellweger M, Grize L, Pfisterer ME. Incremental cost-effectiveness of drug-eluting stents compared with a third-generation bare-metal stent in a real-world setting: randomised Basel Stent Kosten Effektivitats Trial (BASKET). Lancet. 2005; 366: 921929.[CrossRef][Medline] [Order article via Infotrieve]
92. Kastrati A, Dibra A, Eberle S, Mehilli J, Suarez de Lezo J, Goy JJ, Ulm K, Schomig A. Sirolimus-eluting stents vs paclitaxel-eluting stents in patients with coronary artery disease: meta-analysis of randomized trials. JAMA. 2005; 294: 819825.
93. Windecker S. CYPHER vs TAXUS: an independent patient-based meta-analysis including the currently completed randomized controlled trials. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 1721, 2005; Washington, DC.
94. Daemen J, Tsuchida K, Stefanini G, Vaina S, Kukreja N, De Jaegere P, Ong A, Van Domburg R, Serruys PW. Two-Year clinical follow-up of the unrestricted use of the paclitaxel-eluting stent compared to the sirolimus-eluting stent as part of the Taxus-stent evaluated at Rotterdam Cardiology Hospital (T-SEARCH) Registry. Euro Intervention. 2006; 6: 330337.
95. Simonton CA. Nonrandomized Comparison of Late Clinical Outcomes With Paclitaxel-Eluting and Sirolimus-Eluting Stents From a Large Multicenter Registry. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; October 1721, 2005; Washington, DC.
96. Kaul U. Erodable Polymer-Reservoir Paclitaxel Drug Eluting Stents II: Cobalt Chromium Platforms in Complex Lesions. Paper presented at: Transcatheter Cardiovascular Therapeutics Symposium; September 27October 1, 2004; Washington, DC.
97. Dawkins K. The EUROSTAR trial. Paper presented at: Congress of the EuroPCR; May 2427, 2005; Paris, France.
This article has been cited by other articles:
![]() |
C. M. van Tiel, P. I. Bonta, S. Z.H. Rittersma, M. A.M. Beijk, E. J. Bradley, A. M. Klous, K. T. Koch, F. Baas, J. W. Jukema, D. Pons, et al. p27kip1-838C>A Single Nucleotide Polymorphism Is Associated With Restenosis Risk After Coronary Stenting and Modulates p27kip1 Promoter Activity Circulation, August 25, 2009; 120(8): 669 - 676. [Abstract] [Full Text] [PDF] |
||||
![]() |
K.-Y. Chen, S.-W. Rha, Y.-J. Li, K. L. Poddar, Z. Jin, Y. Minami, L. Wang, E. J. Kim, C. G. Park, H. S. Seo, et al. Triple Versus Dual Antiplatelet Therapy in Patients With Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention Circulation, June 30, 2009; 119(25): 3207 - 3214. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Ota, M. Eto, J. Ako, S. Ogawa, K. Iijima, M. Akishita, and Y. Ouchi Sirolimus and everolimus induce endothelial cellular senescence via sirtuin 1 down-regulation: therapeutic implication of cilostazol after drug-eluting stent implantation. J. Am. Coll. Cardiol., June 16, 2009; 53(24): 2298 - 2305. [Abstract] [Full Text] [PDF] |
||||
![]() |
Authors/writing members:, J. Daemen, M. L. Simoons, W. Wijns, A. Bagust, G. Bos, J. M. Bowen, E. Braunwald, E. Camenzind, B. Chevalier, et al. Meeting Report: ESC Forum on Drug Eluting Stents European Heart House, Nice, 27-28 September 2007 Eur. Heart J., January 2, 2009; 30(2): 152 - 161. [Full Text] [PDF] |
||||
![]() |
I. J. Sarembock From Systemic Shotgun to Site-Specific Nanoparticle-Targeted Delivery: A New Paradigm for Drug Delivery Arterioscler Thromb Vasc Biol, November 1, 2008; 28(11): 1879 - 1881. [Full Text] [PDF] |
||||
![]() |
J. Mehilli, R. A. Byrne, A. Wieczorek, R. Iijima, S. Schulz, O. Bruskina, J. Pache, R. Wessely, A. Schomig, A. Kastrati, et al. Randomized trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis Eur. Heart J., August 2, 2008; 29(16): 1975 - 1982. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. R. Dixon, C. L. Grines, and W. W. O'Neill The year in interventional cardiology. J. Am. Coll. Cardiol., June 17, 2008; 51(24): 2355 - 2369. [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2007 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |