(Circulation. 2007;115:1170-1176.)
© 2007 American Heart Association, Inc.
AHA/HRS Scientific Statement |
| Abstract |
|---|
|
|
|---|
Objective The issue of driving for patients with ICDs implanted for primary prevention was briefly discussed in the original statement, with the recommendation that such patients not be restricted from driving beyond the initial phase of healing. This scientific statement has been developed to extend the original 1996 recommendations and to provide specific recommendations on driving for individuals with ICDs implanted for primary prevention.
Summary of Recommendations (1) Patients receiving ICDs for primary prevention should be restricted from driving a private automobile for at least 1 week to allow for recovery from implantation of the defibrillator. Thereafter, these driving privileges should not be restricted in the absence of symptoms potentially related to an arrhythmia. (2) Patients who have received an ICD for primary prevention who subsequently receive an appropriate therapy for ventricular tachycardia or ventricular fibrillation, especially with symptoms of cerebral hypoperfusion, should then be considered to be subject to the driving guidelines previously published for patients who received an ICD for secondary prevention. (3) Patients with ICDs for primary prevention must be instructed that impairment of consciousness is a possible future event. (4) These recommendations do not apply to the licensing of commercial drivers.
Key Words: AHA Scientific Statements prevention defibrillation death, sudden arrhythmias
| Introduction |
|---|
|
|
|---|
Since the original publication of that medical/scientific statement, multiple trials have been reported that established the role of implantable cardioverter-defibrillators (ICDs) for the primary prevention of sudden cardiac death in patients at risk for life-threatening ventricular arrhythmias who have never had sustained VT or VF.512 Studies showing the efficacy of the ICD for the primary prevention of sudden arrhythmic death include the Multicenter Automatic Defibrillator Implantation Trials I5 and II8 (MADIT I and II), the Multicenter UnSustained Tachycardia Trial (MUSTT),7 the Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) Trial,9 and the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT).10 On the basis of the results of these trials, in early 2005, the Centers for Medicare and Medicaid Services expanded the coverage of ICDs for patients with a primary prevention indication for ICD therapy. As a consequence, considerable growth in the prescription of ICDs for such patients has occurred. It may be noted, however, that the term "primary prevention" is somewhat imperfect in that patients with inducible sustained VT in the setting of clinical nonsustained VT were included in the MADIT I and MUSTT primary prevention trials. Similarly, the Canadian Implantable Defibrillator Study (CIDS) secondary prevention trial included patients without documented spontaneous sustained VT or VF but who had inducible VT. Notably, the Centers for Medicare and Medicaid Services covers reimbursement for such patients irrespective of their being classified as having primary or secondary prevention implantation indications.
The recommendations from the 1996 publication regarding public safety issues for patients with ICDs placed for secondary prevention purposes after an episode of sustained VT or VF1 are still appropriate and do not need to be comprehensively revised; however, these recommendations are not appropriate for patients with primary prevention or "prophylactic" ICDs. In the absence of guidance to the contrary, some physicians and healthcare providers may inappropriately apply the restrictive recommendations published in 1996 for patients with ICDs implanted for secondary prevention to those patients with devices implanted for primary prevention.
The issue of driving for patients with ICDs implanted for primary prevention was briefly discussed in the original statement, with the recommendation that such patients not be restricted from driving beyond the initial phase of healing. Nevertheless, because these patients are at risk for complete or partial loss of consciousness if an arrhythmia occurs, and because questions about activities that are safe for them commonly arise, there is a need to update the recommendations for those patients receiving prophylactic ICDs.
The present scientific statement has been developed to extend the original 1996 recommendations and to provide recommendations regarding individuals with ICDs implanted for primary prevention who may undertake activities, specifically driving, that may put themselves or others at risk if consciousness were to be impaired by a cardiac arrhythmia.
| Risk of Arrhythmia Occurrence in Patients With ICDs |
|---|
|
|
|---|
Results of Primary Prevention ICD Trials
Table 1 lists those trials that address the benefits of ICD therapy versus control or conventional therapy in patients at risk for life-threatening ventricular arrhythmias who have never had sustained VT or VF. Inclusion criteria for the different trials varied, as would be expected from a series of trials that were initiated between 1990 and 2000. One trial, the Coronary Artery Bypass Graft Patch (CABG-Patch) Trial, was confined to patients undergoing coronary bypass surgery.6 The Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Trial was primarily designed to address the role of cardiac resynchronization therapy; nevertheless, one arm evaluated ICD plus biventricular pacing therapy.11 Patients with nonischemic cardiomyopathy were included in 3 of the primary prevention ICD trials.911
|
For the purposes of the present statement, the focus of consideration of these trials is on the event rates in patients randomized to receive an ICD. Annualized mortality rates range from 1.6% of patients per year in the MADIT II trial5 to 12% of patients per year in the COMPANION trial of patients with New York Heart Association class III to IV congestive heart failure.11 Annualized mortality rates in the other 6 trials ranged from 4% to 8.5% of patients per year. The average annual mortality in the ICD arms of these randomized trials was
7% of patients per year, which reflects the patient inclusion criteria of left ventricular dysfunction and/or congestive heart failure. Rates of sudden cardiac or arrhythmic deaths reported in 4 trials are extremely low, ranging from 0.5% to
1.7% of patients per year, likely a reflection of the efficacy of the ICD, as shown in Table 1.
ICD Discharges
Table 2 summarizes the published data from the randomized trials of primary prevention of sudden cardiac death relative to the rate of ICD shocks during follow-up. These data arguably provide the most important information on the risks of driving in this patient subset.
|
In 2 trials that used earlier-generation ICDs, device discharge rates were high. In the CABG-Patch Trial, 50% of patients received a discharge during 1 year of follow-up6; in MADIT I, 60% of patients received a discharge during 2 years of follow-up.5 In a small study of 41 patients followed up for 21 months who fulfilled the criteria for entry into the MADIT I trial, 43.9% of patients received 142 appropriate ICD treatments, of which 17.6% were ICD discharges, which corresponds to a rate of only 4.4% per year.13
The rates of ICD discharges in more recent trials are quite consistent. In DEFINITE, discharges occurred at a rate of 7.4% of patients per year (41 patients received 91 shocks).9 A subsequent analysis reported that only 70 (44.9%) of 156 shocks were appropriate.14 In SCD-HeFT, 259 (31%) of the 829 patients with ICDs received shocks for any reason, with 177 of these shocks being for VF or rapid VT (68% of patients who were shocked, or 21% of patients with ICDs). During 5 years of follow-up, the annual rate of appropriate ICD discharge was 7.5% per year. For rapid sustained VT or VF, the rate of appropriate ICD discharge was 5.1% per year. The number of patients in this group with impairment or loss of consciousness during these episodes was not reported.10
There is a paucity of data on symptoms accompanying ICD discharges.15,16 In a subgroup of patients in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial of patients who had been previously resuscitated from near-fatal ventricular tachyarrhythmias, among 295 patients who resumed driving after receiving an ICD, 8% reported receiving a shock while driving.16 Among the 559 of the 627 patients who completed a questionnaire and had resumed driving, 2% reported loss of consciousness while driving, and 11% reported dizziness or palpitations that necessitated stopping the vehicle.
Temporal Aspects of Device Therapy
In patients who have sustained a myocardial infarction, there is increasing evidence that the benefit of an ICD increases over time after the incident myocardial infarction.17 In the Defibrillator in Acute Myocardial Infarction Trial (DINAMIT), which enrolled patients within 8 to 40 days of the incident myocardial infarction, there was no mortality benefit from use of an ICD.12 Nevertheless, the risk of sudden cardiac death/cardiac arrest in patients with a recent myocardial infarction and either left ventricular dysfunction or congestive heart failure is highest in the first 30 days after infarction.18 In the Valsartan in Acute Myocardial Infarction Trial (VALIANT), the risk of sudden cardiac death/cardiac arrest was 1.4% per month in the first 30 days after a myocardial infarction, 0.5% per month during months 1 to 6 after a myocardial infarction, and 0.27% per month during months 7 to 12 after a myocardial infarction, with a significant decline thereafter to 0.14% per month after 4 years.18 The lack of ICD benefit early after myocardial infarction contrasts with the increased rate of sudden cardiac death during this period. It has been suggested that ventricular tachyarrhythmias that lead to ICD discharge in the early postinfarction period may be a surrogate marker for other causes of death during this time period,19 such as congestive heart failure.20 On the other hand, ventricular tachyarrhythmias that lead to ICD discharge months or years after myocardial infarction may be unassociated with other premorbid conditions, thereby permitting such patients to realize a long-term benefit from ICD therapy.16,2023
From the standpoint of driving privileges, the benefit or lack thereof from an ICD is not relevant; the pivotal factor is the actual rate of events that could lead to loss of control of a motor vehicle, such as VF, VT with hemodynamic instability, syncope, sudden cardiac death, or ICD discharge. Patients randomized in the AVID Trial reported resuming driving early regardless of medical advice to the contrary (80% were driving within 6 months), reported driving frequently (57% reported driving every day), and reported driving significant distances (25% were driving >100 miles/wk).16 However, these patients, who had survived a near-fatal episode of ventricular arrhythmia, had a very low rate of automobile accidents. Indeed, the frequency of automobile accidents (3.4% of patients per year) was less than that of the general driving population of the United States (7.1% patients per year).16 Nevertheless, the relatively high event rate soon after the index episode of ventricular tachyarrhythmias led to a suggestion that driving be restricted for all patients for 1 month and for most patients up to 8 months after such an event.15
The average person with an ICD drives 8 to 20 miles per day for purely personal reasons.24 That distance would indicate that the typical private driver with an ICD spends
30 minutes per day behind the wheel, which is
2% of the day. Coupling these data with those of the SCD-HeFT, DEFINITE, and MADIT II trials of primary prevention, which demonstrated ICD discharge rates of
7.5% of patients per year, the likelihood of an ICD discharge while driving may be predicted to be in the range of 0.15% of patients per year. Even if each patient treated by his or her ICD receives >1 shock during any given year, and even if other nonshock ICD therapies, including antitachycardia pacing, were considered to be a possible source of incapacitation, the likelihood of an event while driving is <1%. Variations in cardiac and arrhythmia event rates throughout the day,25 as well as circadian patterns as a function of day of the week26 and season,27 may also affect ICD usage rates.
Nevertheless, the period immediately after ICD implantation represents an unstable state awaiting maturation of the patient-ICD interface. It is during this period of time that many ICD complications occur, including the occurrence of inappropriate shocks. Accordingly, it is appropriate to advise restriction of private automobile driving privileges for the period of recovery from implantation of an ICD for primary prevention. In the absence of data regarding the optimal time for such restriction, a period of at least 1 week is recommended. Thereafter, no private automobile driving restrictions need be applied to patients who are asymptomatic from an arrhythmia standpoint.
A particularly difficult issue for patients and physicians is how to handle a patient with a device implanted for primary prevention who receives therapy, appropriate or inappropriate. Questions that arise include: Should this patient be treated now as a secondary prevention patient and have driving restricted for 6 months?1 Is the patient treated as a secondary prevention patient only if a shock is delivered versus antitachycardia pacing therapy? Should the patient be treated as a secondary prevention patient only if impaired consciousness occurs with the tachycardia? Unfortunately, no data are available for guidance in this area. However, if we extrapolate from secondary prevention trials, event rates are highest in the weeks and months after a ventricular arrhythmia event and then fall.15 Furthermore, antitachycardia pacing may accelerate VT.28,29 Thus, given the uncertainty of their subsequent clinical course, receipt of appropriate therapy for VT or VF, especially with symptoms of cerebral hypoperfusion, warrants transitioning from rules of primary prevention to those of secondary prevention, ie, restriction from driving, noting that the future clinical course is unpredictable.1,15 Because the risk to patients and others is significant if there is an important chance for syncope, it appears inappropriate to support driving in such patients.
Finally, these guidelines focus on the arrhythmia potential of patients with ICDs; however, many of these patients have other important illnesses, both cardiac and noncardiac, that may affect driving ability. Indeed, there are often other reasons to restrict these patients from driving, including such unstable medical situations as frequent angina, heart failure, and significant dyspnea with minimal activity. These patients may not have had any tachycardia, yet have an ICD implanted and still have contraindications to driving. Healthcare providers have a responsibility to consider these factors and address them when making recommendations to individual patients.
| Ethics, Autonomy, Regulation, the Law, and Social Responsibility |
|---|
|
|
|---|
A distinguishing quality of any profession is its acceptance of responsibility to society and the public interest, defined as the collective well-being of the people whom the profession serves. In medicine, ethics deals with issues of medical practice, of medical research, and of public policy as it relates to the health of society.30 Integrity is a fundamental aspect of any profession, but especially of medicine, and requires that physicians observe the ideals of objectivity and independence. Because any regulation of activity may have a tremendous impact on the individual, particular attention is given to the ethical issues related to regulation of activities of patients with arrhythmias.
In American society, there is a constant conflict between the rights of the individual and the good of society.30 The individual is given the right to act in whatever manner he or she chooses as long as that act does not impinge on the rights of others. The latter requirement demands that limits be placed on the rights of the individual just as limits are placed on the rights of society to restrict individual action. Ethics tries to address the delicate balance between these 2 conflicting principles.
In American society, individual mobility and access to education, employment, health maintenance, and personal enrichment opportunities are highly dependent on the automobile. Being unable to drive puts limitations on the individual, which results in both emotional stress and loss of economic status. At the same time, the citizens of a society have the right to protect themselves against the harm caused by individuals who are unable to operate a motor vehicle in a safe and prudent manner. In a just and open society, all individuals are treated equally. Therefore, restrictions on the driving ability of patients with arrhythmias must be clearly elaborated and applied uniformly to all.
The physician and other healthcare professionals are bound to uphold the confidentiality of information regarding a patients medical condition, and such information is shared with others only when consent is given by the patient.31 If a patient requests that medical information be withheld from his or her employer, the ethical physician will not comply with the patients request if doing so would pose a risk to others. In such instances, the patient should be asked to release this information. If, however, the patient does not agree, the physician is bound to breach confidentiality. Although breaking the principle of confidentiality may result in legal action by the patient against the physician, the ethical responsibilities of beneficence ("do good and avoid evil") and nonmaleficence ("do no harm") take precedence over the principle of confidentiality in this setting. In such situations, the ethical course is for the physician to release the required information to the proper authorities, such as the state or national departments of transportation, while providing full disclosure to the patient.32
| Limitations |
|---|
|
|
|---|
| Recommendation Summary |
|---|
|
|
|---|
|
| Acknowledgments |
|---|
|
|
| Footnotes |
|---|
The American Heart Association and the Heart Rhythm Society make every effort to avoid any actual or potential conflicts of interest that may arise as a result of an outside relationship or a personal, professional, or business interest of a member of the writing panel. Specifically, all members of the writing group are required to complete and submit a Disclosure Questionnaire showing all such relationships that might be perceived as real or potential conflicts of interest.
This statement was approved by the American Heart Association Science Advisory and Coordinating Committee on October 13, 2006, and by the Heart Rhythm Society on September 22, 2006.
This article has been copublished in the March 2007 issue of Heart Rhythm.
Copies: A single reprint is available by calling 800-242-8721 (US only) or writing the American Heart Association, Public Information, 7272 Greenville Ave, Dallas, TX 75231-4596. Ask for reprint No. 71-0392. To purchase additional reprints: Up to 999 copies, call 800-611-6083 (US only) or fax 413-665-2671; 1000 or more copies, call 410-528-4121, fax 410-528-4264, or e-mail kelle.ramsay@wolterskluwer.com.
Permissions: Multiple copies, modification, alteration, enhancement, and/or distribution of this document are not permitted without the express permission of the American Heart Association. Instructions for obtaining permission are located at http://www.americanheart.org/presenter.jhtml?Identifier=4431. A link to the "Permission Request Form" appears on the right side of the page.
© 2007 American Heart Association, Inc., and the Heart Rhythm Society.
| References |
|---|
|
|
|---|
2. The Antiarrhythmics Versus Implantable Defibrillators (AVID) Investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal sustained ventricular arrhythmias. N Engl J Med. 1997; 337: 15761583.
3. Connolly SJ, Gent M, Roberts RS, Dorian P, Roy D, Sheldon RS, Mitchell LB, Green MS, Klein GJ, OBrien B; for the CIDS Investigators. Canadian Implantable Defibrillator Study (CIDS): a randomized trial of the implantable cardioverter defibrillator against amiodarone. Circulation. 2000; 101: 12971302.
4. Kuck KH, Cappato R, Siebels J, Rüppel R; for the CASH Investigators. Randomized comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from cardiac arrest: the Cardiac Arrest Study Hamburg (CASH). Circulation. 2000; 102: 748754.
5. Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, Levine JH, Saksena S, Waldo AL, Wilber D, Brown MW, Heo M; Multicenter Automatic Defibrillator Implantation Trial Investigators. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmias. N Engl J Med. 1996; 335: 19331940.
6. Bigger JT Jr; for the Coronary Artery Bypass Graft (CABG) Patch Trial Investigators. Prophylactic use of implantable cardiac defibrillators in patients at high risk for ventricular arrhythmias after coronary artery bypass graft surgery. N Engl J Med. 1997; 337: 15691575.
7. Buxton AE, Lee KL, Fisher JD, Josephson ME, Prystowsky EN, Hafley G; for the Multicenter Unsustained Tachycardia Trial Investigators. A randomized study of the prevention of sudden death in patients with coronary artery disease [published correction appears in N Engl J Med. 2000;342:1300]. N Engl J Med. 1999; 341: 18821890.
8. Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews ML; Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002; 346: 877883.
9. Kadish A, Dyer A, Daubert JP, Quigg R, Estes NAM, Anderson KP, Calkins H, Hoch D, Goldberg J, Shalaby A, Sanders WE, Schaechter A, Levine JH; Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) Investigators. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med. 2004: 350; 21512158.
10. Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, Domanski M, Troutman C, Anderson J, Johnson G, McNulty SE, Clapp-Channing N, Davidson-Ray LD, Fraulo ES, Fishbein DP, Luceri RM, Ip JH; for the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [published correction appears in N Engl J Med. 2005;352:2146]. N Engl J Med. 2005; 352: 225237.
11. Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, DeMarco T, Carson P, DiCarlo L, DeMets D, White BG, DeVries DW, Feldman AM; for the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med. 2004; 350: 21402150.
12. Hohnloser SH, Kuck KH, Dorian P, Roberts RS, Hampton JR, Hatala R, Fain E, Gent M, Connolly SJ; on behalf of the DINAMIT Investigators. Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction. N Engl J Med. 2004; 351: 24812488.
13. Wolpert C, Kuschyk J, Aramin N, Spehl S, Streitner F, Süselbeck T, Schumacher B, Haase KK, Schimpf R, Borggrefe M. Incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias in high risk coronary patients and prophylactic implantation of a defibrillator. Heart. 2004; 90: 667671.
14. Ellenbogen KA, Levine JH, Berger RD, Daubert JP, Winters SL, Greenstein E, Shalaby A, Schaechter A, Subacius H, Kadish A; for the Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) Investigators. Are implantable cardioverter defibrillator shocks a surrogate for sudden cardiac death in patients with nonischemic cardiomyopathy? Circulation. 2006; 113: 776782.
15. Larsen GC, Stupey MR, Walance CG, Griffith KK, Cutler JE, Kron J, McAnulty JH. Recurrent cardiac events in survivors of ventricular fibrillation or tachycardia: implications for driving restrictions. JAMA. 1994; 271: 13351339.
16. Akiyama T, Powell JL, Mitchell LB, Ehlert FA, Baessler C; for the Antiarrhythmics Versus Implantable Defibrillator Investigators. Resumption of driving after life-threatening ventricular tachyarrhythmia. N Engl J Med. 2001; 345: 391397.
17. Wilber DJ, Zareba W, Hall WJ, Brown MW, Lin AC, Andrews ML, Burke M, Moss AJ. Time dependence of mortality risk and defibrillator benefit after myocardial infarction. Circulation. 2004; 109: 10821084.
18. Solomon SD, Zelenkofske S, McMurray JJV, Finn PV, Velazquez E, Ertl G, Harsanyi A, Rouleu JL, Maggioni A, Kober L, White H, Van de Werf F, Pieper K, Califf RM, Pfeffer MA; for the Valsartan in Acute Myocardial Infarction Trial (VALIANT) Investigators. Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both [published correction appears in N Engl J Med. 2005;353;744]. N Engl J Med. 2005; 352: 25812588.
19. Dorian P, Connolly S, Hohnloser SH, Goethe JW; on behalf of the DINAMIT Investigators. Why dont ICDs decrease all-cause mortality after MI? Insights from the DINAMIT Study. Circulation. 2004; 110 (suppl III): III-502.
20. Orn S, Cleland JGF, Romo M, Kjekshus J, Dickstein K. Recurrent infarction causes the most deaths following myocardial infarction with left ventricular dysfunction. Am J Med. 2005; 118: 752758.[CrossRef][Medline] [Order article via Infotrieve]
21. Salukhe TV, Dimopoulos K, Sutton R, Coats AJ, Piepoli M, Francis DP. Life-years gained from defibrillator implantation: markedly nonlinear increase during 3 years of follow-up and its implications. Circulation. 2004; 109: 18481853.
22. Greenberg H, Case RB, Moss AJ, Brown MW, Carroll ER, Andrews ML; for the MADIT-II Investigators. Analysis of mortality events in the Multicenter Automatic Defibrillator Implantation Trial (MADIT-II). J Am Coll Cardiol. 2004; 43: 14591465.
23. Moss AJ, Vyas A, Greenberg H, Case RB, Zareba W, Hall WJ, Brown MW, McNitt SA, Andrews ML; for the MADIT-II Research Group. Temporal aspects of improved survival with the implanted defibrillator (MADIT-II). Am J Cardiol. 2004; 94: 312315.[CrossRef][Medline] [Order article via Infotrieve]
24. Conti JB, Woodard DA, Tucker KJ, Bryant B, King LC, Curtis AB. Modification of patient driving behavior after implantation of a cardioverter defibrillator. Pacing Clin Electrophysiol. 1997; 20: 22002204.[CrossRef][Medline] [Order article via Infotrieve]
25. Lampert R, Rosenfeld L, Batsford W, Lee F, McPherson C. Circadian variation of sustained ventricular tachycardia in patients with coronary artery disease and implantable cardioverter-defibrillators. Circulation. 1994; 90: 241247.
26. Willich SN, Löwel H, Lewis M, Hörmann A, Arntz HR, Keil U. Weekly variation of acute myocardial infarction: increased Monday risk in the working population. Circulation. 1994; 90: 8793.
27. Müller D, Lampe F, Wegscheider K, Schultheiss HP, Behrens S. Annual distribution of ventricular tachycardias and ventricular fibrillation. Am Heart J. 2003; 146: 10611065.[CrossRef][Medline] [Order article via Infotrieve]
28. Wathen MS, Sweeney MO, DeGroot PJ, Stark AJ, Koehler JL, Chisner MB, Machado C, Adkisson WO; for the PainFREE Rx Investigators. Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease. Circulation. 2001; 104: 796801.
29. Wathen MS, DeGroot PJ, Sweeney MO, Stark AJ, Otterness MF, Adkisson WO, Canby RC, Khalighi K, Machado C, Rubenstein DS, Volosin KJ; for the PainFREE Rx II Investigators. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation. 2004; 110: 25912596.
30. Singer P. Practical Ethics. 2nd ed. Cambridge, UK: Cambridge University Press; 1999: 154.
31. Halberstam J. Everyday Ethics: Inspired Solutions to Real-Life Dilemmas. New York, NY: Viking; 1993: 324.
32. Council on Ethical and Judicial Affairs. Code of Medical Ethics of the American Medical Association. Chicago, Ill: AMA Press; 2004.
33. Blumenthal R, Braunstein J, Connolly H, Epstein A, Gersh BJ, Wittles EH. Cardiovascular Advisory Panel Guidelines for the Medical Examination of Commercial Motor Vehicle Drivers. US Department of Transportation, Federal Motor Carrier Safety Administration. Report No. FMCSA-MCP-02-002; October, 2002. Available at: http://www.fmcsa.dot.gov/documents/cardio.pdf. Accessed September 17, 2005.
This article has been cited by other articles:
![]() |
Task force members, J. Vijgen, G. Botto, J. Camm, C.-J. Hoijer, W. Jung, J.-Y. Le Heuzey, A. Lubinski, T. M. Norekval, M. Santomauro, et al. Consensus statement of the European Heart Rhythm Association: updated recommendations for driving by patients with implantable cardioverter defibrillators Europace, June 13, 2009; (2009) eup112v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. G. Benditt and J. T. Nguyen Syncope: therapeutic approaches. J. Am. Coll. Cardiol., May 12, 2009; 53(19): 1741 - 1751. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, D. L. Hayes, et al. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons J. Am. Coll. Cardiol., May 27, 2008; 51(21): e1 - e62. [Full Text] [PDF] |
||||
![]() |
A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, D. L. Hayes, et al. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons Circulation, May 27, 2008; 117(21): e350 - e408. [Full Text] [PDF] |
||||
![]() |
M. Rozner Management of Implanted Cardiac Defibrillators During Eye Surgery Anesth. Analg., February 1, 2008; 106(2): 671 - 672. [Full Text] [PDF] |
||||
![]() |
B. P. Grubb Driving and Implantable Cardioverter-Defibrillators: A Clearer View J. Am. Coll. Cardiol., December 4, 2007; 50(23): 2241 - 2242. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2007 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |