| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Circulation. 2007;115:3173-3180.)
© 2007 American Heart Association, Inc.
Heart Failure |
From the University of Toronto (M.A., J.S.F., A.G.L., P.H., C.R., G.T., T.D.B.), Toronto, Ontario, Canada; University of British Columbia (J.F.), Vancouver, British Columbia, Canada; University of Calgary (I.B., P.H.), Calgary, Alberta, Canada; University of Western Ontario (K.F.), London, Ontario, Canada; McGill University (R.J.K., M.S.), Montreal, Quebec, Canada; Laval University (F.S.), Quebec City, Quebec, Canada; Dalhousie University (D.M.), Halifax, Nova Scotia, Canada; and the University of Regensburg (M.P.), Regensburg, Germany.
Correspondence to T. Douglas Bradley, MD, Toronto General Hospital/University Health Network, 9N-943, 200 Elizabeth St, Toronto, Ontario, M5G 2C4, Canada. E-mail douglas.bradley{at}utoronto.ca
Received December 11, 2006; accepted April 9, 2007.
| Abstract |
|---|
|
|
|---|
Methods and Results Of the 258 heart failure patients with CSA in CANPAP, 110 of the 130 randomized to the control group and 100 of the 128 randomized to CPAP had sleep studies 3 months later. CPAP patients were divided post hoc into those whose apnea-hypopnea index was or was not reduced below 15 at this time (CPAP-CSA suppressed, n=57, and CPAP-CSA unsuppressed, n=43, respectively). Their changes in left ventricular ejection fraction and heart transplantfree survival were compared with those in the control group. Despite similar CPAP pressure and hours of use in the 2 groups, CPAP-CSAsuppressed subjects experienced a greater increase in left ventricular ejection fraction at 3 months (P=0.001) and significantly better transplant-free survival (hazard ratio [95% confidence interval] 0.371 [0.142 to 0.967], P=0.043) than control subjects, whereas the CPAP-CSAunsuppressed group did not (for left ventricular ejection fraction, P=0.984, and for transplant-free survival, hazard ratio 1.463 [95% confidence interval 0.751 to 2.850], P=0.260).
Conclusions These results suggest that in heart failure patients, CPAP might improve both left ventricular ejection fraction and heart transplantfree survival if CSA is suppressed soon after its initiation.
Key Words: apnea, sleep heart failure respiration sleep survival trials
| Introduction |
|---|
|
|
|---|
The Canadian Continuous Positive Airway Pressure for Patients with Central Sleep Apnea and Heart Failure Trial (CANPAP) was a randomized, controlled clinical trial involving 258 HF patients with CSA.7,8 This trial tested the hypothesis that treating CSA with continuous positive airway pressure (CPAP) would improve both survival without heart transplantation (heart transplantfree survival) and cardiovascular function.7 CPAP attenuated CSA, improved nocturnal oxygen saturation (SaO2), reduced sympathetic nervous activity, and increased left ventricular ejection fraction (LVEF) and 6-minute walking distance,8 yet heart transplantfree survival was not altered.
Editorial p 3140
Clinical Perspective p 3180
Previous studies suggest that alleviation of CSA is a key mechanism through which CPAP exerts its beneficial cardiovascular effects in patients with HF. For example, in several single-center trials in which CPAP reduced the apnea-hypopnea index (AHI) of HF patients with CSA by 65% to 75%, to below 15 per hour of sleep, it caused a significant improvement in LVEF.3,911 Reductions in AHI after 1 month of CPAP preceded this increase in LVEF, which did not appear until after 3 months of CPAP.10 In contrast, in a study in which CPAP did not suppress CSA in HF patients, left ventricular (LV) systolic function did not improve.12 In a small, single-center trial by Sin and colleagues,5 CPAP had no effect on LVEF or heart transplantfree survival in HF patients without CSA or obstructive sleep apnea. In contrast, in the same study, application of CPAP to HF patients with CSA increased LVEF in association with a strong trend toward improved heart transplantfree survival (P=0.056).
In CANPAP, CPAP caused a 53% fall in the mean AHI, from 40 to 19 per hour of sleep, and therefore did not reduce the average AHI to below the trial inclusion threshold of 15 per hour of sleep.7,8 This failure of CPAP to more completely reverse CSA may explain its more modest effect on LVEF (increase of 2.2% versus 8% in previous trials)3,5,10,11 and its failure to alter heart transplantfree survival. We therefore performed a post hoc analysis of the CANPAP database to test the hypothesis that greater suppression of CSA by CPAP to an AHI below the inclusion threshold of 15 per hour of sleep would improve LVEF and heart transplantfree survival.
| Methods |
|---|
|
|
|---|
Subjects
Candidates for participation in CANPAP included men and women aged 18 to 79 years with New York Heart Association class II to IV HF due to ischemic, hypertensive, or idiopathic dilated cardiomyopathy, stabilized with optimal medical therapy for at least 1 month; LVEF <40% by radionuclide angiography; and CSA. CSA was defined7 as an AHI
15, with >50% of apneas and hypopneas central in nature (see below). Exclusion criteria were pregnancy; myocardial infarction, unstable angina, or cardiac surgery within 3 months of enrollment; and obstructive sleep apnea.
Randomization
Eligible patients were randomized to either a control group who continued optimal medical HF therapy or a treatment group who, in addition, received CPAP. Randomization was performed by computerized schedule in random blocks of 4 and 6 and was stratified by study center. Treatment assignment was communicated to sites by the Data Management Center once it was verified that the patient was eligible. Subjects assigned to CPAP were further randomized in a 2:1:1 ratio to a Respironics REMstar Pro (Respironics, Inc; Murrysville, Pa), ResMed Sullivan VII (ResMed Corp; Poway, Calif), or Tyco Healthcare GoodKnight 420S (Tyco Healthcare; Mansfield, Mass) device, respectively. The use of CPAP devices from 3 different companies was a consequence of the arrangements made for study funding; no significant differences in heart transplantfree survival could be detected among the 3 devices (P=0.3).8
Baseline Assessment
Patients underwent clinical assessment followed by overnight polysomnography. Sleep stages and arousals, apneas and hypopneas, and mean and minimal arterial oxygen saturation (SaO2) were assessed according to uniform methods at all centers.8,10,13 Respiratory effort was measured by respiratory inductance plethysmography and airflow by nasal pressure.4,1417 Central apneas were defined as absent tidal volume for
10 seconds without thoracoabdominal motion10,16 and central hypopneas as a
50% reduction in tidal volume from baseline for
10 seconds without airflow limitation on nasal pressure.10,18 Apneas and hypopneas were classified as obstructive if out-of-phase thoracoabdominal motion or airflow limitation was present.16,18 Resting LVEF was determined by radionuclide angiography.
Initiation of CPAP
CPAP was initiated over 2 to 3 nights in an unmonitored sleep laboratory or hospital bed,3,10,11 starting at 5 cm H2O the first night, then increasing by 2 to 3 cm H2O over the subsequent 1 or 2 nights up to 10 cm H2O (a level shown to attenuate CSA and improve LVEF)5,10,11 or until the highest pressure tolerated was reached. Patients were instructed to use CPAP at least 6 hours nightly at home during the trial. If necessary, pressure was raised to 10 cm H2O or to the highest level tolerated at the 1- or 3-month follow-up visit. At each clinic visit, hours of CPAP use were downloaded from a mask-on time meter.
Assessments of Outcomes
Clinical assessments were performed 1, 3, and 6 months after randomization and every 6 months thereafter. Polysomnography was performed at 3 and 24 months, and LVEF was evaluated at 3, 6, and 24 months after randomization. Subjects were followed up from randomization until death, transplantation, or the end of the study. The primary outcome was the combined rate of all-cause mortality or heart transplantation, with subjects censored after transplantation or, if alive and transplantfree, at the end of follow-up. Time and cause of death or heart transplantation were ascertained from medical records or death certificates and were verified by an end-point adjudication committee.
To test the hypothesis that suppression of CSA by CPAP early in the trial was associated with improved LVEF and heart transplantfree survival, we evaluated only those subjects who underwent polysomnography at 3 months after enrollment. Because an AHI of
15 was the cutoff for inclusion in the trial,7,8 we stratified patients randomized to CPAP into those whose AHI was suppressed by CPAP to <15 at 3 months after randomization (CPAP-CSAsuppressed group) and those whose AHI remained
15 at this time (CPAP-CSAunsuppressed group).
In the CPAP group, the AHI was suppressed to <15 in 57 subjects (57%). However, because the AHI decreased spontaneously to <15 in only 12 subjects (11%) in the control group, the 2 CPAP groups were compared with the entire control group. Secondary outcomes included changes in AHI, mean nocturnal SaO2, and LVEF from baseline to 3 months.
Statistical Analysis
Baseline characteristics of patients in the 3 groups were compared by ANOVA with post hoc contrasts by t tests for continuous variables and by
2 or Fisher exact test for nominal variables as appropriate. Kaplan-Meier plots were used to visualize heart transplantfree survival. Multivariable Cox proportional hazards analysis was used to compare transplant-free survival in the control group with that in the CPAP-CSAsuppressed and the CPAP-CSAunsuppressed groups beginning 3 months after randomization at the time of the follow-up polysomnogram. We evaluated for potential confounding by introducing factors that were different between the groups at baseline and recorded factors known to increase the risk of cardiovascular death in HF patients into the models 1 at a time.4,5,19,20 These were sex, age, and baseline LVEF, New York Heart Association class, AHI, and percent central AHI, as well as the use of ß-blockers and angiotensin-converting enzyme inhibitors or angiotensin II receptor blockers.
We tested the equality of survival between the 3 groups with a likelihood ratio test; this compared Cox models with and without a variable that represented the group. When an overall difference was present, we computed hazard ratios (HRs) comparing each of the CPAP-treated subgroups with the entire control group.
We might also expect that patients having a spontaneous drop in AHI to <15 at 3 months in the control group would have a better outcome; however, in the present study, only 12 subjects in the control group experienced a drop in AHI to <15, and only 1 of these had a primary event. This leads to very low power for examining the effect of a reduction in AHI among control patients. Nevertheless, to evaluate the impact of a spontaneous drop in AHI on LVEF and transplant-free survival, we also compared change in LVEF and transplant-free survival between subjects in the control group whose AHI decreased spontaneously to <15 versus those whose AHI remained
15 at 3 months after enrollment.
Two-way repeated-measures ANOVA and Tukeys test were used to compare differences between groups in AHI, mean and minimal nocturnal SaO2, and LVEF measured at baseline and 3 months after enrollment. Paired t tests were used to compare differences within groups. All data analyses were generated by R (R Development Core Team, R Foundation for Statistical Computing, Vienna, Austria).21 All probability values are 2-sided.
The authors had full access to and take full responsibility for the integrity of the data. All authors have read and agree to the manuscript as written.
| Results |
|---|
|
|
|---|
15 in 43. Table 1 displays the baseline characteristics of the subjects. The mean AHI of between 34 and 47 events per hour indicates moderate to severe CSA in the 3 groups.
|
|
No statistically significant differences existed between the CPAP-CSAsuppressed and control groups in age, sex distribution, race, body mass index, severity and cause of HF, frequency of atrial fibrillation, LVEF, cardiac medications, AHI, or percentage of central apneas and hypopneas (Table 1). Patients in the CPAP-CSAunsuppressed group were also similar to controls with respect to all baseline characteristics, except they had a higher AHI and a higher percentage of central apneas and hypopneas. Compared with subjects from the CPAP-CSAsuppressed group, those from the CPAP-CSAunsuppressed group were significantly older, had significantly higher AHI, and had a higher percentage of central apneas and hypopneas. However, no significant difference existed in obstructive AHI between the CPAP-CSAsuppressed and unsuppressed groups at baseline (3.6 versus 3.3 events/h, P=0.994) or at 12 weeks (1.0 versus 2.4 events/h, P=0.956). In the CPAP-CSAsuppressed and unsuppressed groups, no significant difference existed in the proportion of subjects not taking a ß-blocker at the time of enrollment who were started on one during the course of the trial (5% and 12%, respectively; P=0.38).
Dropouts, Early Deaths, and CPAP Compliance
During the first 3 months after enrollment, 10 and 6 subjects, respectively, within the CPAP and control groups (10% and 5%) dropped out. After the sleep study at 3 months, 4 patients (7%) withdrew from the CPAP-CSAsuppressed group, 6 (14%) from the CPAP-CSAunsuppressed group, and 14 (13%) from the control group.
During the first 3 months after enrollment, 5 and 2 subjects from the CPAP and control groups, respectively, died. All 5 deaths in the CPAP group occurred at least 1 month after initiation of CPAP therapy. Their causes of death were progressive heart failure (n=2), myocardial infarction (n=1), and encephalopathy due to cardiac and renal failure (n=1) and to a ruptured abdominal aortic aneurysm (n=1). The 2 deaths in the control group within the first 3 months were attributed to progressive heart failure (n=1) and myocardial infarction (n=1).
No significant difference existed in compliance with CPAP between the CPAP-CSAsuppressed and unsuppressed groups in that they used CPAP at similar pressures and for similar amounts of time per day during the first 3 months (Table 2). Similar proportions of subjects reached the target pressure of 10 cm H2O and used CPAP for the minimum target treatment time of 4 hours per day.7,8
|
AHI and LVEF
From baseline to the 3-month follow-up polysomnogram, CPAP caused a greater reduction of the AHI in both the CPAP-CSAsuppressed (mean [95% confidence interval {CI}] 27.5 [30.8 to 24.2] events per hour of sleep) and the CPAP-CSAunsuppressed (12.1 [CI 16.8 to 7.3] events per hour of sleep) groups than in the control group (2.1 [CI 5.5 to 1.3] events per hour of sleep; Figure 2). The reduction in the AHI was significantly greater in the suppressed than in the unsuppressed group. The mean AHI at 3 months was 6 (95% CI 5 to 7) in the CPAP-CSAsuppressed group, 35 (95% CI 31 to 39) in the CPAP-CSAunsuppressed group, and 36 (95% CI 33 to 40) in the control group. The increase in mean nocturnal SaO2 was larger in the CPAP-CSAsuppressed group (2.1% [95% CI 1.2 to 3.0]) than in the control group (0.4% [95% CI 0.1 to 0.9], P<0.001). Changes in mean nocturnal SaO2 from baseline to 3 months did not differ significantly between the CPAP-CSAunsuppressed (1.0% [95% CI 0.6 to 1.4]) and control groups.
|
LVEF did not change significantly from baseline to 3 months in either the control group or the CSA-unsuppressed group (Figure 3). Change in LVEF in the CSA-unsuppressed group did not differ significantly from that in the control group. In contrast, LVEF increased significantly in the CPAP-CSAsuppressed group, and this increase was greater than in both the control group and the CPAP-CSAunsuppressed group. The change in LVEF correlated inversely with the change in AHI from baseline to 3 months (r=0.229, P=0.023) and with the absolute AHI at 3 months (r=0.238, P=0.018). In subjects from the control group whose AHI decreased to <15 at 3 months, no significant change was observed in LVEF. This change was less than the increase in LVEF in the CPAP-CSAsuppressed group but, probably owing to the small number of subjects in the control group (n=12), was not significant (0.3±3.3% versus 3.6±5.6%, P=0.205).
|
Transplant-Free Survival
Primary outcome data were obtained in all subjects, including dropouts. The mean follow-up after the sleep study at 3 months after enrollment was 23 months (range 0 to 61 months).
During follow-up, 26 primary events occurred (21 deaths and 5 heart transplantations; 23%) in the control group, 5 (5 deaths and no heart transplantations; 9%) in the CPAP-CSAsuppressed group, and 13 (9 deaths and 4 heart transplants; 30%) in the CPAP-CSAunsuppressed group. In the unadjusted model, transplant-free survival was significantly different between the 3 groups (P=0.016). Survival was significantly higher in the CPAP-CSAsuppressed group than in the control group (HR [95% CI] 0.371 [0.142 to 0.967]; Figure 4). In contrast, a nonsignificant trend existed toward reduced transplant-free survival in the CPAP-CSAunsuppressed group compared with the control group (unadjusted HR [95% CI] 1.463 [0.751 to 2.850]). None of the potential confounding variables considered (see Statistical Analysis above) conferred a 10% change in the HR of CPAP-CSAsuppressed and unsuppressed status, which indicates that no important confounding was present.22 Nevertheless, because subjects in the CPAP-CSAsuppressed group tended to be younger and to have a lower AHI than subjects from the control group, we derived a model adjusted for age and AHI at baseline. In this model, transplant-free survival was significantly different between the 3 groups (P=0.011). Compared with the control group, adjusted transplant-free survival remained significantly greater in the CPAP-CSAsuppressed group (HR 0.345 [95% CI 0.132 to 0.922], P=0.034) but tended to be lower in the CPAP-CSAunsuppressed group (HR 1.632 [95% CI 0.795 to 3.349], P=0.180). Neither age nor baseline AHI made any significant independent contribution to transplant-free survival (age: HR 0.993 [95% CI 0.963 to 1.024], P=0.650; AHI: HR 0.992 [95% CI 0.972 to 1.012], P=0.430). A nonsignificant trend for better transplant-free survival existed in subjects from the control group with a reduction in AHI to <15 than in control subjects whose AHI remained
15 after 3 months (HR 0.278 [95% CI 0.038 to 2.00], P=0.185).
|
| Discussion |
|---|
|
|
|---|
Uncertainty exists as to whether these effects were due to alleviation of CSA and its adverse actions3,5,8 or to the direct hemodynamic effects of CPAP, such as reductions in preload and afterload due to increased intrathoracic pressure.2326 The present analysis of CANPAP helps to resolve this issue: Compared with the control group, LVEF and transplant-free survival improved in the CPAP patients whose CSA was suppressed but not in those in whom CSA was not suppressed. Indeed, a nonsignificant trend to worse transplant-free survival existed in the CPAP-CSAunsuppressed group. Because CPAP pressure and hours of use did not differ between the CPAP-CSAsuppressed and unsuppressed groups, the direct preload- and afterload-reducing effects of CPAP are unlikely to explain improved LVEF and transplant-free survival in the suppressed group. Therefore, suppression of CSA and its adverse effects is more likely to account for the beneficial effects of CPAP on outcomes in the CPAP-CSAsuppressed group.
Interestingly, the survival curves of both the CPAP-CSAsuppressed group in the present secondary analysis of the CANPAP trial (Figure 4) and the CPAP group with CSA in the previous trial5 began to diverge from the control groups at
18 months after randomization. Moreover, in both trials, the overall relative reduction in risk of death and cardiac transplantation was similar in these groups at 64% and 67%, respectively.
In CANPAP, CPAP caused an overall reduction in AHI of 53%, which was less than the 65% to 70% reduction reported in previous single-center trials lasting at least 1 month.911 The reason for this attenuated effect remains uncertain. The 1- to 2-cm H2O lower mean CPAP achieved in the CANPAP trial compared with the first randomized trial10 does not appear to explain the variation of CPAP effects on CSA, because the pressures and hours of use did not differ between the CPAP-CSAsuppressed and unsuppressed groups. No differences existed between the control, CPAP-CSAsuppressed, and CPAP-CSAunsuppressed groups at baseline in sex, body mass index, race, severity and origin of heart failure, frequency of atrial fibrillation, and use of cardiac medications. Patients from the CPAP-CSAsuppressed group were younger, had less severe CSA, and had a slightly lower proportion of central events than subjects from the CPAP-CSAunsuppressed group. However, these differences at baseline were modest and, when controlled for in our statistical analyses, did not alter the effect of CPAP on LVEF or transplant-free survival.
Only 5% and 12% of the subjects who were not taking a ß-blocker at enrollment were started on one subsequently in the CPAP-CSAsuppressed and CPAP-CSAunsuppressed groups. These data do not support the possibility that compared with the control group, the better transplant-free survival of the CPAP-CSAsuppressed group was due to greater intensification of medical therapy during the trial.
The present analysis is subject to several limitations. First, it is a post hoc analysis in which stratification of the CPAP-treated patients was based on the results of a polysomnogram performed 3 months after randomization. Because the 2 CPAP-treated groups were not generated randomly, we cannot rule out the possibility that other unmeasured prognostic factors could explain differences in outcomes between the CPAP-CSAsuppressed and CPAP-CSAunsuppressed groups compared with the control group. One such factor could be LV filling pressure, because the CPAP-induced increase in intrathoracic pressure generally augments cardiac output acutely when applied to HF patients with elevated filling pressures but reduces it in those with low filling pressures.23 If patients in the CPAP-CSAunsuppressed group had low LV filling pressures, hemodynamic impairment by CPAP may have contributed to the
50% increased risk (P=0.260) of death or heart transplantation in the CPAP-CSAunsuppressed group compared with the control group. The lack of statistical significance for this comparison may reflect low study power rather than a lack of difference in transplant-free survival between groups. Second, because suppressed and unsuppressed status could not be ascertained until completion of polysomnography 3 months after randomization, events that occurred during the first 3 months could not be included; more deaths occurred in the patients randomized to CPAP than in the control group (5 versus 3). Third, the CPAP-CSAsuppressed group was younger, had a lower AHI, and had a slightly lower proportion of central events than the CPAP-CSAunsuppressed group. However, controlling for these factors did not affect the favorable HR for transplant-free survival in the CPAP-CSAsuppressed group. Fourth, because of the lack of a well-validated placebo for CPAP in treating CSA, the CANPAP trial was not placebo-controlled.
In summary, this stratified analysis of the CANPAP trial database suggests that early suppression of CSA by CPAP to an AHI below 15 per hour may improve both LVEF and transplant-free survival. The present data nevertheless do not support the use of CPAP in HF patients with predominantly CSA outside the setting of well-designed randomized trials. However, this possibility could be tested prospectively in 1 of 2 ways. The first approach would have to anticipate and control for the possibility of early harm from CPAP raised by the primary results of the CANPAP trial.8 We have shown previously that CPAP reduces AHI in HF patients with CSA within 1 month and that this precedes improvement in LVEF.10,11 In addition, in the CANPAP trial, no deaths or serious adverse effects occurred in HF patients randomized to CPAP within 1 month of its initiation. Therefore, patients with HF and CSA could be randomly assigned to CPAP or a control group and restudied after 1 month. If CPAP suppressed AHI (eg, to <15 events per hour as per the present analysis), then it could be continued; if not, then CPAP could be discontinued and the 2 groups followed up. A second approach would be to determine, in randomized trials, whether other forms of positive airway pressure, which might cause greater suppression of CSA than CPAP, are safe and improve long-term cardiovascular outcomes.6,27,28
| Acknowledgments |
|---|
The CANPAP trial was supported by a peer-reviewed grant from the Canadian Institutes of Health Research. In accordance with Canadian Institutes of Health Research policy, one third of the funding was provided by the Canadian Institutes of Health Research and two thirds by industry partners (Respironics Inc, ResMed Inc, and Tyco Healthcare Inc). Dr Bradley was supported by a Senior Scientist Award from the Canadian Institutes of Health Research, Dr Series by a National Scientist Award from the Fonds de la Recherche en Sante du Quebec, and Dr Floras by a Canada Research Chair in Integrative Cardiovascular Biology and a Career Investigator Award from the Heart and Stroke Foundation of Ontario.
Disclosures
All of the authors of the manuscript received grant support from Respironics, ResMed, and Tyco Healthcare for participation in the CANPAP trial. In addition, Dr Ferguson reports receiving lecture fees from GlaxoSmithKline, Respironics Inc, and VitalAire. Dr Pfeifer reports receiving grant support from Respironics. Dr Hanly reports having equity ownership in Tyco Healthcare.
| References |
|---|
|
|
|---|
2. Leung RS, Floras JS, Lorenzi-Filho G, Rankin F, Picton P, Bradley TD. Influence of Cheyne-Stokes respiration on cardiovascular oscillations in heart failure. Am J Respir Crit Care Med. 2003; 167: 15341539.
3. Naughton MT, Benard DC, Liu PP, Rutherford R, Rankin F, Bradley TD. Effects of nasal CPAP on sympathetic activity in patients with heart failure and central sleep apnea. Am J Respir Crit Care Med. 1995; 152: 473479.[Abstract]
4. Lanfranchi PA, Braghiroli A, Bosimini E, Mazzuero G, Colombo R, Donner CF, Giannuzzi P. Prognostic value of nocturnal Cheyne-Stokes respiration in chronic heart failure. Circulation. 1999; 99: 14351440.
5. Sin DD, Logan AG, Fitzgerald FS, Liu PP, Bradley TD. Effects of continuous positive airway pressure on cardiovascular outcomes in heart failure patients with and without Cheyne-Stokes respiration. Circulation. 2000; 102: 6166.
6. Arzt M, Bradley TD. Treatment of sleep apnea in heart failure. Am J Respir Crit Care Med. 2006; 173: 13001308.
7. Bradley TD, Logan AG, Floras JS. Rationale and design of the Canadian Continuous Positive Airway Pressure Trial for Congestive Heart Failure patients with Central Sleep Apnea: CANPAP. Can J Cardiol. 2001; 17: 677684.[Medline] [Order article via Infotrieve]
8. Bradley TD, Logan AG, Kimoff RJ, Series F, Morrison D, Ferguson K, Belenkie I, Pfeifer M, Fleetham J, Hanly P, Smilovitch M, Tomlinson G, Floras JS. Continuous positive airway pressure for central sleep apnea and heart failure. N Engl J Med. 2005; 353: 20252033.
9. Arzt M, Schulz M, Wensel R, Montalvan S, Blumberg FC, Riegger GA, Pfeifer M. Nocturnal continuous positive airway pressure improves ventilatory efficiency during exercise in patients with chronic heart failure. Chest. 2005; 127: 794802.[CrossRef][Medline] [Order article via Infotrieve]
10. Naughton MT, Liu PP, Bernard DC, Goldstein RS, Bradley TD. Treatment of congestive heart failure and Cheyne-Stokes respiration during sleep by continuous positive airway pressure. Am J Respir Crit Care Med. 1995; 151: 9297.[Abstract]
11. Tkacova R, Liu PP, Naughton MT, Bradley TD. Effect of continuous positive airway pressure on mitral regurgitant fraction and atrial natriuretic peptide in patients with heart failure. J Am Coll Cardiol. 1997; 30: 739745.[Abstract]
12. Davies RJ, Harrington KJ, Ormerod OJ, Stradling JR. Nasal continuous positive airway pressure in chronic heart failure with sleep-disordered breathing. Am Rev Respir Dis. 1993; 147: 630634.[Medline] [Order article via Infotrieve]
13. Rechtschaffen A, Kales A. A Manual of Standardized Terminology, Techniques and Scoring Systems for Sleep Stages of Human Subjects. Los Angeles, Calif: UCLA Brain Information Service/Brain Research Institute; 1968.
14. Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research: the Report of an American Academy of Sleep Medicine Task Force. Sleep. 1999; 22: 667689.[Medline] [Order article via Infotrieve]
15. Javaheri S, Parker TJ, Liming JD, Corbett WS, Nishiyama H, Wexler L, Roselle GA. Sleep apnea in 81 ambulatory male patients with stable heart failure: types and their prevalences, consequences, and presentations. Circulation. 1998; 97: 21542159.
16. Sin DD, Fitzgerald F, Parker JD, Newton G, Floras JS, Bradley TD. Risk factors for central and obstructive sleep apnea in 450 men and women with congestive heart failure. Am J Respir Crit Care Med. 1999; 160: 11011106.
17. Staats BA, Bonekat HW, Harris CD, Offord KP. Chest wall motion in sleep apnea. Am Rev Respir Dis. 1984; 130: 5963.[Medline] [Order article via Infotrieve]
18. Clark SA, Wilson CR, Satoh M, Pegelow D, Dempsey JA. Assessment of inspiratory flow limitation invasively and noninvasively during sleep. Am J Respir Crit Care Med. 1998; 158: 713722.
19. The SOLVD Investigators. Effect of enalapril on survival in patients with reduced left ventricular ejection fractions and congestive heart failure. N Engl J Med. 1991; 325: 293302.[Abstract]
20. Effect of metoprolol CR/XL in chronic heart failure: Metoprolol CR/XL Randomised Intervention Trial in Congestive Heart Failure (MERIT-HF). Lancet. 1999; 353: 20012007.[CrossRef][Medline] [Order article via Infotrieve]
21. R: A Language and Environment for Statistical Computing [computer program]. Version 2006. Vienna, Austria: R Foundation for Statistical Computing; 2006.
22. Maldonado G, Greenland S. Simulation study of confounder-selection strategies. Am J Epidemiol. 1993; 138: 923936.
23. Bradley TD, Holloway RM, McLaughlin PR, Ross BL, Walters J, Liu PP. Cardiac output response to continuous positive airway pressure in congestive heart failure. Am Rev Respir Dis. 1992; 145: 377382.[Medline] [Order article via Infotrieve]
24. Naughton MT, Rahman MA, Hara K, Floras JS, Bradley TD. Effect of continuous positive airway pressure on intrathoracic and left ventricular transmural pressures in patients with congestive heart failure. Circulation. 1995; 91: 17251731.
25. Sackner-Bernstein JD, Kowalski M, Fox M, Aaronson K. Short-term risk of death after treatment with nesiritide for decompensated heart failure: a pooled analysis of randomized controlled trials. JAMA. 2005; 293: 19001905.
26. Solin P, Bergin P, Richardson M, Kaye DM, Walters EH, Naughton MT. Influence of pulmonary capillary wedge pressure on central apnea in heart failure. Circulation. 1999; 99: 15741579.
27. Philippe C, Stoica-Herman M, Drouot X, Raffestin B, Escourrou P, Hittinger L, Michel PL, Rouault S, dOrtho MP. Compliance with and effectiveness of adaptive servoventilation versus continuous positive airway pressure in the treatment of Cheyne-Stokes respiration in heart failure over a six month period. Heart. 2006; 92: 337342.
28. Teschler H, Dohring J, Wang YM, Berthon-Jones M. Adaptive pressure support servo-ventilation: a novel treatment for Cheyne-Stokes respiration in heart failure. Am J Respir Crit Care Med. 2001; 164: 614619.
| Footnotes |
|---|
Related Article:
Circulation 2007 115: 3139.
This article has been cited by other articles:
![]() |
J S Floras Should sleep apnoea be a specific target of therapy in chronic heart failure? Heart, July 1, 2009; 95(13): 1041 - 1046. [Abstract] [Full Text] [PDF] |
||||
![]() |
D Yumino, H Wang, J S Floras, G E Newton, S Mak, P Ruttanaumpawan, J D Parker, and T D Bradley Relationship between sleep apnoea and mortality in patients with ischaemic heart failure Heart, May 1, 2009; 95(10): 819 - 824. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Luthje, B. Renner, R. Kessels, D. Vollmann, T. Raupach, B. Gerritse, S. Tasci, J. O. Schwab, M. Zabel, D. Zenker, et al. Cardiac resynchronization therapy and atrial overdrive pacing for the treatment of central sleep apnoea Eur J Heart Fail, March 1, 2009; 11(3): 273 - 280. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. D. Pinna, R. Maestri, A. Mortara, P. Johnson, D. Andrews, P. Ponikowski, T. Witkowski, E. Robbi, M. T. La Rovere, and P. Sleight Pathophysiological and clinical relevance of simplified monitoring of nocturnal breathing disorders in heart failure patients Eur J Heart Fail, March 1, 2009; 11(3): 264 - 272. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. K. Somers, D. P. White, R. Amin, W. T. Abraham, F. Costa, A. Culebras, S. Daniels, J. S. Floras, C. E. Hunt, L. J. Olson, et al. Sleep Apnea and Cardiovascular Disease: An American Heart Association/American College of Cardiology Foundation Scientific Statement From the American Heart Association Council for High Blood Pressure Research Professional Education Committee, Council on Clinical Cardiology, Stroke Council, and Council on Cardiovascular Nursing In Collaboration With the National Heart, Lung, and Blood Institute National Center on Sleep Disorders Research (National Institutes of Health) Circulation, September 2, 2008; 118(10): 1080 - 1111. [Full Text] [PDF] |
||||
![]() |
L. K. Brown Filling in the Gaps: The Role of Noninvasive Adaptive Servoventilation for Heart Failure-Related Central Sleep Apnea Chest, July 1, 2008; 134(1): 4 - 7. [Full Text] [PDF] |
||||
![]() |
M. Arzt, R. Wensel, S. Montalvan, T. Schichtl, S. Schroll, S. Budweiser, F. C. Blumberg, G. A. J. Riegger, and M. Pfeifer Effects of Dynamic Bilevel Positive Airway Pressure Support on Central Sleep Apnea in Men With Heart Failure Chest, July 1, 2008; 134(1): 61 - 66. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Simonds and M. R. Cowie Taboo: crossing the specialty barrier Eur. Respir. J., June 1, 2008; 31(6): 1153 - 1154. [Full Text] [PDF] |
||||
![]() |
O. Oldenburg, A. Schmidt, B. Lamp, T. Bitter, B. G. Muntean, C. Langer, and D. Horstkotte Adaptive servoventilation improves cardiac function in patients with chronic heart failure and Cheyne-Stokes respiration Eur J Heart Fail, June 1, 2008; 10(6): 581 - 586. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Horner and T. D. Bradley Update in Sleep and Control of Ventilation 2007 Am. J. Respir. Crit. Care Med., May 1, 2008; 177(9): 947 - 951. [Full Text] [PDF] |
||||
![]() |
B. Phillips Improving Access to Diagnosis and Treatment of Sleep-Disordered Breathing Chest, November 1, 2007; 132(5): 1418 - 1420. [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2007 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |