Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2006;114:1232-1233
doi: 10.1161/CIRCULATIONAHA.106.647800
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Faris, O. P.
Right arrow Articles by Shein, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Faris, O. P.
Right arrow Articles by Shein, M.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*MRI Scans
*Pacemakers and Implantable Defibrillators
Related Collections
Right arrow Other Ethics and Policy
Right arrow Pacemaker
Right arrow Ablation/ICD/surgery
Right arrow CT and MRI
Right arrow Computerized tomography and Magnetic Resonance Imaging

(Circulation. 2006;114:1232-1233.)
© 2006 American Heart Association, Inc.


Editorial

Food and Drug Administration Perspective

Magnetic Resonance Imaging of Pacemaker and Implantable Cardioverter-Defibrillator Patients

Owen P. Faris, PhD; Mitchell Shein, MS

From the Division of Cardiovascular Devices, Center for Devices and Radiological Health, Food and Drug Administration, Rockville, Md.

Correspondence to Mitchell J. Shein, MS, FDA Expert, Cardiac Pacing, Division of Cardiovascular Devices, Center for Devices and Radiological Health, Food and Drug Administration, 9200 Corporate Boulevard, Rockville, MD 20850. E-mail mitchell.shein{at}fda.hhs.gov


Key Words: Editorials • defibrillation • imaging • magnetic resonance imaging • pacemakers • pacing

In April 2005, the US Food and Drug Administration (FDA) commented on the current research regarding the use of magnetic resonance imaging (MRI) on patients with a pacemaker or implantable cardioverter-defibrillator (ICD).1 Pacemaker and ICD labeling currently cautions physicians against the use of MRI, and MRI manufacturers contraindicate MRI for pacemaker and ICD patients. As discussed in our previous editorial, several studies have demonstrated the potential for MRI to be performed in pacemaker or ICD patients without serious clinical consequence.2–4 Studies presented by Sommer et al5 and Nazarian et al6 in this issue of Circulation offer further promising evidence in this regard. As with the previous studies, however, the authors acknowledge a multitude of limitations that prevent broad applicability of the results. Furthermore, one of these studies was not entirely free from concerning outcomes with the potential for serious clinical events. We view these results as consistent with our previous message that, on a case-by-case basis, the diagnostic benefit from MRI outweighs the presumed risks for some pacemaker and ICD patients. However, the FDA remains firm in its belief that those risks have not yet been characterized and mitigated sufficiently to justify the routine use of MRI in those populations. The FDA continues to believe that a more thorough evaluation of concerns related to heating, arrhythmogenesis, and proper device function during and after MRI, as well as validated MR protocols, should be available before approval for labeling that endorses the use of MRI for pacemaker or ICD patients is obtained.

Articles pp 1277 and 1285

The studies presented by Sommer et al5 and Nazarian et al6 in this issue involved a total of 113 pacemaker and 24 ICD patients who underwent 183 MR exams for an urgent or MR-specific clinical need. The Sommer et al study was limited to patients with a pacemaker from a single manufacturer; the Nazarian et al study enrolled only patients whose pacemaker or ICD model had already been evaluated through in vitro and in vivo testing by the authors. Each study was restricted to a single MR system manufacturer and model. Meaningful exclusion criteria included pacemaker dependency and the need for a thoracic MR scan for the Sommer et al study and the presence of an epicardial, nonfixated, or abandoned lead for the Nazarian et al study. It is important to note that the MR scanning parameters allowed for clinically relevant scans that were moderately rigorous in terms of specific absorption rate. Both studies demonstrated the encouraging result of no observed adverse clinical events. Furthermore, Nazarian et al comment that the MR examination resulted in a clinical diagnosis in nearly all subjects.

Although the ability to arrive at clinical diagnoses is a positive note, other outcomes, particularly from the Sommer et al study, have implications that are of concern. Seven of the 115 MR exams in the Sommer et al study resulted in pacemaker reset and a reversion to the factory VVI settings, and in 21 of the 47 devices evaluated, the reed switch did not close to activate the magnet mode for the device. Although not exhibited in this study, these 2 malfunctions in combination could have serious consequences, particularly for a pacemaker-dependent patient, because MR-induced interference could be sensed by the pacemaker, resulting in inhibition of therapy. This observation is consistent with other studies that have demonstrated that MRI may adversely affect the function or programmability of certain ICDs or pacemakers.7 To date, published studies have not thoroughly explored the extent to which the risk for device malfunction is dependent on scan parameters, MR system, and patient and device position within the MR system or the device design.

Results of the Sommer et al5 study also indicate the presence of tissue damage as assessed by small but statistically significant changes in mean pacing threshold and lead impedance across patients, and clinically meaningful changes in pacing threshold and troponin I for some individual patients. The Nazarian et al6 study did not demonstrate any statistically significant changes in the means for sensing amplitude, lead impedance, or pacing threshold. Of note, Nazarian et al did not present data regarding individual patient outcomes. The Sommer et al results are consistent with previous studies that indicate that the potential for MR-induced thermal injury in pacemaker and ICD patients exists and that methods for consistently avoiding such heating have not been validated.8 In the study conducted by Martin et al,3 for example, 9.4% of the leads studied exhibited a "significant" change in pacing threshold; most of these changes were threshold increases, likely indicating thermal injury. Of particular concern is the potential cumulative effect for patients who undergo several MRI procedures.

It is encouraging to note that neither study presented in this issue reports observed arrhythmia induction from MRI. However, as acknowledged by Sommer et al,5 the potential for such events exists. This is consistent with the FDA’s perspective that, although arrhythmia induction in pacemaker or ICD patients from MRI is likely a rare event, the consequences could be catastrophic. This is of particular concern for ICD patients who may be more susceptible to arrhythmias and would likely have their ICD disabled during the MRI procedure. Both studies presented in this issue followed rigorous patient monitoring protocols to avoid such an event. However, the FDA remains concerned that the extent to which arrhythmogenic risk is dependent on scan parameters, MR system, patient and device position, and device design has not been adequately characterized. Furthermore, protocols such as those presented in this issue, while worthy of consideration, have not been sufficiently validated to support routine clinical use.

Given the range of available MR systems and scan conditions, pacemaker and ICD systems and leads, and the range of potential patient conditions, the authors of both studies presented in this issue acknowledge the limitations that prevent extending these encouraging results to recommendations for routine use of MRI in pacemaker and ICD patients. Of note, given the potential risks that an MR procedure presents, both studies were limited to patients with a substantial clinical need for MRI. The FDA concurs with the authors that, for some patients, the risks presented by MRI under specific, characterized scanning and monitoring conditions may be acceptable given the diagnostic benefit of this powerful imaging modality.

The FDA continues to believe that extending MRI use to the general pacemaker and ICD patient population through removal or modification of device warnings and contraindications will require thorough characterization of the array of safety concerns related to heating, arrhythmogenesis, and proper device function and validation of the measures taken to mitigate these concerns. Although many of these concerns are best addressed through bench and animal studies, prospectively designed and adequately powered clinical trials will likely be necessary to confirm the results from preclinical testing. The FDA is committed to working with pacemaker and ICD manufacturers to pursue these studies to seek labeling modifications for their devices.


*    Acknowledgments
 
Disclosures

None.


*    Footnotes
 
The opinions expressed in this article are not necessarily those of the editors or of the American Heart Association.

The views and opinions expressed are those of the authors and do not necessarily reflect those of the US Food and Drug Administration or the US Department of Health and Human Services.


*    References
up arrowTop
*References
 
1. Faris OP, Shein MJ. Government viewpoint: US Food and Drug Administration: pacemakers, ICDs, and MRI. Pacing Clin Electrophysiol. 2005; 28: 268–269.[CrossRef][Medline] [Order article via Infotrieve]

2. Gimbel JR, Kanal E, Schwartz KM, Wilkoff BL. Outcome of magnetic resonance imaging (MRI) in selected patients with implantable cardioverter defibrillators (ICDs). Pacing Clin Electrophysiol. 2005; 28: 268–269.[CrossRef][Medline] [Order article via Infotrieve]

3. Martin ET, Coman JA, Shellock FG, Pulling CC, Fair R, Jenkins K. Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla. J Am Coll Cardiol. 2004; 43: 1315–1324.[Abstract/Free Full Text]

4. Roguin A, Zviman MM, Meininger GR, Rodrigues ER, Dickfeld TM, Bluemke DA, Lardo A, Berger RD, Calkins H, Halperin HR. Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe in vitro and in vivo assessment of safety and function at 1.5 T. Circulation. 2004; 110: 475–482.[Abstract/Free Full Text]

5. Sommer T, Naehle CP, Yang A, Zeijlemaker V, Hackenbroch M, Schmiedel A, Meyer C, Strach K, Skowasch D, Vahlhaus C, Litt H, Schild H. Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 T in the presence of cardiac pacemakers in non–pacemaker-dependent patients: a prospective study with 115 examinations. Circulation. 2006; 114: 1285–1292.[Abstract/Free Full Text]

6. Nazarian S, Roguin A, Zviman MM, Lardo AC, Dickfeld TL, Calkins H, Weiss RG, Berger RD, Bluemke DA, Halperin HR. Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable cardioverter-defibrillators at 1.5 Tesla. Circulation. 2006; 114: 1277–1284.[Abstract/Free Full Text]

7. Fiek M, Remp T, Reithmann C, Steinbeck G. Complete loss of ICD programmability after magnetic resonance imaging. Pacing Clin Electrophysiol. 2004; 27: 1002–1004.[CrossRef][Medline] [Order article via Infotrieve]

8. Sommer T, Vahlhaus C, Lauck G, von Smekal A, Reinke M, Hofer U, Block W, Traber F, Schneider C, Gieseke J, Jung W, Schild H. MR imaging and cardiac pacemakers: in vitro evaluation and in vivo studies in 51 patients at 0.5 T. Radiology. 2000; 215: 869–879.[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
A. Roguin
Magnetic resonance imaging in patients with implantable cardioverter-defibrillators and pacemakers.
J. Am. Coll. Cardiol., August 4, 2009; 54(6): 556 - 557.
[Full Text] [PDF]


Home page
EuropaceHome page
E. M. Aliot, W. G. Stevenson, J. M. Almendral-Garrote, F. Bogun, C. H. Calkins, E. Delacretaz, P. D. Bella, G. Hindricks, P. Jais, M. E. Josephson, et al.
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias: Developed in a partnership with the European Heart Rhythm Association (EHRA), a Registered Branch of the European Society of Cardiology (ESC), and the Heart Rhythm Society (HRS); in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA)
Europace, June 1, 2009; 11(6): 771 - 817.
[Full Text] [PDF]


Home page
RadiologyHome page
C. P. Naehle, C. Meyer, D. Thomas, S. Remerie, C. Krautmacher, H. Litt, R. Luechinger, R. Fimmers, H. Schild, and T. Sommer
Safety of Brain 3-T MR Imaging with Transmit-Receive Head Coil in Patients with Cardiac Pacemakers: Pilot Prospective Study with 51 Examinations
Radiology, December 1, 2008; 249(3): 991 - 1001.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
T Dill
Contraindications to magnetic resonance imaging
Heart, July 1, 2008; 94(7): 943 - 948.
[Full Text] [PDF]


Home page
EuropaceHome page
A. Roguin, J. Schwitter, C. Vahlhaus, M. Lombardi, J. Brugada, P. Vardas, A. Auricchio, S. Priori, and T. Sommer
Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices
Europace, March 1, 2008; 10(3): 336 - 346.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
T. Dickfeld, P. Lei, V. Dilsizian, J. Jeudy, J. Dong, A. Voudouris, R. Peters, M. Saba, R. Shekhar, and S. Shorofsky
Integration of three-dimensional scar maps for ventricular tachycardia ablation with positron emission tomography-computed tomography.
J. Am. Coll. Cardiol. Img., January 1, 2008; 1(1): 73 - 82.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
G. N. Levine, A. S. Gomes, A. E. Arai, D. A. Bluemke, S. D. Flamm, E. Kanal, W. J. Manning, E. T. Martin, J. M. Smith, N. Wilke, et al.
Safety of Magnetic Resonance Imaging in Patients With Cardiovascular Devices: An American Heart Association Scientific Statement From the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: Endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance
Circulation, December 11, 2007; 116(24): 2878 - 2891.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Faris, O. P.
Right arrow Articles by Shein, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Faris, O. P.
Right arrow Articles by Shein, M.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*MRI Scans
*Pacemakers and Implantable Defibrillators
Related Collections
Right arrow Other Ethics and Policy
Right arrow Pacemaker
Right arrow Ablation/ICD/surgery
Right arrow CT and MRI
Right arrow Computerized tomography and Magnetic Resonance Imaging