Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2006;113:414-419
doi: 10.1161/CIRCULATIONAHA.105.563403
CLINICAL PERSPECTIVE
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hong, M.-K.
Right arrow Articles by Park, S.-J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hong, M.-K.
Right arrow Articles by Park, S.-J.
Related Collections
Right arrow Catheter-based coronary interventions: stents
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC

(Circulation. 2006;113:414-419.)
© 2006 American Heart Association, Inc.


Interventional Cardiology

Late Stent Malapposition After Drug-Eluting Stent Implantation

An Intravascular Ultrasound Analysis With Long-Term Follow-Up

Myeong-Ki Hong, MD, PhD; Gary S. Mintz, MD; Cheol Whan Lee, MD, PhD; Duk-Woo Park, MD; Kyoung-Min Park, MD; Bong-Ki Lee, MD; Young-Hak Kim, MD, PhD; Jong-Min Song, MD, PhD; Ki-Hoon Han, MD; Duk-Hyun Kang, MD, PhD; Sang-Sig Cheong, MD, PhD; Jae-Kwan Song, MD, PhD; Jae-Joong Kim, MD, PhD; Seong-Wook Park, MD, PhD; Seung-Jung Park, MD, PhD

From the Department of Medicine, University of Ulsan College of Medicine, Asan Medical Center, Seoul (M.-K.H., C.W.L., D.-W.P., K.-M.P., B.-K.L., Y.-H.K., J.-M.S., K.-H.H., D.-H.K., J.-K.S., J.-J.K., S.-W.P., S.-J.P.) and GangNeung (S.-S.C.), Korea, and Cardiovascular Research Foundation (G.S.M.), New York, NY.

Correspondence to Seung-Jung Park, MD, PhD, Departments of Medicine, University of Ulsan College of Medicine, Cardiac Center, Asan Medical Center, 388-1 Poongnap-dong, Songpa-gu, Seoul, 138-736, Korea. E-mail sjpark{at}amc.seoul.kr

Received May 19, 2005; revision received October 7, 2005; accepted November 4, 2005.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background— Late stent malapposition (LSM) after drug-eluting stent (DES) implantation has not been evaluated sufficiently in real-world practice.

Methods and Results— We evaluated the incidence, mechanisms, predictors, and long-term prognosis of LSM after DES implantation in 557 patients (705 native lesions; sirolimus-eluting stent in 538 lesions and paclitaxel-eluting stent in 167 lesions) in whom intravascular ultrasound was performed at index and 6-month follow-up. LSM occurred in 82 patients with 85 lesions (12.1% overall, 95% CI 9.7% to 14.5%, 71 lesions (13.2%) in sirolimus-eluting stents and 14 lesions [8.4%] in paclitaxel-eluting stents, P=0.12]; the incidence was 25.0% (4/16) after directional coronary atherectomy before stenting, 27.5% (14/51) in chronic total occlusion lesions, and 31.8% (7/22) after primary stenting in acute myocardial infarction (P=0.13, P<0.001, and P=0.001, respectively, versus elective stenting with conventional balloon predilation, 9.7% [60/616]). There was an increase of external elastic membrane area (from 17.1±3.6 to 21.4±4.8 mm2, P<0.001) that was greater than the increase in plaque area (from 9.3±2.5 to 10.5±2.7 mm2, P<0.001). Independent predictors of LSM were total stent length, primary stenting in acute myocardial infarction, and chronic total occlusion lesions. Except for 1 death in the non-LSM group, there were no major adverse cardiac events in either LSM or non-LSM patients during a mean 10-month follow-up after detection of LSM.

Conclusions— LSM occurs in 12% of cases after DES implantation. The predictors of LSM are total stent length, primary stenting in acute myocardial infarction, and chronic total occlusion lesions. LSM after DES implantation was not associated with any major adverse cardiac events during a subsequent 10-month (mean) follow-up.


Key Words: ultrasonics • stents • coronary disease


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Several studies have reported late stent malapposition (LSM) in 4% to 5% of patients after bare-metal stent (BMS) implantation.1–3 Although drug-eluting stents (DESs) dramatically reduce in-stent restenosis, there may be an increased frequency of LSM on follow-up intravascular ultrasound (IVUS) examination.4,5 The primary aims of the present study were (1) to determine the incidence of LSM after DES implantation in a large, real-world practice of coronary intervention that included complex lesion subsets and (2) to evaluate the clinical impact of LSM on long-term prognosis (major adverse cardiac events [MACE]). Secondarily, we also sought to identify the mechanisms and the clinical, angiographic, and IVUS predictors of LSM in these patients.

Clinical Perspective p 419


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Study Population
From the Asan Medical Center clinical and core IVUS laboratory database, we identified 557 patients with 705 native lesions who underwent DES implantation into de novo lesions with IVUS imaging at index and 6-month follow-up (mean interval 6.1±2.1 months). Sirolimus-eluting stents (Cypher stent, Cordis/Johnson and Johnson) and paclitaxel-eluting stents (TAXUS stent, Boston Scientific Corp) were used in 538 and 167 lesions, respectively. All patients undergoing DES implantation at Asan Medical Center were requested to have a 6-month follow-up angiogram; in addition, IVUS was performed at 6-month follow-up in patients in whom IVUS had been previously performed at baseline.

Primary stenting of the infarct-related culprit lesion in acute myocardial infarction (MI) patients was performed within 12 hours after symptom onset. Chronic total occlusion (CTO) lesions were defined by the absence of antegrade flow or only minimal flow of contrast distal to the occlusion (Thrombolysis In Myocardial Infarction [TIMI] flow grade 0 or 1)6; the duration of the total occlusion as estimated by clinical information, sequential angiographic information, or both was >1 month in all CTO patients.

All patients received a 300-mg loading dose of clopidogrel followed by clopidogrel 75 mg/d for 6 months and aspirin 200 mg/d indefinitely. Cilostazol 200 mg/d for 3 to 6 months after DES implantation was additionally prescribed in 16 patients (20%) with LSM and 74 (16%) without LSM (P=0.5).7 Fifty-one LSM patients (62%) and 283 non-LSM patients (60%; P=0.8) continued to receive clopidogrel 75 mg/d for 5.4±4.1 and 5.1±4.2 months, respectively (P=0.5), beyond the 6-month angiogram.

Definition of MACE and Clinical Follow-Up
Long-term (ie, beyond 6-month) clinical follow-up data were obtained from outpatient record reviews or telephone interviews. Death was classified as cardiac versus noncardiac. MI was defined as an elevation of the MB fraction of creatinine kinase to a value 3 times the upper limit of the normal range. Target-lesion revascularization was repeat percutaneous or surgical intervention of the stented lesion. MACE was defined as death of cardiac origin, MI, and target-lesion revascularization. All patients were followed up for a minimum of 4.0 months (range 4.0 to 20.3 months) after the 6-month follow-up angiogram and IVUS, except for 1 sudden death in a patient without LSM.

IVUS Imaging and Analysis
Poststenting and 6-month follow-up IVUS imaging were performed after intracoronary administration of 0.2 mg of nitroglycerin with a motorized transducer pullback system (0.5 mm/s) and a commercial scanner (SCIMED) that consisted of a rotating 30- or 40-MHz transducer within a 3.2F or 2.6F imaging sheath.

LSM was defined as separation of at least 1 stent strut from the intimal surface of the arterial wall that was not overlapping a side branch, was not present immediately after stent implantation, and had evidence of blood flow (speckling) behind the strut.1 Postprocedural incomplete stent apposition was classified into 2 groups: (1) resolved, incomplete apposition present after the procedure but no longer present at 6-month follow-up and (2) persistent, incomplete apposition present both after the procedure and at 6-month follow-up.5

Qualitative analysis was performed as follows. First, we reviewed all 705 follow-up IVUS tapes to identify cases of stent malapposition. Second, index (poststenting) and follow-up IVUS tapes were reviewed side-by-side to discriminate cases in which incomplete stent malapposition existed immediately after stent implantation. This included independent review of index and follow-up IVUS studies by 2 of the authors (M.-K.H. and Y.-H.K.).

Using computerized planimetry, we performed quantitative IVUS analysis at (1) LSM sections, (2) postprocedural incomplete stent apposition sections, (3) stented segments with complete late apposition, and (4) reference segments. Quantitative measurements included external elastic membrane (EEM), lumen, and stent cross-sectional areas (CSA) at stented and reference segments; EEM, stent, plaque and media (P&M), intrastent lumen, intimal hyperplasia, and LSM CSA at LSM sections; and incomplete stent apposition CSA at postprocedural incomplete stent apposition sections.8 LSM CSA was measured every 1 mm within LSM sections; LSM volumes were calculated with Simpson’s rule.

Quantitative Coronary Angiographic Analysis
With the guiding catheter for magnification-calibration and an online system (ANCOR version 2.0, Siemens), minimal luminal diameter (MLD) of the lesion and diameters of the reference segments were measured before and after stenting and at 6-month follow-up.

Statistical Analysis
Statistical analysis was performed with the SPSS software program (SPSS Inc). Categorical data are presented as frequencies and compared with {chi}2 statistics or Fisher’s exact test. Continuous variables are presented as mean±SD and compared with unpaired or paired Student t test or Mann-Whitney U test and correlation coefficients. Event-free survival was analyzed with the Kaplan-Meier method, and the corresponding probability value was obtained from log-rank test. A probability value <0.05 was considered statistically significant.

A subgroup analysis of electively stented lesions after only conventional balloon predilation was also performed because this represents the typical strategy for the majority of lesions undergoing percutaneous coronary intervention. These lesions were not treated by unusual coronary interventions (ie, directional coronary atherectomy [DCA] before stenting) or in unusual clinical situations (acute MI or CTO lesions). This analysis was similar to our previous BMS study.2 Sirolimus- versus paclitaxel-eluting stents were also compared.

Multiple stepwise logistic regression analysis was performed to assess independent predictors for LSM. To identify the independent predictors of LSM, the clinical, angiographic, and IVUS variables were entered into per-lesion models. To analyze the impact of LSM on long-term prognosis, only 1 lesion per patient was included: that with LSM for patients who had LSM and that with the most unfavorable characteristics for occurrence of adverse events for patients without LSM.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
LSM was documented in 85 lesions in 82 patients (12.1% overall, 95% CI 9.7% to 14.5%): 71 (13.2%, 95% CI 10.3% to 16.1%) of lesions treated with sirolimus-eluting stents and 14 (8.4%, 95% CI 4.2% to 12.6%) of lesions treated with paclitaxel-eluting stents (P=0.12). Baseline clinical and angiographic characteristics comparing LSM and non-LSM are shown in Tables 1 and 2Down, respectively. Preintervention quantitative coronary angiography (QCA) MLD was significantly smaller and total stent length was significantly longer in the LSM group than in the non-LSM group. Compared with the non-LSM group, there was more primary MI stenting and treatment of CTO lesions in the LSM group and a tendency for more prestenting DCA in the LSM group.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Baseline Clinical Characteristics


View this table:
[in this window]
[in a new window]
 
TABLE 2. Baseline Angiographic Characteristics and Poststenting IVUS Measurements

After baseline characteristics (listed in Tables 1 and 2Up) were adjusted among subgroups, compared with the frequency of LSM in lesions that were treated with conventional balloon predilation and elective stenting (9.7%, 95% CI 7.4% to 12.1%, 60/616), LSM occurred in 7 (31.8%, 95% CI 12.4% to 51.3%) of 22 lesions that underwent primary stenting in acute MI (P=0.001), in 14 (27.5%, 95% CI 15.2% to 39.7%) of 51 CTO lesions (P<0.001), and in 4 (25.0%, 95% CI 10.3% to 46.2%) of 16 lesions treated with prestenting DCA (P=0.13).

Poststenting QCA and IVUS findings comparing lesions with and without LSM are also shown in Table 2. At follow-up, QCA MLD was larger in the LSM group (2.7±0.5 versus 2.5±0.7 mm, P=0.025).

In the subgroup of elective stenting after conventional balloon predilation (n=616), angiographic findings and poststenting IVUS measurements comparing lesions with and without LSM are shown in Table 3. Preintervention QCA MLD was also significantly smaller and total stent length was significantly longer in the LSM group than in the non-LSM group.


View this table:
[in this window]
[in a new window]
 
TABLE 3. Baseline Angiographic Characteristics and Poststenting IVUS Measurements in the Subgroup of Lesions With Stenting After Conventional Balloon Predilation

The location of LSM was at the edge (within 5 mm from stent margin) in 14 lesions (16%; 12 proximal and 2 distal; 12 sirolimus-eluting stents and 2 paclitaxel-eluting stents) and within the body of the stent in 71 lesions (84%; 59 sirolimus-eluting stents and 12 paclitaxel-eluting stents). Poststenting and follow-up IVUS measurements at the LSM segment are shown in Table 4. The maximum CSA and arc of LSM measured 3.0±1.9 mm2 and 130±35°, respectively. The maximum number of stent struts and maximum distance between stent struts and intima/lumen border were 2.9±1.2 and 1.3±0.4 mm, respectively. There was an increase of EEM CSA (from 17.1±3.6 mm2 after implantation to 21.4±4.8 mm2 at follow-up, P<0.001) and an increase of P&M CSA (from 9.3±2.5 mm2 after implantation to 10.5±2.7 mm2 at follow-up, P<0.001). The increase in EEM was greater than the increase in P&M (P<0.001). LSM CSA correlated directly with the increase in EEM CSA (r=0.882, P<0.001).


View this table:
[in this window]
[in a new window]
 
TABLE 4. Poststenting and Follow-Up IVUS Measurements at the LSM Segment in the Total Cohort of 85 Patients

Predictors of LSM
Stepwise multiple logistic regression analysis was performed to determine independent predictors of LSM. The following variables were tested (all with P<0.2 in univariate analysis): lesion location, types of DES (sirolimus- versus paclitaxel-eluting stent), total stent length, preintervention QCA MLD, primary stenting in acute MI, DCA before stenting, CTO lesions, and proximal reference-segment EEM CSA. Independent predictors of LSM were total stent length (P=0.001, OR=1.021, 95% CI=1.009 to 1.034), primary stenting in acute MI (P=0.003, OR=4.263, 95% CI=1.664 to 10.918), and CTO lesions (P=0.007, OR=2.594, 95% CI=1.299 to 5.183). In the subgroup of elective stenting after conventional balloon predilation, the only independent predictor of LSM was total stent length (P=0.001, OR=1.025, 95% CI=1.011 to 1.039).

Comparison Between Sirolimus- and Paclitaxel-Eluting Stents
Baseline angiographic characteristics and IVUS measurements between sirolimus- versus paclitaxel-eluting stents are shown in Table 5; there were no significant differences. At follow-up, there was a tendency for a smaller increase in EEM CSA (P=0.19) and a statistically smaller increase in P&M CSA and intimal hyperplasia CSA in sirolimus-eluting stents (P=0.016 and 0.029, respectively; Table 6).


View this table:
[in this window]
[in a new window]
 
TABLE 5. Baseline Angiographic Characteristics and Poststenting IVUS Measurements Comparing Sirolimus- and Paclitaxel-Eluting Stents With LSM


View this table:
[in this window]
[in a new window]
 
TABLE 6. Comparison of IVUS LSM Segment Measurements Between Sirolimus- and Paclitaxel-Eluting Stents

Postprocedural Incomplete Stent Apposition
Postprocedure incomplete stent apposition was observed in 51 lesions (7.2%; 47 sirolimus-eluting stents and 4 paclitaxel-eluting stents; 50 proximal stent edge and 1 distal stent edge). Incomplete stent apposition persisted in all 51 lesions at 6-month follow-up. Poststenting and follow-up IVUS measurements at this segment are shown in Table 7. In these lesions, there were consistent increases in both EEM and P&M CSA, although the size of the incomplete apposition segment did not change. There were no MACEs (including target-lesion revascularization) in these patients with postprocedure incomplete stent apposition who had an average follow-up of 16.6±4.0 months after DES implantation.


View this table:
[in this window]
[in a new window]
 
TABLE 7. Poststenting and Follow-Up IVUS Measurements in Patients With Incomplete Stent Apposition of the Stented Segment at the Time of Stent Implantation

Long-Term Follow-Up
At 6 months, target-lesion revascularization was necessary in 20 patients with 22 lesions in the non-LSM group but in none of the LSM patients (P=0.095); 5 non-LSM patients also required revascularization of a nontarget lesion. Therefore, 542 patients with 683 lesions were eligible for long-term (beyond 6 months) clinical follow-up. The mean duration of long-term clinical follow-up after the 6-month angiogram was 10.9±4.4 and 10.1±3.9 months in the LSM and non-LSM groups, respectively (P=0.1). One patient in the non-LSM group died suddenly 2.6 months after the 6-month follow-up angiogram. Except for this 1 death in a non-LSM patient, there was no other MACE beyond 6 months in either group. There was no significant difference in event-free survival rate between the 2 groups (log-rank probability value=0.67).


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
In this retrospective analysis of 705 native lesions treated with DES implantation and studied with postimplantation and follow-up IVUS, we found 85 lesions (12.1%) with LSM at 6-month follow-up, in 13.2% of sirolimus-eluting stents and 8.4% of paclitaxel-eluting stents. Total stent length, primary stenting in acute MI, and CTO lesions were independent predictors of LSM. Long-term clinical follow-up was available for a mean of 10.2 months after detection of LSM; compared with non-LSM patients, patients with LSM showed similarly favorable outcomes. In particular, LSM was not associated with any subsequent events.

A higher incidence of stent malapposition at follow-up was reported in the sirolimus-eluting stent group than in the BMS group in the RAVEL trial.4 However, the true incidence of LSM could not be determined because postprocedural IVUS was not performed.4 A recent IVUS substudy of the TAXUS II trial reported a statistically similar incidence of LSM between paclitaxel-eluting stents (8.0% to 9.5%) and BMS (5.4%).5 In the TAXUS IV IVUS substudy, however, there was a lower incidence of LSM than in TAXUS II in both groups (1.1% and 2.2%, respectively).9 Because complex lesions that included very long lesions, CTOs, and thrombotic lesions were excluded in the previous randomized trials, the actual incidence of LSM in a real-world daily practice could not be determined. In the present study of real-world patients, the actual incidence of LSM at a 6-month follow-up after DES implantation appeared to higher than in the randomized trials and appeared to be higher than in BMS-treated patients.

Mechanism of LSM
In the present study, the main cause of LSM was an increase in EEM out of proportion to the increase in peristent P&M as shown in Table 4, the increase in EEM was greater than the modest increase in P&M CSA (Table 4), and LSM CSA correlated directly with the increase in EEM CSA. These findings are similar to previous studies of LSM after BMS implantation,1,2,10 although the magnitude of the vascular response appears to be different. However, these findings are somewhat (but not entirely) different from those reported by Tanabe et al.5 Tanabe et al also reported that the cause of LSM was a significant increase in EEM CSA, but they did not find a difference between P&M CSA at follow-up compared with postimplantation.5 The present study included 71 sirolimus-eluting and 14 paclitaxel-eluting stents with LSM; the study by Tanabe et al only included paclitaxel-eluting stents. Furthermore, 11 of 19 LSM segments in the study by Tanabe et al were of the moderate-release preparation. However, most importantly, both studies showed that the main cause of LSM was positive remodeling (an increase in EEM), not a decrease in plaque mass. When the sirolimus- and paclitaxel-eluting stents were compared, sirolimus-eluting stents with LSM had a smaller increase in EEM and P&M CSA, which suggests that the mechanism of LSM in sirolimus-eluting stents was a greater suppression of peristent neointimal hyperplasia (supported by the smaller amount of intrastent neointimal hyperplasia), whereas the mechanism of LSM in paclitaxel-eluting stents was a greater amount of peristent positive remodeling (Table 6).

Predictors of LSM
Our previous study showed that primary stenting in acute MI and prestent DCA were independent predictors of LSM after BMS implantation.2 The IVUS substudy of TAXUS II reported that predictors of LSM after paclitaxel-eluting stent implantation were lesion length, unstable angina, and absence of diabetes.5 In the present study, independent predictors of LSM after DES implantation were total stent length, primary stenting in acute MI, and CTO lesions. Because very long lesions are typically treated by multiple overlapping DESs, total stent length in the present study and lesion length in the previous study5 shared similar concepts. The incidence of LSM after primary stenting in acute MI was 11.5% after BMS implantation in the previous study2 and 31.8% after DES implantation in the present study. Compared with elective DES implantation, a higher incidence of LSM in acute MI patients might be explained by abluminal thrombus resolution2 after primary stenting in acute MI patients. TAXUS II did not include acute MI patients, but thrombus dissolution may have also been important in unstable angina. The incidence of LSM in CTO lesions was 27.5% in the present study. Subintimal passage of the guidewire, creation of a false lumen, or stenting of the false lumen may result in injury to the adventitial layer during DES implantation of CTO lesions, contributing to LSM. Prestent DCA was an independent predictor of LSM in BMS implantation.2,3 Although pre-DES DCA did not achieve statistical significance because of the small number of prestent DCA lesions, the incidence of LSM was 25.0% in the present study. Therefore, when a DES is implanted after DCA, a positive synergistic effect of LSM with DCA and DES on LSM should be expected. In the univariate statistical analysis of the present study, preintervention QCA MLD was significantly smaller in the LSM group than in the non-LSM group. This finding was consistent with our previous report of predictors of LSM after BMS implantation.2 The common denominator may be vessel injury. Larger balloons or higher pressures may be necessary to optimize results after stenting of lesions with smaller or tighter MLDs.2

Postprocedural Incomplete Stent Apposition
The incidence of postprocedural incomplete stent apposition after DES was 7.2% in the present study, similar to the previous TAXUS II IVUS substudy.5 However, unlike the present study, the TAXUS II IVUS substudy showed >50% resolution of postprocedure incomplete stent apposition at follow-up.5 The reasons for this difference are unclear. In the present study, almost all postprocedural incomplete stent apposition was at the proximal edge of the stent; incomplete stent apposition within the body of the stent was typically resolved before the end of the procedure by additional balloon inflations. In order for incomplete apposition at the proximal edge of the stent to resolve, there would have to be plaque progression or negative remodeling at the proximal edge, something that was not observed in the present study. However, importantly, the long-term prognosis of persistent incomplete stent apposition was favorable in the present study, similar to the TAXUS II IVUS substudy.5

Long-Term Follow-Up After Detection of LSM
Previous studies have suggested that compared with non-LSM groups, LSM was not associated with any MACE after BMS implantation2 or in the TAXUS II and IV IVUS substudies.5,9 In a study of 13 patients who received sirolimus-eluting stents and showed LSM at follow-up, there were no changes in IVUS-measured vessel dimensions and magnitude of LSM CSA, and there were favorable long-term clinical outcomes during the subsequent year.11 The majority of lesions were treated with sirolimus-eluting stents in the present study. As in TAXUS II and IV5,9 and the previously reported BMS group,2 the present study showed favorable long-term clinical outcomes in LSM patients after implantation of sirolimus-eluting and paclitaxel-eluting stents.

Study Limitations
This was a retrospective, observational analysis from a single center. The relation between preintervention plaque characteristics and LSM was not evaluated. Sirolimus-eluting stents were used in most lesions in this study. This study was underpowered to show a difference in MACE rates between LSM and non-LAM patients.

Conclusions
In this single-center experience, LSM occurred in 12% of cases after DES implantation. The predictors of LSM were total stent length, primary stenting in acute MI, and CTO lesions. Importantly, LSM after DES implantation was not associated with any MACE during a mean 10-month follow-up after detection of LSM in the present study population.


*    Acknowledgments
 
This study was supported in part by the Cardiovascular Research Foundation, Seoul, Korea, and a grant from the Korea Health 21 R&D Project, Ministry of Health & Welfare, Korea (0412-CR02-0704-0001).

Disclosures

None.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 
1. Shah VM, Mintz GS, Apple S, Weissman NJ. Background incidence of late malapposition after bare-metal stent implantation. Circulation. 2002; 106: 1753–1755.[Abstract/Free Full Text]

2. Hong MK, Mintz GS, Lee CW, Kim YH, Lee SW, Song JM, Han KH, Kang DH, Song JK, Kim JJ, Park SW, Park SJ. Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation. 2004; 109: 881–886.[Abstract/Free Full Text]

3. Nakamura M, Kataoka T, Honda Y, Bonneau HN, Hibi K, Kitamura K, Tamai H, Aizawa T, Yock PG, Fitzgerald PJ. Late incomplete stent apposition and focal vessel expansion after bare metal stenting. Am J Cardiol. 2003; 92: 1217–1219.[CrossRef][Medline] [Order article via Infotrieve]

4. Serruys PW, Degertekin M, Tanabe K, Abizaid A, Sousa JE, Colombo A, Guagliumi G, Wijns W, Lindeboom WK, Ligthart J, de Feyter PJ, Morice MC, for the RAVEL study group. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (randomized study with the sirolimus-eluting velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions) trial. Circulation. 2002; 106: 798–803.[Abstract/Free Full Text]

5. Tanabe K, Serruys PW, Degertekin M, Grube E, Guagliumi G, Urbaszek W, Bonnier J, Lablanche JM, Siminiak T, Nordrehaug J, Figulla H, Drzewiecki J, Banning A, Hauptmann K, Dudek D, Bruining N, Hamers R, Hoye A, Ligthart JMR, Disco C, Koglin J, Russell ME, Colombo A, for the TAXUS II study group. Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial. Circulation. 2005; 111: 900–905.[Abstract/Free Full Text]

6. TIMI Study Group. The Thrombolysis and Myocardial Infarction (TIMI) trial: phase I findings. N Engl J Med. 1988; 318: 265–270.[Abstract]

7. Park SW, Hong MK, Moon DH, Oh SJ, Lee CW, Kim JJ, Park SJ. Treatment of diffuse in-stent restenosis with rotational atherectomy followed by radiation therapy with a rhenium-188-mercaptoacetyltriglycine-filled balloon. J Am Coll Cardiol. 2001; 38: 631–637.[Abstract/Free Full Text]

8. Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, Pinto FJ, Rosenfield K, Siegel RJ, Tuzcu EM, Yock PG. American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS): a report of the American College of Cardiology task force on clinical expert consensus documents. J Am Coll Cardiol. 2001; 37: 1478–1492.[Free Full Text]

9. Weissman NJ, Koglin J, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Kutcher M, Wong SC, Strickland W, Mooney M, Russell ME, Ellis SG, Stone GW. Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferation: a serial volumetric intravascular ultrasound analysis from the TAXUS-IV trial. J Am Coll Cardiol. 2005; 45: 1201–1205.[Abstract/Free Full Text]

10. Mintz GS, Shah VM, Weissman NJ. Regional remodeling as the cause of late stent malapposition. Circulation. 2003; 107: 2660–2663.[Abstract/Free Full Text]

11. Degertekin M, Serruys PW, Tanabe K, Lee CH, Sousa JE, Colombo A, Morice MC, Ligthart JMR, de Feyter PJ. Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: an intravascular ultrasound analysis. Circulation. 2003; 108: 2747–2750.[Abstract/Free Full Text]


 

CLINICAL PERSPECTIVE

After drug-eluting stent (DES) implantation, late stent malapposition (LSM) has been more frequently observed in follow-up intravascular ultrasound (IVUS) study. The current study comprised 557 patients with 705 native lesions in whom IVUS was performed at index and 6-month follow-up after DES implantation. LSM occurred in 85 lesions (12%). IVUS substudies of the previous randomized SIRIUS and TAXUS trials reported the actual incidence of LSM (8.0% to 9.5%) after DES implantation and showed favorable long-term clinical outcomes of LSM after DES implantation. However, because complex lesions, including very long lesions, chronic total occlusion lesions, and thrombotic lesions, were excluded in the previous randomized trials, the actual incidence of LSM in a real-world daily practice could not be determined. In the present study of real-world patients, the actual incidence of LSM at a 6-month follow-up after DES implantation appeared to higher than in the randomized trials and appeared to be higher than in patients treated with bare-metal stents. As in the SIRIUS and TAXUS randomized trials, development of LSM after DES implantation in real-world patients with more complex lesion subsets was not associated with any major adverse cardiac events during a subsequent 10-month follow-up. Independent predictors of LSM after DES implantation in the present study were longer total stent length, primary stenting in acute myocardial infarction, and chronic total occlusion lesions. In conclusion, LSM occurs in 12% of patients after DES implantation. The long-term clinical outcomes in LSM after DES implantation were favorable in real-world patients.




This article has been cited by other articles:


Home page
CirculationHome page
A. Maehara, G. S. Mintz, A. J. Lansky, B. Witzenbichler, G. Guagliumi, B. Brodie, M. A. Kellett Jr, H. Parise, R. Mehran, and G. W. Stone
Volumetric Intravascular Ultrasound Analysis of Paclitaxel-Eluting and Bare Metal Stents in Acute Myocardial Infarction: The Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction Intravascular Ultrasound Substudy
Circulation, November 10, 2009; 120(19): 1875 - 1882.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc IntervHome page
A. Maehara, G. S. Mintz, and N. J. Weissman
Advances in Intravascular Imaging
Circ Cardiovasc Interv, October 1, 2009; 2(5): 482 - 490.
[Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
K. Waseda, A. Miyazawa, J. Ako, T. Hasegawa, I. Tsujino, R. Sakurai, P. G. Yock, Y. Honda, D. E. Kandzari, M. B. Leon, et al.
Intravascular Ultrasound Results From the ENDEAVOR IV Trial: Randomized Comparison Between Zotarolimus- and Paclitaxel-Eluting Stents in Patients With Coronary Artery Disease
J. Am. Coll. Cardiol. Intv., August 1, 2009; 2(8): 779 - 784.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. E. Drachman
Drug-Eluting Stents in Animals and Patients: Where Do We Stand Today?
Circulation, July 14, 2009; 120(2): 101 - 103.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
F. Alfonso, M.-J. Perez-Vizcayno, M. Ruiz, A. Suarez, M. Cazares, R. Hernandez, J. Escaned, C. Banuelos, P. Jimenez-Quevedo, and C. Macaya
Coronary aneurysms after drug-eluting stent implantation clinical, angiographic, and intravascular ultrasound findings.
J. Am. Coll. Cardiol., June 2, 2009; 53(22): 2053 - 2060.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
N. Gonzalo, P. Barlis, P. W. Serruys, H. M. Garcia-Garcia, Y. Onuma, J. Ligthart, and E. Regar
Incomplete Stent Apposition and Delayed Tissue Coverage Are More Frequent in Drug-Eluting Stents Implanted During Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction Than in Drug-Eluting Stents Implanted for Stable/Unstable Angina: Insights From Optical Coherence Tomography
J. Am. Coll. Cardiol. Intv., May 1, 2009; 2(5): 445 - 452.
[Abstract] [Full Text] [PDF]


Home page
Ther Adv Cardiovasc DisHome page
B. E. Stahli, G. G. Camici, and F. C. Tanner
Drug-eluting stent thrombosis
Therapeutic Advances in Cardiovascular Disease, February 1, 2009; 3(1): 45 - 52.
[Abstract] [PDF]


Home page
Eur Heart JHome page
Ph. G. Steg, K. A.A. Fox, K. A. Eagle, M. Furman, F. Van de Werf, G. Montalescot, S. G. Goodman, A. Avezum, W. Huang, J. M. Gore, et al.
Mortality following placement of drug-eluting and bare-metal stents for ST-segment elevation acute myocardial infarction in the Global Registry of Acute Coronary Events
Eur. Heart J., February 1, 2009; 30(3): 321 - 329.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
K. Tsujita, A. Maehara, G. S. Mintz, M. Poon, G. Maiolino, T. Sugaya, K. Igarashi, and M. Ochiai
Cross-Sectional and Longitudinal Positive Remodeling After Subintimal Drug-Eluting Stent Implantation: Multiple Late Coronary Aneurysms, Stent Fractures, and a Newly Formed Stent Gap Between Previously Overlapped Stents
J. Am. Coll. Cardiol. Intv., February 1, 2009; 2(2): 156 - 158.
[Full Text] [PDF]


Home page
Eur Heart JHome page
A. K.M. Hassan, S. C. Bergheanu, T. Stijnen, B. L. van der Hoeven, J. D. Snoep, J. W.M. Plevier, M. J. Schalij, and J. W. Jukema
Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis
Eur. Heart J., January 21, 2009; (2009) ehn553v1.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. Kelbaek, L. Thuesen, S. Helqvist, P. Clemmensen, L. Klovgaard, A. Kaltoft, B. Andersen, H. Thuesen, T. Engstrom, H. E. Botker, et al.
Drug-Eluting Versus Bare Metal Stents in Patients With ST-Segment-Elevation Myocardial Infarction: Eight-Month Follow-Up in the Drug Elution and Distal Protection in Acute Myocardial Infarction (DEDICATION) Trial
Circulation, September 9, 2008; 118(11): 1155 - 1162.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
B. L. van der Hoeven, S.-S. Liem, J. Dijkstra, S. C. Bergheanu, H. Putter, M. L. Antoni, D. E. Atsma, M. Bootsma, K. Zeppenfeld, J. W. Jukema, et al.
Stent Malapposition After Sirolimus-Eluting and Bare-Metal Stent Implantation in Patients with ST-Segment Elevation Myocardial Infarction: Acute and 9-Month Intravascular Ultrasound Results of the MISSION! Intervention Study
J. Am. Coll. Cardiol. Intv., April 1, 2008; 1(2): 192 - 201.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
B. K. Courtney, N. R. Munce, K. J. Anderson, A. S. Thind, G. Leung, P. E. Radau, F. S. Foster, I. A. Vitkin, R. S. Schwartz, A. J. Dick, et al.
Innovations in imaging for chronic total occlusions: a glimpse into the future of angiography's blind-spot
Eur. Heart J., March 1, 2008; 29(5): 583 - 593.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A. Colombo and A. Latib
Late incomplete stent apposition after drug-eluting stent implantation: a true risk factor or "an innocent bystander"?
Heart, March 1, 2008; 94(3): 253 - 254.
[Full Text] [PDF]


Home page
HeartHome page
R Hoffmann, M-C Morice, J W Moses, P J Fitzgerald, L Mauri, G Breithardt, J Schofer, P W Serruys, H-P Stoll, and M B Leon
Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials
Heart, March 1, 2008; 94(3): 322 - 328.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. L. van der Hoeven, S.-S. Liem, J. W. Jukema, N. Suraphakdee, H. Putter, J. Dijkstra, D. E. Atsma, M. Bootsma, K. Zeppenfeld, P. V. Oemrawsingh, et al.
Sirolimus-eluting stents versus bare-metal stents in patients with ST-segment elevation myocardial infarction: 9-month angiographic and intravascular ultrasound results and 12-month clinical outcome results from the MISSION! Intervention Study.
J. Am. Coll. Cardiol., February 12, 2008; 51(6): 618 - 626.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
F. Alfonso, A. Suarez, M. J. Perez-Vizcayno, R. Moreno, J. Escaned, C. Banuelos, P. Jimenez, E. Bernardo, D. J. Angiolillo, R. Hernandez, et al.
Intravascular Ultrasound Findings During Episodes of Drug-Eluting Stent Thrombosis
J. Am. Coll. Cardiol., November 20, 2007; 50(21): 2095 - 2097.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M.-K. Hong, G. S. Mintz, C. W. Lee, D.-W. Park, S.-W. Lee, Y.-H. Kim, D.-H. Kang, S.-S. Cheong, J.-K. Song, J.-J. Kim, et al.
Impact of Late Drug-Eluting Stent Malapposition on 3-Year Clinical Events
J. Am. Coll. Cardiol., October 9, 2007; 50(15): 1515 - 1516.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. Sianos, M. I. Papafaklis, J. Daemen, S. Vaina, C. A. van Mieghem, R. T. van Domburg, L. K. Michalis, and P. W. Serruys
Angiographic Stent Thrombosis After Routine Use of Drug-Eluting Stents in ST-Segment Elevation Myocardial Infarction: The Importance of Thrombus Burden
J. Am. Coll. Cardiol., August 14, 2007; 50(7): 573 - 583.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. R. Dixon, C. L. Grines, and W. W. O'Neill
The Year in Interventional Cardiology
J. Am. Coll. Cardiol., July 17, 2007; 50(3): 270 - 285.
[Full Text] [PDF]


Home page
Eur Heart JHome page
D. A. Siqueira, A. A. Abizaid, J. d. R. Costa, F. Feres, L. A. Mattos, R. Staico, A. A. Abizaid, L. F. Tanajura, A. Chaves, M. Centemero, et al.
Late incomplete apposition after drug-eluting stent implantation: incidence and potential for adverse clinical outcomes
Eur. Heart J., June 1, 2007; 28(11): 1304 - 1309.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
G. S. Mintz
What to Do About Late Incomplete Stent Apposition?
Circulation, May 8, 2007; 115(18): 2379 - 2381.
[Full Text] [PDF]


Home page
CirculationHome page
S. Cook, P. Wenaweser, M. Togni, M. Billinger, C. Morger, C. Seiler, R. Vogel, O. Hess, B. Meier, and S. Windecker
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Circulation, May 8, 2007; 115(18): 2426 - 2434.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
H. M.M. van Beusekom, F. Saia, J. D. Zindler, P. A. Lemos, S. L. S.-t. Hoor, M. A.H. van Leeuwen, P. J. de Feijter, P. W. Serruys, and W. J. van der Giessen
Drug-eluting stents show delayed healing: paclitaxel more pronounced than sirolimus
Eur. Heart J., April 12, 2007; (2007) ehm064v1.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. W. Serruys and J. Daemen
Late Stent Thrombosis: A Nuisance in Both Bare Metal and Drug-Eluting Stents
Circulation, March 20, 2007; 115(11): 1433 - 1439.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. S. Mintz and N. J. Weissman
Intravascular Ultrasound in the Drug-Eluting Stent Era
J. Am. Coll. Cardiol., August 1, 2006; 48(3): 421 - 429.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hong, M.-K.
Right arrow Articles by Park, S.-J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hong, M.-K.
Right arrow Articles by Park, S.-J.
Related Collections
Right arrow Catheter-based coronary interventions: stents
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC