| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Circulation. 2005;111:2611-2616.)
© 2005 American Heart Association, Inc.
Imaging |
From the Cardiac Ultrasound Laboratory in the Cardiology Division of the Department of Medicine (I.A.S., M.D.H., J.G.M., A.C.T.R., J.L.G., M.J.R., M.H.P., M.S.-C.), Cardiovascular Research Center (F.I., R.H., M.J.R., K.D.B., M.S.-C.), Department of Anesthesia and Critical Care (F.I., R.H., W.S.), and Institute for Technology Assessment (E.F.H.), Massachusetts General Hospital and Harvard Medical School, Boston, Mass; Echocardiography Laboratory in the Cardiology Division of the Department of Medicine, Sir Mortimer B. Davis Jewish General Hospital and McGill University, Montreal, Quebec, Canada (I.A.S.); and INSERM U644, Rouen, France (G.D.).
Correspondence to Marielle Scherrer-Crosbie, MD, PhD, Cardiac Ultrasound Laboratory, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114. E-mail marielle{at}crosbie.com
Received May 13, 2004; revision received January 9, 2005; accepted January 11, 2005.
| Abstract |
|---|
|
|
|---|
Methods and Results TDI was performed in 10 healthy mice to measure endocardial (vendo) and epicardial systolic velocities and SR. In further experiments, TDI indices were compared with dP/dtmax and with sonomicrometer-derived regional velocities, at rest and after administration of dobutamine or esmolol. TDI indices were also studied serially in 8 mice before and 4 and 7 hours after endotoxin challenge. Myocardial velocities and SR were obtained in all mice with low measurement variability. TDI indices increased with administration of dobutamine (vendo from 2.2±0.3 to 3.8±0.2 cm/s [P<0.01]; SR from 12±2 to 20±2 s1 [P<0.05]) and decreased with administration of esmolol (vendo 1.4±0.2 cm/s [P<0.05]; SR 6±1 s1 [P<0.01]). Both indices correlated strongly with dP/dtmax (r2=0.79 for SR and r2= 0.69 for vendo; both P<0.0001). SR and shortening fraction were predictors of dP/dtmax even after adjustment for the confounding effect of the other variables. Vendo correlated closely with sonomicrometer-measured velocity (r2=0.71, P<0.0005). After endotoxin challenge, decreases in both vendo and SR were detected before decreases in shortening fraction became manifest.
Conclusions Myocardial velocities and SR can be measured noninvasively in mice with the use of TDI. Both indices are sensitive markers for quantifying LV global and regional function in mice.
Key Words: echocardiography systole inotropic agents
| Introduction |
|---|
|
|
|---|
Tissue Doppler imaging (TDI) is a novel echocardiographic technique that permits quantification of systolic and diastolic regional myocardial velocities and strain rate (SR), the rate of fractional tissue deformation in response to applied force. Both systolic velocities and SR have been shown to be sensitive indices of LV regional systolic function.812 Endocardial to epicardial velocity gradients and maximal SR may identify LV systolic dysfunction before ejection fraction is altered11,13 and are less dependent on loading conditions than is ejection fraction.810
Because of their small size and rapid heart rate, the feasibility of TDI assessment of regional myocardial systolic function in mice is uncertain. Successful advances in high-frequency and high-frame-rate TDI may overcome these obstacles. Recently, pulsed Doppler acquired at the mitral annulus has been applied to assess diastolic function in mice,14 and a novel speckle method appears promising.15 To validate TDI measurements in mice, the variability of murine myocardial velocities and SR was determined, and TDI-derived velocities were compared with sonomicrometer-derived velocities. TDI was performed in various inotropic states, and SF, myocardial velocities, and SR were compared with an index of LV contractility, dP/dtmax. TDI indices were applied in a model of endotoxin-induced LV dysfunction.
Regional myocardial velocities and SR were obtained noninvasively in mice with low variability. Changes in endocardial velocity (vendo) and SR in response to agents that alter inotropy correlated with invasive hemodynamic and sonomicrometric assessments. In a model of acute LV dysfunction by endotoxin challenge, vendo and SR decreased before SF was altered.
| Methods |
|---|
|
|
|---|
TDI analysis was performed offline with the use of a customized version of the EchoPac Software (GE Medical). Myocardial velocities were computed from a region of interest (0.2x0.2 mm) that was manually positioned along the posterior wall on the endocardial and epicardial surfaces to measure the peak systolic vendo and epicardial velocity (vepi), respectively (Figure 1A). Radial SR was then measured over an axial distance of distance L of 1 mm (width 0.6 mm). In the present study a tissue Doppler frequency of 6.4 MHz was used, corresponding to a wavelength of 0.24 mm. The transmitted pulse is longer than 1 wavelength, and the received signal is eventually sampled with a sample distance of 0.35 mm. The smallest distance L, and thus the smallest possible spatial resolution, is therefore 0.35 mm. As with all gradient estimators, the quality of the strain rate estimate also improves with increasing L. A strain length of 1 mm was used in the present study to balance estimator quality versus spatial resolution. The temporal smoothing filters were turned off for all measurements. Time-velocity and time-SR plots were obtained, and peak systolic velocities and SR were measured. The values obtained in 5 consecutive cardiac cycles were averaged.
|
The normal patterns and intraobserver and interobserver variabilities of vendo, vepi, and SR were measured in 10 lightly sedated mice (ketamine 80 mg/kg administered intraperitoneally) by 2 independent observers (J.G.M. and M.S.-C.). From the color-coded images, each observer measured velocities and SR. A single observer (M.S.-C.) repeated the measurements several weeks later. Interobserver and intraobserver variabilities were calculated as the difference between the 2 observations divided by the means of the observations and were expressed as both absolute numbers and percentages.
Comparison of TDI Parameters With Hemodynamic Indices of LV Systolic Function
Hemodynamic parameters were obtained in 17 mice (weight, 26±1 g) with the use of a 1.4F high-fidelity micromanometer catheter (Millar Instruments), as described previously.2,16 Echocardiographic parasternal short-axis 2D and M-mode images were acquired simultaneously with invasive hemodynamics. In 9 mice, after baseline measurements were obtained, dobutamine (30 µg/kg per minute) and esmolol (10 mg/kg per minute) were infused through the right jugular vein in a random order. The drugs were infused until the heart rate increased (or decreased) 10% or the dP/dtmax increased (or decreased) 20%. When either of these criteria was met, a second set of echocardiographic and hemodynamic measurements was recorded. The drug was then discontinued until the heart rate and dP/dtmax returned to baseline, and the second drug was infused. Graded inotropic modulation with lower doses of esmolol (1 and 3 mg/kg per minute) and dobutamine (10 µg/kg per minute) was similarly studied in 8 subsequent animals (1 mouse died before reliable image acquisition with the highest ß-blocker dose) to provide intermediate data points in the relationship of TDI parameters with hemodynamic indices.
Comparison of TDI Parameters With Sonomicrometer-Derived Indices
Five mice (weight, 30±2 g) were anesthetized with the use of isoflurane and underwent thoracotomy. Piezoelectric crystals (0.7 mm; Sonometrics) were implanted in the midventricular portion of the LV. Two crystals were attached to the epicardium with a cyanoacrylate adhesive (1 on the anterior wall, 1 on the posterior wall), and the third crystal was implanted within the endocardial layer of the posterior wall.17 The sonomicrometry system was set for a 960-Hz sample rate, and the individual crystal gain/reject controls were adjusted for optimal signals. The ultrasound transducer was positioned to avoid electrical or mechanical interference with the crystals. Echocardiographic epicardial short-axis views and sonomicrometer data sets were acquired simultaneously, at baseline and after administration of esmolol (5 mg/kg) or dobutamine (625 µg/kg).
Velocity values from the sonomicrometry data were calculated by taking the temporal derivative of the intercrystal distances with the use of a sliding window of 8 ms (9 samples) followed by a sliding, 5-point median filter. The velocities were then plotted versus time, and the peak systolic velocities from 5 consecutive cardiac cycles were identified and averaged. Peak systolic TDI velocities sampled from the posterior endocardial wall were compared with the peak sonomicrometry velocities computed from the anterior epicardial and posterior endocardial crystal pair.
Acute LV Dysfunction Model
Eight mice (weight, 26±2 g) were intraperitoneally injected with 50 mg/kg of Escherichia coli lipopolysaccharide (LPS). Echocardiography was performed before and 4 and 7 hours after injection with the use of light sedation (ketamine 80 mg/kg administered intraperitoneally).
Statistical Analysis
The JMP 5.1 statistical software (SAS Institute Inc) was used. Values are expressed as mean±SEM except for intraobserver and interobserver variabilities, which are expressed as mean±SD. After we tested for inequality of variances, the differences between echocardiographic and hemodynamic variables before and after inotropic alterations were tested with ANOVA for repeated measurements with a contrast analysis (each group/dose versus rest/baseline).18 When differences in variances were found, ordinal logistic fit was applied.18 The echocardiographic and hemodynamic variables were correlated with the use of a mixed model accounting for the mouse effect.18 A multiple linear regression analysis was used to test the echocardiographic predictors of dP/dtmax. A probability value <0.05 was considered significant.
| Results |
|---|
|
|
|---|
Intraobserver and Interobserver Variabilities
Intraobserver and interobserver variabilities were smallest for vendo (the SD of the error was 2.5% for intraobserver variability and 3.6% for interobserver variability) and largest for vepi (the SD of the error was 10.6% for intraobserver variability and 5.8% for interobserver variability) (Table 1). The SR had a SD of the error of 8.4% for intraobserver variability and 4.4% for interobserver variability.
|
Comparison of LV Systolic Function Assessment by Echocardiography and Hemodynamic Variables
Dobutamine infusion increased SF by 22% (P<0.05), vendo by 73% (P<0.01), and SR by 67% (P<0.05) (Table 2). Esmolol infusion decreased SF by 20% (P<0.01), vendo by 36% (P<0.05), and SR by 50% (P<0.01). The SF, vendo, and SR correlated with the maximal derivative of the developed pressure dP/dtmax (Figure 2). Tissue Doppler parameters correlated strongly with dP/dtmax (r2=0.79 for SR and r2= 0.69 for vendo; P<0.0001 for both). SF also correlated with dP/dtmax (r2=0.46, P<0.0001). When all echocardiographic parameters were analyzed by multivariate analysis, SR (<0.0001) and SF (0.03) were each significantly related to dP/dtmax even after adjustment for the confounding effects of the other variables, whereas vendo did not improve prediction of dP/dtmax based on SF and SR. When SR was omitted from the multivariate analysis, both SF and vendo were predictors of dP/dtmax (P<0.02 for SF and P<0.0001 for vendo).
|
|
Relationship of TDI Velocity With Sonomicrometry
The peak systolic velocity measured by sonomicrometry was 1.9±0.2 cm/s, and the wall thickening was 26±3%. An example of the sonomicrometer-derived posterior wall velocity curves is shown in Figure 3. Peak systolic velocity measured by TDI (vendo) was 1.2±0.2 cm/s and correlated closely with sonomicrometer-measured velocity (TDI velocity=0.71xsonomicrometer velocity0.17; r2=0.72, P<0.0005). However, TDI-derived velocity consistently underestimated sonomicrometer-derived velocity (P<0.0001).
|
Endotoxin Challenge
Injection of 50 mg/kg LPS resulted in a progressive decline of LV systolic function (Figure 4). Four hours after LPS injection, SF was unchanged (50±3% at baseline and 45±11% 4 hours after injection), whereas vendo decreased by 32% (from 3.1±0.4 to 2.1±0.5 cm/s; P<0.005) and SR by 38% (from 17±5 to 11±4 s1; P<0.01). Seven hours after injection, all echocardiographic parameters of LV systolic function were decreased.
|
| Discussion |
|---|
|
|
|---|
Applying TDI to murine hearts presents unique challenges because of the small size and fast heart rate of the mouse. In the present study the axial and lateral resolutions of the color Doppler at the depth studied were 0.35 mm, allowing spatial differentiation of the endocardial and epicardial layers in systole (the wall thickness is 1.5 to 1.8 mm at midsystole). No attempts were made to study the diastolic phase of the cardiac cycle when the wall thickness is 0.6 to 0.8 mm. The frame rate was 483 frames per second. With an average murine heart rate of 539 bpm, 54 frames per cardiac cycle were obtained, a rate similar to that used by others (with close correlation of TDI-derived to MRI-derived measurements of strain9). The myocardial velocities and radial SR patterns obtained in the healthy mice were very similar to those observed in large animals, with 2 positive velocity peaks.8,12,19 In larger animal studies, the first systolic peak has been identified as concomitant to isovolumic contraction.20 The normal value of the posterior wall vendo reported in the present study was similar to that found in large animals10,12; however, the SR was significantly higher.
The intraobserver and interobserver reproducibility values of TDI measurements in mice were low and comparable to those reported for M-mode measurements routinely described in the literature.5,21 Of note, the variability of the SR measurement is slightly higher than that of vendo, likely because of the fact that SR is the spatial derivative of the velocities, increasing the level of noise detected. The variability of vepi was the highest, and it was not used in subsequent experiments.
In the present study both vendo and SR correlated closely with dP/dtmax, a sensitive measure of LV systolic function.22,23 SR was predictive of dP/dtmax even after adjustment for the confounding effects of SF and vendo. Peak systolic myocardial velocity has been reported to correlate with dP/dtmax in patients,24 and peak systolic SR closely correlated with dP/dtmax in large animals.10,12 Both findings were confirmed in mice in the present study.
Sonomicrometry remains the gold standard for measuring wall thickening in animals. This technique has previously been applied to mice to measure wall thickening and global LV function.17,25 We used an endocardial crystal to obtain endocardial thickening measurements and derived the endocardial velocities. Vendo correlated well with the sonomicrometer-derived peak systolic velocity, used as a gold standard of regional myocardial velocity. There was, however, a significant underestimation of the sonomicrometer-derived velocity by vendo (0.71±0.11 cm/s). A possible explanation for this discrepancy is that TDI velocities were sampled at a point in the posterior myocardium relative to the tip of the transducer, whereas, in the sonomicrometry analysis, the velocity was computed from the distance between a crystal moving with the posterior endocardium relative to a crystal moving with the anterior epicardium wall. In the sonomicrometry-derived velocity measurements, the velocity of the anterior epicardium is added to the velocity of the posterior endocardium and should be taken into account in mice models. In a murine model of endotoxin-induced LV failure, vendo and SR detected LV systolic dysfunction earlier than conventional echocardiographic indices such as SF. The sensitivity of TDI parameters in detecting subtle LV dysfunction had been reported in human asymptomatic carriers of muscular dystrophy.13 In rats, the gradient between endocardial and epicardial velocity, a measure of the rate of deformation, was more sensitive than SF in the detection of early LV systolic dysfunction after aortic banding.11 In mice, TDI appears to have the potential to detect subtle differences in LV function between murine strains or genetically modified mice.
There were several limitations in the present study. First, apical views are difficult to obtain and poorly reproducible in small rodents, precluding the reliable analysis of longitudinal velocities and SR.26 Thus, we relied on the parasternal images. Great care must be taken to avoid motion and rib artifacts and poor alignment of the posterior wall perpendicular to the beam. Second, the posterior wall myocardial velocities were easier to analyze than those of the anterior/anteroseptal wall. Anterior wall velocities were much lower than posterior wall velocities, and their variability was large, precluding reliable analysis. This has been reported previously in humans27,28 and, very recently, in mice.15 The reason for the discrepancy between the velocities of the posterior wall and the anterior wall remains unclear. Third, the measurement of sonomicrometer-derived wall thickening required the subtraction of the distance of 2 pairs of crystals, the epicardium to epicardium and the epicardium to endocardium pairs, which may double the possible error due to positioning of the crystals and to the level of noise.
In conclusion, TDI is feasible in mice, and indices of LV regional systolic function can be obtained reproducibly. In addition to simple parameters such as peak velocities and strain rate, the temporal pattern of the curves may provide additional information on LV function. Peak systolic endocardial velocity and myocardial SR correlate closely with dP/dtmax and detect LV dysfunction earlier than SF, thereby potentially providing more information and detecting more subtle differences in LV systolic function compared with conventional echocardiographic measurements.
| Acknowledgments |
|---|
We are grateful to Liane Cral, Susan Floer, Glenn Lie, and Andreas Heimdal from GE Medical for their technical assistance. We thank Dr Arthur E. Weyman for his thorough reading and critical comments of the manuscript.
| References |
|---|
|
|
|---|
2. Scherrer-Crosbie M, Ullrich R, Bloch KD, Nakajima H, Nasseri B, Aretz HT, Lindsey M, Vançon AC, Huang PL, Lee RT, Zapol WM, Picard MH. Nitric oxide synthase 3 limits left ventricular remodeling after myocardial infarction in mice. Circulation. 2001; 104: 12861291.
3. Knuefermann P, Nemoto S, Misra A, Nozaki N, Defreitas G, Goyert SM, Carabello BA, Mann DL, Vallejo JG. CD14-deficient mice are protected against lipopolysaccharide-induced cardiac inflammation and left ventricular dysfunction. Circulation. 2002; 106: 26082615.
4. Shiomi T, Tsutsui H, Hayashidani S, Suematsu N, Ikeuchi M, Wen J, Ishibashi M, Kubota T, Egashira K, Takeshita A. Pioglitazone, a peroxisome proliferator-activated receptor-gamma agonist, attenuates left ventricular remodeling and failure after experimental myocardial infarction. Circulation. 2002; 106: 31263132.
5. Tanaka N, Dalton N, Mao L, Rockman HA, Peterson KL, Gottshall KR, Hunter JJ, Chien KR, Ross J Jr. Transthoracic echocardiography in models of cardiac disease in the mouse. Circulation. 1996; 94: 11091117.
6. Scherrer-Crosbie M, Steudel W, Hunziker PR, Liel-Cohen N, Ullrich R, Zapol WM, Picard MH. Three-dimensional echocardiographic assessment of left ventricular wall motion abnormalities in mouse myocardial infarction. J Am Soc Echocardiogr. 1999; 12: 834840.[CrossRef][Medline] [Order article via Infotrieve]
7. Nemoto S, DeFreitas G, Mann DL, Carabello BA. Effects of changes in left ventricular contractility on indexes of contractility in mice. Am J Physiol. 2002; 283: H2504H2510.
8. Gorcsan J III, Strum DP, Mandarino WA, Gulati VK, Pinsky MR. Quantitative assessment of alterations in regional left ventricular contractility with color-coded tissue Doppler echocardiography: comparison with sonomicrometry and pressure-volume relations. Circulation. 1997; 95: 24232433.
9. Edvardsen T, Urheim S, Skulstad H, Steine K, Ihlen H, Smiseth OA. Quantification of left ventricular systolic function by tissue Doppler echocardiography: added value of measuring pre- and postejection velocities in ischemic myocardium. Circulation. 2002; 105: 20712077.
10. Greenberg NL, Firstenberg MS, Castro PL, Main M, Travaglini A, Odabashian JA, Drinko JK, Rodriguez LL, Thomas JD, Garcia MJ. Doppler-derived myocardial systolic strain rate is a strong index of left ventricular contractility. Circulation. 2002; 105: 99105.
11. Derumeaux G, Mulder P, Richard V, Chagraoui A, Nafeh C, Bauer F, Henry JP, Thuillez C. Tissue Doppler imaging differentiates physiological from pathological pressure-overload left ventricular hypertrophy in rats. Circulation. 2002; 105: 16021608.
12. Weidemann F, Jamal F, Sutherland GR, Claus P, Kowalski M, Hatle L, De Scheerder I, Bijnens B, Rademakers FE. Myocardial function defined by strain rate and strain during alterations in inotropic states and heart rate. Am J Physiol. 2002; 283: H792H799.
13. Agretto A, Politano L, Bossone E, Petretta VR, DIsa S, Passamano L, Comi LI, Erbel R. Pulsed Doppler tissue imaging in dystrophinopathic cardiomyopathy. J Am Soc Echocardiogr. 2002; 15: 891899.[CrossRef][Medline] [Order article via Infotrieve]
14. Schaefer A, Klein G, Brand B, Lippolt P, Drexler H, Meyer GP. Evaluation of left ventricular diastolic function by pulsed Doppler tissue imaging in mice. J Am Soc Echocardiogr. 2003; 16: 11441149.[CrossRef][Medline] [Order article via Infotrieve]
15. DHooge J, Thijs D, Sipido K, Claus P, Bijnens B, Vand de Wert F, Suetens P, Sutherland GR. Ultrasonic strain and strain rate imaging : a new tool to quantify regional myocardial function in mice. Eur Heart J. 2004; 25: 475. Abstract.
16. Ullrich R, Scherrer-Crosbie M, Bloch KD, Ichinose F, Nakajima H, Picard MH, Zapol WM, Quezado ZM. Congenital deficiency of nitric oxide synthase 2 protects against endotoxin-induced myocardial dysfunction in mice. Circulation. 2000; 102: 14401446.
17. Takaoka H, Esposito G, Mao L, Suga H, Rockman HA. Heart size-independent analysis of myocardial function in murine pressure overload hypertrophy. Am J Physiol. 2002; 282: H2190H2197.
18. Scheffe H. The Analysis of Variance. New York, NY: Wiley Publications; 1959.
19. Edvardsen T, Gerber BL, Garot J, Bluemke DA, Lima JA, Smiseth OA. Quantitative assessment of intrinsic regional myocardial deformation by Doppler strain rate echocardiography in humans: validation against three-dimensional tagged magnetic resonance imaging. Circulation. 2002; 106: 5056.
20. Vogel M, Cheung MM, Li J, Kristiansen SB, Schmidt MR, White PA, Sorensen K, Redington AN. Noninvasive assessment of left ventricular force-frequency relationships using tissue Doppler-derived isovolumic acceleration: validation in an animal model. Circulation. 2003; 107: 16471652.
21. Hoit BD, Khoury SF, Kranias EG, Ball N, Walsh RA. In vivo echocardiographic detection of enhanced left ventricular function in gene-targeted mice with phospholamban deficiency. Circ Res. 1995; 77: 632637.
22. Quinones MA, Gaasch WH, Alexander JK. Influence of acute changes in preload, afterload, contractile state and heart rate on ejection and isovolumic indices of myocardial contractility in man. Circulation. 1976; 53: 293302.
23. Baim DS, Grossman W. Cardiac Catheterization, Angiography and Intervention. Baltimore, Md: Williams & Wilkins; 1996.
24. Yamada H, Oki T, Tabata T, Iuchi A, Ito S. Assessment of left ventricular systolic wall motion velocity with pulsed tissue Doppler imaging: comparison with peak dP/dt of the left ventricular pressure curve. J Am Soc Echocardiogr. 1998; 11: 442449.[CrossRef][Medline] [Order article via Infotrieve]
25. Kubota T, Mahler CM, McTiernan CF, Wu CC, Feldman MD, Feldman AM. End-systolic pressure-dimension relationship of in situ mouse left ventricle. J Mol Cell Cardiol. 1998; 30: 357363.[CrossRef][Medline] [Order article via Infotrieve]
26. Pollick C, Hale SL, Kloner RA. Echocardiographic and cardiac Doppler assessment of mice. J Am Soc Echocardiogr. 1995; 8: 602610.[CrossRef][Medline] [Order article via Infotrieve]
27. Palka P, Lange A, Fleming AD, Sutherland GR, Fenn LN, McDicken WN. Doppler tissue imaging: myocardial wall motion velocities in normal subjects. J Am Soc Echocardiogr. 1995; 8: 659668.[CrossRef][Medline] [Order article via Infotrieve]
28. Derumeaux G, Cochonneau O, Douillet R, Cribier A, Letac B. Comparaison des velocites myocardiques par Doppler couleur tissulaire chez des sujets normaux et dans les cardiomyopathies dilatees. Arch Mal Coeur Vaiss. 1997; 90: 773778.[Medline] [Order article via Infotrieve]
Related Article:
Circulation 2005 111: 2551.
This article has been cited by other articles:
![]() |
Y. Peng, Z. B. Popovic, N. Sopko, J. Drinko, Z. Zhang, J. D. Thomas, and M. S. Penn Speckle tracking echocardiography in the assessment of mouse models of cardiac dysfunction Am J Physiol Heart Circ Physiol, August 1, 2009; 297(2): H811 - H820. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Stypmann, M. A Engelen, C. Troatz, M. Rothenburger, L. Eckardt, and K. Tiemann Echocardiographic assessment of global left ventricular function in mice Lab Anim, April 1, 2009; 43(2): 127 - 137. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Dinkel, S. H. Bartling, J. Kuntz, M. Grasruck, A. Kopp-Schneider, M. Iwasaki, S. Dimmeler, R. Gupta, W. Semmler, H.-U. Kauczor, et al. Intrinsic Gating for Small-Animal Computed Tomography: A Robust ECG-Less Paradigm for Deriving Cardiac Phase Information and Functional Imaging Circ Cardiovasc Imaging, November 1, 2008; 1(3): 235 - 243. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Derumeaux, F. Ichinose, M. J. Raher, J. G. Morgan, T. Coman, C. Lee, J. M. Cuesta, H. Thibault, K. D. Bloch, M. H. Picard, et al. Myocardial Alterations in Senescent Mice and Effect of Exercise Training: A Strain Rate Imaging Study Circ Cardiovasc Imaging, November 1, 2008; 1(3): 227 - 234. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Urashima, M. Zhao, R. Wagner, G. Fajardo, S. Farahani, T. Quertermous, and D. Bernstein Molecular and physiological characterization of RV remodeling in a murine model of pulmonary stenosis Am J Physiol Heart Circ Physiol, September 1, 2008; 295(3): H1351 - H1368. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. G. Tankersley, H. C. Champion, E. Takimoto, K. Gabrielson, D. Bedja, V. Misra, H. El-Haddad, R. Rabold, and W. Mitzner Exposure to inhaled particulate matter impairs cardiac function in senescent mice Am J Physiol Regulatory Integrative Comp Physiol, July 1, 2008; 295(1): R252 - R263. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Weytjens, P. R. Franken, J. D'hooge, S. Droogmans, B. Cosyns, T. Lahoutte, and G. Van Camp Doppler myocardial imaging in the diagnosis of early systolic left ventricular dysfunction in diabetic rats Eur J Echocardiogr, May 1, 2008; 9(3): 326 - 333. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. D. Huebner, D. S. Jassal, O. Halevy, M. Pines, and J. E. Anderson Functional resolution of fibrosis in mdx mouse dystrophic heart and skeletal muscle by halofuginone Am J Physiol Heart Circ Physiol, April 1, 2008; 294(4): H1550 - H1561. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Revera, L. van der Merwe, M. Heradien, A. Goosen, V. A. Corfield, P. A. Brink, and J. C. Moolman-Smook Troponin T and {beta}-myosin mutations have distinct cardiac functional effects in hypertrophic cardiomyopathy patients without hypertrophy Cardiovasc Res, March 1, 2008; 77(4): 687 - 694. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Kennedy, J. Elkareh, A. Shidyak, A. P. Shapiro, S. Smaili, K. Mutgi, S. Gupta, J. Tian, E. Morgan, S. Khouri, et al. Partial nephrectomy as a model for uremic cardiomyopathy in the mouse Am J Physiol Renal Physiol, February 1, 2008; 294(2): F450 - F454. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Afilalo, I. A. Sebag, L. E. Chalifour, D. Rivas, R. Akter, K. Sharma, and G. Duque Age-related changes in lamin A/C expression in cardiomyocytes Am J Physiol Heart Circ Physiol, September 1, 2007; 293(3): H1451 - H1456. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. G. Neilan, S. L. Blake, F. Ichinose, M. J. Raher, E. S. Buys, D. S. Jassal, E. Furutani, T. M. Perez-Sanz, A. Graveline, S. P. Janssens, et al. Disruption of Nitric Oxide Synthase 3 Protects Against the Cardiac Injury, Dysfunction, and Mortality Induced by Doxorubicin Circulation, July 31, 2007; 116(5): 506 - 514. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Thibault, L. Gomez, E. Donal, G. Pontier, M. Scherrer-Crosbie, M. Ovize, and G. Derumeaux Acute myocardial infarction in mice: assessment of transmurality by strain rate imaging Am J Physiol Heart Circ Physiol, July 1, 2007; 293(1): H496 - H502. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Ballo, A. Bocelli, and S. Mondillo Adaptive and Maladaptive Cardiac Hypertrophy: What Is the Effective Role of Heat Shock Transcription Factor 1? Circ. Res., February 16, 2007; 100(3): e45 - e46. [Full Text] [PDF] |
||||
![]() |
C. Weytjens, B. Cosyns, J. D'hooge, C. Gallez, S. Droogmans, T. Lahoute, P. Franken, and G. Van Camp Doppler myocardial imaging in adult male rats: Reference values and reproducibility of velocity and deformation parameters Eur J Echocardiogr, December 1, 2006; 7(6): 411 - 417. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. G. Neilan, D. S. Jassal, T. M. Perez-Sanz, M. J. Raher, A. D. Pradhan, E. S. Buys, F. Ichinose, D. B. Bayne, E. F. Halpern, A. E. Weyman, et al. Tissue Doppler imaging predicts left ventricular dysfunction and mortality in a murine model of cardiac injury Eur. Heart J., August 1, 2006; 27(15): 1868 - 1875. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Weidemann and J. M. Strotmann Detection of subclinical LV dysfunction by tissue Doppler imaging Eur. Heart J., August 1, 2006; 27(15): 1771 - 1772. [Full Text] [PDF] |
||||
![]() |
B. D. Hoit Echocardiographic Characterization of the Cardiovascular Phenotype in Rodent Models Toxicol Pathol, January 1, 2006; 34(1): 105 - 110. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2005 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |