Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2005;111:2326-2329
Published online before print April 25, 2005, doi: 10.1161/01.CIR.0000164271.01172.1A
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
111/18/2326    most recent
01.CIR.0000164271.01172.1Av1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sousa, J. E.
Right arrow Articles by Sousa, A. G.M.R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sousa, J. E.
Right arrow Articles by Sousa, A. G.M.R.
Related Collections
Right arrow Catheter-based coronary interventions: stents

(Circulation. 2005;111:2326-2329.)
© 2005 American Heart Association, Inc.


Interventional Cardiology

Four-Year Angiographic and Intravascular Ultrasound Follow-Up of Patients Treated With Sirolimus-Eluting Stents

J. Eduardo Sousa, MD, PhD; Marco A. Costa, MD, PhD; Alexandre Abizaid, MD, PhD; Fausto Feres, MD, PhD; Ana C. Seixas, MD; Luiz F. Tanajura, MD, PhD; Luiz A. Mattos, MD, PhD; Robert Falotico, PhD; Judith Jaeger, BA; Jeffrey J. Popma, MD; Patrick W. Serruys, MD, PhD; Amanda G.M.R. Sousa, MD, PhD

From Institute Dante Pazzanese of Cardiology (J.E.S., A.A., F.F., A.C.S., L.F.T., L.A.M., A.G.M.R.S.), São Paulo, Brazil; University of Florida, Shands-Jacksonville (M.A.C.), Jacksonville, Fla; Cordis, a Johnson & Johnson Company (R.F., J.J.), Warren, NJ; Brigham and Women’s Hospital (J.J.P.), Boston, Mass; and Thoraxcenter, Dijkzigt University Hospital (P.W.S.), Rotterdam, the Netherlands.

Correspondence to Professor J. Eduardo Sousa, MD, PhD, Institute Dante Pazzanese of Cardiology, Avenida Dr Dante Pazzanese, 500—Ibirapuera, 04012180, São Paulo, Brazil.

Received June 15, 2004; de novo received January 17, 2005; accepted January 21, 2005.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background— Despite the proven superiority of sirolimus-eluting stents (SESs) compared with bare stents in the first year after implantation, long-term outcomes of patients treated with these novel devices remain unknown. Our goal was to evaluate the clinical, angiographic, and intravascular ultrasound (IVUS) outcomes of patients treated with SESs 4 years after implantation.

Methods and Results— The study included 30 patients treated with sirolimus-eluting Bx Velocity stenting (slow release [SR; n=15] and fast release [FR; n=15]). Twenty-six patients underwent 4-year angiographic and IVUS follow-up and had matched assessments at all time points (index and 4-, 12-, 24-, and 48-month follow-up). One death occurred during the study period in a patient with a patent SES. There were no target-vessel revascularizations or thromboses between 2- and 4-year follow-up examinations. There was no stent thrombosis, target-lesion revascularization, death, or myocardial infarction in the SR group up to 4 years. Cumulative event-free survival rate was 87% for the total population (80% in the FR group and 93% in the SR group). In-stent late loss was slightly greater in the FR group (0.41±0.49 mm) than the SR group (0.09±0.23) after 4 years. One patient in the FR group had a 52% in-stent restenosis lesion. Percent neointimal hyperplasia volume, as detected by IVUS, remained minimal after 4 years (FR=9.1% and SR=5.7%).

Conclusions— This study confirms the longevity of the optimal outcomes observed in patients treated with sirolimus-eluting Bx Velocity stents 4 years after implantation. In-stent lumen dimensions remained essentially unchanged at 4-year follow-up, particularly in the population treated with the currently available SES (SR formulation).


Key Words: angiography • restenosis • stents


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Drug-eluting stent (DES) implantation is rapidly becoming the prime revascularization strategy for obstructive coronary artery disease because of reduced incidence of in-stent restenosis.1–3 Despite much enthusiasm, only a few DES devices have proven clinical effectiveness, and long-term data are lacking.

Most bioactive agents of DESs alter cell cycle division and have unpredictable long-term effects in the vessel wall.4 These cellular effects, which may resemble the mechanism of action of radiation therapy, have raised concerns about the safety of the DES beyond the initial years after implantation. In addition, nonbiodegradable polymer coatings, as well as residual medication in some devices, remain on the stent surface in close contact with arterial wall structures and represent a potential source for late inflammation, restenosis, or other side effects. The present study provides a unique opportunity to evaluate clinical, angiographic, and intravascular ultrasound (IVUS) outcomes of patients treated with sirolimus-eluting stents (SESs) 4 years after implantation.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
The study sample and study protocol have been described previously.1 In brief, 30 consecutive patients were implanted with a single sirolimus-eluting Bx Velocity stent from December 1999 to February 2000. Each stent contained a standard concentration of sirolimus per unit of metal surface area (140 µg of sirolimus/cm2). Fifteen patients received a fast-release (FR, <15-day drug release) SES, and 15 received a slow-release (SR, ≥28-day drug release) SES. All stents were 18 mm long and 3.0 to 3.5 mm in diameter. Patients received aspirin (325 mg/d, indefinitely) started at least 12 hours before the procedure and a 300-mg loading dose of clopidogrel immediately after stent implantation and 75 mg/d for 60 days. All patients had 4-month and 1-, 2-, and 4-year angiographic and IVUS follow-up scheduled per protocol. The Medical Ethics Committee at Institute Dante Pazzanese approved the protocol, and each patient provided informed consent.

Quantitative Measurements
Quantitative coronary angiography and IVUS imaging were performed after bolus infusion of intracoronary nitrates during the index procedure and at follow-up assessments. IVUS images were acquired with a motorized pullback at a constant speed of 0.5 mm/s. Quantitative angiographic and volumetric IVUS analyses were performed by independent core laboratories. Two coronary segments were subjected to coronary angiography: (1) in-stent and (2) in-lesion segments. The in-stent analysis encompassed only the 18-mm-long segment covered by the stent. The in-lesion segment was defined as the stent plus 5 mm proximal and 5 mm distal to the edge or the nearest side branch. In-stent and in-lesion restenosis were defined as ≥50% diameter stenosis (DS) at follow-up within the stent and target lesion, respectively. Minimal lumen diameter and percent DS were measured for each segment. In-stent late lumen loss was calculated as postprocedural minimal lumen diameter minus follow-up minimal lumen diameter. Intimal hyperplasia volume was calculated as stent volume minus luminal volume. Percent intimal hyperplasia was defined as intimal hyperplasia volume divided by stent volume.

Statistical Analysis
Continuous variables are expressed as mean±SD. Comparisons between the same measurements at different time points were performed with a 2-tailed paired t test. Comparisons between groups were performed with an unpaired Student t test. A probability value <0.05 was considered statistically significant. SYSTAT 11 software (Systat Software Inc) was used.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Baseline characteristics were similar between both the FR and SR groups, as reported previously.

Clinical Data
The overall incidence of major adverse cardiovascular events was 13% for the total population, 20% in the FR group, and 7% in the SR group. Survival rate was 97% (29/30) at 4-year follow-up. One patient in the FR group who had been treated in the right coronary artery died at 49-month follow-up. This patient underwent aortic and mitral valve replacement without complications 3 years after SES implantation and had severe left ventricular dysfunction. He had a cardiac arrest out of the hospital in January 2004; he was resuscitated but had severe cerebral damage. Postarrest angiography and IVUS, which coincided with the 4-year follow-up assessment, revealed no neointimal hyperplasia. The patient developed brain death and subsequently died. Necropsy, as reported previously,5 revealed a well-healed stented segment with >95% of the stent surface endothelialized as demonstrated by scanning electron microscopy. Approximately 75% of the stent struts were covered by a thin, type I collagen-rich neointima that contained smooth muscle cells.

There were 3 target-vessel revascularizations, which included 2 target-lesion revascularizations and 1 non-target-lesion revascularization, as reported previously.1 There were no target-vessel revascularizations or thromboses between 2- and 4-year follow-up. There were no stent thromboses, target-lesion revascularizations, deaths, or myocardial infarctions in the SR group up to 4 years. There was no aneurysm formation on angiography.

Angiographic and IVUS Data
Angiographic and IVUS imaging were performed in 26 patients at 4-year follow-up. Four patients did not undergo 4-year follow-up assessment: 3 had target-vessel revascularization before scheduled follow-up angiography, and 1 asymptomatic patient refused repeated angiography.

Only 1 patient (FR group) developed restenosis at 4 years. This patient had stenosis progression from 10% DS at 2 years to 52% DS at 4-year follow-up. Cumulative distributions of minimal lumen diameter at postprocedural, 2-year, and 4-year follow-up are shown in Figure 1. Net late loss was >0.5 mm in 7 patients. Of these, 6 patients were in the FR group, whereas only 1 patient with 0.51-mm late lumen loss was treated with the SR formulation. No other patient treated with an SR SES had ≥0.34 mm of late loss at 4-year follow-up (Figure 2).



View larger version (22K):
[in this window]
[in a new window]
 
Figure 1. In-stent minimal lumen diameter (MLD) over 4 years. Angiography was performed at postprocedural, 2-year, and 4-year follow-up.



View larger version (113K):
[in this window]
[in a new window]
 
Figure 2. Angiography shows lesion in proximal portion of left descending coronary artery (white arrow), which was treated with implantation of sirolimus-coated BX-Velocity stent (top right). Lumen dimensions remained unchanged at 4-, 12-, 24-, and 48-month follow-up. Pre indicates before procedure; Post, after procedure.

In the FR group, late loss progression averaged {approx}0.1 mm/y, totaling 0.4 mm at 4 years after implantation. In the SR group, a triphasic pattern of late loss was observed. Lumen loss was observed between postprocedural and 1-year follow-up and between 2- and 4-year follow-up, but lumen gain was noted between the 1- and 2-year follow-up examinations. As a result, the mean net late loss after 4 years was only 0.09 mm. Between 2 to 4 years, lumen loss was similar between the FR and SR groups. The temporal progression of late loss is shown in Table 1.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Temporal Evolution of In-Stent Late Loss Over 4-Year Follow-Up

IVUS volumetric data are reported in Table 2. There were no changes in vessel volume or media plus plaque volume behind the stent between postprocedural and 4-year follow-up.


View this table:
[in this window]
[in a new window]
 
TABLE 2. IVUS Volumetric Data at 4-Year Follow-Up


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
The present report confirms the longevity of the optimal results of the SES in a small number of patients and eases most concerns about the potential late toxicity of this device, particularly in patients treated with the SR SES, which is the same as the commercially available Cypher stent. There were no deaths, myocardial infarctions, thromboses, or target-lesion revascularizations in the SR group after 4 years. Neointimal proliferation remained minimal in both groups.

There was a steady progression of lumen loss at a low rate of 0.1 mm/y in the FR group. Lumen loss in patients treated with the SR SES was virtually absent (0.09 mm on average) 4 years after implantation. Indeed, this population experienced lumen gain between 1- and 2-year follow-up (Table 1). Similar patterns of lumen dimension variations, with an early restenosis phase at 6 months and an intermediate regression phase between from 6 and 36 months, followed by a late renarrowing phase beyond 4 years, were observed after implantation of Palmaz-Schatz stents.6

Although the pattern of lumen loss over time may appear similar between bare stents and the SR SES, there are still significant differences between the late angiographic outcomes of both devices. Unlike bare metal stents, which showed a 0.45-mm late lumen loss between 3- and ≥4-year follow-up angiography,6 changes in lumen dimensions after SR SES implantation were minimal.

Furthermore, an SD of late lumen loss in the SR group of only ±0.23 mm suggests that the angiographic results were reproducible among the patient population. Other stent studies, including some DES trials,7–9 have reported broader SDs for late lumen loss, which may reflect a high variability of the restenotic process among the study populations. A recent study (P. Lemos, MD, unpublished data, 2004) suggested that the pattern of late loss after SES implantation has an atypical statistical distribution, which is skewed to the right, with most measurements showing lower values than seen with bare stents. Another hypothesis is the possibility of a biological all-or-none response of restenosis, which may explain the presence of very focal lesions adjacent to a stent segment, with no intimal hyperplasia observed in patients who develop restenosis after SES.10

As already noted at 2-year follow-up,1 patients in the SR group appeared to have superior outcomes compared with the FR population. These results may highlight the importance of drug-release kinetics for the long-term success of the DES4 and the need for long-term follow-up assessments in DES studies. The present study was not designed to compare the 2 formulations of SESs, and definitive conclusions should not be drawn from the present data. Whether drug release for at least 4 weeks after implantation is a requirement for prolonged antirestenosis protection remains to be determined.


*    Acknowledgments
 
An institutional grant was given by Cordis, a Johnson & Johnson Company, Miami Lakes, Fla. We thank Dr Dennis Donohoe for his careful review of the manuscript and Dr Robert Percy for his statistical assistance.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 
1. Sousa JE, Costa MA, Sousa AG, Abizaid AC, Seicas AC, Abizaid AS, Feres F, Mattos LA, Falotico R, Jaeger J, Popma JJ, Serruys PW. Two-year angiographic and intravascular ultrasound follow-up after implantation of sirolimus-eluting stents in human coronary arteries. Circulation. 2003; 107: 381–383.[Abstract/Free Full Text]

2. Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnar F, Falotico R; RAVEL Study Group. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002; 346: 1773–1780.[Abstract/Free Full Text]

3. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE; SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003; 349: 1315–1323.[Abstract/Free Full Text]

4. Sousa JE, Serruys PW, Costa MA. New frontiers in cardiology: drug-eluting stents: part I. Circulation. 2003; 107: 2274–2279.[Free Full Text]

5. Sousa JE, Costa MA, Farb A, Abizaid A, Sousa A, Seixas AC, da Silva LM, Feres F, Pinto I, Mattos LA, Virmani R. Vascular healing 4 years after the implantation of sirolimus-eluting stent in humans: a histopathological examination. Circulation. 2004; 110: e5–e6.[Free Full Text]

6. Kimura T, Abe K, Shizuta S, Odashiro K, Yoshida Y, Sakai K, Kaitani K, Inoue K, Nakagawa Y, Yokoi H, Iwabuchi M, Hamasaki N, Nosaka H, Nobuyoshi M. Long-term clinical and angiographic follow-up after coronary stent placement in native coronary arteries. Circulation. 2002; 105: 2986–2991.[Abstract/Free Full Text]

7. Serruys PW, de Jaegere P, Kiemeneij F, Macaya C, Rutsch W, Heyndrickx G, Emanuelsson H, Marco J, Legrand V, Materne P; Benestent Study Group. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med. 1994; 331: 489–495.[Abstract/Free Full Text]

8. Abizaid A, Albertal M, Costa MA, Abizaid AS, Staico R, Feres F, Mattos LA, Sousa AG, Moses J, Kipshidize N, Roubin GS, Mehran R, New G, Leon MB, Sousa JE. First human experience with the 17-beta-estradiol-eluting stent: the Estrogen And Stents To Eliminate Restenosis (EASTER) trial. J Am Coll Cardiol. 2004; 43: 1118–1121.[Abstract/Free Full Text]

9. Colombo A, Drzewiecki J, Banning A, Grube E, Hauptmann K, Silber S, Dudek D, Fort S, Schiele F, Zmudka K, Guagliumi G, Russell ME; TAXUS II Study Group. Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation. 2003; 108: 788–794.[Abstract/Free Full Text]

10. Lemos PA, Saia F, Ligthart JM, Arampatzis CA, Sianos G, Tanabe K, Hoye A, Degertekin M, Daemen J, McFadden E, Hofma S, Smits PC, de Feyter P, van der Giessen WJ, van Domburg RT, Serruys PW. Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases. Circulation. 2003; 108: 257–260.[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
HeartHome page
R A Byrne, S Kufner, K Tiroch, S Massberg, K-L Laugwitz, A Birkmeier, S Schulz, J Mehilli, and for the Intracoronary Stenting and Angiographic Re
Randomised trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis: 2-year follow-up results
Heart, September 15, 2009; 95(18): 1489 - 1494.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
R. A. Byrne, R. Iijima, J. Mehilli, S. Pinieck, O. Bruskina, A. Schomig, and A. Kastrati
Durability of Antirestenotic Efficacy in Drug-Eluting Stents With and Without Permanent Polymer
J. Am. Coll. Cardiol. Intv., April 1, 2009; 2(4): 291 - 299.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. O. Jensen, M. Maeng, P. Thayssen, E. H. Christiansen, K. N. Hansen, A. Galloe, H. Kelbaek, J. F. Lassen, and L. Thuesen
Neointimal hyperplasia after sirolimus-eluting and paclitaxel-eluting stent implantation in diabetic patients: The Randomized Diabetes and Drug-Eluting Stent (DiabeDES) Intravascular Ultrasound Trial
Eur. Heart J., November 2, 2008; 29(22): 2733 - 2741.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. Kelbaek, L. Klovgaard, S. Helqvist, J. F. Lassen, L. R. Krusell, T. Engstrom, H. E. Botker, E. Jorgensen, K. Saunamaki, S. Aljabbari, et al.
Long-Term Outcome in Patients Treated With Sirolimus-Eluting Stents in Complex Coronary Artery Lesions: 3-Year Results of the SCANDSTENT (Stenting Coronary Arteries in Non-Stress/Benestent Disease) Trial
J. Am. Coll. Cardiol., May 27, 2008; 51(21): 2011 - 2016.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. J. Applegate, M. T. Sacrinty, M. A. Kutcher, R. M. Santos, S. K. Gandhi, T. T. Baki, and W. C. Little
"Off-label" stent therapy 2-year comparison of drug-eluting versus bare-metal stents.
J. Am. Coll. Cardiol., February 12, 2008; 51(6): 607 - 614.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
E. Grube, K. D. Dawkins, G. Guagliumi, A. P. Banning, K. Zmudka, A. Colombo, L. Thuesen, K. Hauptman, J. Marco, W. Wijns, et al.
TAXUS VI 2-year follow-up: randomized comparison of polymer-based paclitaxel-eluting with bare metal stents for treatment of long, complex lesions
Eur. Heart J., November 1, 2007; 28(21): 2578 - 2582.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
G. J. Wilson, J. E. Polovick, B. A. Huibregtse, and B. C. Poff
Overlapping paclitaxel-eluting stents: Long-term effects in a porcine coronary artery model
Cardiovasc Res, November 1, 2007; 76(2): 361 - 372.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Daemen and P. W. Serruys
Drug-Eluting Stent Update 2007: Part II: Unsettled Issues
Circulation, August 21, 2007; 116(8): 961 - 968.
[Full Text] [PDF]


Home page
CirculationHome page
M. Awata, J.-i. Kotani, M. Uematsu, T. Morozumi, T. Watanabe, T. Onishi, O. Iida, F. Sera, S. Nanto, M. Hori, et al.
Serial Angioscopic Evidence of Incomplete Neointimal Coverage After Sirolimus-Eluting Stent Implantation: Comparison With Bare-Metal Stents
Circulation, August 21, 2007; 116(8): 910 - 916.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Marzocchi, F. Saia, G. Piovaccari, A. Manari, E. Aurier, A. Benassi, A. Cremonesi, G. Percoco, E. Varani, P. Magnavacchi, et al.
Long-Term Safety and Efficacy of Drug-Eluting Stents: Two-Year Results of the REAL (REgistro AngiopLastiche dell'Emilia Romagna) Multicenter Registry
Circulation, June 26, 2007; 115(25): 3181 - 3188.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
G. J. Murphy, T. W. Johnson, M. H. Chamberlain, S. I. Rizvi, M. Wyatt, S. J. George, G. D. Angelini, K. R. Karsch, M. Oberhoff, and A. C. Newby
Short- and long-term effects of cytochalasin D, paclitaxel and rapamycin on wall thickening in experimental porcine vein grafts
Cardiovasc Res, February 1, 2007; 73(3): 607 - 617.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Elezi, A. Dibra, J. Mehilli, J. Pache, R. Wessely, A. Schomig, and A. Kastrati
Vessel Size and Outcome After Coronary Drug-Eluting Stent Placement: Results From a Large Cohort of Patients Treated With Sirolimus- or Paclitaxel-Eluting Stents
J. Am. Coll. Cardiol., October 3, 2006; 48(7): 1304 - 1309.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
R. Gupta, F. Al-Ali, A. J. Thomas, M. B. Horowitz, T. Barrow, N. A. Vora, K. Uchino, M. D. Hammer, L. R. Wechsler, and T. G. Jovin
Safety, Feasibility, and Short-Term Follow-Up of Drug-Eluting Stent Placement in the Intracranial and Extracranial Circulation
Stroke, October 1, 2006; 37(10): 2562 - 2566.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. Takano, T. Ohba, S. Inami, K. Seimiya, S. Sakai, and K. Mizuno
Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after a 6-month implantation
Eur. Heart J., September 2, 2006; 27(18): 2189 - 2195.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. S. Mintz and N. J. Weissman
Intravascular Ultrasound in the Drug-Eluting Stent Era
J. Am. Coll. Cardiol., August 1, 2006; 48(3): 421 - 429.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R Waksman, I M Leitch, J Roessler, H Yazdi, R Seabron, F Tio, R W Scott, R I Grove, S Rychnovsky, B Robinson, et al.
Intracoronary photodynamic therapy reduces neointimal growth without suppressing re-endothelialisation in a porcine model
Heart, August 1, 2006; 92(8): 1138 - 1144.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. R. Dixon, C. L. Grines, and W. W. O'Neill
The Year in Interventional Cardiology
J. Am. Coll. Cardiol., April 18, 2006; 47(8): 1689 - 1706.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Valgimigli, P. Malagutti, C. A.G. van Mieghem, S. Vaina, J. M. Ligthart, G. Sianos, and P. W. Serruys
Persistence of Neointimal Growth 12 Months After Intervention and Occurrence of Delayed Restenosis in Patients With Left Main Coronary Artery Disease Treated With Drug-Eluting Stents
J. Am. Coll. Cardiol., April 4, 2006; 47(7): 1491 - 1494.
[Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
P. Roy-Chaudhury, V. P. Sukhatme, and A. K. Cheung
Hemodialysis Vascular Access Dysfunction: A Cellular and Molecular Viewpoint
J. Am. Soc. Nephrol., April 1, 2006; 17(4): 1112 - 1127.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. S. Lee, N. Kapoor, F. Jamal, L. Czer, J. Aragon, J. Forrester, S. Kar, S. Dohad, R. Kass, N. Eigler, et al.
Comparison of Coronary Artery Bypass Surgery With Percutaneous Coronary Intervention With Drug-Eluting Stents for Unprotected Left Main Coronary Artery Disease
J. Am. Coll. Cardiol., February 21, 2006; 47(4): 864 - 870.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. J. Price, E. Cristea, N. Sawhney, J. A. Kao, J. W. Moses, M. B. Leon, R. A. Costa, A. J. Lansky, and P. S. Teirstein
Serial Angiographic Follow-Up of Sirolimus-Eluting Stents for Unprotected Left Main Coronary Artery Revascularization
J. Am. Coll. Cardiol., February 21, 2006; 47(4): 871 - 877.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Wessely, A. Schomig, and A. Kastrati
Sirolimus and Paclitaxel on Polymer-Based Drug-Eluting Stents: Similar But Different
J. Am. Coll. Cardiol., February 21, 2006; 47(4): 708 - 714.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
P. W. Serruys, M. J.B. Kutryk, and A. T.L. Ong
Coronary-Artery Stents
N. Engl. J. Med., February 2, 2006; 354(5): 483 - 495.
[Full Text] [PDF]


Home page
CirculationHome page
J. Aoki, A. Colombo, D. Dudek, A. P. Banning, J. Drzewiecki, K. Zmudka, F. Schiele, M. E. Russell, J. Koglin, P. W. Serruys, et al.
Peristent Remodeling and Neointimal Suppression 2 Years After Polymer-Based, Paclitaxel-Eluting Stent Implantation: Insights From Serial Intravascular Ultrasound Analysis in the TAXUS II Study
Circulation, December 20, 2005; 112(25): 3876 - 3883.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
111/18/2326    most recent
01.CIR.0000164271.01172.1Av1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sousa, J. E.
Right arrow Articles by Sousa, A. G.M.R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sousa, J. E.
Right arrow Articles by Sousa, A. G.M.R.
Related Collections
Right arrow Catheter-based coronary interventions: stents