(Circulation. 2004;110:II-115 II-122.)
© 2004 American Heart Association, Inc.
Surgery for Valvular Heart Disease |
From the Department of Cardiothoracic Surgery (F.R., F.L., K.B.H., F.A.T., M.K.Z., A.C., G.T.D., N.B.I., C.M.) and Division of Cardiovascular Medicine (D.L.), Stanford University School of Medicine, Stanford, Calif; Department of Medicine (J.W.C.), University of California San Diego, La Jolla, Calif; Department of Biomedical Engineering (J.C.C.), Texas A&M University, College Station, Tex; Laboratory of Cardiovascular Physiology and Biophysics (G.T.D., N.B.I.), Palo Alto Medical Foundation Research Institute, Palo Alto, Calif.
Correspondence to D. Craig Miller, Department of Cardiothoracic Surgery, Falk Cardiovascular Research Center, Stanford University School of Medicine, Stanford, CA 94305-5247. E-mail dcm{at}stanford.edu
| Abstract |
|---|
|
|
|---|
Methods and Results Eight sheep had radiopaque markers implanted to silhouette the LV, annulus, and papillary muscles (PMs); 3 transmural bead columns were inserted into the mid-lateral wall between the PMs. The strut chordae were encircled with exteriorized wire snares. Three-dimensional marker images and hemodynamic data were acquired before and after chordal cutting. Preload recruitable stroke work (PRSW) and end-systolic elastance (Ees) were calculated to assess global LV systolic function (n=7). Transmural strains were measured from bead displacements (n=4). Chordal cutting caused global LV dysfunction: Ees (1.48±1.12 versus 0.98±1.30 mm Hg/mL, P=0.04) and PRSW (69±16 versus 60±15 mm Hg, P=0.03) decreased. Although heart rate and time from ED to ES were unchanged, time of mid-ejection was delayed (125±18 versus 136±19 ms, P=0.01). Globally, the LV apex and posterior PM tip were displaced away from the fibrous annulus and LV base-apex length increased at end-diastole and end-systole (all +1 mm, P<0.05). Locally, subendocardial end-diastolic strains occurred: Longitudinal strain (E22) 0.030±0.013 and radial thickening (E33) 0.081±0.041 (both P<0.05 versus zero). Subendocardial systolic shear strains were also perturbed: Circumferential-longitudinal "micro-torsion" (E12) (0.099±0.035 versus 0.075±0.025) and circumferential radial shear (E13) (0.084±0.023 versus 0.039±0.008, both P<0.05).
Conclusion Cutting second-order chords altered LV geometry, remodeled the myocardium between the PMs, perturbed local systolic strain patterns affecting micro-torsion and wall-thickening, and caused global systolic dysfunction, demonstrating the importance of these chordae for LV structure and function.
Key Words: contractility mechanics mitral valve regurgitation structure
| Introduction |
|---|
|
|
|---|
Although the importance of chordal preservation for LV systolic function during valve replacement is widely accepted, the selective roles of first-order versus second-order chordae have only recently been explored. In a study of isolated porcine hearts, Obadia et al showed that transection of the first-order chordae resulted in leaflet prolapse and mitral regurgitation (MR) without affecting circumferential segmental shortening along the mid-anterolateral LV wall. Conversely, cutting the second-order chordae decreased fractional segment shortening and forward aortic flow but did not result in MR.8 These authors first suggested different roles for the first-order and second-order chordae, with the first-order chordae preventing leaflet prolapse and the second-order chordae involved in ventricular mechanics. Kunzelman et al reported differences in first-order and second-order chordae material properties, which may reflect these specific roles: First-order chordae are stiffer (ie, less extensible), consistent with preventing leaflet prolapse, whereas the larger, more elastic second-order chordae may mediate valvularventricular interaction.9 Nonetheless, cutting second-order chordae has recently been proposed as a therapeutic intervention for patients with ischemic MR to reduce leaflet apical tethering and improve leaflet coaptation,10,11 which calls for a more complete understanding of the role of the second-order chordae in ventricular mechanics. If these chordae are important for LV systolic function, then they may be even more so in the setting of ischemic MR in hearts that are already impaired.
Although we believe that the second-order chordae are important for valvularventricular interaction, debate exists because reports from a previous experiment in this laboratory failed to demonstrate changes in either load-dependent or load-independent indices of global LV function after transection of second-order chordae,12,13 and Messas et al observed no change in LV ejection fraction after chordal cutting.10,11 Alterations in regional LV systolic dysfunction (decreased fractional area shortening and decreased regional preload recruitable stroke work) adjacent to the PM insertion sites, however, have been observed.13 We sought to clarify these issues and address the limitations inherent in our earlier experiment12,13 by measuring global LV function and transmural systolic LV wall mechanics before and after transection of the second-order chordae.
| Materials and Methods |
|---|
|
|
|---|
Surgical Preparation
Twenty-two Dorsett hybrid sheep (74±10 kg) were premedicated with ketamine (25 mg/kg intramuscularly). Anesthesia was induced with sodium thiopental (6.8 mg/kg intramuscularly) and maintained with inhalational isoflurane (1.5% to 2.2%). Working through a left thoracotomy, epicardial echocardiography was used to identify a region of the mid-lateral LV wall between the PMs at the equatorial level. After end-diastolic wall depth was measured (10±1 mm), 3 transmural columns of 3 lead beads each (0.7-mm diameter) were inserted between the PMs spaced evenly from subendocardium to subepicardium using a similar method as originally described by Waldman et al.14 A 1-cm-thick Plexiglas template was sutured to the mid-lateral wall 49±4% of the distance from base to apex. The 3 bead columns were inserted through predrilled holes in the Plexiglas template using a custom-designed needle trocar. The template was then removed and 3 1.7-mm beads were sutured to the epicardial surface at the entry hole of each implanted column (Figure 1). Twelve radiopaque tantalum helical markers (outer diameter, 1.3 mm; length, 1.5 to 3.0 mm) were then inserted in the subepicardium to silhouette the LV along 4 equally spaced longitudinal meridians defining anterior, lateral, posterior, and septal walls at basal, equatorial, and apical levels; a single marker was placed at the LV apex (1 to 13; Figure 1). Pneumatic occluders (In Vivo Metric Systems) were placed around the inferior vena cava (to provide transient preload reduction) and around the mid-circumflex coronary artery distal to the first obtuse marginal branch (to induce transient posterolateral ischemia for the purposes of another analysis.15
|
On cardiopulmonary bypass (CPB) using cardioplegic arrest and working through a left atriotomy, 8 additional tantalum markers were sutured around the mitral annulus (MA) at the mid-septal annulus (the "saddle horn;" 14), left fibrous trigone (LFT; 15) and right (21) fibrous trigone (RFT), anterior (16) and posterior (20) commissures, and equidistantly around the lateral annulus (17, 18, and 19, respectively; Figure 1). The largest second-order chorda from each PM inserting into the anterior mitral leaflet (AML) belly was identified (ie, the 2 most central "strut" chordae), and wire snares (insulated except where they encircled the chordae) were secured around these chordae and exteriorized through the LV wall. Extreme care was taken to ensure that the snares did not inadvertently trap any first-order chordae. Markers were placed on each PM tip near the origin of the strut chordae (22 and 23; Figure 1). A micromanometer-tipped catheter (Millar SPC-500; Millar Instruments, Inc) was inserted through the LV apex to monitor LV pressure (LVP). Animals were weaned from CPB and received intravenous magnesium (3 g), lidocaine (100 mg), and bretylium (50 mg) before transfer as prophylaxis against rhythm disturbances. Epicardial color Doppler echocardiography confirmed normal leaflet motion and valvular competence.
Experimental Protocol
Immediately postoperatively, animals were transferred to the catheterization laboratory and studied with the chest open; maintenance anesthesia was continued with inhalational isoflurane (1.5% to 2.2%). Sequences of biplane videofluoroscopic and hemodynamic data were acquired over a physiological range of LV filling volumes during transient vena caval occlusion with animals in the right lateral decubitus position and ventilation briefly arrested at end-expiration (to prevent respiratory variation). Before baseline data acquisition, transient posterolateral ischemia (53±49 seconds) was induced by mid-circumflex coronary artery occlusion for another experiment.15 After this ischemic interval, the animals were allowed to stabilize for 5 minutes. Baseline data were then acquired with the second-order chords intact (pre-cut). Before chordal cutting, animals received an additional 100 mg of lidocaine (intravenous) as prophylaxis against rhythm disturbances. The strut chords were then immediately divided by passing electrocautery RF current through the externalized wire snares (cut). After chordal cutting, the animals were allowed to stabilize for 5 minutes, and then data were acquired (postcut). Simultaneous transesophageal color Doppler echocardiography allowed evaluation of the degree of MR before and after cut by an experienced echocardiographer (D.L.) on a 0 to 4+ scale (none, mild, moderate, moderatesevere, and severe).
Data Acquisition
A Philips Optimus 2000 biplane Lateral ARC 2/poly DIAGNOST C2 system (Philips Medical Systems) was used to record videofluoroscopic images at 60-Hz. Two-dimensional images from the 2 x-ray views were digitized using custom software.16 These data were merged to yield 3-dimensional coordinates for each radiopaque marker every 16.7 ms, the accuracy of which is 0.1±0.3 mm compared with known marker-to-marker 3-dimensional lengths.17 Analog LVP and ECG signals were digitized simultaneously and recorded on videotape along with marker images during data acquisition.
Data Analysis
Of 22 animals entered into this experiment, 8 had successful transection of second-order strut chordae without damage to first-order chordae or AML and without ventricular fibrillation during the cutting attempt. These 8 animals comprise the present study group. Six other animals had inadvertent damage to first-order chords (which was evident immediately on echocardiography and confirmed on necropsy), and 8 other sheep fibrillated during the cutting attempt; thus, 14 animals were excluded.
End-diastole (ED) was defined as the time of maximum second derivative of LVP, corresponding with the frame immediately before the upstroke of LVP. End-systole (ES) was defined as the videofluoroscopic frame before the time of peak negative LV rate of pressure fall (dP/dtmax). Hemodynamic and marker-derived data from 3 consecutive steady-state beats in sinus rhythm were time-aligned at ED and averaged for each animal before (precut) and after (postcut) strut chord transection.
Instantaneous LV volume was calculated from LV and MA markers using multiple tetrahedra constructed from the marker coordinates and corrected for LV convexity.18 Although epicardial LV volume calculated in this manner overestimates true LV chamber volume (because it incorporates LV muscle mass), changes in this "epicardial" LV volume are an accurate measurement of the relative changes in LV chamber volume because LV muscle mass remains constant throughout the cardiac cycle.19 Stroke volume (SV) was calculated as the difference between end-diastolic LV volume (EDV) and end-systolic LV volume (ESV): SV = EDV ESV. Mid-ejection was defined at the time when one-half of stroke volume had been ejected.
In 7 of the 8 sheep with successful cut, satisfactory vena cava occlusions during data acquisition allowed calculation of load-independent indices of LV function, end-systolic elastance (Ees), and preload recruitable stroke work (PRSW).5 Three steady-state beats and 2 occlusion beats were analyzed for each animal.
The end-systolic pressure-volume relationship (ie, end-systolic elastance) was calculated to measure global LV systolic mechanics (contractility) as follows: LV end-systolic pressure (Pes) and volume (Ves) points were determined at the upper-left hand corner of the PV loop for each cardiac cycle analyzed during preload alteration (Figure 2a). By least-squares linear regression, a line was fitted to these points:
|
|
|
where Ees and Vo are the slope and volume axis intercept, respectively.20
Another load-insensitive measure of LV performance, PRSW, which incorporates both systolic and diastolic conditions, was determined by relating stroke work (SW) to EDV (Figure 2b). Stroke work was calculated as the integral of LV pressure (P) multiplied by change in volume (dV):
|
|
over each cardiac cycle for the steady-state and occlusion beats. PRSW was then obtained by linear regression of SW on EDV as:
|
|
where Mw and Vw are the slope and volume axis intercept, respectively, of the regression line.21
Distances at ED and ES were calculated for precut and postcut conditions using 3-dimenional marker coordinates. Without assumption of planar geometry, the centroid of 4 MA markers (ie, the saddle horn, anterior commissures, posterior commissures, and lateral MA markers; 14, 16, 20, and 18, respectively; Figure 1) was determined and LV longitudinal length was measured between the MA centroid and the apical marker. Similarly, individual distances between the LV apex and MA saddle horn, LFT, RFT, anterior commissures, posterior commissures, and lateral markers were calculated to assess changes in these lengths. Distances between the septal and lateral wall markers and between anterior and posterior wall markers were measured at annular, LV basal, equatorial, and apical levels (Figure 1) to determine changes in LV short-axis diameter. Distances between MA saddle horn and PM tips were also measured to assess changes in subvalvular geometry.
Successful placement of transmural bead-sets allowed quantification of 3-dimensional myocardial deformations of the mid-lateral region in 4 sheep. Because a boundary exists between the myocardial wall and the PMs which can be distinguished grossly and is also revealed in muscle fiber angle measurements,22 thereby rendering homogenous strain theory inappropriate at the PM border,23 care was taken to avoid the PMs during bead set insertion. For strain analysis, the LV long-axis was defined using the anterior basal marker (4; Figure 1) and the apical marker (1), similar to the LV long-axis originally described by Streeter.24 This long-axis and the 3 epicardial surface beads define a system of local cardiac coordinates aligned with the circumferential (X1), longitudinal (X2), and radial (X3) axes of the LV lateral wall. Because the local epicardial-tangent plane defines this coordinate system, wall curvature is taken into account. Using a least-squares method, a continuous polynomial position field was identified with quadratic dependence in X3 and bilinear in X1 and X2 with cubic Hermite interpolation in time using 5 equally spaced time nodes in the cardiac cycle with the nodal degrees of freedom of nodes 1 and 5 set equal because they both represent ED. After using the upstroke of the LVP to register each beat with respect to time, the degrees of freedom for this position field were averaged over 3 beats in the sense that parameters of this fit (for 1 cycle) were chosen to minimize error in fitting the 3 cycles of data. The position field defines the current position of the beads throughout the cardiac cycle as a function of their reference positions (defined at ED) and time from ED. The material gradient of this position field at a particular time is the local deformation gradient tensor (F) where Green strain (E) is calculated as:
|
|
where I is the identity tensor. In local cardiac coordinates [X1, X2, X3], the 3 normal strain components measure myocardial stretch or shortening along the circumferential (E11), longitudinal (E22), and radial (E33) cardiac axes. The 3 shear strains (E12, E13, and E23) represent angle changes between pairs of originally orthogonal coordinate axes. Strains were interpolated along the centroid of the bead columns at 1% increments of wall depth from the epicardium at ED. Echocardiographic measurement at the time of bead insertion demonstrating that the most subendocardial bead was consistently at 90% of wall depth (wall depth averaged 10±1 mm, and the depth of the deepest beads was 9±1 mm from the epicardial surface) allowed for interpolation (0% to 90%) and extrapolation (90% to 100%) of strains through the entire LV wall. The mean error of this method for transmural continuous strain error suggested by J.C.C., computed in cylindrical coordinates on a thick-walled incompressible cylinder undergoing inflation and stretch, torsional and tranverse shear, is 1.02% (range, 0.04% to 3.72% for the 6 tensor components) (K. Kindberg, unpublished data, 2004).
Because strain in the heart is heterogeneous with respect to wall depth, it is necessary to evaluate strain patterns at different depths independently; transmural strains at 20% (subepicardial), 50% (mid), and 80% (subendocardial) wall depth were selected for analysis. Changes in bead positions at ED postcut (deformed configuration) were compared with those from ED at baseline (precut, reference configuration) to assess changes in local transmural myocardial geometry at end-diastole (ie, end-diastolic strain), which describes changes in regional 3-dimensional geometry at ED associated with acute alterations in material properties between precut and postcut. Systolic strains were calculated by comparing bead positions at ES (deformed configuration) with ED (reference configuration) for each data run (3 beats per run) before and after cut.
All data are reported as mean±1 SD. End-diastolic strains were compared with zero using a 1-sample t test. Changes in hemodynamics, global geometry, and systolic strains at each depth were compared using Student t test for paired observations. The effect of chordal cutting on PRSW as related to the X-intercept of the linear regression (Vw) was also assessed using an analysis of covariance (ANCOVA) model. Degree of MR was compared using Wilcoxon signed-rank test for nonparametric observations. The level of significance was taken as P
0.05. P>0.05 but
0.10 was considered to be possibly significant and is stated as such.
| Results |
|---|
|
|
|---|
Before chordal cutting, trace to mild MR was detected; there was no change in the degree of MR after transection of the strut chordae (0.4±0.4 [precut] versus 0.6±0.4 [postcut]; p=NS). Not surprisingly, in the 6 animals with damaged first-order chordae, MR increased significantly (0.8±0.4 versus 2.5±1.2; P=0.03), underscoring the importance of primary chordae for valvular competence.
Systolic Temporal Dynamics and Hemodynamics
After chordal cutting, neither heart rate (111±16 versus 107±14 minutes1, P=0.14) nor time from ED to ES (271±40 versus and 273±41 ms, P=0.76) changed, but time from ED to mid-ejection was significantly delayed (125±18 versus 136±19 ms, P=0.01).
These altered systolic temporal dynamics were associated with global LV dysfunction as determined by load-independent indices (Table 1 and Figure 2). Systolic function, as estimated by the slope of the end-systolic pressure-volume relationship (Ees), declined 34% after chordal cutting (1.48±1.12 versus 0.98±1.30 mm Hg/mL, P=0.04). PRSW declined by 15% (69±16 versus 60±15 mm Hg, P=0.03); ANCOVA confirmed this significant effect of chordal cutting on PRSW (P=0.03). No load-dependent hemodynamic variable changed demonstrably (Table 1).
|
Global LV Geometry
Chordal cutting resulted in small, but significant, alterations in global LV geometry. Base-apex length increased both at ED (8.99±0.59 versus 9.06±0.59 cm, P=0.04) and ES (8.67±0.63 versus 8.74±0.61 cm, P=0.02), demonstrating that second-order chordae are load-bearing structures serving to maintain LV geometry. The LV apex was displaced away from the LFT at ED (9.52±0.59 versus 9.62±0.52 cm, P=0.02), and from both the RFT (8.46±0.59 versus 8.63±0.71 cm, P=0.07) and the saddle horn (9.34±0.71 versus 9.50±0.76 cm, P=0.02) at ES. No changes in the distances between LV apex and the commissures or the lateral annulus were observed. The posterior PM tip was also displaced away from the mitral saddle horn after chordal cutting both at ED (4.76±0.41 versus 4.86±0.44 cm, P=0.03) and ES (4.84±0.39 versus 4.96±0.46 cm, P=0.03); no anterior PM tip displacement occurred. In the LV short-axis, only septal-lateral diameter at the apical level increased after chordal cutting at ED (4.80±0.68 versus 4.89±0.57 cm, P=0.03), consistent with outward displacement of the posterior PM.
End-Diastolic Strains
The end-diastolic global LV geometric changes after chordal cutting paralleled alterations in local mid-lateral LV transmural wall deformations, as determined from analysis of the bead set. Table 2 summarizes the transmural end-diastolic strains after chordal cutting. Transection of the second-order chordae resulted in longitudinal lengthening (E22 strain) and radial wall-thickening (E33 strain) in the midwall and subendocardium. Longitudinalradial shear (E23) in the subepicardium and subendocardium also occurred.
|
Systolic Strains
Consistent with decreased LV systolic function and altered systolic temporal dynamics, changes in LV transmural systolic strains were also seen after chordal cutting (Table 3). Subepicardial and midwall circumferential shortening (E11) decreased significantly, as did subendocardial circumferentiallongitudinal shear (E12, ie, myocardial "micro-torsion"). Two components of subendocardial wall thickening also decreased: circumferentialradial shear (E13) decreased significantly and the reduction in radial strain (E33) approached statistical significance (P=0.08). Subendocardial longitudinal shortening strain (E22) increased. To illustrate these findings, subendocardial 3-dimensional cardiac strains throughout the cardiac cycle are shown in Figure 3.
|
|
| Discussion |
|---|
|
|
|---|
This current experiment corroborates the notion that second-order chordae are important for valvularventricular interaction and thus preservation of LV systolic pump function. Division of the anterior mitral leaflet second-order strut chordae resulted in deterioration of global LV systolic performance, as reflected by the 34% decline in Ees (end-systolic pressure-volume relationship slope). Analysis of PRSW (another load-insensitive measure of LV systolic performance that incorporates both systolic and diastolic information) showed that the SW-EDV relation was highly linear (Figure 2b) and decreased after chordal cutting, again reflecting reduced global pump function.5,21
The mechanisms responsible for second-order chordae valvular-ventricular interaction may be related to their importance in maintaining elliptical LV geometry and enhancing regional LV wall thickening. Our results demonstrate a link between the second-order chordae and LV structure and function, consistent with previously published works. In porcine studies, van Rijk-Zwikker et al25 found that the anterior leaflet strut chordae remain taut during the cardiac cycle, and Lomholt et al26 measured forces on the second-order chordae that were 3-fold higher than those on first-order chordae (0.7 N versus 0.2 N). From a functional viewpoint, these observations suggest that second-order chordae provide important connections between the cardiac endoskeleton (along the fibrous annulus) and the LV free wall.13 Collagen bundles have been identified in the anterior mitral leaflet radiating away from the strut chordae insertion points to the fibrous portion of the MA between the fibrous trigones.9 In the present experiment, cutting the second-order chordae perturbed global LV geometry. Baseapex LV length increased both at ED and ES, and displacement of the LV apex and PPM tip away from the fibrous annulus after chordal cutting supports the role of second-order chordae as important load-bearing structures. The change in apical displacement from the LFT at ED toward the RFT at ES may reflect contraction of the helically oriented myofibers during systole;24,27 this coupled with no change in the distances between the LV apex and the commissures or the lateral annulus caused the MA to "tilt" as the distance from the apex to the fibrous annulus increased. Such annular "tilting" has been linked with narrowing of the aorto-mitral angle after cutting the second-order chordae.28 Further, subvalvular displacement of only the posterior PM reflects the larger load on the second-order chord originating from the posterior PM than from the anterior PM (0.81±0.1 versus 0.52±0.08 N, P<0.01).13
The geometric perturbations accompanying chordal cutting also included local remodeling of the myocardium in the mid-lateral wall between the PMs. Analysis of end-diastolic strains demonstrated subendocardial and midwall elongation (E22) consistent with global LV baseapex lengthening (Table 2). Radial wall-thickening (E33 strain) at ED was also observed in the midwall and subendocardium, possibly reflecting local myocardial unloading in this region after chordal cutting. Longitudinalradial shear (E23) in the subepicardium and subendocardium may reflect the increased apical LV septallateral diameter at ED, which was measured between markers 5 and 11 (located immediately below the transmural bead set) (Figure 1).
These global and local LV geometric changes may underlie the alterations observed in transmural systolic strains, which provide a mechanism for the LV dysfunction and altered systolic temporal dynamics observed after chordal cutting. Subepicardial and midwall circumferential shortening (E11) decreased significantly, as did subendocardial circumferentiallongitudinal shear (E12, or myocardial "micro-torsion"), reflecting decreased local contractile function.29,30 Subendocardial circumferentialradial shear (E13), which is a component of wall thickening, also decreased significantly (Table 3 and Figure 3). Subendocardial radial strain (E33), another component of wall thickening, also tended to decrease and approached significance at end-systole (P=0.08), which can be appreciated in the bottom left panel of Figure 3. The increase in subendocardial longitudinal shortening strain (E22) may reflect increased preload stretch (increased baseapex length and local longitudinal lengthening at ED) and/or possible local myocardial unloading along the LV long-axis after chordal cutting.
The observations from the present study support earlier work from this laboratory showing regional LV systolic dysfunction at the PM insertion sites after transection of the second-order chordae.13 This previous experiment, however, was unable to detect a significant decline in global LV function (although such a trend was noted), probably because the previous experimental preparation involved a much more complex and longer surgical procedure in which the strut chordae were transected intraoperatively and then reapproximated with an interposed strain gauge before "control" data were obtained.12,13 Global hemodynamic data from these earlier experiments comparing "control" and postcut conditions must therefore be interpreted cautiously, because "control" data from these earlier studies were acquired after a very long aortic cross-clamp time and after the second-order chordae had already been cut and reapproximated.12,13 The inability to detect a statistical difference in these earlier studies may also have just represented a type II (or ß) statistical error because of the small numbers.31
Conversely, Messas et al did not observe a decline in LV ejection fraction after cutting the second-order chordae.10,11 This may be because ejection fraction is a load-dependent index of LV systolic function and LV volume status was purposefully adjusted in their experiment after intraoperative chordal cutting to restore pre-CPB (and prechordal cutting) cardiac output and LV pressures.10,11 In the present experiment, we used PRSW and Ees (load-independent indexes of global LV systolic function) and the experimental design allowed for paired, sequential comparisons between precut and postcut conditions in the same animals without confounding factors such as a procedure on CPB or preload alterations between study conditions. After chordal cutting, both PRSW and Ees decreased significantly (Table 1), reinforcing the trends observed in our earlier experiment.12,13 A decrease in load-dependent LV +dP/dtmax was also observed but failed to reach statistical significance (P=0.16). Although this lack of difference in a load-dependent measure of LV function after chordal cutting is consistent with the findings from Messas et al,10,11 subtle alterations in loading conditions may have influenced LV dP/dt despite the paired sequential nature of our experimental design.
In this acute sheep experiment, severing the mitral second-order strut chordae caused LV geometric perturbations that were associated with functional changes in the lateral LV region. Transmural deformations and wall-thickening mechanics were altered, and global LV systolic function deteriorated. These findings demonstrate that there is a real price to pay in terms of decreased LV systolic function if the second-order chordae are divided. The clinical question is how big a price are we willing to pay if we sacrifice second-order chordae during valve repair for ischemic MR in hearts that are already impaired?
Study Limitations
These data were obtained in an acute, open-chest setting in normal sheep hearts immediately after a complex surgical procedure and an episode of acute myocardial ischemia; therefore, caution must be exercised when extrapolating these findings to humans with chronic ischemic heart disease. Because the strut chordae are comparatively thinner in ovine hearts, however, we would anticipate that the importance of the strut chordae might be even more pronounced in humans.32 In addition, although only acute changes were measured, chronic perturbations of LV geometry after chordal cutting resulting in MR and heart failure in sheep have been described.33 Another limitation is the transient ischemia induced before the precut condition for the purpose of another analysis.15 Our experimental design, however, allowed for paired, sequential comparisons between precut and postcut conditions in the same animals without other confounding factors. The decrease in LV systolic function observed after cutting the second-order chordae might actually be more substantial in diseased hearts. We acknowledge, however, that we cannot rule out the possibility that the changes in LV function were caused by collateral damage to the endocardial LV surface from the electrocautery current or perhaps mechanical "tugging" on the second-order chordae during transection. For this reason, animals that had ventricular fibrillation during the cutting attempt were excluded from analysis. Further, it is also unlikely that progressive deterioration of ventricular function under anesthesia contributed significantly to the observed decrease in PRSW and Ees because postcut data were acquired within 5 minutes of precut data. Finally, our transmural strain analysis was limited by the small sample size, because only 4 of the 8 animals with successful chordal cutting could provide satisfactory analysis of transmural bead strains.
| Acknowledgments |
|---|
Supported by Grants HL-29589 and HL-67025 from the National Heart, Lung and Blood Institute.
We appreciate the superb technical assistance provided by Carol W. Mead, Maggie Brophy, Katha Gazda, and Mark Grisedale.
| Footnotes |
|---|
| References |
|---|
|
|
|---|
2. Hansen DE, Cahill PD, DeCampli WM, et al. Valvular-ventricular interaction: importance of the mitral apparatus in canine left ventricular systolic performance. Circulation. 1986; 73: 13101320.
3. David TE, Burns RJ, Bacchus CM, et al. Mitral valve replacement for mitral regurgitation with and without preservation of chordae tendineae. J Thorac Cardiovasc Surg. 1984; 88: 718725.[Abstract]
4. Yun KL, Sintek CF, Miller DC et al. Randomized trial comparing partial versus complete chordal-sparing mitral valve replacement: effects on left ventricular volume and function. J Thorac Cardiovasc Surg. 2002; 123: 707714.
5. Yun KL, Niczyporuk MA, Sarris GE, et al. Importance of mitral subvalvular apparatus in terms of cardiac energetics and systolic mechanics in the ejecting canine heart. J Clin Invest. 1991; 87: 247254.
6. Enriquez-Sarano M, Schaff HV, Frye RL. Mitral Regurgitation: What causes the leakage is fundamental to the outcome of valve repair. Circulation. 2003; 108: 253256.
7. Enriquez-Sarano M, Schaff HV, Orszulak TA, et al. Valve repair improves the outcome of surgery for mitral regurgitation. A multivariate analysis. Circulation. 1995; 91: 10221028.
8. Obadia JF, Casali C, Chassignolle JF, et al. Mitral subvalvular apparatus: different functions of primary and secondary chordae. Circulation. 1997; 96: 31243128.
9. Kunzelman K, Cochran R. Mechanical properties of basal and marginal mitral valve chordae tendinae. ASAIO Trans. 1990; 36: M405M408.[Medline] [Order article via Infotrieve]
10. Messas E, Guerrero JL, Handschumacher MD, et al. Chordal cutting: a new therapeutic approach for ischemic mitral regurgitation. Circulation. 2001; 104: 19581963.
11. Messas E, Pouzet B, Touchot B, et al. Efficacy of chordal cutting to relieve chronic persistent ischemic mitral regurgitation. Circulation. 2003; 108: II-111II-115.
12. Timek TA, Nielsen SL, Green GR, et al. Influence of anterior mitral leaflet second-order chordae on leaflet dynamics and valve competence. Ann Thorac Surg. 2001; 72: 535540.
13. Nielsen SL, Timek TA, Green GR, et al. Influence of anterior mitral leaflet second-order chordae tendinae on left ventricular systolic function. Circulation. 2003; 108: 486491.
14. Waldman LK, Fung YC, Covell JW. Transmural myocardial deformation in the canine left ventricle. Normal in vivo three-dimensional finite strains. Circ Res. 1985; 57: 152163.
15. Rodriguez F, Langer F, Harrington KB, et al. Cutting second-order chords does not prevent acute ischemic mitral regurgitation. Circulation. 2004; 110 (suppl II): II-91II-97.
16. Niczyporuk MA, Miller DC. Automatic tracking and digitization of multiple radiopaque myocardial markers. Comput Biomed Res. 1991; 24: 129142.[CrossRef][Medline] [Order article via Infotrieve]
17. Daughters GT, Sanders WJ, Miller DC, et al. A comparison of two analytical systems from three-dimensional reconstruction from biplane videoradiograms. Proc Comp Cardiol (IEEE). 1988; 15: 7982.
18. DeAnda A, Jr, Moon MR, Nikolic SD, et al. A method to assess endocardial regional longitudinal curvature of the left ventricle. Am J Physiol. 1995; 268: H2553H2560.
19. Moon MR, Castro LJ, DeAnda A et al. Effects of left ventricular support on right ventricular mechanics during experimental right ventricular ischemia. Circulation. 1994; 90: II92II101.
20. Spratt JA, Tyson GS, Glower DD et al. The end-systolic pressure-volume relationship in conscious dogs. Circulation. 1987; 75: 12951309.
21. Glower D, Spratt J, Snow N et al. Linearity of the Frank-Starling relationship in the intact heart: the concept of preload recruitable stroke work. Circulation. 1985; 71: 9941009.
22. Holmes JW, Takayama Y, LeGrice I, et al. Depressed regional deformation near anterior papillary muscle. Am J Physiol. 1995; 269: H262H270.
23. Takayama Y, Holmes JW, LeGrice I, et al. Enhanced regional deformation at the anterior papillary muscle insertion site after chordal transsection. Circulation. 1996; 93: 585593.
24. Streeter DD, Jr., Spotnitz HM, Patel DP, et al. Fiber orientation in the canine left ventricle during diastole and systole. Circ Res. 1969; 24: 339347.
25. Rijk-Zwikker GL, Delemarre BJ, Huysmans HA. Mitral valve anatomy and morphology: relevance to mitral valve replacement and valve reconstruction. J Card Surg. 1994; 9: 255261.[Medline] [Order article via Infotrieve]
26. Lomholt M, Nielsen SL, Hansen SB, et al. Differential tension between secondary and primary mitral chordae in an acute in-vivo porcine model. J Heart Valve Dis. 2002; 11: 337345.[Medline] [Order article via Infotrieve]
27. Ingels NB, Jr., Hansen DE, Daughters GT, et al. Relation between longitudinal, circumferential, and oblique shortening and torsional deformation in the left ventricle of the transplanted human heart. Circ Res. 1989; 64: 915927.
28. Goetz W, Lim H, Lansac E, et al. The aortomitral angle is suspended by the anterior mitral basal "stay" chords. Thorac Cardiovasc Surg. 2003; 51: 190195.[CrossRef][Medline] [Order article via Infotrieve]
29. Hansen DE, Daughters GT, Alderman EL, et al. Effect of acute human cardiac allograft rejection on left ventricular systolic torsion and diastolic recoil measured by intramyocardial markers. Circulation. 1987; 76: 9981008.
30. Tibayan FA, Lai DT, Timek TA, et al. Alterations in left ventricular torsion in tachycardia-induced dilated cardiomyopathy. J Thorac Cardiovasc Surg. 2002; 124: 4349.
31. Miller DC. Second Order Anterior Mitral Leaflets Play a Role in Preventing Systolic Anterior Motion. Ann Thorac Surg. 2002; 73: 1690.
32. Walmsley R. Anatomy of human mitral valve in adult cadaver and comparative anatomy of the valve. Br Heart J. 1978; 40: 351366.
33. Duran CMG. Editorial: Distribution of Chordae Tendinae Tension in the Porcine Mitral Valve. The Journal of Heart Valve Disease. 2002; 11: 335336.[Medline] [Order article via Infotrieve]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2004 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |