Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2004;109:357-362
Published online before print January 5, 2004, doi: 10.1161/01.CIR.0000109490.72104.EE
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
109/3/357    most recent
01.CIR.0000109490.72104.EEv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kerr, C. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kerr, C. R.
Related Collections
Right arrow Pacemaker
Right arrow Arrhythmias, clinical electrophysiology, drugs
Right arrow Embolic stroke

(Circulation. 2004;109:357-362.)
© 2004 American Heart Association, Inc.


Clinical Investigation and Reports

Canadian Trial of Physiological Pacing

Effects of Physiological Pacing During Long-Term Follow-Up

Charles R. Kerr, MD; Stuart J. Connolly, MD; Hoshiar Abdollah, MB, ChB; Robin S. Roberts, MTech; Michael Gent, DSc; Salim Yusuf, DPhil; Anne M. Gillis, MD; Anthony S.L. Tang, MD; Mario Talajic, MD; George J. Klein, MD; David M. Newman, MD, for the Canadian Trial of Physiological Pacing (CTOPP) Investigators

From the Department of Medicine, University of British Columbia, Vancouver (C.R.K.); the Departments of Medicine (S.J.C., S.Y.) and Clinical Epidemiology and Biostatistics (R.S.R., M.G.), McMaster University, Hamilton, Ontario; the Department of Medicine, University of Calgary, Calgary, Alberta (A.M.G.); the Department of Medicine, University of Ottawa, Ottawa, Ontario (A.S.L.T.); the Institut de Cardiologie de Montreal, Montreal, Quebec (M.T.); the Department of Medicine, Queens University, Kingston, Ontario (H.A.); the Department of Medicine, University of Western Ontario, London, Ontario (G.J.K.); and the Department of Medicine, University of Toronto, Toronto, Ontario (D.M.N.), Canada.

Correspondence to Dr Charles R. Kerr, Room 344, Division of Cardiology, St Paul’s Hospital, 1081 Burrard St, Vancouver, BC, Canada, V6Z 1Y6. E-mail ckerr{at}providencehealth.bc.ca

Received April 8, 2003; revision received October 20, 2003; accepted October 21, 2003.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowAppendix
down arrowReferences
 
Background— The Canadian Trial of Physiological Pacing (CTOPP) reported that the risk of stroke or cardiovascular death was similar between patients receiving ventricular versus physiological pacemakers at the end of the original follow-up period of 3 years. However, the occurrence of atrial fibrillation was significantly less frequent with physiological pacemakers. To assess a potential delayed benefit of physiological pacing, follow-up of patients in this study was extended to 6 years.

Methods and Results— A total of 1474 patients requiring a pacemaker for symptomatic bradycardia were randomized to receive ventricular and 1094 to physiological pacemakers. The primary outcome was stroke or cardiovascular death. The study was completed in July 1998, and follow-up was extended to July 2001. At a mean follow-up of 6.4 years, there was no difference between treatment groups in the primary outcome of cardiovascular death or stroke. There was no significant difference in total mortality or stroke between groups. There was a significantly lower rate of development of atrial fibrillation in the physiological group, with a relative risk reduction of 20.1% (CI, 5.4 to 32.5; P=0.009).

Conclusions— The CTOPP extended study does not show a difference in cardiovascular death or stroke, or in total mortality, or in stroke between patients implanted with ventricular or physiological pacemakers over a mean follow-up of >6 years. However, there is a persistent significant reduction in the development of atrial fibrillation with physiological pacing.


Key Words: pacemakers • mortality • stroke • fibrillation


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowAppendix
down arrowReferences
 
The Canadian Trial of Physiological Pacing (CTOPP) was the first large randomized clinical trial to examine the benefits of physiological pacing that maintained atrioventricular synchrony (dual-chamber or atrial pacing) compared with ventricular pacing with regard to the composite outcome of cardiovascular death and stroke.1 After a mean of 3.0 years of follow-up, CTOPP reported that there was no significant benefit of physiological pacing over ventricular pacing in reducing cardiovascular death or stroke. There was no reduction in overall mortality or in hospitalization for congestive heart failure. There was a moderate, statistically significant reduction in the development of atrial fibrillation. Another large trial, the Mode Selection Trial in Sinus Node Dysfunction (MOST), subsequently reported similar results.2 A post hoc analysis of CTOPP evaluated the relationship between unpaced heart rate and the effect of pacemaker selection. A low unpaced heart rate was used as a marker of those who might pace more frequently. This study reported that those with an unpaced heart rate <60 bpm benefited from physiological pacing, with a significant reduction in the incidence of cardiovascular death or stroke.3

A small, randomized study of atrial versus ventricular pacing in patients with sinus node dysfunction, the Danish Study, initially reported no benefit of physiological (AAI) pacing at a mean follow-up of 3 years.4 However, after a more extended follow-up of 5.5 years, significant reductions in death and in atrial fibrillation were reported.5 Other small studies have shown variable results with regard to outcomes of death and stroke.6 In light of the apparent delayed benefit seen in the Danish Study, we extended the follow-up of CTOPP by another 3 years to assess whether a significant difference in the primary study outcome would develop over time.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowAppendix
down arrowReferences
 
Details of the protocol of the principal CTOPP study have been published.1 Patients receiving their first pacemaker for symptomatic bradycardia (sinus node dysfunction, atrioventricular block, or both) were eligible for CTOPP. Patients <18 years of age, those in chronic atrial fibrillation, and those with life expectancy <1 year were excluded. CTOPP randomized 2568 patients (1474 to ventricular pacing and 1094 to physiological pacing) at 32 centers in Canada. Pacemakers were implanted within 48 hours of randomization.

The likelihood of more frequent pacing was estimated by observation of the unpaced heart rate at the first follow-up visit between 2 and 8 months after pacemaker implantation. The pacemaker was temporarily programmed to a rate of 40 bpm (VVI or AAI), and the underlying ventricular rate was recorded as the unpaced heart rate. Unpaced heart rate data were not available in 12% of patients.

After completion of the principal CTOPP study, a simplified follow-up was undertaken for the subsequent 3 years. Patients were followed up annually, either in the Pacemaker Clinic or by telephone contact (with the patients or physicians). Study outcomes in the extended phase were the composite outcome of cardiovascular death or stroke (primary outcome), total mortality, stroke, and new development of atrial fibrillation. The initial CTOPP analysis did not demonstrate any difference in hospitalization for congestive heart failure, and because of the need to simplify follow-up in the extended study, this outcome was not collected.

Data analysis was performed on an intention-to-treat basis. The risk of outcome events between physiological and ventricular pacing was estimated by the Kaplan-Meier method, and the results were compared by log-rank tests.7,8 Cox proportional-hazards modeling was used to evaluate the effects of baseline variables and unpaced heart rate on potential benefits of physiological pacing.9 All analyses were stratified according to study center.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowAppendix
down arrowReferences
 
Patient Enrollment/Treatment Assignment
The details of the patient screening and the treatment assignment have been reported.1 There were 2568 patients randomized in CTOPP, 1094 to physiological pacemakers, and 1474 to ventricular pacemakers. Of those assigned to physiological pacing, 93.5% received a physiological device, and of those assigned to ventricular pacing, 99.1% received a ventricular device. As previously reported, there was no difference between treatment groups in baseline characteristics or indications for pacing.1

Completeness of Follow-Up
At the end of the main study on July 1, 1998, 2002 patients remained eligible for the extended follow-up. Of these, 7 (0.3%) were never seen during the extended follow-up. The percentage follow-up at years 1, 2, and 3 of the extended follow-up were 98.4%, 95.2%, and 94.9%, respectively. The majority of patients lost to follow-up were unable to be contacted. The mean follow-up of patients randomized to the 2 study groups was the same at 6.4 years.

Pacing Mode Compliance Over Time
For patients randomized to ventricular pacing, 93% were still in VVI(R) pacing mode with a ventricular pacemaker at 8 years (Figure 1). For patients randomized to physiological pacing, 75% were receiving physiological pacing at 8 years.



View larger version (12K):
[in this window]
[in a new window]
 
Figure 1. Pacing mode compliance over time.

Outcome Events
As shown in Figure 2, the primary composite outcome of cardiovascular death or stroke occurred at a rate of 6.1% per year in patients assigned to ventricular pacing and at a rate of 5.5% per year in patients assigned to physiological pacing. There was a relative risk reduction of 8.1% with physiological pacing (95% CIs, -6.5 to 20.7; P=0.26). There was a reduction in the risk of atrial fibrillation from 5.7% per year with ventricular pacing to 4.5% per year with physiological pacing, a relative risk reduction of 20.1% (95% CIs, 5.4 to 32.5; P=0.009) (Figure 3). The magnitude of the effect of physiological pacing against atrial fibrillation was unchanged from the initial report.1 There were no differences in total mortality or in stroke between the pacing groups.



View larger version (16K):
[in this window]
[in a new window]
 
Figure 2. Cumulative risk of cardiovascular death or stroke according to mode of pacing.



View larger version (16K):
[in this window]
[in a new window]
 
Figure 3. Cumulative risk of atrial fibrillation according to mode of pacing.

Subgroup Analyses
The relationship between baseline clinical features and treatment effect was explored with regard to the primary outcome. As shown in Figure 4, no subgroup of patients experienced any benefit with physiological pacing compared with ventricular pacing. Of particular note, there is no interaction between treatment and age, even though in the initial report of the CTOPP results, there was a trend toward more benefit of physiological pacing in younger patients.



View larger version (19K):
[in this window]
[in a new window]
 
Figure 4. Effect of treatment on risk of cardiovascular death or stroke according to subgroup. Each point and bar represent hazard ratio of cardiovascular death or stroke and associated 95% CIs for physiological pacing compared with ventricular pacing. Associated probability value (for heterogeneity) indicates whether there was a significant interaction between type of pacemaker and subgroups defined by baseline characteristics. MICAD indicates myocardial infarction/coronary artery disease; LVF, left ventricular function; SA, sinoatrial; AV, atrioventricular; Afib, atrial fibrillation; Anticoag, anticoagulant therapy; Deg., degree; HB, heart block.

A subgroup analysis exploring the effect of unpaced heart rate was performed. Although there appeared to be a benefit of physiological pacing in the subgroup with an unpaced heart rate <=60 bpm, the interaction between unpaced heart rate and treatment effect was not statistically significant for the primary outcome (P=0.11) or for development of atrial fibrillation (P=0.21) (Table).


View this table:
[in this window]
[in a new window]
 
Interaction of Unpaced Heart Rate With the Primary Outcome and Atrial Fibrillation


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowAppendix
down arrowReferences
 
Main Findings
In patients with symptomatic bradycardia receiving a pacemaker, no significant reduction in cardiovascular death or stroke from physiological pacing occurred during a mean follow-up period of 6.4 years. The definition of physiological pacing in this study was atrial-based pacing, thus maintenance of atrioventricular synchrony. The reduction in development of atrial fibrillation at the end of the initial 3-year follow-up persisted during the extended follow-up. Physiological pacing reduced the number of patients who developed atrial fibrillation from 5.7% per year with ventricular pacing to 4.5% per year with physiological pacing. This 20.1% risk reduction was highly significant at 6.4 years of mean follow-up. The absolute risk reduction was 6.9% over the mean follow-up of 6.4 years. For every 100 patients treated over this period, physiological pacing would be expected to prevent atrial fibrillation in 7 patients. Extrapolated over a 10-year life expectancy of a typical pacemaker generator, physiological pacing might be expected to prevent atrial fibrillation in 11 of 100 patients treated. The number needed to treat with a physiological pacemaker to prevent atrial fibrillation is 9. Previous studies suggest that it may not be physiological pacing that prevents atrial fibrillation but rather ventricular pacing that may promote its development10–12 by permitting atrial bradycardia, stretch of the atria by atrial contraction against closed atrioventricular valves, and retrograde atrial electrical activation.

Compliance to ventricular pacing mode was high. In CTOPP, change of pacing mode for those assigned to ventricular pacing implied pacemaker generator change. The rate of upgrade to physiological pacing was <1% per year. Approximately 20% of patients assigned to physiological pacing had been converted to ventricular pacing since the initial implantation.

Importance of Atrial Fibrillation
Although a reduction in development of atrial fibrillation by physiological pacing is of potential patient benefit, the recent results of the AFFIRM Trial indicate that the clinical impact of this effect may be less important than previously thought.13,14 AFFIRM has shown that maintenance of sinus rhythm by antiarrhythmic drugs does not reduce stroke and mortality. Similarly, in the extended CTOPP, the reduction in atrial fibrillation does not translate into a statistically significant effect on the composite of cardiovascular death or stroke.

Subgroup Effects
The trend in the initial CTOPP report for younger patients to benefit more from physiological pacing has disappeared in this extended study. This may be related only to a random difference. However, there is some suggestion that this may be related to a small trend toward benefit of physiological pacing in the older group. Nonetheless, the CTOPP extended study clearly demonstrates that there is no difference in the benefit of physiological pacing with regard to the primary outcome related to age.

The subgroup analysis evaluating the relationship between unpaced heart rate and pacemaker selection previously reported3 was provocative and suggested that a benefit of physiological pacing was more pronounced in patients with low unpaced heart rate, who might be expected to use their pacemakers more frequently. One would expect that if this effect were true, with extended follow-up and a much greater number of events, this effect would become very striking. However, the interaction between unpaced heart rate and treatment effect in the extended follow-up was not statistically significant either for the primary outcome or for atrial fibrillation. A randomized clinical trial of physiological pacing versus ventricular pacing in pacemaker-dependent patients is required to test the hypothesis that patients who are pacemaker dependent have a lower rate of death and stroke with physiological pacing. A limitation of the present analysis was the inability to accurately track the percentage of time paced in either group. The unpaced heart rate was used as an indicator of those who might pace more frequently. However, this cannot be expected to accurately reflect the true percentage of pacing. Current technology would permit an accurate assessment of pacing frequency.

Comparison With Other Studies
The CTOPP Extended Study does not reproduce the delayed benefit with regard to mortality seen in the extended Danish Study.4,5 This may be because the Danish Study was small and the number of patients reaching a mean follow-up of 5.5 years was very small. Furthermore, the reduction of mortality in the Danish trial achieved only a borderline significance (P=0.04) and may have been a result of chance. There was a major difference in patient population in the 2 studies, because the Danish Study enrolled only patients with sinus node disease, and therefore, physiological pacing was achieved by atrial pacing. In CTOPP, almost all patients in the physiological group received dual-chamber pacing, and even patients with sinus node dysfunction probably paced a proportion of the time in the ventricle.

The term "physiological " was used in CTOPP to reflect the terminology at the time of development of the trial. Previous nonrandomized trials claiming marked benefits of dual-chamber pacing used the same term. Clearly, there is a strong indication that pacing from the right ventricle (usually at the apex) is not really physiological. Pacing the atrium and ventricle sequentially may solve the problem of unsynchronized contraction and prevention of atrial bradycardia, but the ventricular activation sequence is clearly not physiological. Recent studies using biventricular pacing have suggested improvement in patients with left bundle-branch block, and an extension of the theory behind this improvement suggests that right ventricular pacing might be deleterious.15,16 The recently published Dual-chamber And VVI Implantable Defibrillator (DAVID) study randomized patients receiving implantable defibrillators (ICDs) either to backup pacing at 40 bpm or to DDD-R pacing at a rate of 70 bpm.17 The composite end point of death or hospitalization with heart failure was greater in the group receiving DDD-R pacing than in the backup pacing group. This increased mortality and morbidity may be related to the increased heart rate or the right ventricular pacing or a combination of the two.

The Mode Selection Trial in Sinus Node Dysfunction (MOST) implanted dual-chamber pacemakers in patients with sinus node disease.2 The patients were then randomized to ventricular pacing versus dual-chamber pacing and followed up for a mean of 33.1 months. Congruent with the results of the CTOPP Extension, there was no difference in mortality, cardiovascular mortality, or stroke. There was a very similar benefit with regard to reduction of atrial fibrillation and a significant but weak benefit with regard to hospitalization for heart failure.

Two further important studies are pending. The UK Pace Study is evaluating elderly patients, >70 years of age, with atrioventricular block.18 This study will be important for evaluating the effect of pacing mode in a group in which many will have continuous ventricular pacing. Another Danish study is evaluating the benefits of atrial pacing alone (ensuring spontaneous ventricular depolarization) versus dual-chamber pacing in patients with sinus node disease (the Danish Multicenter Randomized Study on Atrial Inhibited versus Dual-Chamber Pacing in Sick Sinus Syndrome [DANPACE] Study).19 This study will be important in identifying the potential deleterious effect of right ventricular pacing as discussed above.

Clinical Implications
Although there is a strong preference for atrial-based atrioventricular sequential pacing in most developed countries, current evidence from randomized clinical trials provides only modest support for this approach. Dual-chamber pacemakers are more expensive, have more complications, and may require earlier replacement because of reduced generator longevity. Clinical trials have so far failed to show clear benefit for dual-chamber pacing in terms of reduction of death or stroke. Conversely, CTOPP and each of the other randomized trials have shown modest nonsignificant mortality reductions1,2,4,6 or a marginally significant reduction5 in mortality with physiological pacing. A rigorous meta-analysis is required after reporting of the United Kingdom Pacing and Cardiovascular Events (UKPACE) Trial18 to evaluate whether the choice of a physiological pacemaker results in a small but real reduction in mortality and stroke. At present, the hard evidence in favor of physiological pacing remains sketchy. Results of ongoing and future studies may show enhanced benefits of more physiological pacing techniques.


*    Appendix
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*Appendix
down arrowReferences
 
The following persons and institutions (listed in descending order according to the number of patients followed up) participated in the extended phase of the Canadian Trial of Physiological Pacing.

University of Ottawa, Heart Institute/Ottawa Civic Hospital, Ottawa, Ontario: A.S.L. Tang, W. Goldstein, M. Green, P. Hendry, G. Ewart, M. Luce, M. Scott, C. Carey, P. Theoret-Patrick; Sunnybrook HSC, Toronto, Ontario: C. Lau; University of Calgary Hospital, Calgary, Alberta: A.M. Gillis, J.M. Rothschild, K. Hillier, F. McCarthy, A. Hadley, M. Katchmer; St Michael’s Hospital, Toronto, Ontario: D. Newman, P. Dorian, J.K.Y. Yao, L. DeBellis, J. Laslop, D. Darling; London Health Sciences Centre, University Campus, London, Ontario: G.J. Klein, R. Yee, A. Skanes, A. Krahn, J. Finan; St Boniface General Hospital, Winnipeg, Manitoba: S.N. Sinha, B. Shearer, B. Champagne, J. Froese, P. Porteous; Kingston General Hospital, Kingston, Ontario: H. Abdollah, F.J. Brennan, S. Fair; Scarborough General Hospital, Toronto, Ontario: N. Perera, S. Roth, J. Cherry, V. Rambihar, R. Huhlewych, R. Stitt, A. Tinmouth, G. Vertes, A. Mukherjee, P. Taylor; Hamilton General Hospital, Hamilton, Ontario: S.J. Connolly, C. LeFeuvre, S. Yusuf, B. Doobay, M. Menard; Centenary Health Centre, Scarborough, Ontario: J. Ricci, N. Singh, J. Samuel, J. Humphries; Institut de Cardiologie de Montreal, Montreal, Quebec: M. Talajic, D. Roy, M. Dubuc, B. Thibault, P. Guena, P. Gagné, L. Lavoie, C. Villemaire; Sudbury Memorial Hospital, Sudbury, Ontario: S. Nawaz, R. Carrier, M. Hubert, G. Duxbury; Toronto East General Hospital, Toronto, Ontario: G. Rewa, M. Bentley-Taylor, V.M. Campbell, P. Fountas, A.K. Gupta, C.A. Lefkowitz, M. Thornley; University of Alberta Hospital, Edmonton, Alberta: S. Kimber, K.M. Kavanagh, E. Gelfand, M. Kantoch, A. VanSchaik, C. Mulcahey, I. Scott; Royal Victoria Hospital, Montreal, Quebec: M. Sami, A. Dobell, B. de Varennes, R. Ripley; St Catharines General Hospital, St Catharines, Ontario: R. Mackett, A. Heide, D. Kehoe; Royal University Hospital, Saskatoon, Saskatchewan: J. McMeekin, D.J. Thomson, T. Mycyk, L. Zinger; Greater Niagara General Hospital, Niagara, Ontario: Y.K. Chan, D. Zaniol, D. Thomson; Kitchener-Waterloo General Hospital, Kitchener, Ontario: C.H. Rinne, I. Janzen; St Paul’s Hospital, Vancouver, British Columbia: J.A. Boone, C. Kerr, S. Flavelle; Toronto General Hospital, Toronto, Ontario: D. Cameron, I. Lipton, L. Harris, M.B. Waxman, C. Peniston, C. Hale; Hotel-Dieu Grace Hospital, Windsor, Ontario: J.C. Fulop, R.R. Andersen, D. Fantetti; Hopital du Sacre-Coeur, Montreal, Quebec: F. Molin, P. Pagé, T. Kus, A. Langlois; Lakeridge Health Oshawa, Oshawa, Ontario: T. Monchesky, E. Long, H. Marcus, M. Pockey, P.A. Coutu, C. Harper; Valley Regional Hospital, Kentville, Nova Scotia: M.G. O’Reilly, C. Griffin, J. Comeau; Royal Columbian Hospital, New Westminster, British Columbia: R.I.G. Brown, A.D. Friesen, P. McKelvey; Vernon Jubilee Hospital, Vernon, British Columbia: R. Creel, B. Semple; Sault Area Hospitals, Sault St Marie, Ontario: D. Gould, M.T. Mathew, D. Kidd; Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia: W. Sheridan, M. Shields. Steering Committee: S. Connolly, C. Kerr, M. Gent, R. Roberts, S. Yusuf, M. Sami, D. Newman, H. Abdollah, G. Klein, M. Talajic, P. Pagé. A. Tang, C. Lau, J. Pym, D. Cameron, A.M. Gillis, F. Molin. Coordinating and Methods Centre: M. Gent, R. Roberts, S.J. Connolly, L.R. Bonilla.


*    Acknowledgments
 
The CTOPP extension study was funded by unrestricted grants from Guidant, Canada; Medtronic of Canada; and St Jude’s Medical, Canada. The primary CTOPP study was funded by the Medical Research Council of Canada.


*    Footnotes
 
Dr Kerr is a member of the advisory board of Medtronic; Dr Gillis is a member of the advisory board of and serves as a consultant to Medtronic; and Dr Klein serves as a consultant to Medtronic.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
up arrowAppendix
*References
 
1. Connolly SJ, Kerr CR, Gent M, et al. Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. N Engl J Med. 2000; 342: 1385–1391.[Abstract/Free Full Text]

2. Lamas GA, Lee KL, Sweeney MO, et al. Ventricular pacing or dual-chamber pacing for sinus node dysfunction. N Engl J Med. 2002; 346: 1854–1862.[Abstract/Free Full Text]

3. Tang AS, Roberts RS, Kerr CR, et al. Relationship between pacemaker dependency and the effect of pacing mode on cardiovascular outcomes. Circulation. 2001; 103: 3081–3085.[Abstract/Free Full Text]

4. Andersen HR, Thuesen L, Bagger JP, et al. Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndrome. Lancet. 1994; 344: 1523–1528.[CrossRef][Medline] [Order article via Infotrieve]

5. Andersen HR, Nielsen JC, Thomsen PEB, et al. Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome. Lancet. 1997; 350: 1210–1216.[CrossRef][Medline] [Order article via Infotrieve]

6. Lamas GA, Orav EJ, Stambler BS, et al. Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing. N Engl J Med. 1998; 338: 1097–1104.[Abstract/Free Full Text]

7. Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958; 53: 457–481.[CrossRef]

8. Mantel N. Evaluation of survival data and two new rank order statistics arising in its consideration. Cancer Chemother Rep. 1966; 50: 163–1670.[Medline] [Order article via Infotrieve]

9. Cox DR. Regression models and life-tables. J R Stat Soc [B]. 1972; 34: 187–220.

10. Gillis AM, Wyse DG, Connolly SJ, et al. Atrial pacing peri-ablation for prevention of atrial fibrillation. Circulation. 1999; 99: 2553–2558.[Abstract/Free Full Text]

11. Gillis AM, Connolly SJ, Lacombe P, et al. Comparison of DDDR versus VDD pacing post-AV node ablation for prevention of atrial fibrillation. Circulation. 2000; 102: 736–741.[Abstract/Free Full Text]

12. Gillis AM. Atrial pacing to prevent atrial fibrillation. Cardiol Clin. 2000; 18: 25–36.[CrossRef][Medline] [Order article via Infotrieve]

13. The AFFIRM Investigators. Baseline characteristics of patients with atrial fibrillation: the AFFIRM Study. Am Heart J. 2002; 143: 991–1001.[CrossRef][Medline] [Order article via Infotrieve]

14. Wyse DG, AFFIRM Investigators. AFFIRM results: American College of Cardiology late-breaking clinical trials. J Am Coll Cardiol. 2002; 40: 6–7.

15. Abraham WT, Fisher WG, Smith AL, et al. Cardiac resynchronization in chronic heart failure. N Engl J Med. 2002; 346: 1845–1853.[Abstract/Free Full Text]

16. Auricchio A, Stellbrink C, Sack S, et al. Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay. J Am Coll Cardiol. 2002; 39: 2026–2033.[Abstract/Free Full Text]

17. The DAVID Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator. JAMA. 2002; 288: 3115–3123.[Abstract/Free Full Text]

18. Toff WD, Skehan JD, De Bono DP, et al. The United Kingdom pacing and cardiovascular events (UKPACE) trial. Heart. 1997; 78: 221–223.[Free Full Text]

19. Andersen HR, Svendsen JH. The Danish Multicenter Randomized Study on Atrial Inhibited versus Dual-Chamber Pacing in Sick Sinus Syndrome (The DANPACE Study). Heart Drug. 2001; 1: 67–70.[CrossRef]




This article has been cited by other articles:


Home page
EuropaceHome page
A. Proclemer, M. Ghidina, D. Gregori, D. Facchin, L. Rebellato, E. Zakja, M. Gulizia, and P. Esente
Trend of the main clinical characteristics and pacing modality in patients treated by pacemaker: data from the Italian Pacemaker Registry for the quinquennium 2003-07
Europace, November 9, 2009; (2009) eup346v1.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. Silberbauer, R. A. Veasey, N. Freemantle, A. Arya, L. Boodhoo, and N. Sulke
The relationship between high-frequency right ventricular pacing and paroxysmal atrial fibrillation burden
Europace, November 1, 2009; 11(11): 1456 - 1461.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A. M. Gillis, M. Morck, D. V. Exner, R. S. Sheldon, H. J. Duff, B. L. Mitchell, and G. D. Wyse
Impact of atrial antitachycardia pacing and atrial pace prevention therapies on atrial fibrillation burden over long-term follow-up
Europace, August 1, 2009; 11(8): 1041 - 1047.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. P. H.M. Delnoy, J. P. Ottervanger, H. O. Luttikhuis, D. H.S. Vos, A. Elvan, A. R. Ramdat Misier, W. P. Beukema, P. Steendijk, and N. M. van Hemel
Pressure-volume loop analysis during implantation of biventricular pacemaker/cardiac resynchronization therapy device to optimize right and left ventricular pacing sites
Eur. Heart J., April 1, 2009; 30(7): 797 - 804.
[Abstract] [Full Text] [PDF]


Home page
ESC Textbook of Cardiovascular MedicineHome page
P. E. Vardas, H. E. Mavrakis, and W. D. Toff
CHAPTER 27 Bradycardia
ESC Textbook of Cardiovascular Medicine, January 1, 2009; 2(1): med-9780199566990-chapter - med-9780199566990-chapter.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
C. M. Fored, F. Granath, F. Gadler, P. Blomqvist, J. Rynder, C. Linde, A. Ekbom, and M. Rosenqvist
Atrial vs. dual-chamber cardiac pacing in sinus node disease: a register-based cohort study
Europace, July 1, 2008; 10(7): 825 - 831.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, D. L. Hayes, et al.
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons
J. Am. Coll. Cardiol., May 27, 2008; 51(21): e1 - e62.
[Full Text] [PDF]


Home page
CirculationHome page
Writing Committee Members, A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, et al.
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons
Circulation, May 27, 2008; 117(21): e350 - e408.
[Full Text] [PDF]


Home page
Eur Heart J SupplHome page
L. Padeletti, P. Pieragnoli, V. Jentzen, and A. Schuchert
The comorbidity of atrial fibrillation and heart failure: a challenge for electrical therapies
Eur. Heart J. Suppl., December 1, 2007; 9(suppl_I): I81 - I86.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
M. Kuhne, B. Schaer, C. Kaufmann, N. Moulay, T. Cron, T. Cueni, P. Weiss, C. Schindler, C. Sticherling, and S. Osswald
A randomized trial comparing two different approaches of pacemaker selection
Europace, December 1, 2007; 9(12): 1185 - 1190.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
Authors/Task Force Members, P. E. Vardas, A. Auricchio, J.-J. Blanc, J.-C. Daubert, H. Drexler, H. Ector, M. Gasparini, C. Linde, F. B. Morgado, et al.
Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm Association
Europace, October 1, 2007; 9(10): 959 - 998.
[Full Text] [PDF]


Home page
Eur Heart JHome page
Authors/Task Force Members, P. E. Vardas, A. Auricchio, J.-J. Blanc, J.-C. Daubert, H. Drexler, H. Ector, M. Gasparini, C. Linde, F. B. Morgado, et al.
Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm Association
Eur. Heart J., September 2, 2007; 28(18): 2256 - 2295.
[Full Text] [PDF]


Home page
EuropaceHome page
N. Sulke, J. Silberbauer, L. Boodhoo, N. Freemantle, K. Kamalvand, S. O'Nunain, D. Hildick-Smith, G. W. Lloyd, N. R. Patel, and V. Paul
The use of atrial overdrive and ventricular rate stabilization pacing algorithms for the prevention and treatment of paroxysmal atrial fibrillation: the Pacemaker Atrial Fibrillation Suppression (PAFS) study
Europace, September 1, 2007; 9(9): 790 - 797.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. C. Lin, M. Goldstein, and D. G. Benditt
UKPACE: to die, or not to die ... Is that the question?
Europace, October 1, 2006; 8(10): 852 - 854.
[Full Text] [PDF]


Home page
CirculationHome page
H.-F. Tse and C.-P. Lau
Clinical Trials for Cardiac Pacing in Bradycardia: The End or the Beginning?
Circulation, July 4, 2006; 114(1): 3 - 5.
[Full Text] [PDF]


Home page
CirculationHome page
J. S. Healey, W. D. Toff, G. A. Lamas, H. R. Andersen, K. E. Thorpe, K. A. Ellenbogen, K. L. Lee, A. M. Skene, E. B. Schron, J. D. Skehan, et al.
Cardiovascular Outcomes With Atrial-Based Pacing Compared With Ventricular Pacing: Meta-Analysis of Randomized Trials, Using Individual Patient Data
Circulation, July 4, 2006; 114(1): 11 - 17.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J. M Morgan
Basics of cardiac pacing: selection and mode choice.
Heart, June 1, 2006; 92(6): 850 - 854.
[Full Text] [PDF]


Home page
EuropaceHome page
J. Caro, A. Ward, and J. Moller
Modelling the health benefits and economic implications of implanting dual-chamber vs. single-chamber ventricular pacemakers in the UK
Europace, June 1, 2006; 8(6): 449 - 455.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Hoffmann, N. Sulke, N. Edvardsson, J. Ruiter, T. Lewalter, A. Capucci, A. Schuchert, S. Janko, J. Camm, and on behalf of the Atrial Fibrillation Therapy (AFT)
New Insights Into the Initiation of Atrial Fibrillation: A Detailed Intraindividual and Interindividual Analysis of the Spontaneous Onset of Atrial Fibrillation Using New Diagnostic Pacemaker Features
Circulation, April 25, 2006; 113(16): 1933 - 1941.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
G. Frohlig, D. Gras, J. Victor, P. Mabo, D. Galley, A. Savoure, G. Jauvert, P. Defaye, P. Ducloux, and A. Amblard
Use of a new cardiac pacing mode designed to eliminate unnecessary ventricular pacing.
Europace, February 1, 2006; 8(2): 96 - 101.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
C. W. Israel
The role of pacing mode in the development of atrial fibrillation.
Europace, February 1, 2006; 8(2): 89 - 95.
[Abstract] [Full Text] [PDF]


Home page
Oxford Handbook of CardiologyHome page
P. Ramrakha and J. Hill
Chapter 15 Major trials in cardiology
Oxford Handbook of Cardiology, January 1, 2006; 1(1): med-9780198525974-chapter - med-9780198525974-chapter.
[Full Text]


Home page
NEJMHome page
W. D. Toff, A. J. Camm, J. D. Skehan, and the United Kingdom Pacing and Cardiovascular Event
Single-Chamber versus Dual-Chamber Pacing for High-Grade Atrioventricular Block
N. Engl. J. Med., July 14, 2005; 353(2): 145 - 155.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. M. Scheinman and E. Keung
The year in clinical electrophysiology
J. Am. Coll. Cardiol., March 1, 2005; 45(5): 790 - 795.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. R. Kerr
Stroke and pacing mode: is pacing mode important?
J. Am. Coll. Cardiol., May 5, 2004; 43(9): 1623 - 1624.
[Full Text] [PDF]


Home page
EuropaceHome page
A. Schuchert
Contributions of permanent cardiac pacing in the treatment of atrial fibrillation
Europace, January 1, 2003; 5(s1): S36 - S41.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
109/3/357    most recent
01.CIR.0000109490.72104.EEv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kerr, C. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kerr, C. R.
Related Collections
Right arrow Pacemaker
Right arrow Arrhythmias, clinical electrophysiology, drugs
Right arrow Embolic stroke