Correspondence to Dean J. Kereiakes, MD, The Lindner Center for Research & Education, 2123 Auburn Ave, Suite 424, Cincinnati, OH 45219 (e-mail lindner{at}fuse.net) and James T. Willerson, MD, St Lukes Episcopal Hospital/Texas Heart Institute, 6720 Bertner Ave, Room B524 (MCI-267), Houston, TX 770302697 (e-mail suzy.lanier@uth.tmc.edu).
 |
Introduction
|
|---|
Alvin Toffler, a 20th century philosopher and author of the
novel
Future Shock once said, "As we move into the 21st century,
not only will technology advance, but the rate at which technology
advances will increase exponentially."
1 Perhaps those technological
advances with greatest relevance to the health and welfare of
society involve science and healthcare. Indeed, societal demands
for new drug and device design and development have never been
greater. Because of advances in medical care, the mortality
from cardiovascular diseases has progressively declined over
the past 2 decades. We currently stand on the threshold of "cures"
for several of mankinds greatest afflictions, including
cancer, atherosclerotic cardiovascular disease, and human immunodeficiency
disease.
2 Obviously, the time efficiency of providing potentially
live saving technologies to society is cruciallives literally
depend on this process. Ideally, benchmarks for safety and efficacy
of technology should be satisfied before drug/device availability
to assure net clinical benefit. The "gatekeeper" for medical
technology is the United States Food and Drug Administration
(USFDA), whose charge it is to promote and protect the public
health by making safe and effective medical technologies available
in a timely manner. Furthermore, in the current era of escalating
costs for medical technology, the time required for the development-FDA
approval-release process ("time to market") translates directly
into drug/device pricing. In recent years, as cardiovascular
specialists, we have been fortunate to be provided with both
primary preventative therapies (aspirin, statins, angiotensin-converting
enzyme inhibitors, etc) that reduce the prevalence of cardiovascular
disease, in addition to exciting new technologies (implantable
cardiac defibrillators, cardiac resynchronization therapy, drug-eluting
stents, etc) that substantially reduce the morbidity and mortality
for those in whom this disease is established.
As clinical investigators for new technologies, we are acutely aware of a widening time gap between the availability of US industry-developed technologies in Europe or other countries outside the US and the United States itself. Concern exists that a bureaucratic process should not disadvantage the US public by stifling timely access to new or improved medical technology. Probably no other single topic more effectively aligns the incentives of all interested parties, including the US public, physician investigators, industry, and the USFDA. Close collaboration between physician investigators, industry, and the USFDA is essential to effect enhanced efficiency in the process of device development, USFDA approval, and release, while still maintaining a premium on public safety. Such a collaborative effort is made evident in the current issue of Circulation by Aaron Kaplan, MD, et al,3 who describe in detail the current process by which new medical devices are developed, undergo clinical testing, and are evaluated by the USFDA. In addition, a consensus proposal for improving our current system is provided in the accompanying work by Mehran et al.4
 |
The Present
|
|---|
An accurate understanding of the US regulatory approval process
and its components from first-in-man clinical testing, FDA investigational
device exemption, and pivotal trial evaluation through pre-market
approval application submission and FDA approval is provided
in the work of Kaplan et al.
3 In addition, the comparable regulatory
process in European Union (EU) countries is described. Basic
fundamental differences between the US and EU processes include
the use of independent commercial organizations (notified bodies)
to implement regulatory control, as well as a primary focus
on device safety rather than proven efficacy in the EU system.
A conceptual understanding of both the potential advantages
and pitfalls of the EU system are important in objectively assessing
the US regulatory process and in devising strategies for improvement.
Indeed, in the article by Mehran et al,
4 a more comprehensive
and integrated approach to new device development and approval
is proposed. The concept of effective post-market surveillance
to facilitate pre-market approval is intuitively attractive.
Furthermore, Mehran et al
4 outline the inadequacies of the current
US post-market surveillance system. Clearly, substantive improvements
in the post-market surveillance process are prerequisite for
implementing the proposed strategy.
In return for the privilege of more timely availability of technology, physicians, healthcare institutions, and industry have a joint responsibility for more accurate, systematic, and comprehensive new device surveillance. The current medical device reporting program is woefully inaccurate and incomplete. Furthermore, a mechanism for systematic audit must be in place to assure both accuracy and completeness of the data compiled. Quality-assured data on device safety and clinical efficacy over time in large, diverse patient populations would be invaluable to the understanding of a new devices impact on a specific disease state. The availability of such data could substantially enhance the adoption of a technology for new indications, as well as for the current FDA "labeling" process. These data, by virtue of their magnitude, could materially influence the development and continuous quality improvement cycle of clinical practice guidelines for device use.5 Clearly, one cannot underestimate the potential importance of a large-scale, quality-assured clinical database that includes long-term follow-up post-device utilization as part of a continuous quality-improvement feedback loop to clinical practice. Obviously, the integrity of the data is essential and current disincentives for physicians who encounter adverse events in the course of off-label device utilization must be overcome.
 |
The Future
|
|---|
The proposal of Mehran and colleagues
4 represents an important
first step in the evolution of our current regulatory process.
A step, they believe, that will enhance the efficiency of our
current system without jeopardizing its safety. Indeed, the
database they propose to develop addresses glaring deficiencies
in our current regulatory and healthcare systems. It is remarkable
that we have come to the present point in time without a reliable
mechanism in place to track and monitor new device utilization.
A case study in point is provided by both Kaplan et al
3 and
Mehran et al
4 in the Cypher drug-eluting stent. In an initially
limited and select randomly assigned patient population, this
device demonstrated remarkable effectiveness and safety in reducing
restenosis and the requirement for repeat coronary revascularization
when compared with conventional coronary stenting. Nevertheless,
specific comments regarding the Cypher stent made during the
course of the FDA panel evaluation or after approval are noteworthy.
For example, in reference to the pivotal US trial of this device
in 1100 patients randomly assigned to treatment with either
Cypher or BX Velocity stents, Mitchell Krucoff, MD, of the FDA
panel queried, "What is the beta error level for a 1000 patient
randomized study? Could we miss a 1% adverse outcome?"
6 Indeed,
the potential for missing a low frequency occurrence adverse
outcome even in the course of a pivotal trial on which USFDA
approval is contingent is evident, and yet could become quite
obvious by extrapolation to the >600 000 patients/year who
undergo coronary stent implantation in the United States. The
mechanisms currently available for device surveillance, as well
as their limitations, are succinctly summarized by Mehran et
al.
4 A dependable, comprehensive post-market surveillance system
may have reduced the subsequent sensational revelation of the
potential propensity for Cypher stent thrombosis, as well as
the consequent USFDA response to a non-event. Similarly, an
accurate assessment of the impact of this revolutionary device
technology on clinical practice was in large part missed. Access
to quality, clinical data in an expanded patient population
might have allowed practicing physicians to more rapidly and
confidently extend use of this device to patient subsets not
included during randomized clinical trial testing. As aptly
queried by established physician investigators, "should standard
practice patterns undergo marked immediate changes when fewer
than 2000 patients have been studied in 3 clinical trials?"
(before Cypher stent USFDA approval).
7
These issues are not likely to be solved simply by integrating currently available, fragmented data sources from Medicare/third party claims made, device specific registries, or society databases. Little or no assurance of accuracy or completeness exists even if Health Insurance Portability and Accountability Act-compliant integration of these data sources were to occur. A more accurate and comprehensive system is required to assure safety and efficacy of new technologies. Support for a new post-market surveillance system could be provided through collaboration and consolidation of resources currently allocated to our fragmented and less comprehensive data sources, as well as by a portion of industry profits derived from expedited device approval, if achieved. Indeed, "time to market" can be worth $1 million per day to industry.
The proposal by Mehran and colleagues4 is in response to the current 1- to 3-year gap for introduction of new device technologies in EU countries and the US, respectively. Although attractive and ultimately quite informative, this proposal will no doubt be challenging and costly to implement. The information technology is currently available to accomplish this goal if political barriers and self-interest of stake- holder parties can be overcome. These potential obstacles must be subjugated by the willing collaboration between clinical investigators, industry, and FDA regulators in the best interest of our patients.
 |
Footnotes
|
|---|
The opinions expressed in this article are not necessarily those
of all the editors or of the American Heart Association.
 |
References
|
|---|
- Toffler A. Future Shock. New York, NY: Random House; 1970.
- Wyke A. New anatomy lesson, please. Economist. 2004; 330: 3.
- Kaplan AV, Baim DS, Smith JJ, et al. Medical device development: from prototype to regulatory approval. Circulation. 2004; 109: 30683072.[Free Full Text]
- Mehran R, Leon MB, Feigal DA, et al. Post-market approval surveillance: a call for a more integrated and comprehensive approach. Circulation. 2004; 109: 30733077.[Free Full Text]
- Califf RM, Peterson ED, Gibbons RM, et al. Integrating quality into the cycle of therapeutic development. J Am Coll Cardiol. 2002; 40: 18951901.[Abstract/Free Full Text]
- US Food and Drug Administration, Center for Devices and Radiological Health. Cypher sirolimus-eluting coronary stent on RAPTOR over-the-wire delivery system or RAPTORRAIL rapid exchange delivery system. Available at: http://www.fda.gov/cdrh/pdf3/p020026.html. Accessed May 27, 2003.
- ONeill WW, Leon MB. Drug-eluting stents: costs versus clinical benefit. Circulation. 2003; 107: 30083011.[Free Full Text]
This article has been cited by other articles:

|
 |

|
 |
 
J. Somberg, W. Laskey, D. Morrison, J. Weinberger, D. J. Kereiakes, A. V. Kaplan, and R. Mehran
Letter Regarding Articles by Kereiakes and Willerson, Mehran et al, and Kaplan et al, "Mini-Review: Expert Opinion" * Response
Circulation,
March 29, 2005;
111(12):
e164 - e165.
[Full Text]
[PDF]
|
 |
|