(Circulation. 2004;109:1960-1965.)
© 2004 American Heart Association, Inc.
Clinical Investigation and Reports |
From the Department of Emergency Medicine, Medical College of Wisconsin, Milwaukee (T.P.A., R.G.P., C.J.C.); Advanced Circulatory Systems, Inc, Eden Prairie, Minn (C.v.B., C.W.S., T.A.P., K.G.L.); and the Cardiac Arrhythmia Center, Departments of Internal Medicine and Emergency Medicine, Hennepin County Medical Center, University of Minnesota, Minneapolis (G.S., D.Y., S.M.).
Correspondence to Keith G. Lurie, MD, Box 508, UMHC, 420 Delaware Street SE, Minneapolis, MN 55455. E-mail lurie002{at}tc.umn.edu
Received October 22, 2003; revision received December 30, 2003; accepted February 2, 2004.
| Abstract |
|---|
|
|
|---|
Methods and Results In humans, ventilation rate and duration during CPR was electronically recorded by professional rescuers. In 13 consecutive adults (average age, 63±5.8 years) receiving CPR (7 men), average ventilation rate was 30±3.2 per minute (range, 15 to 49). Average duration per breath was 1.0±0.07 per second. No patient survived. Hemodynamics were studied in 9 pigs in cardiac arrest ventilated in random order with 12, 20, or 30 breaths per minute. Survival rates were then studied in 3 groups of 7 pigs in cardiac arrest that were ventilated at 12 breaths per minute (100% O2), 30 breaths per minute (100% O2), or 30 breaths per minute (5% CO2/95% O2). In animals treated with 12, 20, and 30 breaths per minute, the mean intrathoracic pressure (mm Hg/min) and coronary perfusion pressure (mm Hg) were 7.1±0.7, 11.6±0.7, 17.5±1.0 (P<0.0001), and 23.4±1.0, 19.5±1.8, and 16.9±1.8 (P=0.03), respectively. Survival rates were 6/7, 1/7, and 1/7 with 12, 30, and 30+ CO2 breaths per minute, respectively (P=0.006).
Conclusions Professional rescuers were observed to excessively ventilate patients during out-of-hospital CPR. Subsequent animal studies demonstrated that similar excessive ventilation rates resulted in significantly increased intrathoracic pressure and markedly decreased coronary perfusion pressures and survival rates.
Key Words: cardiopulmonary resuscitation death, sudden heart arrest ventilation hypotension
| Introduction |
|---|
|
|
|---|
This translational research initiative focused on the potential deleterious effects of excessive ventilation during CPR. At present, the American Heart Association (AHA) recommends 12 to 15 breaths per minute in patients with secured airways during the performance of CPR by healthcare professionals.4 The purpose of the present clinical observational study was to objectively and electronically record actual ventilation frequency, duration, and the percentage of time in which a positive intrathoracic pressure was recorded in the lungs during CPR performed by emergency medical services (EMS) personnel at the scene of patients with an out-of-hospital cardiac arrest. The results of this study demonstrated that rescuers consistently hyperventilated patients at the scene of out-of-hospital cardiac arrest. On the basis of these clinical results, animal studies were performed to determine the potential hemodynamic and survival rate consequences of excessive ventilation rates.
| Methods |
|---|
|
|
|---|
CFR Part 50.24) after community consultation and public notification. It was part of but unrelated to another study for which the Food and Drug Administration had approved an investigational device exemption. The Human Research Review Committee at the Medical College of Wisconsin approved the study.
The clinical observational study was performed in the City of Milwaukee, where basic life support and advanced life support EMS personnel respond in a tiered manner. Care is provided according to AHA guidelines. For the study, an additional research team including a physician and paramedic were dispatched to the scene of each patient. Entry criteria for the study were (1) adult patients (presumed or known to be
21 years) believed to be in cardiac arrest of presumed cardiac cause and (2) patients who were successfully intubated with an endotracheal tube who were undergoing CPR at the time of scene arrival of the research team. A portable pressure monitor (Propaq, Welch Allyn Protocol, Inc) was used for electronic measurement of airway pressures, a surrogate for intrathoracic pressures. After arrival at the scene and after patient intubation, the research team connected the noninvasive intrathoracic pressure sensor between the endotracheal tube and the bag-valve resuscitator. Ventilations were then continuously recorded until resuscitation attempts were discontinued or the patient was resuscitated. There are a variety of factors that may affect ventilation rate throughout the resuscitation efforts, including the practice of hyperventilating immediately before and after intubation. For this reason, we sought to determine the maximum ventilation rate, defined as the highest ventilation rate recorded during CPR over a 16-second period occurring at least 2 minutes after intubation. The ventilation frequency, duration, and percentage of time in which a positive pressure was recorded in the lungs were then calculated with a digital caliper.
The first 7 consecutive cases constitute group 1. After recognizing that rescuers were consistently hyperventilating patients in cardiac arrest, investigators immediately retrained all EMS personnel to provide ventilations at a rate of 12 breaths per minute during CPR after establishment of a secured airway. The duration of each ventilation was not addressed during retraining. The subsequent 6 consecutive cases (after retraining) constitute group 2. Data were also analyzed by combining groups 1 and 2 (group 3). Differences between the means of groups 1 and 2 were statistically analyzed by ANOVA. A probability value of <0.05 was considered statistically significant. All data are expressed as mean±SEM.
Results: Clinical Observational Study
The average age of the 13 consecutive patients (6 women, 7 men) was 63±5.8 years (range, 34 to 96); 3 patients had an initial rhythm of ventricular fibrillation (VF), 5 had pulseless electrical activity, and 5 had asystole. Overall, the maximum ventilation rate was observed an average of 18.8±11.9 minutes after intubation (range, 2 to 39 minutes). No patient survived. The average maximum ventilation rate for group 1 patients was 37±4 breaths per minute (range, 19 to 49), ventilation duration was 0.85±0.07 seconds/breath, and the percentage of time in which a positive pressure was recorded in the airway was 50±4% (Table 1). After retraining, 3 of 6 group 2 patients had ventilation rates
26 breaths per minute. The ventilation rate for these 6 patients was slower than in group 1 patients, at 22±3 breaths per minute (range, 15 to 31). However, ventilation duration was significantly longer than in group 1 patients (1.18±0.06 versus 0.85±0.07 seconds/breath, respectively, P<0.05). As a result, the percentage of time in which a positive pressure was recorded in the airway was similar in group 2 and group 1 patients (44.5±8.2% versus 50±4%, respectively) (P=NS). Combining groups 1 and 2 (group 3), the ventilation rate for all 13 patients was 30 breaths per minute (twice the AHA-recommended rate).
|
Individual recordings provide insight into the rate and duration of ventilations provided by professional rescuers. Figure 1A represents delivery of CPR relatively close to AHA guidelines. Only one such case was observed. Figure 1, B, C, and D illustrate representative examples of hyperventilation observed in the majority of cases before retraining. After retraining, slower ventilation rates were seen in group 2 patients, but ventilation duration was more prolonged (Figure 1E). As a result, the percentage of time in which a positive pressure was recorded in the airway was not significantly different between groups 1 and 2.
|
Animal Studies
The porcine hemodynamic and survival studies were approved by the Committee of Animal Experimentation at the University of Minnesota. The animals received care in compliance with the 1996 Guide for the Care and Use of Laboratory Animals by the National Research Council. The animal preparation and surgical techniques have been previously described in detail.3 Briefly, each animal received 10 mL (100 mg/mL) of intramuscular ketamine HCl for initial sedation, followed by intravenous propofol (2.3-mg/kg bolus and then a constant intravenous infusion of 165 µg/kg per minute). During the preparatory phase, animals were ventilated with room air by a positive-pressure ventilator (Harvard Apparatus Co). The rate and tidal volume were adjusted to maintain an arterial carbon dioxide (PaCO2) at 40 mm Hg and oxygen saturation >90%, based on analysis of arterial blood gases (IL Synthesis, Instrumentation Laboratory).
Central aortic and right atrial pressures were recorded continuously using a micromanometer-tipped catheter (Mikro-Tip Transducer, Millar Instruments). All animals were treated with heparin (100 U/kg IV) as a single bolus once catheters were in place. Intrathoracic pressures were measured continuously with a micromanometer-tipped catheter positioned within the trachea, 2 cm below the tip of the endotracheal tube at the level of the carina. End-tidal carbon dioxide (ETCO2) was recorded continuously (CO2SMO Plus, Novametrix Medical Systems).
Resuscitation Protocols
Ventricular fibrillation was induced by using a 5F bipolar pacing catheter (St Jude Medical Corp) placed into the right ventricle, with alternating current at 7 V and 60 Hz. As soon as VF was induced, the positive-pressure ventilator was disconnected from the animal. After 6 minutes of untreated VF, closed-chest standard CPR was performed continuously with a pneumatically-driven automatic piston device (CPR Controller, AMBU International).3 The compression rate was 100 per minute with a 50% duty cycle, and the compression depth was 25% of the anterior-posterior diameter of the chest wall. After each compression, the chest wall was allowed to recoil completely and without any impedance from the compression device. Pressure-controlled, synchronous ventilations were performed with a semiautomatic ventilator (Demand Valve Model L063-05R, Life Support Products Inc) at a constant flow rate of 160 L/min. Ventilation was initiated during the decompression phase of CPR, and each breath was delivered over a 1-second period of time. During the first 2 minutes of CPR, a compression-to-ventilation ratio of 5:1 was used on all animals.
Hemodynamic Protocol (Protocol I)
After the initial 2 minutes of CPR, each animal received 3 different ventilation rates (12, 20, and 30 breaths per minute) in a computer-generated random order, with each phase lasting for 2 minutes. These 3 different ventilation rate interventions were delivered in an asynchronous manner, either every 5 seconds (12 per minute), every 3 seconds (20 per minute), or every other second (30 per minute), with each breath delivered over a period of 1 second.
During CPR, aortic, right atrial, and intrathoracic pressures were continuously recorded. ETCO2 and O2 saturation were also measured continuously and recorded every minute. Arterial blood gases were collected before induction of VF and at the end of each ventilation rate phase (after minute 8, 10, 12, and 14 of cardiac arrest).
Survival Protocol (Protocol II)
Ventilation during the first 2 minutes of CPR was delivered synchronously with a 5:1 compression-to-ventilation ratio. After the initial 2 minutes of CPR, each animal was randomized to receive 4 minutes of CPR with 1 of 3 different ventilation modes: (1) 12 breaths per minute with 100% O2; (2) 30 breaths per minute with 100% O2; or (3) 30 breaths per minute with 5% CO2 and 95% O2. Five percent CO2 was added to inspiratory gases in the third group to evaluate the effect of hyperventilation on survival in the absence of hypocarbia. During these interventions, ventilations were delivered in an asynchronous manner every 5 seconds (12/min) or every other second (30/min), with each ventilation delivered over a period of 1 second.
During CPR, aortic, right atrial, and intrathoracic pressures as well as ETCO2 and O2 saturation were continuously recorded. Arterial blood gas samples were assessed before induction of VF and at the end of each ventilation phase.
At the end of each protocol, the animals were shocked with a biphasic defibrillator (M Series, Zoll Medical Corp) using 150 J, up to 3 times, as needed.5 If resuscitation was successful, animals were ventilated with a ventilator and supplemental oxygen. Return of spontaneous circulation (ROSC) was defined as a palpable pulse over 5 minutes. Survival was defined as a stable blood-perfusing rhythm generating a measurable blood pressure over the first hour of observation after resuscitation. No other therapeutic interventions were performed after ROSC.
At the end of each study protocol, the animals were euthanized with an intravenous bolus of 60 mg propofol and then 10 mL potassium chloride.
All values are expressed as mean±SEM. Coronary perfusion pressure was calculated as the difference between aortic diastolic and right atrial diastolic pressures. For each animal, 10 measurements were performed for both aortic diastolic and right atrial diastolic pressures, and the average difference was used as the representative value for each animal. Mean intrathoracic pressure was measured as the time-averaged value from continuous measurements acquired over a 10-second period. Comparison between groups was done by ANOVA and paired t test. Survival was calculated with
2 and Fishers exact tests. A probability value of <0.05 was considered statistically significant.
| Results |
|---|
|
|
|---|
|
|
Animal Survival Studies
The survival rate in pigs ventilated at 12 breaths per minute (100% O2) was 6 of 7 (86%), compared with a survival rate of 1 of 7 (17%) at a rate of 30 breaths per minute (100% O2), and 1/7 (17%) at a ventilation rate of 30 breaths per minute (5% CO2/95% O2) (P=0.006) (Figure 3). Mean intrathoracic pressures were significantly higher with the higher ventilation rates (P<0.0001), and coronary perfusion pressures were lower (Table 3). Changes in arterial blood gases and ETCO2 with hyperventilation are shown in Table 4. Pigs ventilated at 30 breaths per minute (100% O2) had lower levels of PaCO2 (Table 4). Supplemental CO2 resulted in correction of hypocapnia (Figure 3 and Table 4).
|
|
|
| Discussion |
|---|
|
|
|---|
During the decompression phase of standard CPR, a small vacuum is created within the chest relative to the rest of the body every time the chest wall recoils back to its resting position.10 This draws venous blood back into the right heart.10 Accentuating this small vacuum with use of an inspiratory impedance valve has been shown to significantly increase vital organ blood flow,11 coronary perfusion pressure,11 and survival.3 Conversely, the physiological consequences of hyperventilation and of prolonged ventilation intervals result in a persistently positive intrathoracic pressure during the decompression phase of CPR, thereby decreasing cardiac preload6 and cardiac output7 and impeding right ventricular function.8 Increased tidal volume is also known to adversely affect cardiac output.9 In the present study, the mean intrathoracic pressure was significantly elevated in animals treated with higher ventilation rates. We speculate that the elevated mean intrathoracic pressures caused by excessive ventilation inhibited venous blood flow back to the right heart, as there was insufficient time to allow for the development of negative intrathoracic pressure between compressions. It is important to note that intrathoracic pressures never went below 0 mm Hg when ventilation rates were 30 per minute. The current results also support the contention that hypocapnia was not the cause of decreased coronary perfusion pressure and death in animals ventilated at 30 breaths per minute. When supplemental CO2 at 5% was delivered to one group of pigs at a concentration identical to that found in expiratory gases to prevent hypocapnia without causing hypercarbia, the PaCO2 level did not fall below 35.4±0.6 mm Hg, and survival rates (1/7) were identical to pigs hyperventilated with 100% O2.
The data demonstrate that any incidence of hyperventilation is likely to have detrimental hemodynamic and survival consequences during low flow states such as CPR. Unrecognized and inadvertent hyperventilation may be contributing to the currently dismal survival rates from cardiac arrest. Similar detrimental effects of hyperventilation have recently been described in the setting of hemorrhagic shock.12 Although the extent to which this clinical observation applies to other EMS systems needs to be determined through additional study, based on the current study, we strongly encourage medical directors to assess whether hyperventilation during CPR is inadvertently occurring in the care systems under their medical direction.
This study also demonstrates a significant difference between CPR performance by EMS personnel in the classroom and performance during an actual cardiac arrest as well as a potential direct relation between the quality of CPR delivered and victim survival. These observations have significant implications for the interpretation and design of resuscitation research, CPR guidelines, education, clinical practice, the development of future CPR devices, and EMS quality assurance.
There are several important limitations to this study. First, the clinical observations were only made in a single city and with a limited number of patients. We believed it was unethical to continue to collect data once we recognized the potential lethal nature of the observed hyperventilation. We found only one other published report in which ventilation rates for patients with an in-hospital cardiac arrest were as high as 70 times per minute.13 Nonetheless, we do not know how widespread this problem is, and further study is warranted to characterize its prevalence nationally and internationally. Second, the animal hemodynamic studies focused on coronary perfusion pressures and intrathoracic pressures. The physiological effects of excessive ventilation rates may be underestimated by not measuring actual blood flow. Finally, animal survival studies were not performed at ventilation rates of <12 breaths per minute. The optimal ventilation rate for patients in cardiac arrest has yet to be defined and may well be lower than 12 breaths per minute.
| Conclusions |
|---|
|
|
|---|
| Acknowledgments |
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
2. Berg RA, Sanders AB, Kern KB, et al. Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest. Circulation. 2001; 104: 24652470.
3. Lurie KG, Zielinski T, McKnite S, et al. Use of an inspiratory impedance threshold valve improves neurologically intact survival in a porcine model of ventricular fibrillation. Circulation. 2002; 105: 124129.
4. American Heart Association, in collaboration with International Liaison Committee on Resuscitation. Guidelines 2000 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care: International Consensus on Science, Part 1: Introduction. Circulation. 2000; 102 (suppl I): I-1I-384.[Medline] [Order article via Infotrieve]
5. Zhang Y, Clark CB, Davies LR, et al. Body weight is a predictor of biphasic shock success for low energy transthoracic defibrillation. Resuscitation. 2002; 54: 281287.[CrossRef][Medline] [Order article via Infotrieve]
6. Cournand A, Motley HL, Werko L, et al. Physiological studies of the effects of intermittent positive pressure breathing on cardiac output. Am J Physiol. 1948; 152: 162174.[Medline] [Order article via Infotrieve]
7. Cheifetz IM, Craig DM, Quick G, et al. Increasing tidal volumes and pulmonary overdistention adversely affect pulmonary vascular mechanics and cardiac output in a pediatric swine model. Crit Care Med. 1998; 26: 710716.[CrossRef][Medline] [Order article via Infotrieve]
8. Theres H, Binkau J, Laule M, et al. Phase-related changes in right ventricular cardiac output under volume-controlled mechanical ventilation with positive end-expiratory pressure. Crit Care Med. 1999; 27: 953958.[CrossRef][Medline] [Order article via Infotrieve]
9. Karlsson T, Stjernstrom EL, Stjernstrom H, et al. Central and regional blood flow during hyperventilation: an experimental study in the pig. Acta Anaesthesiol Scand. 1994; 38: 180186.[Medline] [Order article via Infotrieve]
10. Lurie KG, Voelckel WG, Plaisance P, et al. Use of an impedance threshold valve during cardiopulmonary resuscitation: a progress report. Resuscitation. 2000; 44: 219230.[CrossRef][Medline] [Order article via Infotrieve]
11. Lurie KG, Mulligan KA, McKnite S, et al. Optimizing standard cardiopulmonary resuscitation with an impedance threshold valve. Chest. 1998; 113: 10841090.
12. Pepe PE, Raedler C, Lurie KG, et al. Emergency ventilatory management in hemorrhagic states: elemental or detrimental? J Trauma. 2003; 54: 10481057.[Medline] [Order article via Infotrieve]
13. Milander MM, Hiscok PS, Sanders AB, et al. Chest compression and ventilation rates during cardiopulmonary resuscitation: the effects of audible tone guidance. Acad Emerg Med. 1995; 2: 708713.[Medline] [Order article via Infotrieve]
This article has been cited by other articles:
![]() |
G. A. Ewy Do Modifications of the American Heart Association Guidelines Improve Survival of Patients with Out-of-Hospital Cardiac Arrest? Circulation, May 19, 2009; 119(19): 2542 - 2544. [Full Text] [PDF] |
||||
![]() |
A. G. Garza, M. C. Gratton, J. A. Salomone, D. Lindholm, J. McElroy, and R. Archer Improved Patient Survival Using a Modified Resuscitation Protocol for Out-of-Hospital Cardiac Arrest Circulation, May 19, 2009; 119(19): 2597 - 2605. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Dichtwald, I. Matot, and S. Einav Improving the Outcome of In-Hospital Cardiac Arrest: The Importance of Being EARNEST Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2009; 13(1): 19 - 30. [Abstract] [PDF] |
||||
![]() |
G. A. Ewy and K. B. Kern Recent advances in cardiopulmonary resuscitation: cardiocerebral resuscitation. J. Am. Coll. Cardiol., January 13, 2009; 53(2): 149 - 157. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Neumar, J. P. Nolan, C. Adrie, M. Aibiki, R. A. Berg, B. W. Bottiger, C. Callaway, R. S.B. Clark, R. G. Geocadin, E. C. Jauch, et al. Post-Cardiac Arrest Syndrome: Epidemiology, Pathophysiology, Treatment, and Prognostication A Consensus Statement From the International Liaison Committee on Resuscitation (American Heart Association, Australian and New Zealand Council on Resuscitation, European Resuscitation Council, Heart and Stroke Foundation of Canada, InterAmerican Heart Foundation, Resuscitation Council of Asia, and the Resuscitation Council of Southern Africa); the American Heart Association Emergency Cardiovascular Care Committee; the Council on Cardiovascular Surgery and Anesthesia; the Council on Cardiopulmonary, Perioperative, and Critical Care; the Council on Clinical Cardiology; and the Stroke Council Circulation, December 2, 2008; 118(23): 2452 - 2483. [Full Text] [PDF] |
||||
![]() |
D. P. Edelson, B. Litzinger, V. Arora, D. Walsh, S. Kim, D. S. Lauderdale, T. L. Vanden Hoek, L. B. Becker, and B. S. Abella Improving In-Hospital Cardiac Arrest Process and Outcomes With Performance Debriefing Arch Intern Med, May 26, 2008; 168(10): 1063 - 1069. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. J. Bobrow, L. L. Clark, G. A. Ewy, V. Chikani, A. B. Sanders, R. A. Berg, P. B. Richman, and K. B. Kern Minimally Interrupted Cardiac Resuscitation by Emergency Medical Services for Out-of-Hospital Cardiac Arrest JAMA, March 12, 2008; 299(10): 1158 - 1165. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Herff, P. Paal, A. von Goedecke, T. Mitterlechner, T. Danninger, and V. Wenzel Minimizing Stomach Inflation Versus Optimizing Chest Compressions Anesth. Analg., February 1, 2008; 106(2): 535 - 537. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Paal, M Falk, E Gruber, W Beikircher, G Sumann, F Demetz, J Ellerton, V Wenzel, and H Brugger Retention of mouth-to-mouth, mouth-to-mask and mouth-to-face shield ventilation Emerg. Med. J., January 1, 2008; 25(1): 42 - 45. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. A. Ewy Continuous-Chest-Compression Cardiopulmonary Resuscitation for Cardiac Arrest Circulation, December 18, 2007; 116(25): 2894 - 2896. [Full Text] [PDF] |
||||
![]() |
K. J Warner and E. M Bulger Does pre-hospital ventilation effect outcome after significant brain injury? Trauma, October 1, 2007; 9(4): 283 - 289. [Abstract] [PDF] |
||||
![]() |
B. Ali and A. M. Zafari Narrative Review: Cardiopulmonary Resuscitation and Emergency Cardiovascular Care: Review of the Current Guidelines Ann Intern Med, August 7, 2007; 147(3): 171 - 179. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Fukuda and D. S. Warner Cerebral protection Br. J. Anaesth., July 1, 2007; 99(1): 10 - 17. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Ornato and M. A. Peberdy Measuring Progress in Resuscitation: It's Time for a Better Tool Circulation, December 19, 2006; 114(25): 2754 - 2756. [Full Text] [PDF] |
||||
![]() |
J. A. Cooper, J. D. Cooper, and J. M. Cooper Cardiopulmonary Resuscitation: History, Current Practice, and Future Direction Circulation, December 19, 2006; 114(25): 2839 - 2849. [Full Text] [PDF] |
||||
![]() |
T. D. Rea, M. Helbock, S. Perry, M. Garcia, D. Cloyd, L. Becker, and M. Eisenberg Increasing Use of Cardiopulmonary Resuscitation During Out-of-Hospital Ventricular Fibrillation Arrest: Survival Implications of Guideline Changes Circulation, December 19, 2006; 114(25): 2760 - 2765. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Losert, F. Sterz, K. Kohler, G. Sodeck, R. Fleischhackl, P. Eisenburger, A. Kliegel, H. Herkner, H. Myklebust, J. Nysaether, et al. Quality of Cardiopulmonary Resuscitation Among Highly Trained Staff in an Emergency Department Setting Arch Intern Med, November 27, 2006; 166(21): 2375 - 2380. [Abstract] [Full Text] [PDF] |
||||
![]() |
R Owen and N Castle EtCO2: the key to effective prehospital ventilation. Emerg. Med. J., July 1, 2006; 23(7): 578 - 579. [Full Text] [PDF] |
||||
![]() |
R. D. White 2005 American Heart Association Guidelines for Cardiopulmonary Resuscitation: Physiologic and Educational Rationale for Changes Mayo Clin. Proc., June 1, 2006; 81(6): 736 - 740. [Full Text] [PDF] |
||||
![]() |
American Heart Association 2005 American Heart Association (AHA) Guidelines for Cardiopulmonary Resuscitation (CPR) and Emergency Cardiovascular Care (ECC) of Pediatric and Neonatal Patients: Pediatric Basic Life Support Pediatrics, May 1, 2006; 117(5): e989 - e1004. [Abstract] [Full Text] [PDF] |
||||
![]() |
American Heart Association 2005 American Heart Association (AHA) Guidelines for Cardiopulmonary Resuscitation (CPR) and Emergency Cardiovascular Care (ECC) of Pediatric and Neonatal Patients: Pediatric Advanced Life Support Pediatrics, May 1, 2006; 117(5): e1005 - e1028. [Full Text] [PDF] |
||||
![]() |
The International Liaison Committee on Resuscitati The International Liaison Committee on Resuscitation (ILCOR) Consensus on Science With Treatment Recommendations for Pediatric and Neonatal Patients: Pediatric Basic and Advanced Life Support Pediatrics, May 1, 2006; 117(5): e955 - e977. [Abstract] [Full Text] [PDF] |
||||
![]() |
Part 3: Overview of CPR Circulation, December 13, 2005; 112(24_suppl): IV-12 - IV-18. [Full Text] [PDF] |
||||
![]() |
Part 4: Adult Basic Life Support Circulation, December 13, 2005; 112(24_suppl): IV-19 - IV-34. [Full Text] [PDF] |
||||
![]() |
Part 11: Pediatric Basic Life Support Circulation, December 13, 2005; 112(24_suppl): IV-156 - IV-166. [Full Text] [PDF] |
||||
![]() |
Part 12: Pediatric Advanced Life Support Circulation, December 13, 2005; 112(24_suppl): IV-167 - IV-187. [Full Text] [PDF] |
||||
![]() |
M. F. Hazinski, V. M. Nadkarni, R. W. Hickey, R. O'Connor, L. B. Becker, and A. Zaritsky Major Changes in the 2005 AHA Guidelines for CPR and ECC: Reaching the Tipping Point for Change Circulation, December 13, 2005; 112(24_suppl): IV-206 - IV-211. [Full Text] [PDF] |
||||
![]() |
K. A. Marill and P. T. Ellinor Case 37-2005 -- A 35-Year-Old Man with Cardiac Arrest while Sleeping N. Engl. J. Med., December 8, 2005; 353(23): 2492 - 2501. [Full Text] [PDF] |
||||
![]() |
Part 2: Adult Basic Life Support Circulation, November 29, 2005; 112(22_suppl): III-5 - III-16. [Full Text] [PDF] |
||||
![]() |
Part 3: Defibrillation Circulation, November 29, 2005; 112(22_suppl): III-17 - III-24. [Full Text] [PDF] |
||||
![]() |
Part 4: Advanced Life Support Circulation, November 29, 2005; 112(22_suppl): III-25 - III-54. [Full Text] [PDF] |
||||
![]() |
Part 6: Pediatric Basic and Advanced Life Support Circulation, November 29, 2005; 112(22_suppl): III-73 - III-90. [Full Text] [PDF] |
||||
![]() |
M. F. Hazinski, J. P. Nolan, L. B. Becker, and P. A. Steen Controversial Topics From the 2005 International Consensus Conference on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations Circulation, November 29, 2005; 112(22_suppl): III-133 - III-136. [Full Text] [PDF] |
||||
![]() |
D. Yannopoulos, V. M. Nadkarni, S. H. McKnite, A. Rao, K. Kruger, A. Metzger, D. G. Benditt, and K. G. Lurie Intrathoracic Pressure Regulator During Continuous-Chest-Compression Advanced Cardiac Resuscitation Improves Vital Organ Perfusion Pressures in a Porcine Model of Cardiac Arrest Circulation, August 9, 2005; 112(6): 803 - 811. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. A. Boddicker, Y. Zhang, M. B. Zimmerman, L. R. Davies, and R. E. Kerber Hypothermia Improves Defibrillation Success and Resuscitation Outcomes From Ventricular Fibrillation Circulation, June 21, 2005; 111(24): 3195 - 3201. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. A. Ewy Cardiocerebral Resuscitation: The New Cardiopulmonary Resuscitation Circulation, April 26, 2005; 111(16): 2134 - 2142. [Full Text] [PDF] |
||||
![]() |
B. S. Abella, N. Sandbo, P. Vassilatos, J. P. Alvarado, N. O'Hearn, H. N. Wigder, P. Hoffman, K. Tynus, T. L. Vanden Hoek, and L. B. Becker Chest Compression Rates During Cardiopulmonary Resuscitation Are Suboptimal: A Prospective Study During In-Hospital Cardiac Arrest Circulation, February 1, 2005; 111(4): 428 - 434. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Wik, J. Kramer-Johansen, H. Myklebust, H. Sorebo, L. Svensson, B. Fellows, and P. A. Steen Quality of Cardiopulmonary Resuscitation During Out-of-Hospital Cardiac Arrest JAMA, January 19, 2005; 293(3): 299 - 304. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. S. Abella, J. P. Alvarado, H. Myklebust, D. P. Edelson, A. Barry, N. O'Hearn, T. L. Vanden Hoek, and L. B. Becker Quality of Cardiopulmonary Resuscitation During In-Hospital Cardiac Arrest JAMA, January 19, 2005; 293(3): 305 - 310. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. B. Sanders and G. A. Ewy Cardiopulmonary Resuscitation in the Real World: When Will the Guidelines Get the Message? JAMA, January 19, 2005; 293(3): 363 - 365. [Full Text] [PDF] |
||||
![]() |
Ventilation During CPR: Too Much of a Good Thing Journal Watch Cardiology, July 16, 2004; 2004(716): 3 - 3. [Full Text] |
||||
![]() |
Ventilation During CPR: Too Much of a Good Thing Journal Watch Emergency Medicine, June 16, 2004; 2004(616): 5 - 5. [Full Text] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2004 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |