Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2004;109:1694-1696
doi: 10.1161/01.CIR.0000126182.49118.52
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stevenson, W. G.
Right arrow Articles by Sweeney, M. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stevenson, W. G.
Right arrow Articles by Sweeney, M. O.
Related Collections
Right arrow Congestive
Right arrow Pacemaker
Right arrowRelated Article

(Circulation. 2004;109:1694-1696.)
© 2004 American Heart Association, Inc.


Focused Perspective

Single Site Left Ventricular Pacing for Cardiac Resynchronization

William G. Stevenson, MD; Michael O. Sweeney, MD

From the Cardiovascular Division, Department of Internal Medicine, Brigham and Women’s Hospital, Boston, Mass.

Correspondence to William G. Stevenson, MD, Cardiovascular Division, Brigham and Women’s Hospital, 75 Francis St, Boston, MA 02115. E-mail wstevenson{at}partners.org


Key Words: Focused Perspectives • pacing • heart failure • ventricles

Chronic, dilated heart failure is often accompanied by delayed ventricular electrical activation manifested as prolonged QRS duration, most commonly in the form of left bundle branch block (LBBB). Exploration of the link between the sequence of cardiac electrical activation and mechanical function is one of the most exciting contemporary areas of research in heart failure, but recognition of the importance of normal ventricular activation patterns for optimal myocardial mechanical performance dates back 75 years. Wiggers1 observed that asynchronous delayed activation of the ventricular musculature induced by electrical stimulation had adverse hemodynamic consequences in mammals, and he proposed that the more muscle activated before excitation of the Purkinje system, the greater the asynchrony and the weaker the resulting contraction. Forty years later, Schlant2 concluded that asynchronous ventricular activation imposed by LBBB was hemodynamically disadvantageous and coined the term "idioventricular kick" to describe the benefit imparted by coordinated activation. Subsequent studies demonstrated that when one segment of the ventricle, such as the septum, contracts earlier than another segment, such as the lateral wall, the second segment stretches, absorbing some of the initial force, and then begins its late contraction, stretching the first segment.3,4 The resulting contraction is mechanically inefficient, with diminished ejection at an increased metabolic cost. Reductions of myocardial blood flow and wall thickness occur in the region of early activation, a remodeling effect that could theoretically contribute to progression of heart failure.5,6

See p 1741

In 1984, de Teresa et al7 demonstrated that changing the sequence of ventricular activation by pacing could improve cardiac function. Pacing from epicardial leads placed on the right atrium and lateral left ventricular (LV) free wall in patients with LBBB after aortic valve replacement, they noted that left ventricular ejection fraction was maximal when septal and free wall contraction were simultaneous and diminished when septal and free wall motion were dyssynchronous. Ten years later, Cazeau and colleagues8 applied the term "cardiac resynchronization" to the favorable modification of cardiac activation sequence by pacing in patients with cardiomyopathy and LBBB.

Early attempts at epicardial LV pacing via the coronary veins using pacing leads designed for the right ventricular (RV) apex or left atrium via the coronary sinus met with difficult lead placement and instability and high pacing thresholds.9 With the development of pacing systems designed for the task, progress has been swift. A meta-analysis of randomized trials of cardiac resynchronization therapy (CRT) using these first generation pacing systems in 1634 patients found that heart failure deaths were reduced by 51% (from 3.5% to 1.7%) and heart failure hospitalizations were reduced by 29%.10 The demonstrated benefit is remarkable in view of the failure of approximately 20% to 30% of patients to respond with symptomatic improvement to CRT and that methods to optimize lead placement and patient selection are still unresolved.11,12

Failure to respond favorably to CRT may simply indicate that mechanical activation is not dyssynchronous despite delayed ventricular activation.13,14 It is likely, however, that inability to select or achieve adequate pacing sites is an important factor. Success of resynchronization is dependent on pacing from a site that changes the sequence of ventricular activation in a manner that translates to an improvement in cardiac performance. Ideally, pacing sites that produce the best hemodynamic effect would be selected. Methods for identifying the best site during implantation are not yet of proven clinical benefit. Pacing from the site that produces the greatest decrease in QRS duration makes intuitive sense, but the correlation between decrease in QRS duration and hemodynamic effect has been poor; hemodynamic improvement can occur without shortening of the QRS duration.15 Acute hemodynamic studies have shown that pacing from the LV free wall is generally superior to pacing from the anterior interventricular vein, near the septum. Furthermore, pacing from anterior LV sites can exacerbate asynchrony and be disadvantageous in some patients.16 Individual responses, however, reveal important exceptions. A few patients have a better acute hemodynamic response to RV rather than LV or biventricular pacing, possibly related to the ability to rapidly activate a portion of the LV during RV apical pacing in these individuals (Angelo Auricchio, MD, Otto-von-Guericke Universitaet, University Hospital, Magdeburg, Germany, unpublished data, 2003).17

Even if optimal LV pacing sites could be identified a priori, access to such sites is potentially constrained by variations in coronary venous anatomy, high pacing thresholds related to epicardial scar, or unacceptable phrenic nerve stimulation. With present systems a suitable pacing site on the LV free wall cannot be achieved in 5% to 10% of patients. Surgical placement of epicardial LV pacing leads or endocardial LV stimulation may be options when the coronary venous approach fails.18

The initial randomized trials of CRT have utilized devices incorporating RV and LV pacing sites, largely because of familiarity with, acceptance of, and demonstrated safety of the RV pacing lead, rather than evidence that RV pacing was required for hemodynamic benefit. An RV pacing site is not required, however, for hemodynamic benefit in many patients. Left ventricular pacing alone has short-term hemodynamic benefits similar or superior to those achieved with biventricular pacing in many patients.3,19–21 Two small studies suggested that benefit of single site LV pacing is persistent at 4 weeks and 6 months.17,22

In this issue of Circulation, Blanc and coworkers23 extend the follow-up observations of single site LV pacing. Functional capacity (6-minute walk and maximal O2 uptake), ventricular size and function, and blood norepinephrine levels before and after 12 months of left univentricular pacing were evaluated in 22 patients with dilated cardiomyopathy, LBBB, and New York Heart Association class III or IV heart failure. The LV lead was placed in a lateral coronary vein when possible and all patients had sinus rhythm to allow atrial synchronous left univentricular pacing with an AV delay initially programmed to 100 ms. Significant improvements in functional capacity, echocardiographic mitral regurgitation, and LV end diastolic diameter were observed with favorable trend toward improvement in LV ejection fraction.

It should be recognized that the design of the study likely selected CRT "responders." Of the initial 43 patients who underwent implantation, 7 died before 1 year and thus could not be evaluated. An additional 13 patients had not yet reached 1 year of follow-up and their data were not reported. There was no control group. These results in the remaining 23 patients are encouraging, however, supporting persistent benefit (at least to 1 year) of left univentricular pacing in some patients who respond to CRT.

How should this information be used? Given individual variations in heart failure etiologies, severity, patterns of delayed ventricular activation, location of regions of scar, and extent of mitral regurgitation, it seems unlikely that one pacing site will "fit all." At present, it is not possible to identify patients who will respond better to LV pacing alone compared with biventricular pacing or neither, and it is not clear how to identify the optimal pacing site. Biventricular pacing systems with separately programmable LV and RV stimulation outputs and timing delay will allow adjustments to be made during follow-up that will facilitate further studies and hopefully clarify some of these issues.24 Other factors will continue to warrant RV lead placement in many patients. Although no LV lead dislodgements were observed in the study by Blanc et al,23 the incidence has been reported at 5% to 10% in larger studies.11,25 Patients with poor LV function are at risk for sudden cardiac death from ventricular arrhythmias. Present implantable defibrillator systems require a RV lead for tachyarrhythmia sensing and high voltage therapies and have a long record of safety and reliability in this regard. Further data defining the safety and reliability of LV leads for tachyarrhythmia sensing and possibly defibrillation26 are essential before RV leads are abandoned in CRT pacing and CRT defibrillation systems.

Better understanding of the link between activation sequence and mechanical function may also have important implications for the large number of patients who receive pacemakers for bradyarrhythmias. QRS duration is prolonged during RV apical pacing. Ventricular desynchronization imposed by RV pacing even when AV synchrony is preserved causes increased left atrial diameters and reduced LV fractional shortening27 and is associated with increased atrial fibrillation, heart failure, and death among patients with normal baseline QRSd.28,29 In a canine model, pacing at the LV septum or apex maintains ventricular pumping function at normal levels despite pacing-induced QRSd prolongation.30 It is likely that systems incorporating an RV lead will continue to predominate. If LV pacing systems can become as reliable as RV pacing systems, the paradigm could shift.


*    Footnotes
 
The opinions expressed in this article are not necessarily those of the editors or of the American Heart Association.


*    References
up arrowTop
*References
 

  1. Wiggers C. The muscular reactions of the mammalian ventricles to artificial surface stimuli. Am J Physiol. 1925; 73: 346–378.[Free Full Text]
  2. Schlant RC. Idioventricular kick. Circulation. 1966; 33 (suppl III): III–209.Abstract.
  3. Kass DA. Ventricular resynchronization: pathophysiology and identification of responders. Rev Cardiovasc Med. 2003; 4 (suppl 2): S3–S13.
  4. Verbeek XA, Vernooy K, Peschar M, et al. Intra-ventricular resynchronization for optimal left ventricular function during pacing in experimental left bundle branch block. J Am Coll Cardiol. 2003; 42: 558–567.[Abstract/Free Full Text]
  5. Prinzen FW, Augustijn CH, Arts T, et al. Redistribution of myocardial fiber strain and blood flow by asynchronous activation. Am J Physiol. 1990; 259: H300–H308.[Medline] [Order article via Infotrieve]
  6. Prinzen FW, Cheriex EC, Delhaas T, et al. Asymmetric thickness of the left ventricular wall resulting from asynchronous electric activation: a study in dogs with ventricular pacing and in patients with left bundle branch block. Am Heart J. 1995; 130: 1045–1053.[CrossRef][Medline] [Order article via Infotrieve]
  7. de Teresa E, Chamorro JL, Pulpon LA. An even more physiologic pacing: changing the sequence of activation. In: Steinbech KGD, Laskovics A, et al, eds. Cardiac Pacing. Proceedings of the VIIth World Symposium on Cardiac Pacing. Darmstadt, Germany: Steinkoopff Verlag; 1984: 95–400.
  8. Cazeau S, Ritter P, Bakdach S, et al. Four chamber pacing in dilated cardiomyopathy. Pacing Clin Electrophysiol. 1994; 17: 1974–1979.[CrossRef][Medline] [Order article via Infotrieve]
  9. Daubert JC, Ritter P, Le Breton H, et al. Permanent left ventricular pacing with transvenous leads inserted into the coronary veins. Pacing Clin Electrophysiol. 1998; 21: 239–245.[CrossRef][Medline] [Order article via Infotrieve]
  10. Bradley DJ, Bradley EA, Baughman KL, et al. Cardiac resynchronization and death from progressive heart failure: a meta-analysis of randomized controlled trials. JAMA. 2003; 289: 730–740.[Abstract/Free Full Text]
  11. Abraham WT, Fisher WG, Smith AL, et al. Cardiac resynchronization in chronic heart failure. N Engl J Med. 2002; 346: 1845–1853.[Abstract/Free Full Text]
  12. Reuter S, Garrigue S, Barold SS, et al. Comparison of characteristics in responders versus nonresponders with biventricular pacing for drug-resistant congestive heart failure. Am J Cardiol. 2002; 89: 346–350.[CrossRef][Medline] [Order article via Infotrieve]
  13. Pitzalis MV, Iacoviello M, Romito R, et al. Cardiac resynchronization therapy tailored by echocardiographic evaluation of ventricular asynchrony. J Am Coll Cardiol. 2002; 40: 1615–1622.[Abstract/Free Full Text]
  14. Kerckhoffs RC, Bovendeerd PH, Kotte JC, et al. Homogeneity of cardiac contraction despite physiological asynchrony of depolarization: a model study. Ann Biomed Eng. 2003; 31: 536–547.[CrossRef][Medline] [Order article via Infotrieve]
  15. Leclercq C, Faris O, Tunin R, et al. Systolic improvement and mechanical resynchronization does not require electrical synchrony in the dilated failing heart with left bundle-branch block. Circulation. 2002; 106: 1760–1763.[Abstract/Free Full Text]
  16. Butter C, Auricchio A, Stellbrink C, et al. Effect of resynchronization therapy stimulation site on the systolic function of heart failure patients. Circulation. 2001; 104: 3026–3029.[Abstract/Free Full Text]
  17. Auricchio A, Stellbrink C, Sack S, et al. Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay. J Am Coll Cardiol. 2002; 39: 2026–2033.[Abstract/Free Full Text]
  18. Garrigue S, Jais P, Espil G, et al. Comparison of chronic biventricular pacing between epicardial and endocardial left ventricular stimulation using Doppler tissue imaging in patients with heart failure. Am J Cardiol. 2001; 88: 858–862.[CrossRef][Medline] [Order article via Infotrieve]
  19. Auricchio A, Stellbrink C, Block M, et al. Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure. The Pacing Therapies for Congestive Heart Failure Study Group. The Guidant Congestive Heart Failure Research Group. Circulation. 1999; 99: 2993–3001.[Abstract/Free Full Text]
  20. Blanc JJ, Etienne Y, Gilard M, et al. Evaluation of different ventricular pacing sites in patients with severe heart failure: results of an acute hemodynamic study. Circulation. 1997; 96: 3273–7327.[Abstract/Free Full Text]
  21. Kass DA, Chen CH, Curry C, et al. Improved left ventricular mechanics from acute VDD pacing in patients with dilated cardiomyopathy and ventricular conduction delay. Circulation. 1999; 99: 1567–1573.[Abstract/Free Full Text]
  22. Touiza A, Etienne Y, Gilard M, et al. Long-term left ventricular pacing: assessment and comparison with biventricular pacing in patients with severe congestive heart failure. J Am Coll Cardiol. 2001; 38: 1966–1970.[Abstract/Free Full Text]
  23. Blanc J-J, Bertault-Valls V, Fatemi M, et al. Midterm benefits of left univentricular pacing in patients with congestive heart failure. Circulation. 2003; 109: 1741–1744.
  24. Sogaard P, Egeblad H, Pedersen AK, et al. Sequential versus simultaneous biventricular resynchronization for severe heart failure: evaluation by tissue Doppler imaging. Circulation. 2002; 106: 2078–2084.[Abstract/Free Full Text]
  25. Young JB, Abraham WT, Smith AL, et al. Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial. JAMA. 2003; 289: 2685–2694.[Abstract/Free Full Text]
  26. Butter C, Meisel E, Engelmann L, et al. Human experience with transvenous biventricular defibrillation using an electrode in a left ventricular vein. Pacing Clin Electrophysiol. 2002; 25: 324–331.[CrossRef][Medline] [Order article via Infotrieve]
  27. Nielsen JC, Kristensen L, Andersen HR, et al. A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome. J Am Coll Cardiol. 2003; 42: 614–623.[Abstract/Free Full Text]
  28. Sweeney MO, Hellkamp AS, Ellenbogen KA, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation. 2003; 107: 2932–2937.[Abstract/Free Full Text]
  29. Wilkoff BL, Cook JR, Epstein AE, et al. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA. 2002; 288: 3115–3123.[Abstract/Free Full Text]
  30. Peschar M, de Swart H, Michels KJ, et al. Left ventricular septal and apex pacing for optimal pump function in canine hearts. J Am Coll Cardiol. 2003; 41: 1218–1226.[Abstract/Free Full Text]

Related Article:

Midterm Benefits of Left Univentricular Pacing in Patients With Congestive Heart Failure
Jean-Jacques Blanc, Valérie Bertault-Valls, Marjaneh Fatemi, Martine Gilard, Pierre-Yves Pennec, and Yves Etienne
Circulation 2004 109: 1741-1744. [Abstract] [Full Text]



This article has been cited by other articles:


Home page
Cardiovasc ResHome page
K. M. Kavanagh, I. Belenkie, and H. J. Duff
Transmural temporospatial left ventricular activation during pacing from different sites: potential implications for optimal pacing
Cardiovasc Res, January 1, 2008; 77(1): 81 - 88.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. M. van Gelder, F. A. Bracke, A. Meijer, and N. H.J. Pijls
The Hemodynamic Effect of Intrinsic Conduction During Left Ventricular Pacing as Compared to Biventricular Pacing
J. Am. Coll. Cardiol., December 20, 2005; 46(12): 2305 - 2310.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stevenson, W. G.
Right arrow Articles by Sweeney, M. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stevenson, W. G.
Right arrow Articles by Sweeney, M. O.
Related Collections
Right arrow Congestive
Right arrow Pacemaker
Right arrowRelated Article