(Circulation. 2003;108:II-191.)
© 2003 American Heart Association, Inc.
Surgery for Congenital Heart Disease |
From the Division of Cardiothoracic Surgery, Columbia University College of Physicians and Surgeons, New York, NY, USA.
Correspondence to Michael Argenziano, MD, 177 Fort Washington Avenue, Milstein Hospital, Room 7435, New York, NY. Phone: (212) 305-5888, Fax: (212) 305-2439, Email: ma66{at}columbia.edu
| Abstract |
|---|
|
|
|---|
Methods and Results Seventeen patients underwent repair of a secundum-type atrial septal defect (n=12) or patent foramen ovale (n=5) by a totally endoscopic approach, utilizing the Da Vinci robotic system. Cardiopulmonary bypass (CPB) was achieved peripherally. Cardioplegia was administered via the distal port of the arterial cannula after endo-balloon inflation. Via three port incisions in the right chest, pericardiotomy, bicaval occlusion, atriotomy, atrial septopexy, and atrial closure were performed by a surgeon seated at a computer console. A fourth 15-mm port was utilized for suction and suture passage by a patient-side assistant. The mean age of the patients was 47 years (range, 22 to 68). Aortic crossclamp time was 32 minutes (median), and CPB time was 122 minutes. In 16 patients, transesophageal echocardiography after 30 days confirmed successful repair. In one patient, a recurrent shunt was identified and repaired on postoperative day 5. Median length of stay (LOS) in the intensive care unit was 20 hours, and median hospital length of stay was 4 days.
Conclusions Robotic technology can be utilized to perform open heart procedures safely and effectively via totally endoscopic approaches. This technique represents an option for patients seeking a reliable ASD repair but wishing to avoid sternotomy or thoracotomy.
Key Words: minimally invasive cardiac surgery robotics ASD repair
| Introduction |
|---|
|
|
|---|
Recently, computerized robotic enhancement has emerged as a potential facilitator of minimally invasive surgical procedures. Initially, this technology was utilized to maximize visualization of intracardiac structures by providing enhanced (including voice-activated) endoscopic camera control.1 In the last few years, robotic surgical systems have permitted the manipulation of surgical instruments through limited thoracic incisions.2 This report describes the next step in this progression: the performance of atrial septal defect repair entirely through thoracoscopic port incisions. Torracca and colleagues3 have recently reported a small series of patients undergoing this operation in Europe. Our series of robotic ASD repairs supplements this experience. The first case of our series was performed in July 2001,4 and represents the first U.S. application of robotic technology for totally endoscopic open heart surgery.
| Methods |
|---|
|
|
|---|
|
Patient Selection
All patients in our series were enrolled in a U.S. Food and Drug Administration (FDA)-sanctioned trial, entitled "Atrial septal defect closure using Intuitive Surgical Inc.s Da Vinci Surgical System" and gave informed consent. This study was approved by the Columbia University Institutional Review Board and received FDA Investigational Device Exemption (IDE # G010156, G010189). Intuitive Surgical, Inc. served as study sponsor for the multicenter IDE trial (G010189). This report comprises our single-institution experience from these two trials, in which a maximum of 25 patients could be enrolled and the primary endpoint was echocardiographic evaluation of residual interatrial shunt after 30 days. Inclusion criteria for the trial included age between 18 and 80 years, and the presence of a secundum type atrial septal defect with Qp:Qs ratio >1.5, or patent foramen ovale with a documented neurologic event. Patients were excluded if they could not tolerate single-lung ventilation or peripheral cardiopulmonary bypass, or otherwise were considered poor candidates for a thoracoscopic approach.
Operative Procedure
After induction of general anesthesia, a left-sided double-lumen endotracheal tube was positioned to allow single-lung ventilation. A transesophageal echocardiography probe and bilateral arterial pressure monitoring lines were inserted to facilitate monitoring of endoaortic balloon positioning later in the procedure. A 15- or 17-Fr. arterial cannula (Medtronic Bio-Medicus, Eden Prairie, MN) was placed percutaneously into the right internal jugular vein and passed into the superior vena cava with echocardiographic guidance. This cannula was heparinized before and after insertion to avoid thrombus formation. The patient was placed in a modified left lateral decubitus position, with the right arm either suspended above the head (n=7) or tucked at the side (n=10) and the pelvis relatively flat to facilitate femoral cannulation. After sterile preparation and draping, the right femoral vessels were accessed through a 2-cm oblique incision along the inguinal crease. After systemic heparinization, the right common femoral artery was cannulated with a 17- or 21-Fr. remote access perfusion cannula with endoaortic balloon (ESTECH, Inc., Danville, CA) (Figure 2). The distal tip of the arterial cannula was passed under echocardiographic guidance into the ascending aorta, approximately 3 cm from the aortic valve. The bypass circuit was completed by inserting a 19- or 21-Fr. venous cannula (Medtronic Bio-Medicus) into the right common femoral vein and passing it into the inferior vena cava, with its tip just inferior to the inferior vena cava-right atrium junction.
|
After establishment of selective left lung ventilation, a port incision was made in the fourth intercostal space, in the midclavicular line, and a 12-mm endoscopic trocar (Ethicon, Inc., Somerville, NJ) was placed into the pleural space. The endoscopic camera was inserted and after pleural adhesions were ruled out, the pleural space was insufflated with carbon dioxide to a maximum pressure of 8 mm Hg. Two additional 8-mm port incisions were made in the third and sixth intercostal spaces, in the anterior axillary line. The Da Vinci Surgical Cart was positioned at the operating table, and the left and right robotic arms inserted into the pleural space. A fourth port incision (15 mm) was made in the fifth intercostal space, in the posterior axillary line, for use as a service entrance.
Next, the operating surgeon moved from the operating table to the surgeons console, and began the intrathoracic portion of the operation by controlling the robotic camera and surgical instrument arms. A pericardiotomy was made using the "long-tip forceps" and "cautery" attachments, and pericardial stay sutures placed, with traction provided by passing the sutures out of the chest through the service port (posteriorly) or by sewing the suture to the inside of the chest wall (anteriorly). Caval snares were placed using the long-tip forceps and passed out of the service entrance port. Cardiopulmonary bypass was initiated, with kinetically assisted bicaval venous drainage, and the patient was cooled to 32 degrees. Atrial stay sutures were placed. The perfusion pressure was reduced, and the endoaortic balloon inflated to a pressure of 250 to 300 mm Hg. Antegrade cold blood cardioplegia (4:1) was administered through the distal cannula port, and a satisfactory cardiac arrest was confirmed.
Using the round-tip scissors attachment, a right atriotomy was created, and the right atrium explored. Cardiotomy suction was provided by a specially modified instrument (the "Flora sucker"), which was passed through the service entrance port by the patient-side surgeon. In each case, anatomic landmarks, including the fossa ovalis, coronary sinus ostium, and eustachian valve, were identified. Whether the pathology involved a large ASD or PFO with or without a septal aneurysm, we closed the entire fossa with a double layer primary suture technique (40 polypropylene or braided polyester). Before tying the atrial septopexy suture, the left atrium was de-aired by inflating the left lung. After the suture was tied, the endoaortic balloon was deflated, and the patient was rewarmed. The atriotomy was closed with two layers of running suture, and the patient was weaned from cardiopulmonary bypass. Integrity of the septal closure was conformed by transesophageal echocardiography, and protamine was administered. After adequate hemostasis was achieved, the robotic arms were removed from the chest, and a small flexible drainage tube placed in the pericardium and one or two conventional chest tubes placed in the right pleural space, all through existing port incisions. The femoral vessels were decannulated, and the percutaneous catheter removed from the internal jugular vein. All incisions are closed in layers with absorbable suture material.
Postoperative Regimen
The patients were transported to the intensive care unit where they remained until extubated. On extubation, patients were transferred to the general postoperative unit. Chest drains were removed when drainage subsided. Anticoagulants were administered only for patients with specific postoperative indications such as atrial fibrillation. On discharge, patients were given an appointment for a clinical visit and a transthoracic echocardiogram approximately 1 month postoperatively. At this visit, patients underwent physical examination, electrocardiography, chest radiography, and transthoracic echocardiography. All data, including adverse events, were collected and recorded prospectively.
| Results |
|---|
|
|
|---|
Operative Results
In the 17 patients undergoing robotic surgery, all operations were completed robotically through four port incisions, with no intraoperative conversions to alternate techniques. All patients underwent primary suture repair of the ASD or PFO, and transesophageal echocardiography postoperatively (including bubble study) confirmed successful closure in all cases. Median cardiopulmonary bypass time was 122 minutes, and median crossclamp time was 32 minutes. In the last five cases of our series, median values for cardiopulmonary bypass and crossclamp times were 99 and 29 minutes, respectively. Postoperatively, all patients were extubated on the night of surgery, and median intensive care unit (ICU) length of stay was 20 hours. One patient remained in the ICU for 3 days for treatment of a postoperative pneumonia that was presumed to be related to aspiration, and recovered without incident. Hospital length of stay ranged from 2.5 days (our first patient) to 10 days (in a 68-year-old patient who developed postoperative atrial fibrillation and required several days to establish effective rate control), with a median value of 4 days. Cosmetic results were excellent in all cases (Figure 3).
|
Complications
There were no deaths in our series. There were no cerebrovascular accidents, myocardial infarctions, wound infections, or reoperations for bleeding. There were two cases of perioperative atrial fibrillation, one case of pneumonia, and one patient with temporary arm discomfort because of intraoperative arm positioning. One case was complicated by a right lower leg compartment syndrome, which required a local fasciotomy and delayed skin closure. In this patient, arterial perfusion and venous return were not impaired, leading to the conclusion that the compartment syndrome resulted from ischemia-reperfusion syndrome. In one case, transthoracic echocardiography on postoperative day 5 revealed a 5-mm recurrent interatrial shunt, in a 58-year-old patient who had had a primary repair of a large secundum ASD. When this was confirmed by transesophageal echocardiography, the patient underwent reoperation via right minithoracotomy. At operation, the primary suture line was found to be intact, but a tear was noted in the septum medial to the repair. This was presumably induced by excessive tension on the septum postoperatively, and may have been prevented by a patch technique. A pericardial patch was used for this second repair, and the patient was discharged 4 days later without incident. Because the robotically placed sutures and the line of closure were intact, it is our conclusion that the failure of this repair was not related to the robotic procedure per se, but rather to the use of a primary suture repair technique. In the other 16 patients in the series, 30-day postoperative echocardiography confirmed successful repair.
| Discussion |
|---|
|
|
|---|
The minimally invasive cardiac surgical movement has more recently been propelled by the introduction of a new category of technologic achievement: the computerized telemicromanipulator. Utilizing this device, also known as the surgical robot, surgeons can manipulate small instruments, which are inserted through small chest incisions, in tight spaces, achieving many of the technical maneuvers previously possible only with traditional open exposure. In 1997, the first intracardiac proceduremitral valve repairswere performed using a prototype of the current Da Vinci system.7,8 These operations were performed through small thoracotomy incisions, since the "micro-wrists" allowed the surgeons to complete complex maneuvers without placing their hands within the chest. In December 2000, Chitwood and associates2 reported the first such mitral valve operation performed in the United States, using an inframammary minithoracotomy.
The next stepa totally endoscopic intracardiac procedurewould wait until 2001, when closed-chest, robotically assisted atrial septal defect repairs would be performed, as described in this report. In addition to the six cases reported by Torracca3 and the 17 cases performed by our group, an additional five procedures have been performed in Frankfurt, Germany (G. Wimmer-Greinecker, personal communication). By utilizing femoral cannulation and port incisions in the right chest, the Da Vinci surgical system is utilized to perform every step of the repair. By avoiding thoracotomy incisions and rib spreading, this procedure results in minimal pain and postoperative recovery time. Because this approach provides a time-tested method for ASD repairsuture closure under direct visionit may represent an alternative for patients desiring a minimally invasive ASD repair but who are ineligible for (or reluctant to consider) catheter-based interventions.
Despite the impressive results in our series, and the potential advantages of this approach with regard to cosmesis and patient acceptance, it is currently unclear whether these benefits can be expected in all patients. For this reason, additional patients are being enrolled in our FDA-sanctioned clinical trial, to determine whether this technology will be of reproducible value in the management of patients with intracardiac disease on a larger scale. In addition, we are prospectively studying the effects of this approach on patient recovery, using well-established quality of life instruments to compare robotic and conventional approaches.
Furthermore, it is clear that the continued evolution of totally endoscopic cardiac surgery depends on the development of new accessory technology, such as retraction systems, perfusion catheters, noninvasive monitoring techniques, and sutureless anastomotic devices, and we are working with several industry partners in this area. Thus, although the surgical robot allows unprecedented closed chest access to the heart, it is only one of several tools that must be used to achieve the technical goals of a particular operation. In this respect, the immediate future of closed chest cardiac surgery depends on the ability of physicians and industry to work together to fill in the many technological gaps that are present in our current armamentarium of minimally invasive tools. With such advances, and continued success from pioneering centers, completely endoscopic cardiac surgeryliterally an inconceivable notion only a few years agomay become a widely available clinical reality in the near future.
| Footnotes |
|---|
| References |
|---|
|
|
|---|
2. Chitwood WR Jr., Nifong LW, Elbeery JE, et al. Robotic mitral valve repair: trapezoidal resection and prosthetic annuloplasty with the Da Vinci surgical system. J Thorac Cardiovasc Surg. 2000; 120: 11711172.
3. Torracca L, Ismeno G, Alfieri O. Totally endoscopic computer-enhanced atrial septal defect closure in six patients. Ann Thor Surg. 2001; 72: 13541357.
4. Argenziano M, Oz MC, DeRose JJ, Ashton RC, et al. "Totally endoscopic atrial septal defect repair utilizing robotic assistance." Heart Surg Forum. 2002; 5: 294297.[Medline] [Order article via Infotrieve]
5. Reichenspurner H, Boehm DH, Gulbins H, et al. Three-dimensional video and robot-assisted port-access mitral valve operation. Ann Thorac Surg. 2000; 69: 11761181.
6. Grossi EA, LaPietra A, Ribakove GH, et al. Minimally invasive versus sternotomy approaches for mitral reconstruction: comparison of intermediate-term results. J Thorac Cardiovasc Surg. 2001; 121: 708713.
7. Carpentier A, Loulmet D, Aupecle B, et al. Computer assisted open heart surgery. First case operated on with success. C R Acad Sci III. 1998; 321: 437442.[Medline] [Order article via Infotrieve]
8. Falk V, Walther T, Autschbach R, et al. Robot-assisted minimally invasive solo mitral valve operation. J Thorac Cardiovasc Surg. 1998; 115: 470471.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2003 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |