(Circulation. 2003;107:1059.)
© 2003 American Heart Association, Inc.
Basic Science Reports |
From the Cleveland Clinic Foundation, Cleveland, Ohio (Y.Z., K.A.M. T.N.M.), and the Heart Institute for Children, Hope Childrens Hospital, Oak Lawn, Ill (S.B.).
Correspondence to Todor N. Mazgalev, PhD, Research Institute FF1-02, The Cleveland Clinic Foundation, 9500 Euclid Ave, Cleveland, OH 44195. E-mail mazgalt{at}ccf.org
| Abstract |
|---|
|
|
|---|
Methods and Results In 12 rabbit AVN preparations, HE alternans were confirmed during a standard A1A2 pacing protocol. During AF, in 9 of the 12 hearts, HE alternans indicated the presence of dual pathways. Successful SP modification guided by the HE alternans eliminated the SP, resulting in a predominantly FP conduction during AF in all hearts. This increased the average His-His interval (204±14 versus 276±51 ms, P<0.001). Morphological studies revealed that SP modification damaged only the posterior extension of the AVN.
Conclusions We have demonstrated for the first time in rabbits that HE alternans permit "visualization" of dual-pathway electrophysiology and confirmed the presence of both FP and SP wavefronts during AF. This novel index has been used in a selective SP ablation that resulted in a significant slowing of the ventricular rate. HE alternans provide a new insight into the mechanisms of AVN conduction and could guide AVN modification for ventricular rate control in AF clinically.
Key Words: fibrillation atrioventricular node His bundle alternans electrophysiology
| Introduction |
|---|
|
|
|---|
Recently, we demonstrated that a novel index, which we called His electrogram (HE) alternans, can be used to determine which wavefront, the SP or the fast pathway (FP), reaches the His bundle.5 The term alternans implies that, depending on the atrial coupling interval, the HE amplitude exhibits 2 characteristic levels, low and high. Specifically, during beats with long coupling intervals (eg, sinus beats), the dominant FP wavefront first reaches the superior domain of the His bundle. The ensuing longitudinal activation of the superior His bundle fibers results in early and high-amplitude superior HEs (SHEs), whereas the transverse propagation into the inferior domain produces a later and lower-amplitude inferior HEs (IHEs). In contrast, during beats with short coupling intervals, the conduction blocks within the FP because of its longer effective refractory period (ERP). Now the dominant SP first reaches the inferior His domain, and the synchronized longitudinal activation of inferior fibers produces high-amplitude IHEs, whereas the transverse superior His bundle activation results in later and lower-amplitude SHEs. This phenomenon can be applied, by monitoring the His bundle electrogram alternans, to determine which wavefront is responsible for the propagation of the individual beats during generation of the standard AVN conduction curve.5
We hypothesized that this novel index could be applied during AF as well. Accordingly, in the present study, we used HE alternans for monitoring AVN conduction during AF and attempted to answer the following questions: (1) Are dual pathways involved during AF? (2) Is it possible to selectively modify the SP conduction by using the HE alternans as a guide? (3) How does such modification affect ventricular rate during AF?
| Methods |
|---|
|
|
|---|
|
Electrical Stimulation and Recordings
Bipolar leads (0.2 mm spacing) were custom-made from 125-µm AgAgCl Teflon-isolated wire and used to record atrial electrograms at the crista terminalis and interatrial septum, as well as for atrial pacing. Roving bipolar electrodes were used to record SHEs and IHEs as reported previously.5 All electrodes were positioned with micromanipulators (WPI, M330). An 8-channel, programmable stimulator (AMPI, Master-8) was used for pacing. The recorded signals were amplified and filtered at 50 to 3000 Hz (Axon Instruments, CyberAmp 380), saved on tape (Vetter Digital, 4000A), and later digitized by AxoScope (Axon Instruments) at 200 µs per sample per channel.
Pacing Protocol and Definition of Electrophysiological Terms
All preparations were first paced at a basic cycle length (A1A1 interval) of 300 ms, and a standard AVN conduction curve was generated by interposing a premature A2 stimulus after every 20th basic beat A1. The prematurity coupling interval A1A2 was progressively shortened in 5-ms steps until the occurrence of AVN block. The resultant atrial-His conduction times A2H2 were plotted versus A1A2 prematurities. The AVN ERP was defined in a standard way.6
Random, high-rate, atrial pacing was then used to simulate AF.7 Coupling intervals in the range of 75 to 125 ms were generated by custom-written software. During AF, 2000 His-His (H-H) intervals were measured to determine the shortest, longest, and average values.
Low- and high-amplitude HEs were defined as 2 distinct signal levels recorded from the inferior and superior domains of the His bundle during different prematurities.5 Thus, the IHE was low during FP conduction at coupling intervals typically >170 ms. In contrast, the IHE was high during SP conduction at coupling intervals <170 ms. Because HE alternans were present in both the SHE and IHE recordings in a complimentary (opposite) manner, for simplicity of presentation, only IHE traces are illustrated in some figures.
The above observations were made in controls and repeated after SP modification.
SP Modification
To facilitate the precise location of the putative SP, we used miniature (<2-mm2) thermoelectric probes to cool the tissue in the inferior AVN approaches up to 15°C.5,8 The local block produced was fully reversible. Usually, clear modification effects were noted at the midpoint of the base of the triangle of Koch. The position was considered appropriate when the cooling resulted in a longer AVN ERP, no changes in the conduction time of the basic beats, and elimination of high IHEs during short coupling intervals or AF.
After determination of the best ablation position by cooling, a surgical cut was made (see Figure 6). Successful permanent block of the SP conduction was achieved in all 12 preparations. This was confirmed by repeating the protocol with generation of conduction curves and HE recordings during AF.
Morphological Examination
The AV conduction system was studied by serial sectioning perpendicular to the endocardial surface and oriented parallel to the AV conduction axis. As described previously,9 sections were cut at 7-µm steps, and every 10th section was retained. Alternate sections were stained by hematoxylin-eosin and Weigertvan Gieson stains. In this manner, it was possible to examine all major components of the conduction system, including the inferior approaches, the AVN, the superior approaches, and the penetrating bundle of His.
Statistical Analysis
All data are expressed as mean±SD where appropriate. Comparisons before and after SP modification were performed by paired Students t test. A value of P<0.05 was required for statistical significance.
| Results |
|---|
|
|
|---|
|
Figure 2 shows another preparation, in which HE alternans were present while the conduction curve was being generated (Figure 2, left), confirming that both pathways were intact. However, during AF (Figure 2, right), only pairs of high IHEs and low SHEs were seen, indicating that only the SP conduction was present. This pattern was seen during AF in 3 hearts. There was no difference in average HH interval during AF in these 3 hearts compared with the other 9 hearts with mixed FP and SP conduction (204±14 versus 202±14 ms, P>0.05). However, as seen in Figures 1 and 2, the transition from FP to SP occurred at longer A1A2 in these 3 hearts (197±11 versus 161±18 ms, P<0.05). This might explain why there was a predominant SP in these 3 hearts during AF.
|
No preparation revealed solely FP conduction during AF (ie, only low IHEs).
Use of Localized Cooling to Guide the SP Modification
When the probe was properly placed, a graded elimination of SP conduction was achieved by progressive cooling. Figure 3 illustrates the observations in 1 heart during AF. Note that in controls at 36°C (A), the SP conduction was present in 60% of the beats (high IHEs). Cooling to 28°C (B) eliminated most of the high IHEs, so that 85% of all beats were conducted via the FP (low IHEs, *). At 20°C, the SP was completely blocked and the conduction used the FP exclusively (C). This progressive cooling was also associated with a graded slowing of heart rate (note that the total number of beats was reduced from 30 to 27 to 23 for the same time interval in Figure 3).
|
After exploration with the cooling probe, a surgical cut was placed to produce permanent SP modification, as shown below.
Effects of Permanent SP Modification on AVN Conduction Curve and HE Alternans
Figure 4 shows 1 example of the effect of permanent SP modification on AVN conduction curve (C) and HE alternans (A and B). In control, the IHE (A) indicated that the transition between the FP and SP conduction occurred at A1A2=210 ms, the longest prematurity at which low IHE (*) was recorded. The conduction curve (solid symbols), however, did not exhibit discontinuity at this prematurity. The SP conduction, as evident by the high IHE, was present at all shorter prematurities until the AVN ERP was reached at A1A2=95 ms.
|
A surgical cut, placed similarly to that illustrated in Figure 6, resulted in truncation of the left portion of the conduction curve caused by AVN block at premature A1A2=185 ms (Figure 4C, open symbols). The SP modification did not affect the AVN conduction time during long prematurities (Figure 4C, overlapping open and solid symbols).
The presence of only FP after the modification was confirmed by the only low IHE (Figure 4B), in contrast to the HE alternans observed before modification (Figure 4A). Note also that after the modification, the ERP of the FP shortened: the last low IHE was at A1A2=190 ms (B, *), versus A1A2=210 ms in control (A, *). (It should be noted, however, that the precise ERP of the FP before the ablation remains uncertain, because the FP wavefront might have been either blocked or just sufficiently delayed and replaced by the SP.)
The summarized data from all 12 hearts showed that SP modification guided by the HE alternans did not affect the basic AVN conduction time (68±7 ms in control versus 66±7 ms after modification, P>0.05) but significantly prolonged AVN ERP (from SP-determined ERP of 99±9 ms in control to FP-determined ERP of 147±21 ms after modification, P<0.001). Also, the ERP of the FP, determined by the IHE as illustrated in Figure 4 (*), was consistently shorter after the modification (147±21 versus 171±23 ms, P<0.001).
HE AlternansGuided SP Modification During AF
The effects of permanent SP modification resembled those observed with extreme cooling (Figure 3). Figure 5A (left) is from 1 of 9 hearts in which both wavefronts were participating in AVN conduction during AF in control. Note the presence of high and low (*) IHEs. After SP modification, only low IHEs were seen (A, right, *), indicating that only the FP was operative.
|
Figure 5B illustrates 1 of 3 hearts in which only SP conduction was operative during AF before modification. This is evident by the presence of only high IHEs (B, left). However, after SP modification, only low IHEs appeared (B, right, *). This confirmed that the FP was dormant in control but became dominant once the SP was blocked.
The modification procedure not only blocked SP conduction but also slowed the ventricular rate. The Table summarizes the shortest, the average, and the longest H-H intervals and the percentage of low- and high-amplitude IHEs in all 12 preparations before and after the SP modification. The SP modification consistently prolonged all listed H-H intervals (P<0.01).
|
The SP modification completely eliminated the HE alternans during the generation of the AVN conduction curve in all hearts (Figure 4). However, as seen in the Table, occasional high IHEs were still occurring during AF even after the SP modification. Such an aberration was found in 6 of the studied hearts but was responsible for only 1.0±1.5% of the conducted beats.
Morphological Basis of Slow-Pathway Modification
Serial sections revealed that the cuts, which successfully blocked SP, inflicted damage within the inferior approaches (posterior extension) of the AVN. However, the major part of the AVN remained intact (Figure 6). This indicates that the inferior approaches are a major structure in which the formation of the SP wavefront takes place.
| Discussion |
|---|
|
|
|---|
Dual-Pathway Conduction During AF
Dual-pathway electrophysiology was initially adopted to explain the AVN reentrant tachycardia (AVNRT). A model in which an FP wavefront originates in the superior AVN approaches and a SP wavefront originates in the inferior approaches has been generally accepted.10,11 This model has led to a successful clinical application of curative ablation of AVNRT.12,13 However, its applicability to the AVN conduction during AF remained putative.14
It has been suggested that ablation of the SP or partial damage of the compact AVN might be the mechanism that explains the benefits of the treatment for ventricular rate control.3 This was indirectly supported by several clinical studies14,15 in patients with proven dual-pathway electrophysiology and AVNRT in which fast ventricular rate could be slowed after ablation.
However, in the absence of AVNRT, the dual-pathway conduction can be deduced only by a jump (>50 ms) in the AVN conduction curve for a small shortening of prematurity A1A2 (<10 ms).16 This criterion is clearly not applicable for patients with chronic AF, in whom a standard electrophysiological study cannot be completed.4 Thus, whether dual pathways or only the SP was involved in AVN conduction during AF has never been clarified.
HE Alternans: A Novel Index of Dual-Pathway Electrophysiology During AF
In a previous study,5 we demonstrated that the FP and the SP reach the bundle of His differently, producing characteristic HE alternans. Specifically, at long coupling intervals the FP reaches the superior domain of the His bundle first, resulting in a high SHE and a correspondingly low IHE. The roles become reversed at short coupling intervals (Figures 1, 2, and 5). By monitoring HE alternans, one can easily determine which wavefront reaches the bundle of His in a particular beat.
We have now applied the HE alternans to monitor, in effect to "visualize," the AVN conduction on a beat-by-beat basis during AF (Figures 1 to 3 and 5). The data have demonstrated that both FP and SP are involved in AVN conduction during AF in most cases. In fact, up to 39±30% of the conducted beats during AF were with the FP signature (Table), producing a low IHE (Figure 1). In only 3 of the 12 cases did we see near-exclusive SP conduction during AF with high IHE (Figure 2). However, even in these 3 hearts, after SP modification, the dormant FP was revealed (Figure 5B).
HE AlternansGuided Modification of AVN Inferior Approaches
Modification of the inferior AVN approaches was done by placement of surgical cuts close to but away from the compact AVN (Figure 6). This modification prolonged AVN ERP without affecting the basic conduction time, as previously reported.6 However, in cases with smooth conduction curves, it is difficult to determine whether SP was only partially damaged or totally blocked.
This uncertainty was resolved by the observation of the HE alternans. We noticed that in some cases, an initial prolongation of the AVN ERP after the first surgical cut could coexist with the presence of high IHE at the shortest A1A2 prematurities. This indicated that the SP was still not blocked. A subsequent more distal cut was needed to fully eliminate the HE alternans and establish an even longer ERP (determined now by the FP). In this regard, HE alternans were always a more sensitive criterion for SP modification compared with only monitoring the AVN ERP.
This study clearly demonstrated that SP modification resulted in a predominantly FP conduction during AF, evidenced by the observation of low IHE in the vast majority of the conducted beats (Figure 5). The average ventricular rate was significantly slowed after SP modification (Table). In addition, the shortest H-H intervals (thought to represent the functional refractory period of the AVN during AF17) were significantly prolonged. The excellent correlation observed between the selective modification of the AVN input and the change in the HE alternans (Figures 3 through 5) validates the latter as a reliable index of dual-pathway electrophysiology during AF.
Substrate of SP and a Functional Model of Dual-Pathway Electrophysiology During AF
The morphological evidence indicates that SP modification inflicted damage within the inferior approaches to the AVN. However, the major part of the AVN remained intact (Figure 6). These results are consistent anatomically with the concept of an SP using the atrionodal input via the posterior nodal extensions.6,10,11,18
Our findings could be explained by use of the following functional model. Figure 7A illustrates the beats with FP conduction during AF in an intact preparation. The FP wavefront activates the transitional cell region and reaches the superior domain of the His bundle, producing a high-SHE/low-IHE pair (see Figure 1). At that time, the SP, being formed in the inferior approaches, still traverses the posterior nodal extensions and the AVN itself.
|
Figure 7B illustrates the beats with SP conduction during AF in an intact preparation. In this case, the FP conduction is blocked, presumably within the "bottleneck" formed at the connection with the superior domain of the His bundle. It is therefore possible now for the SP to propagate all the way to the inferior domain of the His bundle, resulting in a high IHE.
According to this model, an FP pattern of HE in a given beat (ie, a low IHE) indicates that the fast wavefront was ahead of the slow wavefront for this beat (as in Figure 7A). Similarly, an SP pattern (ie, a high IHE) would indicate that the FP was blocked (as in Figure 7B).
Figure 7C illustrates the conduction during AF after SP ablation. Successful modification would shift the conduction pattern to the FP, resulting in a substantial reduction of the number of propagated impulses. In addition, for the majority of the conducted beats, only low IHEs would be recorded (Table; 99±1.5% of the beats).
Figure 7D explains why high IHEs could be seen sporadically during AF even after the SP modification (Table; 1±1.5% of the beats). In such cases, a block in the FP and subsequent penetration of the AVN by intermediate wavefronts10 would produce a conduction pattern similar to the one illustrated in Figure 7B.
Our model supports the concept that the SP and the FP are not isolated cable-like structures. Not only does the morphological evidence argue against the presence of cable channels,11,19 but the functional electrophysiological observations also support the hypothesis that the atrionodal approaches are highly inhomogeneous conduction media.20 Although they may support 2, 3, or more functional wavefronts,10,21 especially during AF, no discrete boundaries between them have been delineated.10 The observations from the present study support similar conclusions. Thus, the removal of the SP produced a functional change in the remaining FP (Figure 4), an observation also made in patients22,23 and attributed to an electrotonic inhibition exerted by the SP. Furthermore, if the SP were an isolated cable, then any cut across the inferior approaches would eliminate its conduction. Instead, an "ideal" ablation placement was required, and even then, some high IHEs (ie, SP beats) were still present during AF.
Implications of the Reported Findings and Study Limitations
This study demonstrates that HE alternans are a useful novel tool to monitor dual-pathway electrophysiology on a beat-by-beat basis and can be used to guide AVN modification during AF.
This conclusion is based on the evidence obtained from rabbit hearts. However, HE alternans have also been demonstrated in vivo in dogs.24 Moreover, we have noticed HE changes resembling alternans in published clinical traces,25 although systematic clinical reports are not available and further evidence is needed to establish the presence and functional importance of HE alternans in humans.
Received September 30, 2002; revision received November 7, 2002; accepted November 8, 2002.
| References |
|---|
|
|
|---|
2. Williamson BD, Man KC, Daoud E, et al. Radiofrequency catheter modification of atrioventricular conduction to control the ventricular rate during atrial fibrillation. N Engl J Med. 1994; 331: 910917.
3. Feld GK, Fleck RP, Fujimura O, et al. Control of rapid ventricular response by radiofrequency catheter modification of the atrioventricular node in patients with medically refractory atrial fibrillation. Circulation. 1994; 90: 22992307.
4. Rokas S, Gaitanidou S, Chatzidou S, et al. Atrioventricular node modification in patients with chronic atrial fibrillation: role of morphology of RR interval variation. Circulation. 2001; 103: 29422948.
5. Zhang Y, Bharati S, Mowrey KA, et al. His electrogram alternans reveal dual-wavefront inputs into and longitudinal dissociation within the bundle of His. Circulation. 2001; 104: 832838.
6. Khalife K, Billette J, Medkour D, et al. Role of the compact node and its posterior extension in normal atrioventricular nodal conduction, refractory, and dual pathway properties. J Cardiovasc Electrophysiol. 1999; 10: 14391451.[Medline] [Order article via Infotrieve]
7. Garrigue S, Tchou PJ, Mazgalev TN. Role of the differential bombardment of atrial inputs to the atrioventricular node as a factor influencing ventricular rate during high atrial rate. Cardiovasc Res. 1999; 44: 344355.
8. Garrigue S, Mowrey KA, Fahy G, et al. Atrioventricular nodal conduction during atrial fibrillation: role of atrial input modification. Circulation. 1999; 99: 23232333.
9. Lev M, Bharati S. Lesions of the conduction system and their functional significance. In: Sommers SC, ed. Pathology Annual. New York, NY: Appleton-Century Crofts; 1974: 157208.
10. Wu J, Wu J, Olgin J, et al. Mechanisms underlying the reentrant circuit of atrioventricular nodal reentrant tachycardia in isolated canine atrioventricular nodal preparation using optical mapping. Circ Res. 2001; 88: 11891195.
11. Mazgalev TN, Ho SY, Anderson RH. Anatomic-electrophysiological correlations concerning the pathways for atrioventricular conduction. Circulation. 2001; 103: 26602667.
12. Haissaguerre M, Gaita F, Fischer B, et al. Elimination of atrioventricular nodal reentrant tachycardia using discrete slow potentials to guide application of radiofrequency energy. Circulation. 1992; 85: 21622175.
13. Jackman WM, Beckman KJ, McClelland JH, et al. Treatment of supraventricular tachycardia due to atrioventricular nodal reentry by radiofrequency catheter ablation of slow-pathway conduction. N Engl J Med. 1992; 327: 313318.[Abstract]
14. Kreiner G, Heinz G, Siostrzonek P, et al. Effect of slow pathway ablation on ventricular rate during atrial fibrillation: dependence on electrophysiological properties of the fast pathway. Circulation. 1996; 93: 277283.
15. Blanck Z, Dhala AA, Sra J, et al. Characterization of atrioventricular nodal behavior and ventricular response during atrial fibrillation before and after a selective slow-pathway ablation. Circulation. 1995; 91: 10861094.
16. Markowitz SM, Stein KM, Mittal S, et al. Dual atrionodal physiology in the human heart. In: Mazgalev TN, Tchou PJ, eds. Atrial-AV Nodal Electrophysiology: A View From the Millennium. Armonk, NY: Futura; 2000: 353370.
17. Billette J, Nadeau RA, Roberge F. Relation between the minimum R-R interval during atrial fibrillation and the functional refractory period of the A-V junction. Cardiovasc Res. 1974; 8: 347351.[Medline] [Order article via Infotrieve]
18. Inoue S, Becker AE. Posterior extensions of the human compact atrioventricular node: a neglected anatomic feature of potential clinical significance. Circulation. 1998; 97: 188193.
19. Anderson RH, Ho SY. Anatomic criteria for identifying the components of the axis responsible for atrioventricular conduction. J Cardiovasc Electrophysiol. 2001; 12: 12651268.[CrossRef][Medline] [Order article via Infotrieve]
20. Hocini M, Loh P, Ho SY, et al. Anisotropic conduction in the triangle of Koch of mammalian hearts: electrophysiologic and anatomic correlations. J Am Coll Cardiol. 1998; 31: 629636.
21. Hirao K, Scherlag BJ, Poty H, et al. Electrophysiology of the atrio-AV nodal inputs and exits in the normal dog heart: radiofrequency ablation using an epicardial approach. J Cardiovasc Electrophysiol. 1997; 8: 904915.[Medline] [Order article via Infotrieve]
22. Geller JC, Biblo LA, Carlson MD. New evidence that AV node slow pathway conduction directly influences fast pathway function. J Cardiovasc Electrophysiol. 1998; 9: 10261035.[Medline] [Order article via Infotrieve]
23. Geller JC, Goette A, Reek S, et al. Changes in AV node conduction curves following slow pathway modification. Pacing Clin Electrophysiol. 2000; 23: 16511660.[CrossRef][Medline] [Order article via Infotrieve]
24. Zhang Y, Zhuang S, Mowrey K, et al. In vivo demonstration of His electrogram alternans in dogs. Europace. 2002; 3 (suppl A): A119.Abstract.
25. Maury P, Raczka F, Piot C, et al. QRS and cycle length alternans during paroxysmal supraventricular tachycardia: what is the mechanism? J Cardiovasc Electrophysiol. 2002; 13: 9293.[CrossRef][Medline] [Order article via Infotrieve]