Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2003;107:e38
doi: 10.1161/01.CIR.0000053953.41656.9A
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Avolio, A.
Right arrow Articles by Josephson, M. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Avolio, A.
Right arrow Articles by Josephson, M. E.
Related Collections
Right arrow Electrocardiology
Right arrow Other diagnostic testing
Right arrow Autonomic, reflex, and neurohumoral control of circulation

(Circulation. 2003;107:e38.)
© 2003 American Heart Association, Inc.


Correspondence

Effects of Ventricular Premature Stimulus Coupling Interval on Blood Pressure and Heart Rate Turbulence

Alberto Avolio, PhD

Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia

Michael O’Rourke, MD

St Vincent’s Clinic, Darlinghurst, Sydney, Australia

To the Editor:

The recent article by Watanabe et al1 addresses the important issue of heart rate turbulence (HRT) as a potential noninvasive index for mortality after myocardial infarction. In attempts to investigate underlying mechanisms, the study contains a potentially serious flaw that should be considered by others who might wish to pursue the subject. The authors investigated effects of baroreceptors on HRT by use of measurements of arterial pressure by intravascular catheters. They do no describe the site of measurement, but if it is a peripheral location (eg, radial or brachial artery), the large change in heart rate (40 to 150 beat/min) used in the study can produce substantial errors in using the peripheral pulse as a surrogate of central (carotid or aortic) pulse. Wilkinson et al2 have shown that such a change in heart rate can increase the amplification of the arterial pulse almost 2-fold, such that at higher heart rate, peripheral systolic pressure is grossly exaggerated. This is important in baroreflex assessment, because baroreceptors respond to central and not peripheral systolic pressure.3 With maneuvers such as those applied by Watanabe et al,1 it is desirable that some correction be made4 so that the baroreflex mechanisms of heart rate change associated with a premature ventricular contraction can be elucidated with precision.

References

1. Watanabe MA, Marine JE, Sheldon R, et al. Effects of ventricular premature stimulus coupling interval on blood pressure and heart rate turbulence. Circulation. 2002; 106: 325–330.[Abstract/Free Full Text]

2. Wilkinson IB, Mohammad NH, Tyrell S, et al. Heart rate dependency of pulse pressure amplification and arterial stiffness. Am J Hypertens. 2002; 15: 24–30.[CrossRef][Medline] [Order article via Infotrieve]

3. Avolio A, O’Rourke M. Baroreflex function: improved characterization by use of central vascular parameters compared with peripheral pressure. J Hypertens. 2002; 20: 1067–1070.[CrossRef][Medline] [Order article via Infotrieve]

4. Avolio A, Qasem A, Park YJ. Noninvasive estimation of baroreflex sensitivity using pressure pulse amplification. IEEE Eng Med Biol Magazine. 2001; 20: 53–58.


 

Response

Mari A. Watanabe, MD, PhD

Glasgow Royal Infirmary, Glasgow, UK

Joseph E. Marine, MD

Henry Ford Heart & Vascular Institute, Detroit, Mich

Robert S. Sheldon, MD

Calgary University Health Science Center, Calgary, Canada

Mark E. Josephson, MD

Beth Israel Deaconess Medical Center, Boston, Mass

We appreciate the interest shown by Drs Avolio and O’Rourke in our recent article1 on the relationship between ventricular premature coupling (VPC) interval and heart rate turbulence. They make the important point that pulse pressure measured in the periphery can be much greater than that measured near the heart. We used 5 to 8 Fr arterial sheaths 12 cm long inserted into the femoral artery just below the inguinal ligament. The tip of the sheath would have extended to the common iliac artery in most patients, a fairly central location.

For arguments’ sake, we consider whether our conclusions would have differed had our blood pressure measurements been made from a peripheral location. The amplitude transfer function given in the article by Avolio et al2 indicates that pulse pressure amplification is minimal (1.0) at frequencies lower than 1 Hz (VV interval of 1000 ms), whereas the amplification smoothly increases to 1.4 at 2 Hz (VV interval of 500 ms). In the example we gave in Figure 4, dividing our systolic or pulse pressure values by the amplification factor would have resulted in a steeper slope relating blood pressure value to VPC interval (division of blood pressure at shortest VV interval by 1.4, longest interval by 1), with no change being seen for the relation of blood pressure to compensatory pause interval. For patients with faster baseline heart rate, blood pressure after the compensatory pause would have been affected by a factor close to 1, resulting in a small increase of slope value. Therefore, our published conclusion drawn from the qualitative aspects of behavior such as those seen in Figure 4 would have been unaffected.

Finally, transfer functions relating central to peripheral pressures have not been validated for large beat-to-beat RR interval change like that seen with a VPC. Although transfer functions may be a rigid function determined by the structure of the arterial tree and unaffected by stroke volume, this hypothesis should be validated so that central pressures can be derived with confidence in extreme cases, such as transient arrhythmias. It is not self-evident to us that a transfer function validated at a steady state heart rate of 120 should apply equally to a low-pressure wave produced at a VPC interval of 500 ms (heart rate of 120) in a patient with baseline heart rate of 60.

References

1. Watanabe MA, Marine JE, Sheldon R, et al. Effects of ventricular premature stimulus coupling interval on blood pressure and heart rate turbulence. Circulation. 2002; 106: 325–330.[Abstract/Free Full Text]

2. Avolio A, Qasem A, Park YJ. Noninvasive estimation of baroreflex sensitivity using pressure pulse amplification. IEEE Eng Med Biol. 2001; 20: 53–58.[CrossRef][Medline] [Order article via Infotrieve]





This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Avolio, A.
Right arrow Articles by Josephson, M. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Avolio, A.
Right arrow Articles by Josephson, M. E.
Related Collections
Right arrow Electrocardiology
Right arrow Other diagnostic testing
Right arrow Autonomic, reflex, and neurohumoral control of circulation