Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2003;107:3034-3039
Published online before print June 9, 2003, doi: 10.1161/01.CIR.0000074279.44131.DE
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
107/24/3034    most recent
01.CIR.0000074279.44131.DEv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stoel, M. G.
Right arrow Articles by Visser, C. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stoel, M. G.
Right arrow Articles by Visser, C. A.
Related Collections
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC

(Circulation. 2003;107:3034.)
© 2003 American Heart Association, Inc.


Clinical Investigation and Reports

Frame Count Reserve

Martin G. Stoel, MD; Felix Zijlstra, MD, PhD; Cees A. Visser, MD, PhD

From the Hospital of the Free University, Department of Cardiology, Amsterdam, and University Hospital Groningen (F.Z.), Department of Cardiology, Groningen, the Netherlands.

Correspondence to Martin G. Stoel, MD, Department of Cardiology, Hospital of the Free University, De Boelelaan 1117, 1007 MB Amsterdam, The Netherlands. E-mail mg.stoel{at}vumc.nl


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background— The Doppler wire–derived (relative) coronary flow velocity reserve (CVR) that is used to evaluate functional significance of a coronary stenosis is a method performed only by interventional cardiologists. An angiographic method would be useful in the diagnostic catheterization laboratory. For this purpose, we investigated the relation between TIMI frame count reserve (FCR) and CVR.

Methods and Results— In 38 patients, (relative) FCR of left anterior descending (LAD) and left circumflex coronary artery (LCx) was calculated by using manual, synchronized contrast agent injections and compared with (relative) CVR. In addition, vessel length was measured with an intracoronary guidewire and frame count flow velocity was calculated and compared with average peak velocity. There was a strong correlation between FCR and CVR (r=0.62, P<0.001) and between relative FCR and relative CVR (r=0.84, P<0.001). The LAD was significantly longer than the LCx (mean, 14.3±1.6 cm versus 11.4±1.8 cm, P<0.001), and, therefore, TIMI frame count of LAD was significantly higher than of LCx (mean basal 32.5±15.1 versus 23.6±9.1 and hyperemic 12.1±6.6 versus 8.7±3.2, both P<0.02). However, all flow velocity measurements and estimations of volume flow were not different for LAD compared with LCx. There were also no differences between mean FCR and CVR of LAD or LCx, of both vessels compared with each other and between mean relative FCR and relative CVR.

Conclusion— The (relative) frame count reserve can be used to estimate (relative) coronary flow velocity reserve.


Key Words: coronary disease • blood flow • angiography


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
To assess functional significance of a coronary stenosis, intracoronary Doppler wire–derived coronary flow velocity reserve (CVR) is a well-established method.1 In absence of coronary stenosis, CVR can also be used to evaluate microvascular function.2,3 By comparing CVR of a coronary artery with stenosis to CVR of a normal reference vessel, relative coronary flow velocity reserve (rCVR) is calculated. This corrects for influence of microvascular dysfunction.4,5 CVR >2.0 and rCVR >0.65 are considered appropriate cutoff values to defer angioplasty (percutaneous coronary intervention [PCI]).6,7 Because of the need of an intracoronary Doppler wire and dedicated equipment, only an experienced cardiologist in an interventional catheterization laboratory can perform these measurements. In daily practice, nevertheless, intermediate coronary stenoses of uncertain significance are often encountered during diagnostic angiography. Therefore, an angiographic method to estimate (relative) coronary flow reserve would be very useful.

Some investigators have found good correlation between CVR and (digital subtraction) angiographic estimation of myocardial perfusion,4,8–11 but these 2 methods are essentially different. The TIMI frame count (TFC) is an inverted index of coronary flow velocity that correlates with Doppler wire–derived average peak velocity (APV),12 and it can be used online if angiography is recorded digitally. However, only 1 study investigated the use of TFC as an estimation of coronary flow velocity reserve.13

Although TFC is an index of basal flow velocity, during pharmacologically induced hyperemia, it becomes an index of hyperemic flow velocity. By dividing both counts, an estimate of coronary flow velocity reserve is made. This study was done to compare this (relative) frame count reserve [(r)FCR] with (r)CVR. In addition, with the length of the coronary arteries measured with an intracoronary guidewire,14 frame count velocity (FCV) was calculated and compared with APV determined with the Doppler wire.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Patients
In 38 selected patients referred for diagnostic coronary angiography or PCI for stable angina, FCR and CVR were calculated for both left anterior descending (LAD) and left circumflex coronary artery (LCx). At least 1 of these 2 vessels was normal (visually no stenosis >50%), and all vessels had TIMI 3 flow. In the case of PCI, measurements were repeated thereafter. No patient had left main stenosis >30%, history of obstructive pulmonary disease, or myocardial infarction in the territory of the left coronary artery, and all patients had sinus rhythm. The Medical Ethics Committee of the hospital of the Free University Amsterdam, the Netherlands, approved the protocol. All patients gave written informed consent.

Procedure
One operator (M.S.), using 7F guiding catheters without side holes (Guidant) and ionic contrast agent (Hexabrix, Guerbet), performed all procedures. At the beginning of the procedure, an intravenous bolus of heparin (5000 IU) was given. In all but 1 case of PCI, a stent was implanted; there were no residual stenoses >30%. More than 5 minutes before angiography (Philips Integris 3000, 25 frames/s) and Doppler measurements (Cardiometrics), 0.2 to 0.4 mg intracoronary nitroglycerine was given. Angiography (right anterior oblique with caudal angulation without magnification) was performed by manual injection through the contrast-filled guiding catheter, synchronized to an acoustic heart beat signal. It was performed at least 10 minutes after last balloon inflation and 2 minutes after last contrast injection to prevent reactive hyperemia attributable to ischemia or contrast agent.

Protocol and Calculations
After positioning the Doppler wire in a normal segment of LAD or LCx, as proximal as possible but >2 cm distal to the culprit lesion if present, basal average peak velocity (APV) was recorded together with blood pressure and heart rate. Angiography was performed for basal TFC of both vessels. Hyperemia was induced by adenosine, 140 µg/kg per min intravenous for at least 3 minutes. Hyperemic APV was recorded, and contrast injection for hyperemic TFC was given. The Doppler wire was then repositioned in the ipsilateral vessel with recording of hyperemic APV, after which adenosine was stopped. More than 3 minutes later, basal APV of this vessel was recorded.

CVR was determined by dividing hyperemic by basal APV. With the digitally numbered frames, TFC was calculated as described before.15 FCR was calculated by dividing basal by hyperemic TFC. Relative CVR and rFCR were determined by the ratio of the reserve of LCx and LAD.

The frames between the last QRS complex and the first frame of the TFC were counted. By dividing this number by 25 (frames/s), an estimate was made of the beginning of the contrast injection in relation to the phase of the cardiac cycle.

Length of both coronary arteries was measured by using the Doppler or regular guidewire, as described by Gibson et al.14 The distal end of the guidewire was placed 1 to 3 mm in the distal landmark, marked outside the proximal end of the guiding catheter, then pulled back until 1 to 3 mm was still visible outside the distal end of the guiding catheter and marked again. The measured distance between the 2 marks was used to estimate the length of the coronary artery from the tip of the guiding catheter to the landmark used for the TFC. By multiplying this length by 25/TFC, FCV was calculated.

The diameter of the proximal segment of the coronary artery and the percentage stenosis of the target lesion if present was calculated by quantitative coronary angiography as the mean of 2 orthogonal measurements using the contrast-filled catheter as reference diameter. Coronary volume flow was estimated by the following equation: flow (mL/min)=FCV (cm/s)x60x{pi}x(diameter/2)2.

A coronary vascular resistance index (mm Hg per mL/min) was calculated by dividing mean arterial blood pressure by coronary flow, assuming right atrium pressure was zero.

Statistical Analysis
For statistical analysis, Student’s unpaired t test and linear regression analysis (SPSS 9.0) were used. All continuous variables are expressed as mean±1 SD with their range. P<0.05 was considered statistically significant.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
In 9 patients, both LAD and LCx were normal; in 11 patients, there was visually no significant (<50%) stenosis in LAD and LCx; and in 13 patients, either the proximal LAD (8 patients) or proximal LCx (5 patients) had significant stenosis for which angioplasty was thought appropriate. In 5 patients with intermediate (50% to 70%) lesions, PCI was deferred because of CVR >2.0 and rCVR >0.65. In 2 patients, the study protocol was terminated early, 1 because of advanced atrioventricular block during adenosine infusion and 1 because of damping of the pressure signal of the guiding catheter during hyperemia. Final analysis consisted of 96 flow velocity reserve measurements performed in 38 patients.

Characteristics
Baseline and procedure characteristics are listed in Table 1. In 4 patients, the length of LAD (3 patients) or LCx (3 patients) was not measured, mainly because of severe tortuousities. Most patients used ß-blockers. The LAD was significant longer by a factor of 1.3 compared with the LCx (mean, 14.3±1.6 cm versus 11.4±1.8 cm, P<0.001), whereas there were no differences in diameter of proximal segments (mean 3.2±0.6 mm versus 3.3±0.6 mm) and percentage stenosis of the target lesion. During hyperemia, there was significant decrease in blood pressure (mean 100.7±10.8 to 93.4±10.4 mm Hg, P<0.005) and significant increase in heart rate (mean 67.4±9.0 to 76.3±9.9/min, P<0.005). The mean time interval between last QRS complex and first frame included in the TFC was 370±9 ms. The mean difference between basal and hyperemic injection in relation to the cardiac cycle was 0.07±0.06 seconds.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Baseline and Procedure Characteristics

Measurements
The results of 48 paired (both LAD and LCx) measurements are displayed in Table 2, consisting of 38 patients with repeated protocol after PCI in 10 cases. The values of FCV, volume flow, and resistance index were derived from 44 paired measurements. In 3 vessels, CVR was not measured because the Doppler wire was not repositioned in the nontarget vessel after PCI. TFC of LAD was significantly higher than TFC of LCx (basal 32.5±15.1 versus 23.6±9.1 and hyperemic 12.1±6.6 versus 8.7±3.2, both P<0.02), but there were no significant differences in mean basal and hyperemic flow velocity, flow velocity reserve, volume flow, and resistance index between the vessels. Mean FCR and rFCR did not differ significantly from mean CVR and rCVR.


View this table:
[in this window]
[in a new window]
 
TABLE 2. Procedural Results, Total Measurements

The results of 30 paired (both LAD and LCx) measurements concerning only coronary arteries without visually significant (<50%) stenosis are listed in Table 3, consisting of 20 patients without significant stenosis at baseline and 10 paired measurements after PCI. Again, TFC of LAD was significant higher than TFC of LCx (basal 35.1±17.0 versus 25.1±9.5 and hyperemic 10.3±3.6 versus 8.3±2.7, both P<0.02), without significant differences in mean basal and hyperemic flow velocity, flow velocity reserve, volume flow, and resistance index between the 2 vessels. As in the total group, mean FCR and rFCR did not differ significantly from mean CVR and rCVR.


View this table:
[in this window]
[in a new window]
 
TABLE 3. Procedural Results, No Stenosis >50%

Figure 1 shows the relation between FCR and CVR for all measurements (r=0.62, P<0.001), and Figure 2 shows the relation between rFCR and rCVR (r=0.84, P<0.001). The relation between FCV and APV for basal and hyperemic measurements combined is shown in Figure 3 (r=0.75, P<0.001).



View larger version (18K):
[in this window]
[in a new window]
 
Figure 1. Relation between FCR and CVR, n=96 measurements.



View larger version (17K):
[in this window]
[in a new window]
 
Figure 2. Relation between rFCR and rCVR, n=45 measurements.



View larger version (20K):
[in this window]
[in a new window]
 
Figure 3. Relation between FCV and APV, n=174 measurements.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
In this study, the FCR, an angiographic method using TIMI frame count to estimate coronary blood flow velocity reserve, was compared with Doppler wire–derived CVR. The results demonstrate strong correlation between (r)FCR and (r)CVR. There were no significant differences between mean (r)FCR and mean (r)CVR.

In contrast to normal basal flow velocity, when the coronary artery is usually filled with contrast in >1 complete cycle of the heart (including systole with relative low flow velocity), high coronary flow velocity during hyperemia can cause contrast filling within 1 diastole (with relative high flow velocity). This will result in an augmented FCR compared with CVR in which peak flow velocity is averaged during diastole as well as systole. This can explain the fact that the correlation of FCR and CVR is not so good in the range of high (>3.0) flow velocity reserve compared with low (<3.0) flow velocity reserve, as shown in Figure 1. Low heart rate with relatively more influence from diastole can contribute to this effect, but in this study population, heart rate during hyperemia was higher compared with basal heart rate. In addition, the influence of the moment of contrast injection in relation to the cardiac cycle is more important in case of low TFC (high flow velocity or relative short vessels) compared with high TFC. Because CVR of 2.0 is used as cutoff value, the weaker correlation of values >3.0 has few clinical implications.

The correlation of rFCR and rCVR is stronger also in high values, as is shown in Figure 2, because differences in methods of flow velocity assessment are partially normalized, just like influence of microvascular resistance.

Comparison With Previous Studies
The findings are in accordance with the study by Manginas et al,13 the only other study comparing the TIMI frame count method to CVR. In that study, contrast agent was also injected manually, but adenosine was given by intracoronary injection. However, because of the short half-life time of adenosine, it is difficult to inject the agent consistently in the maximal hyperemic phase. With intravenous adenosine, a steady state of hyperemia can be obtained, making it possible to inject contrast during maximal hyperemia and easier to synchronize injection to the cardiac cycle, resulting in a more accurate hyperemic TFC. As pointed out by Abaci et al,16 the phase of the cardiac cycle in which the contrast agent is injected has important influence on TFC. In the present study, there were only small differences in the timing of contrast injections, beginning at or near the end of the T wave, just before diastole.

The FCR using intracoronary adenosine was measured in a trial evaluating eptifibatide, and it correlated highly with digital subtraction angiographic reserve (r=0.76, P<0.001).17 All TFC (but not the ratios) found in the present European study can only be compared with US studies after being multiplied by a factor of 1.2 to convert to a frame rate of 30 per second. To the best of our knowledge, this is the first study to measure relative FCR and compare it with relative CVR.

Flow Velocity Measurements
A comparison between FCV and APV is complex. With the Doppler wire, peak blood flow velocity is measured locally, averaged during 2 cycles of the heart. It has to be converted to a mean velocity, compensating for lower blood flow velocity near the vessel wall. This can be done by multiplying APV by a factor of 0.518 or by using the velocity integral.19 Because in normal coronary arteries there are no significant differences in proximal and distal flow velocity, additional correction should not be necessary.20 However, segments in which Doppler measurements are performed are not always completely normal because angiography is often not sensitive enough to show diffuse lumen narrowing causing flow velocity acceleration or a positive remodeled vessel segment with possible influence on flow velocity assessment.21 In addition, in stenosed arteries, flow velocity can be higher proximal to the lesion compared with distal because of proximal side branches. This will influence FCV but not distal APV. Finally, length of the coronary artery measured with the guidewire and thus FCV can be underestimated because the wire takes the shortest way along the curves of the vessel. As discussed above, FCV can be overestimated when flow velocity is so high that contrast filling of the coronary artery takes place only in diastole. Figure 3 shows the good correlation between FCV and APV (r=0.75, P<0.001). In this population the ratio of mean APV and FCV was 0.63.

Comparison Between LAD and LCx
Basal and hyperemic TFCs of LAD were significantly higher compared with LCx (basal 32.5±15.1 versus 23.6±9.1 and hyperemic 12.1±6.6 versus 8.7±3.2, both P<0.02). The ratio of TFC of LAD and LCx is 1.4, whereas the ratio of length of both vessels is 1.3. This is less than the factor of 1.7 used to adjust TFC of LAD to derive the corrected TFC because the latter was corrected to mean TFC of both LCx and right coronary artery.15 In the present study, after adjusting TFC to the specific length of the artery, all basal and hyperemic mean blood flow velocity measurements were equal in both vessels. In addition, there were no significant differences in FCR and CVR of LAD compared with LCX. Because the proximal vessel diameter of both vessels was the same, there were also no differences in mean volume flow and resistance index.

Measurements in Nonsignificant Diseased Vessels
Table 3 shows the results of measurements in coronary arteries with visually no stenosis >50%. Mean normal basal FCV of LCA is 12.6±4.5 cm/s and hyperemic 38.0±10.5 cm/s, without differences between LAD and LCx. With this method, estimated volume flow of the LCA is basal 137.5±69.6 and 423.4±198.2 mL/min during hyperemia. However, above-mentioned considerations concerning FCV also apply here. In addition, these results cannot be interpreted as completely normal values because some of these patients had possible microvascular dysfunction (hypertension, dyslipidemia), causing lower hyperemic flow velocity with lower flow velocity reserve. Moreover, in 10 patients, measurements were also performed after PCI. Mean basal FCV after angioplasty was borderline significantly higher compared with the total group (15.8±5.2 versus 12.6±4.5 cm/s, P=0.032), causing a (not significant) lower FCR (2.7±1.1 versus 3.3±1.1). This is in accordance with previous studies in which high basal flow velocity after angioplasty and stenting sometimes persisted for longer than 10 minutes after the procedure because of persistent low microvascular resistance.22,23 Finally, a visual stenosis of <50% can sometimes unexpectedly prove to be functionally significant, and nonsignificant but diffuse epicardial stenosis can cause so much resistance that it impairs flow velocity reserve.

Limitations
All procedures were done by a single operator using manual contrast agent injections. Because timing of injection in relation to the phase of the heart cycle is important,16 it was synchronized to an acoustic heart beat signal. To do this, a basic sense of rhythm is needed. An alternative is the use of an ECG-triggered mechanical injector, but that was not done in this study because diagnostic coronary angiography is usually performed with manual injections. In addition, it has been shown that the impact of the injection rate on the TFC is only minor.24

During adenosine infusion, there was a limited but significant drop in blood pressure with an increase in heart rate, as has been described by others.25 Therefore, hyperemic APV and FCV and thus flow velocity reserve were possibly underestimated.

All measurements were done in LAD and LCx. It is likely but not certain that these results are applicable to the right coronary artery.

The study population consisted of patients who were asymptomatic or had stable angina. Therefore, results may not be applicable to patients with acute coronary syndromes, for example, because flow in normal reference vessels can be impaired.26,27

Conclusion
This study shows that the FCR and rFCR can provide a good estimate of CVR and rCVR. This relative simple, fast, and inexpensive angiographic method can be used during diagnostic catheterization to assess functional significance of a coronary stenosis and, in absence of coronary stenosis, to evaluate microvascular function.

Received January 24, 2003; revision received March 26, 2003; accepted March 31, 2003.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. Kern MJ. Coronary physiology revisited: practical insights from the cardiac catheterization laboratory. Circulation. 2000; 101: 1344–1351.[Abstract/Free Full Text]
  2. L’Abbate A, Sambuceti G, Haunso S, et al. Methods for evaluating coronary microvasculature in humans. Eur Heart J. 1999; 20: 1300–1313.[Free Full Text]
  3. Lim DS, Kim YH, Lee HS, et al. Coronary flow reserve is reflective of myocardial perfusion status in acute anterior myocardial infarction. Catheter Cardiovasc Interv. 2000; 51: 281–286.[CrossRef][Medline] [Order article via Infotrieve]
  4. Baumgart D, Haude M, Goerge G, et al. Improved assessment of coronary stenosis severity using the relative flow velocity reserve. Circulation. 1998; 98: 40–46.[Abstract/Free Full Text]
  5. Kern MJ, Puri S, Bach RG, et al. Abnormal coronary flow velocity reserve after coronary artery stenting in patients: role of relative coronary reserve to assess potential mechanisms. Circulation. 1999; 100: 2491–2498.[Abstract/Free Full Text]
  6. Chamuleau SA, Meuwissen M, Eck-Smit BL, et al. Fractional flow reserve, absolute and relative coronary blood flow velocity reserve in relation to the results of technetium-99 m sestamibi single-photon emission computed tomography in patients with two-vessel coronary artery disease. J Am Coll Cardiol. 2001; 37: 1316–1322.[Abstract/Free Full Text]
  7. Ferrari M, Schnell B, Werner GS, et al. Safety of deferring angioplasty in patients with normal coronary flow velocity reserve. J Am Coll Cardiol. 1999; 33: 82–87.[Abstract/Free Full Text]
  8. Aengevaeren WR, Uijen GJ, van der Werf T. Comparison of coronary flow velocity and regional myocardial perfusion for functional evaluation of coronary artery disease in the setting of angioplasty. Cathet Cardiovasc Diagn. 1998; 45: 16–24.[CrossRef][Medline] [Order article via Infotrieve]
  9. Csizmadia NP, Slump CH, Lubbers AP, et al. Digital densitometric determination of relative coronary flow distributions. Med Biol Eng Comput. 2001; 39: 303–309.[CrossRef][Medline] [Order article via Infotrieve]
  10. Geldof MJ, Schalij MJ, Manger CV, et al. Comparison between regional myocardial perfusion reserve and coronary flow reserve in the canine heart. Eur Heart J. 1995; 16: 1860–1871.[Abstract/Free Full Text]
  11. Serruys PW, Zijlstra F, Laarman GJ, et al. A comparison of two methods to measure coronary flow reserve in the setting of coronary angioplasty: intracoronary blood flow velocity measurements with a Doppler catheter, and digital subtraction cineangiography. Eur Heart J. 1989; 10: 725–736.[Abstract/Free Full Text]
  12. Tanedo JS, Kelly RF, Marquez M, et al. Assessing coronary blood flow dynamics with the TIMI frame count method: comparison with simultaneous intracoronary Doppler and ultrasound. Catheter Cardiovasc Interv. 2001; 53: 459–463.[CrossRef][Medline] [Order article via Infotrieve]
  13. Manginas A, Gatzov P, Chasikidis C, et al. Estimation of coronary flow reserve using the thrombolysis in myocardial infarction (TIMI) frame count method. Am J Cardiol. 1999; 83: 1562–1565.[CrossRef][Medline] [Order article via Infotrieve]
  14. Gibson CM, Dodge JTJ, Goel M, et al. Angioplasty guidewire velocity: a new simple method to calculate absolute coronary blood velocity and flow. Am J Cardiol. 1997; 80: 1536–1539.[CrossRef][Medline] [Order article via Infotrieve]
  15. Gibson CM, Cannon CP, Daley WL, et al. TIMI frame count: a quantitative method of assessing coronary artery flow. Circulation. 1996; 93: 879–888.[Abstract/Free Full Text]
  16. Abaci A, Oguzhan A, Eryol NK, et al. Effect of potential confounding factors on the thrombolysis in myocardial infarction (TIMI) trial frame count and its reproducibility. Circulation. 1999; 100: 2219–2223.[Abstract/Free Full Text]
  17. Gibson CM, Cohen DJ, Cohen EA, et al. Effect of eptifibatide on coronary flow reserve following coronary stent implantation: an ESPRIT substudy. Am J Cardiol. 2001; 87: 1293–1295.[CrossRef][Medline] [Order article via Infotrieve]
  18. Doucette JW, Corl PD, Payne HM, et al. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation. 1992; 85: 1899–1911.[Abstract/Free Full Text]
  19. Labovitz AJ, Anthonis DM, Cravens TL, et al. Validation of volumetric flow measurements by means of a Doppler-tipped coronary angioplasty guide wire. Am Heart J. 1993; 126: 1456–1461.[CrossRef][Medline] [Order article via Infotrieve]
  20. Ofili EO, Kern MJ, St Vrain JA, et al. Differential characterization of blood flow, velocity, and vascular resistance between proximal and distal normal epicardial human coronary arteries: analysis by intracoronary Doppler spectral flow velocity. Am Heart J. 1995; 130: 37–46.[CrossRef][Medline] [Order article via Infotrieve]
  21. Glagov S, Weisenberg E, Zarins CK, et al. Compensatory enlargement of human atherosclerotic coronary arteries. N Engl J Med. 1987; 316: 1371–1375.[Abstract]
  22. van Liebergen RA, Piek JJ, Koch KT, et al. Immediate and long-term effect of balloon angioplasty or stent implantation on the absolute and relative coronary blood flow velocity reserve. Circulation. 1998; 98: 2133–2140.[Abstract/Free Full Text]
  23. Dupouy P, Aptecar E, Pelle G, et al. Early changes in coronary flow physiology after balloon angioplasty or stenting: a 24-hour Doppler flow velocity study. Catheter Cardiovasc Interv. 2002; 57: 191–198.[CrossRef][Medline] [Order article via Infotrieve]
  24. Dodge JTJ, Rizzo M, Nykiel M, et al. Impact of injection rate on the thrombolysis in myocardial infarction (TIMI) trial frame count. Am J Cardiol. 1998; 81: 1268–1270.[CrossRef][Medline] [Order article via Infotrieve]
  25. Jeremias A, Filardo SD, Whitbourn RJ, et al. Effects of intravenous and intracoronary adenosine 5'-triphosphate as compared with adenosine on coronary flow and pressure dynamics. Circulation. 2000; 101: 318–323.[Abstract/Free Full Text]
  26. Gibson CM, Ryan KA, Murphy SA, et al. Impaired coronary blood flow in nonculprit arteries in the setting of acute myocardial infarction: the TIMI Study Group. Thrombolysis in myocardial infarction. J Am Coll Cardiol. 1999; 34: 974–982.[Abstract/Free Full Text]
  27. Gibson CM, Goel M, Murphy SA, et al. Global impairment of coronary blood flow in the setting of acute coronary syndromes (a RESTORE substudy): Randomized Efficacy Study of Tirofiban for Outcomes and Restenosis. Am J Cardiol. 2000; 86: 1375–1377.[CrossRef][Medline] [Order article via Infotrieve]



This article has been cited by other articles:


Home page
Eur Heart JHome page
V. Stangl, V. Witzel, G. Baumann, and K. Stangl
Current diagnostic concepts to detect coronary artery disease in women
Eur. Heart J., March 2, 2008; 29(6): 707 - 717.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
K Vijayalakshmi, V J Whittaker, B Kunadian, J Graham, R A Wright, J A Hall, A Sutton, and M A de Belder
Prospective, randomised, controlled trial to study the effect of intracoronary injection of verapamil and adenosine on coronary blood flow during percutaneous coronary intervention in patients with acute coronary syndromes
Heart, September 1, 2006; 92(9): 1278 - 1284.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. M. Gibson, D. A. Morrow, S. A. Murphy, T. M. Palabrica, L. K. Jennings, P. H. Stone, H. H. Lui, T. Bulle, N. Lakkis, R. Kovach, et al.
A Randomized Trial to Evaluate the Relative Protection Against Post-Percutaneous Coronary Intervention Microvascular Dysfunction, Ischemia, and Inflammation Among Antiplatelet and Antithrombotic Agents: The PROTECT-TIMI-30 Trial
J. Am. Coll. Cardiol., June 20, 2006; 47(12): 2364 - 2373.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. A. Bittl
The Future of an Illusion
J. Am. Coll. Cardiol., June 20, 2006; 47(12): 2380 - 2383.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. K. Chugh, J. Koppel, M. Scott, L. Shewchuk, D. Goodhart, R. Bonan, J.-C. Tardif, S. G. Worthley, C. DiMario, M. J. Curtis, et al.
Coronary flow velocity reserve does not correlate with TIMI frame count in patients undergoing non-emergency percutaneous coronary intervention
J. Am. Coll. Cardiol., August 18, 2004; 44(4): 778 - 782.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
107/24/3034    most recent
01.CIR.0000074279.44131.DEv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stoel, M. G.
Right arrow Articles by Visser, C. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stoel, M. G.
Right arrow Articles by Visser, C. A.
Related Collections
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC